986 resultados para Equip industrial -- Control
Resumo:
Nowadays robots have made their way into real applications that were prohibitive and unthinkable thirty years ago. This is mainly due to the increase in power computations and the evolution in the theoretical field of robotics and control. Even though there is plenty of information in the current literature on this topics, it is not easy to find clear concepts of how to proceed in order to design and implement a controller for a robot. In general, the design of a controller requires of a complete understanding and knowledge of the system to be controlled. Therefore, for advanced control techniques the systems must be first identified. Once again this particular objective is cumbersome and is never straight forward requiring of great expertise and some criteria must be adopted. On the other hand, the particular problem of designing a controller is even more complex when dealing with Parallel Manipulators (PM), since their closed-loop structures give rise to a highly nonlinear system. Under this basis the current work is developed, which intends to resume and gather all the concepts and experiences involve for the control of an Hydraulic Parallel Manipulator. The main objective of this thesis is to provide a guide remarking all the steps involve in the designing of advanced control technique for PMs. The analysis of the PM under study is minced up to the core of the mechanism: the hydraulic actuators. The actuators are modeled and experimental identified. Additionally, some consideration regarding traditional PID controllers are presented and an adaptive controller is finally implemented. From a macro perspective the kinematic and dynamic model of the PM are presented. Based on the model of the system and extending the adaptive controller of the actuator, a control strategy for the PM is developed and its performance is analyzed with simulation.
Resumo:
Este trabajo forma parte del proyecto “Health aware enhanced range wireless power transfer systems”, conocido por el acrónimo de ETHER. Los grupos investigadores que forman parte de ETHER involucran a dos instituciones, Universidad Politécnica de Cataluña (UPC) y Universidad Politécnica de Madrid (UPM). En este caso, el trabajo ha sido llevado a cabo en el marco del Centro de Electrónica Industrial(CEI) de la UPM. Además, este trabajo es el tercero en una sucesión de estudios realizados por el CEI con el objetivo de lograr implementar un sistema de carga inalámbrica en un marcapasos. Los trabajos previos al desarrollado son los realizados por Miguel Gifford y María Gonzalez. Otros trabajos del CEI han servido de guía. El principal objetivo de la aplicación, es evitar las operaciones que se llevan a cabo actualmente para la sustitución de la batería de los marcapasos implantados en pacientes. Este periodo de sustitución es del orden de cuatro años, lo que depende del tipo de marcapasos y las circunstancias en las que se vea envuelto el paciente. Se pretende lograr la carga del dispositivo causando la menor molestia posible al paciente sin afectar a su salud. El sistema de carga inalámrica o WPT1, está basado en inducción magnética resonante, conocida como RIC2. Esta tecnología se fundamenta en el uso de bobinas acopladas como elemento transmisor de energía. A su vez, la impedancia de estas bobinas, es compensada mediante el uso de condensadores, obteniendo circuitos resonantes. Mediante el uso de RIC se logran mejores características técnicas para la transmisión de energía en el rango medio. Esto permite salvar la distancia entre el elemento generador y la batería del marcapasos, incluso ante la existencia de tejido orgánico entre las dos bobinas. Se han considerado dos posibilidades de configuraci´on del sistema. Dos etapas: se dispone de dos bobinas, emisora y receptora. Esta configuración supone trabajar a altas frecuencias para conseguir transferencia de energías efectivas teniendo en cuenta las especificaciones del marcapasos. Tres etapas: se dispone de tres bobinas, emisora, intermedia y receptora. Se mejora el alcance, permitiendo trabajar a menores frecuencias, pero complicando el control y la implementación del sistema. Sin embargo, el foco de los esfuerzos invertidos en este trabajo, es el estudio del sistema de optimización que se introduce en las configuraciones anteriormente descritas. La optimización se centra en conseguir máxima transferencia de potencia, quedando relegado a un segundo plano el rendimiento. Esto se justifica por las características de la aplicación donde la principal limitación es la viabilidad del sistema. Asímismo, la viabilidad viene impuesta por la potencia que consume el marcapasos y la que es capaz de suministrar el sistema. Este sistema de optimización se basa en la regulación en frecuencia y en la adaptación de la impedancia de carga. Este último método es estudiado, y se basa en lograr una impedancia de carga igual al complejo conjugado de la impedancia de salida, logrando máxima transferencia de potencia. El sistema de optimización hace uso de varias estructuras de control de electrónica de potencia. Inversor: Se sitúa en la etapa emisora y permite controlar la frecuencia de trabajo del sistema. Rectificador activo: Se sitúa en la etapa receptora y controla el desfase entre intensidad y tensión. Convertidor CC-CC: Se sitúa en la etapa receptora, tras el rectificador. Controla la amplitud de la tensión.Mediante el uso conjunto del rectificador y el convertidor es posible controlar la impedancia de la carga. Se ha realizado un análisis teórico para determinar el punto de funcionamiento óptimo del sistema, y posteriormente, se han validado estos resultados mediante simulaciones. Se demuestra que la potencia transferida por el sistema WTP se multiplica por cinco respecto de la solución original, es decir, en ausencia del sistema de optimización. Además se logra mayor robustez, ya que el control activo del sistema proporciona mayor adaptabilidad ante condiciones alejadas de las de diseño. El trabajo realizado se ha prolongado durante un periodo de doscientos días efectivos con una dedicación de 360 horas de trabajo. El coste total asignado al desempeño del trabajo es de 16.678,94 euros.
Resumo:
Dentro de las técnicas de control de procesos no lineales, los controladores de estructura variable con modos deslizantes (VSC-SM en sus siglas en inglés) han demostrado ser una solución robusta, por lo cual han sido ampliamente estudiados en las cuatro últimas décadas. Desde los años ochenta se han presentado varios trabajos enfocados a especificar controladores VSC aplicados a sistemas de tiempo discreto (DVSC), siendo uno de los mayores intereses de análisis obtener las mismas prestaciones de robustez e invarianza de los controladores VSC-SM. El objetivo principal del trabajo de Tesis Doctoral consiste en estudiar, analizar y proponer unos esquemas de diseño de controladores DVSC en procesos multivariable tanto lineales como no lineales. De dicho estudio se propone una nueva filosofía de diseño de superficies deslizantes estables donde se han considerado aspectos hasta ahora no estudiados en el uso de DVSC-SM como son las limitaciones físicas de los actuadores y la dinámica deslizante no ideal. Lo más novedoso es 1) la propuesta de una nueva metodología de diseño de superficies deslizantes aplicadas a sistemas MIMO lineales y la extensión del mismo al caso de sistemas multivariables no lineales y 2) la definición de una nueva ley de alcance y de una ley de control robusta aplicada a sistemas MIMO, tanto lineales como no lineales, incluyendo un esquema de reducción de chattering. Finalmente, con el fin de ilustrar la eficiencia de los esquemas presentados, se incluyen ejemplos numéricos relacionados con el tema tratado en cada uno de los capítulos de la memoria. ABSTRACT Over the last four decades, variable structure controllers with sliding mode (VSC-SM) have been extensively studied, demonstrating to be a robust solution among robust nonlinear processes control techniques. Since the late 80s, several research works have been focused on the application of VSC controllers applied to discrete time or sampled data systems, which are known as DVSC-SM, where the most extensive source of analysis has been devoted to the robustness and invariance properties of VSC-SM controllers when applied to discrete systems. The main aim of this doctoral thesis work is to study, analyze and propose a design scheme of DVSC-SM controllers for lineal and nonlinear multivariable discrete time processes. For this purpose, a new design philosophy is proposed, where various design features have been considered that have not been analyzed in DVSC design approaches. Among them, the physical limitations and the nonideal dynamic sliding mode dynamics. The most innovative aspect is the inclusion of a new design methodology applied to lineal sliding surfaces MIMO systems and the extension to nonlinear multivariable systems, in addition to a new robust control law applied to lineal and nonlinear MIMO systems, including a chattering reduction scheme. Finally, to illustrate the efficiency of the proposed schemes, several numerical examples applied to lineal and nonlinear systems are included.
Resumo:
En la última década la potencia instalada de energía solar fotovoltaica ha crecido una media de un 49% anual y se espera que alcance el 16%del consumo energético mundial en el año 2050. La mayor parte de estas instalaciones se corresponden con sistemas conectados a la red eléctrica y un amplio porcentaje de ellas son instalaciones domésticas o en edificios. En el mercado ya existen diferentes arquitecturas para este tipo de instalaciones, entre las que se encuentras los módulos AC. Un módulo AC consiste en un inversor, también conocido como micro-inversor, que se monta en la parte trasera de un panel o módulo fotovoltaico. Esta tecnología ofrece modularidad, redundancia y la extracción de la máxima potencia de cada panel solar de la instalación. Además, la expansión de esta tecnología posibilitará una reducción de costes asociados a las economías de escala y a la posibilidad de que el propio usuario pueda componer su propio sistema. Sin embargo, el micro-inversor debe ser capaz de proporcionar una ganancia de tensión adecuada para conectar el panel solar directamente a la red, mientras mantiene un rendimiento aceptable en un amplio rango de potencias. Asimismo, los estándares de conexión a red deber ser satisfechos y el tamaño y el tiempo de vida del micro-inversor son factores que han de tenerse siempre en cuenta. En esta tesis se propone un micro-inversor derivado de la topología “forward” controlado en el límite entre los modos de conducción continuo y discontinuo (BCM por sus siglas en inglés). El transformador de la topología propuesta mantiene la misma estructura que en el convertidor “forward” clásico y la utilización de interruptores bidireccionales en el secundario permite la conexión directa del inversor a la red. Asimismo el método de control elegido permite obtener factor de potencia cercano a la unidad con una implementación sencilla. En la tesis se presenta el principio de funcionamiento y los principales aspectos del diseño del micro-inversor propuesto. Con la idea de mantener una solución sencilla y de bajo coste, se ha seleccionado un controlador analógico que está originalmente pensado para controlar un corrector del factor de potencia en el mismo modo de conducción que el micro-inversor “forward”. La tesis presenta las principales modificaciones necesarias, con especial atención a la detección del cruce por cero de la corriente (ZCD por sus siglas en inglés) y la compatibilidad del controlador con la inclusión de un algoritmo de búsqueda del punto de máxima potencia (MPPT por sus siglas en inglés). Los resultados experimentales muestran las limitaciones de la implementación elegida e identifican al transformador como el principal contribuyente a las pérdidas del micro-inversor. El principal objetivo de esta tesis es contribuir a la aplicación de técnicas de control y diseño de sistemas multifase en micro-inversores fotovoltaicos. En esta tesis se van a considerar dos configuraciones multifase diferentes aplicadas al micro-inversor “forward” propuesto. La primera consiste en una variación con conexión paralelo-serie que permite la utilización de transformadores con una relación de vueltas baja, y por tanto bien acoplados, para conseguir una ganancia de tensión adecuada con un mejor rendimiento. Esta configuración emplea el mismo control BCM cuando la potencia extraída del panel solar es máxima. Este método de control implica que la frecuencia de conmutación se incrementa considerablemente cuando la potencia decrece, lo que compromete el rendimiento. Por lo tanto y con la intención de mantener unos bueno niveles de rendimiento ponderado, el micro-inversor funciona en modo de conducción discontinuo (DCM, por sus siglas en inglés) cuando la potencia extraía del panel solar es menor que la máxima. La segunda configuración multifase considerada en esta tesis es la aplicación de la técnica de paralelo con entrelazado. Además se han considerado dos técnicas diferentes para decidir el número de fases activas: dependiendo de la potencia continua extraída del panel solar y dependiendo de la potencia instantánea demandada por el micro-inversor. La aplicación de estas técnicas es interesante en los sistemas fotovoltaicos conectados a la red eléctrica por la posibilidad que brindan de obtener un rendimiento prácticamente plano en un amplio rango de potencia. Las configuraciones con entrelazado se controlan en DCM para evitar la necesidad de un control de corriente, lo que es importante cuando el número de fases es alto. Los núcleos adecuados para todas las configuraciones multifase consideradas se seleccionan usando el producto de áreas. Una vez seleccionados los núcleos se ha realizado un diseño detallado de cada uno de los transformadores. Con la información obtenida de los diseños y los resultados de simulación, se puede analizar el impacto que el número de transformadores utilizados tiene en el tamaño y el rendimiento de las distintas configuraciones. Los resultados de este análisis, presentado en esta tesis, se utilizan posteriormente para comparar las distintas configuraciones. Muchas otras topologías se han presentado en la literatura para abordar los diferentes aspectos a considerar en los micro-inversores, que han sido presentados anteriormente. La mayoría de estas topologías utilizan un transformador de alta frecuencia para solventar el salto de tensión y evitar problemas de seguridad y de puesta a tierra. En cualquier caso, es interesante evaluar si topologías sin aislamiento galvánico son aptas para su utilización como micro-inversores. En esta tesis se presenta una revisión de inversores con capacidad de elevar tensión, que se comparan bajo las mismas especificaciones. El objetivo es proporcionar la información necesaria para valorar si estas topologías son aplicables en los módulos AC. Las principales contribuciones de esta tesis son: • La aplicación del control BCM a un convertidor “forward” para obtener un micro-inversor de una etapa sencillo y de bajo coste. • La modificación de dicho micro-inversor con conexión paralelo-series de transformadores que permite reducir la corriente de los semiconductores y una ganancia de tensión adecuada con transformadores altamente acoplados. • La aplicación de técnicas de entrelazado y decisión de apagado de fases en la puesta en paralelo del micro-inversor “forward”. • El análisis y la comparación del efecto en el tamaño y el rendimiento del incremento del número de transformadores en las diferentes configuraciones multifase. • La eliminación de las medidas y los lazos de control de corriente en las topologías multifase con la utilización del modo de conducción discontinuo y un algoritmo MPPT sin necesidad de medida de corriente. • La recopilación y comparación bajo las mismas especificaciones de topologías inversoras con capacidad de elevar tensión, que pueden ser adecuadas para la utilización como micro-inversores. Esta tesis está estructurada en seis capítulos. El capítulo 1 presenta el marco en que se desarrolla la tesis así como el alcance de la misma. En el capítulo 2 se recopilan las topologías existentes de micro-invesores con aislamiento y aquellas sin aislamiento cuya implementación en un módulo AC es factible. Asimismo se presenta la comparación entre estas topologías bajo las mismas especificaciones. El capítulo 3 se centra en el micro-inversor “forward” que se propone originalmente en esta tesis. La aplicación de las técnicas multifase se aborda en los capítulos 4 y 5, en los que se presentan los análisis en función del número de transformadores. El capítulo está orientado a la propuesta paralelo-serie mientras que la configuración con entrelazado se analiza en el capítulo 5. Por último, en el capítulo 6 se presentan las contribuciones de esta tesis y los trabajos futuros. ABSTRACT In the last decade the photovoltaic (PV) installed power increased with an average growth of 49% per year and it is expected to cover the 16% of the global electricity consumption by 2050. Most of the installed PV power corresponds to grid-connected systems, with a significant percentage of residential installations. In these PV systems, the inverter is essential since it is the responsible of transferring into the grid the extracted power from the PV modules. Several architectures have been proposed for grid-connected residential PV systems, including the AC-module technology. An AC-module consists of an inverter, also known as micro-inverter, which is attached to a PV module. The AC-module technology offers modularity, redundancy and individual MPPT of each module. In addition, the expansion of this technology will enable the possibility of economies of scale of mass market and “plug and play” for the user, thus reducing the overall cost of the installation. However, the micro-inverter must be able to provide the required voltage boost to interface a low voltage PV module to the grid while keeping an acceptable efficiency in a wide power range. Furthermore, the quality standards must be satisfied and size and lifetime of the solutions must be always considered. In this thesis a single-stage forward micro-inverter with boundary mode operation is proposed to address the micro-inverter requirements. The transformer in the proposed topology remains as in the classic forward converter and bidirectional switches in the secondary side allows direct connection to the grid. In addition the selected control strategy allows high power factor current with a simple implementation. The operation of the topology is presented and the main design issues are introduced. With the intention to propose a simple and low-cost solution, an analog controller for a PFC operated in boundary mode is utilized. The main necessary modifications are discussed, with the focus on the zero current detection (ZCD) and the compatibility of the controller with a MPPT algorithm. The experimental results show the limitations of the selected analog controller implementation and the transformer is identified as a main losses contributor. The main objective of this thesis is to contribute in the application of control and design multiphase techniques to the PV micro-inverters. Two different multiphase configurations have been applied to the forward micro-inverter proposed in this thesis. The first one consists of a parallel-series connected variation which enables the use of low turns ratio, i.e. well coupled, transformers to achieve a proper voltage boost with an improved performance. This multiphase configuration implements BCM control at maximum load however. With this control method the switching frequency increases significantly for light load operation, thus jeopardizing the efficiency. Therefore, in order to keep acceptable weighted efficiency levels, DCM operation is selected for low power conditions. The second multiphase variation considered in this thesis is the interleaved configuration with two different phase shedding techniques: depending on the DC power extracted from the PV panel, and depending on the demanded instantaneous power. The application of interleaving techniques is interesting in PV grid-connected inverters for the possibility of flat efficiency behavior in a wide power range. The interleaved variations of the proposed forward micro-inverter are operated in DCM to avoid the current loop, which is important when the number of phases is large. The adequate transformer cores for all the multiphase configurations are selected according to the area product parameter and a detailed design of each required transformer is developed. With this information and simulation results, the impact in size and efficiency of the number of transformer used can be assessed. The considered multiphase topologies are compared in this thesis according to the results of the introduced analysis. Several other topological solutions have been proposed to solve the mentioned concerns in AC-module application. The most of these solutions use a high frequency transformer to boost the voltage and avoid grounding and safety issues. However, it is of interest to assess if the non-isolated topologies are suitable for AC-module application. In this thesis a review of transformerless step-up inverters is presented. The compiled topologies are compared using a set benchmark to provide the necessary information to assess whether non-isolated topologies are suitable for AC-module application. The main contributions of this thesis are: • The application of the boundary mode control with constant off-time to a forward converter, to obtain a simple and low-cost single-stage forward micro-inverter. • A modification of the forward micro-inverter with primary-parallel secondary-series connected transformers to reduce the current stress and improve the voltage gain with highly coupled transformers. •The application of the interleaved configuration with different phase shedding strategies to the proposed forward micro-inverter. • An analysis and comparison of the influence in size and efficiency of increasing the number of transformers in the parallel-series and interleaved multiphase configurations. • Elimination of the current loop and current measurements in the multiphase topologies by adopting DCM operation and a current sensorless MPPT. • A compilation and comparison with the same specifications of suitable non-isolated step-up inverters. This thesis is organized in six chapters. In Chapter 1 the background of single-phase PV-connected systems is discussed and the scope of the thesis is defined. Chapter 2 compiles the existing solutions for isolated micro-inverters and transformerless step-up inverters suitable for AC-module application. In addition, the most convenient non-isolated inverters are compared using a defined benchmark. Chapter 3 focuses on the originally proposed single-stage forward micro-inverter. The application of multiphase techniques is addressed in Chapter 4 and Chapter 5, and the impact in different parameters of increasing the number of phases is analyzed. In Chapter 4 an original primary-parallel secondary-series variation of the forward micro-inverter is presented, while Chapter 5 focuses on the application of the interleaved configuration. Finally, Chapter 6 discusses the contributions of the thesis and the future work.
Resumo:
Wireless power transfer (WPT) is an emerging technology with an increasing number of potential applications to transfer power from a transmitter to a mobile receiver over a relatively large air gap. However, its widespread application is hampered due to the relatively low efficiency of current Wireless power transfer (WPT) systems. This study presents a concept to maximize the efficiency as well as to increase the amount of extractable power of a WPT system operating in nonresonant operation. The proposed method is based on actively modifying the equivalent secondary-side load impedance by controlling the phase-shift of the active rectifier and its output voltage level. The presented hardware prototype represents a complete wireless charging system, including a dc-dc converter which is used to charge a battery at the output of the system. Experimental results are shown for the proposed concept in comparison to a conventional synchronous rectification approach. The presented optimization method clearly outperforms state-of-the-art solutions in terms of efficiency and extractable power.
Resumo:
The interest in missions with multiple Unmanned Aerial Vehicles (UAVs) has increased significantly in last years. These missions take advantage of the use of fleets instead of single UAVs to ensure the success, reduce the duration or increase the goals of the mission. In addition, they allow performing tasks that require multiple agents and certain coordination (e.g. surveillance of large areas or transport of heavy loads). Nevertheless, these missions suppose a challenge in terms of control and monitoring. In fact, the workload of the operators rises with the utilization of multiple UAVs and payloads, since they have to analyze more information, make more decisions and generate more commands during the mission. This work addresses the operator workload problem in multi-UAV missions by reducing and selecting the information. Two approaches are considered: a first one that selects the information according to the mission state, and a second one that selects it according to the operator preferences. The result is an interface that is able to control the amount of information and show what is relevant for mission and operator at the time.
Resumo:
We evaluated lignin profiles and pulping performances of 2-year-old transgenic poplar (Populus tremula × Populus alba) lines severely altered in the expression of caffeic acid/5-hydroxyferulic acid O-methyltransferase (COMT) or cinnamyl alcohol dehydrogenase (CAD). Transgenic poplars with CAD or COMT antisense constructs showed growth similar to control trees. CAD down-regulated poplars displayed a red coloration mainly in the outer xylem. A 90% lower COMT activity did not change lignin content but dramatically increased the frequency of guaiacyl units and resistant biphenyl linkages in lignin. This alteration severely lowered the efficiency of kraft pulping. The Klason lignin level of CAD-transformed poplars was slightly lower than that of the control. Whereas CAD down-regulation did not change the frequency of labile ether bonds or guaiacyl units in lignin, it increased the proportion of syringaldehyde and diarylpropane structures and, more importantly with regard to kraft pulping, of free phenolic groups in lignin. In the most depressed line, ASCAD21, a substantially higher content in free phenolic units facilitated lignin solubilization and fragmentation during kraft pulping. These results point the way to genetic modification of lignin structure to improve wood quality for the pulp industry.
Resumo:
O presente trabalho busca analisar os diferentes tratamentos dispensados à marca no âmbito do controle preventivo e no controle repressivo de condutas. A análise da função social das marcas demonstrou que esta é uma propriedade que se realiza na concorrência e pela concorrência. Nesse sentido, não há dúvidas de que está sujeita aos princípios do Direito Concorrencial. Todavia, a maneira como esses princípios balizam a marca no controle de atos de concentração, de um lado, e no controle repressivo de condutas, de outro, difere. No âmbito do controle de atos de concentração, a atuação da autoridade concorrencial é orientada por uma variante do princípio da precaução, o que a autoriza a tomar decisões e impor restrições aos direitos marcários mesmo em um contexto de incerteza. No âmbito do controle repressivo de condutas, todavia, a intervenção do CADE está sujeita aos princípios do Processo Administrativo Sancionador. Neste contexto, as condutas que envolvem o uso de direitos de propriedade intelectual, incluindo as marcas, devem ser analisadas à luz do princípio da estrita legalidade. Um critério jurídico objetivo é necessário para distinguir o lícito do ilícito, sobretudo em um cenário no qual estão em jogo duas políticas públicas distintas: a de proteção à concorrência e a de proteção à direitos de propriedade industrial. Sendo essas duas políticas instrumentais e parciais, voltadas a um fim maior de política econômica, devem harmonizar-se, e não sobrepor-se uma a outra. Ademais, o escopo de atuação da autoridade concorrencial em processos que investiguem o uso abusivo de direitos marcários e atos de concorrência desleal deve ser esclarecido. O direito concorrencial, enquanto ramo autônomo do direito, com princípios e métodos interpretativos próprios, pode analisar institutos e figuras de outros ramos que com ele guardem relação sem ter de ficar adstrito ao posicionamento de outras instâncias.
Resumo:
Este estudo consistiu na investigação sobre a interação dos lubrificantes empregados na usinagem de metais com a matéria orgânica natural (substâncias húmicas), a sua mobilidade no solo, a degradação microbiológica e a remoção dos mesmos do solo. Realizou-se, também, um estudo sobre as mudanças nas características dos fluidos após a sua utilização. Para o processo de degradação das amostras de fluido, submetidos aos efeitos de diferentes fatores ambientais, foram utilizados quatro tratamentos : (i) microrganismos nativos, chamada amostra controle; (ii) amostra controle com matéria orgânica proveniente de turfa; (iii) amostra controle acrescida de microrganismos existentes nos efluentes de máquinas de corte; e (iv) amostra controle com adição de microrganismos de compostagem. Para a pesquisa da degradação sem o efeito dos parâmetros climáticos, foram utilizadas amostras de solo contaminadas mantendo-se em estufa, e a inoculação dos microrganismos em meios de cultura com e sem acréscimo de fonte alternativa de carbono. Como técnicas analíticas, foram utilizadas a CG-DIC e a CG-EM. Essas técnicas são indicadas tanto para estudar a composição dos fluidos quanto dos produtos de degradação microbiológica, tendo sido otimizados métodos analíticos para serem empregados no monitoramento ambiental e de estudos de degradação. As análises por IVTF e por EF também foram empregadas na identificação e quantificação dos fluidos. Observou-se uma considerável interação dos fluidos solúveis com a matéria orgânica do solo, embora tenham se apresentado com alta mobilidade para alguns constituintes, bem como um acelerado processo de degradação durante o uso. De outro modo, os fluidos insolúveis se apresentaram mais imóveis, ficando retidos na matéria orgânica do solo, entretanto, foram mais prontamente degradados no ambiente que os solúveis. A adição de matéria orgânica e de microrganismos de compostagem acelerou o processo de degradação para todos os fluidos de corte investigados.
Resumo:
The increasing economic competition drives the industry to implement tools that improve their processes efficiencies. The process automation is one of these tools, and the Real Time Optimization (RTO) is an automation methodology that considers economic aspects to update the process control in accordance with market prices and disturbances. Basically, RTO uses a steady-state phenomenological model to predict the process behavior, and then, optimizes an economic objective function subject to this model. Although largely implemented in industry, there is not a general agreement about the benefits of implementing RTO due to some limitations discussed in the present work: structural plant/model mismatch, identifiability issues and low frequency of set points update. Some alternative RTO approaches have been proposed in literature to handle the problem of structural plant/model mismatch. However, there is not a sensible comparison evaluating the scope and limitations of these RTO approaches under different aspects. For this reason, the classical two-step method is compared to more recently derivative-based methods (Modifier Adaptation, Integrated System Optimization and Parameter estimation, and Sufficient Conditions of Feasibility and Optimality) using a Monte Carlo methodology. The results of this comparison show that the classical RTO method is consistent, providing a model flexible enough to represent the process topology, a parameter estimation method appropriate to handle measurement noise characteristics and a method to improve the sample information quality. At each iteration, the RTO methodology updates some key parameter of the model, where it is possible to observe identifiability issues caused by lack of measurements and measurement noise, resulting in bad prediction ability. Therefore, four different parameter estimation approaches (Rotational Discrimination, Automatic Selection and Parameter estimation, Reparametrization via Differential Geometry and classical nonlinear Least Square) are evaluated with respect to their prediction accuracy, robustness and speed. The results show that the Rotational Discrimination method is the most suitable to be implemented in a RTO framework, since it requires less a priori information, it is simple to be implemented and avoid the overfitting caused by the Least Square method. The third RTO drawback discussed in the present thesis is the low frequency of set points update, this problem increases the period in which the process operates at suboptimum conditions. An alternative to handle this problem is proposed in this thesis, by integrating the classic RTO and Self-Optimizing control (SOC) using a new Model Predictive Control strategy. The new approach demonstrates that it is possible to reduce the problem of low frequency of set points updates, improving the economic performance. Finally, the practical aspects of the RTO implementation are carried out in an industrial case study, a Vapor Recompression Distillation (VRD) process located in Paulínea refinery from Petrobras. The conclusions of this study suggest that the model parameters are successfully estimated by the Rotational Discrimination method; the RTO is able to improve the process profit in about 3%, equivalent to 2 million dollars per year; and the integration of SOC and RTO may be an interesting control alternative for the VRD process.
Resumo:
Robotics is a field that presents a large number of problems because it depends on a large number of disciplines, devices, technologies and tasks. Its expansion from perfectly controlled industrial environments toward open and dynamic environment presents a many new challenges, such as robots household robots or professional robots. To facilitate the rapid development of robotic systems, low cost, reusability of code, its medium and long term maintainability and robustness are required novel approaches to provide generic models and software systems who develop paradigms capable of solving these problems. For this purpose, in this paper we propose a model based on multi-agent systems inspired by the human nervous system able to transfer the control characteristics of the biological system and able to take advantage of the best properties of distributed software systems.
Resumo:
Robotics is an emerging field with great activity. Robotics is a field that presents several problems because it depends on a large number of disciplines, technologies, devices and tasks. Its expansion from perfectly controlled industrial environments toward open and dynamic environment presents a many new challenges. New uses are, for example, household robots or professional robots. To facilitate the low cost, rapid development of robotic systems, reusability of code, its medium and long term maintainability and robustness are required novel approaches to provide generic models and software systems who develop paradigms capable of solving these problems. For this purpose, in this paper we propose a model based on multi-agent systems inspired by the human nervous system able to transfer the control characteristics of the biological system and able to take advantage of the best properties of distributed software systems. Specifically, we model the decentralized activity and hormonal variation.
Resumo:
El objetivo de este trabajo es analizar cómo la dictadura de Primo de Rivera llevó a cabo la reforma de la enseñanza industrial del joven obrero a través del Estatuto de Enseñanza Industrial de 1924 y del Estatuto de Formación Profesional de 1928, dentro de la órbita ideológica del “modernismo reaccionario”. La dictadura primorriverista se encontraba en una época influida por las consecuencias de la Gran Guerra y empezaba a percibir la formación profesional técnica-industrial como un mecanismo de adoctrinamiento de la juventud obrera, a partir del cual se podía construir una identidad nacional y profesional, a la vez que modernizar la industria nacional. Por ello, la dictadura de Primo de Rivera decidió centralizar todos los canales de formación industrial del joven obrero a través de un nuevo plan de estudios técnico e industrial dentro de las escuelas industriales y de trabajo. Así intentaba controlar al movimiento obrero, formar una clase media de técnicos industriales, satisfacer las necesidades económicas del país, al mismo tiempo que mantener la jerarquización socio-política tradicional. Pero la aplicación de este proyecto educativo durante la Segunda República no cumplió con las expectativas ideológicas y políticas de la dictadura de Primo de Rivera.
Resumo:
Binary and ternary combinations of sewage sludge ash (SSA) with marble dust (MD), fly ash (FA) and rice husk ash (RHA) as replacement in Portland cement pastes, were assessed. Several tests were carried out at different curing ages: thermogravimetry, density, water absorption, ultrasonic pulse velocity and mechanical strengths. Pozzolanic effects of the mineral admixtures, densities similar to control sample and improved absorptions when combining waste materials were identified. In general, the compressive strength reaches or exceeds the cement strength class, and blending SSA, FA and RHA (30% cement replacement) increase of strength by 9%, compared to the control sample, was achieved.
Resumo:
Issued July 1978.