992 resultados para Enamel and enameling.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to assess the enamel microhardness treated with three in-office bleaching agents, containing 35% hydrogen peroxide with different acidity. Materials and methods. Bovine incisors were divided into three groups that received the following bleaching agents: Whiteness HP, Total Bleach and Opalescence Xtra. Three gel applications/10-min each, totaling 30-min of bleaching treatment, were made on the teeth and activated with a blue LED (1000 mW/470 nm) combined to a LASER (120 mW/795 nm) device (Easy Bleach-Clean Line). Vickers hardness (VH) was evaluated at baseline and after the bleaching procedure. The values of Hardness loss [HNL] (% reduction) were calculated. The two-sample t-test was used for comparison of the HNL of the three bleaching products (5% level of significance). Results. The Opalescence Xtra, which had the lowest pH value (pH = 4.30), showed a significant increase of HNL when compared with Total Bleach bleaching agent, which had the highest pH value (pH = 6.62). Conclusions. The 35% hydrogen peroxide bleaching agents resulted in a reduction in surface enamel microhardness and bleaching with the most acid agent resulted in a significant enamel hardness loss compared to the less acid agent (4.30 vs 6.62). Strategies proposed to reduce the enamel loss after bleaching treatment may include the use of daily fluoride therapy, mouth rinsing (fluoride, milk and sodium bicarbonate solution), fluoride/bicarbonate dentifrices without abrasives, do not toothbrush immediately after bleaching, fluorides and calcium add to bleaching agents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two self-etching primers (P) and two all-in-one self-etching adhesives (S). Method: Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to the adhesive system.. SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (inner diameter of 0.8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37 degrees C for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test (a=5%). Samples were also subjected to stereomicroscopic and SEM evaluations after micro-shear testing. Mean bond strength values (MPa +/- SD) and the results of Tukey test were: SB2: 36.36(+/- 3.34)a; ADS: 33.03(+/- 7.83)a; XE3: 32.76(+/- 5.61)a; CSE: 30.61(+/- 6.68)a; PLP: 22.17(+/- 6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others. J Clin Pediatr Dent 35(3): 301-304, 2011

Relevância:

30.00% 30.00%

Publicador:

Resumo:

International Journal of Paediatric Dentistry 2012; 22: 435441 Background. Hydrophilic adhesives may be used as pit and fissure sealants (sealants), but there is concern about the ability of self-etching adhesives to bond sealants to enamel. Aim. To study the bond strength (BS) and morphology of adhesive systems used as sealants. Design. OptiBond FL, OptiBond All-in-One, combined OptiBond All-in-One + OptiBond FL adhesive, and Fluroshield were applied to the occlusal surfaces of 16 primary molars (n = 4). Teeth were stored in distilled water (24 h at 37 degrees C) and sectioned through the interface to obtain sticks (0.8 mm2) tested under a tensile load (0.5 mm/min). Failure modes were observed. Data were analysed by ANOVA and Tukeys tests (a = 5%). The morphology of 12 primary molars was examined in terms of the etching pattern and resin reproduction. Results. Differences in the BS were found (P = 0.001), with OptiBond FL showing the highest (36.84 +/- 5.7 MPa), Fluroshield (24.26 +/- 2.13 MPa) and OptiBond All-in-One (17.12 +/- 4.97 MPa) similar, and OptiBond All-in-One + OptiBond FL adhesive the lowest (9.8 +/- 2.94 MPA). OptiBond FL showed the best results in terms of morphology. Conclusion. Under the conditions of this study, OptiBond FL was the best material to be used for sealing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this in vitro study was to evaluate alterations in the surface roughness and micromorphology of human enamel submitted to three prophylaxis methods. Sixty-nine caries-free molars with exposed labial surfaces were divided into three groups. Group I was treated with a rotary instrument set at a low speed, rubber clip and a mixture of water and pumice; group II with a rotary instrument set at a low speed, rubber cup and prophylaxis paste Herjos-F (Vigodent S/A Industria e Comercio, Rio de Janeiro, Brazil); and group III with sodium bicarbonate spray Profi II Ceramic (Dabi A dante Indtistrias Medico Odontologicas Ltda, Ribeirao Preto, Brazil). All procedures were performed by the same operator for 10 s, and samples were rinsed and stored in distilled water. Pre and post-treatment surface evaluation was completed using a surface profilometer (Perthometer S8P Marh, Perthen, Germany) in 54 samples. In addition, the other samples were coated with gold and examined in a scanning electron microscope (SEM). The results of this study were statistically analyzed with the paired t-test (Student), the Kruskal-Wallis test and the Dunn (5%) test. The sodium bicarbonate spray led to significantly rougher surfaces than the pumice paste. The use of prophylaxis paste showed no statistically significant difference when compared with the other methods. Based on SEM analysis, the sodium bicarbonate spray presented an irregular surface with granular material and erosions. Based on this study, it can be concluded that there was an increased enamel stuface roughness when teeth were treated with sodium bicarbonate spray when compared with teeth treated with pumice paste.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo in vitro foi de avaliar ao microscópio eletrônico de varredura os aspectos morfológicos do esmalte de dentes decíduos após condicionamento com ácido fosfórico a 36% ou com um agente condicionador não lavável. Foram selecionados 10 dentes decíduos anteriores esfoliados naturalmente. As amostras sofreram limpeza coronária com pasta de pedra-pomes e água, em baixa-velocidade. O condicionamento foi realizado no esmalte da face vestibular. Os espécimes foram divididos em dois grupos: G1 (n=10): condicionamento com ácido fosfórico a 36% na forma de gel - Conditioner 36 (Dentsply) durante 20 segundos, seguidos de lavagem com água durante 15 segundos; G2 (n=10): condicionamento com NRC - Non Rinse Conditioner (Dentsply) durante 20 segundos, seguidos de secagem com ar durante 15 segundos. As amostras foram desidratadas, montadas em bases metálicas e cobertas com ouro para análise ao microscópio eletrônico de varredura (Jeol JSM 6.100). A análise da eletromicrografias revelou que ambos os agentes condicionadores foram efetivos para condicionar o esmalte de dentes decíduos, causando microporosidades mas com melhor resultado quando utilizou-se o ácido fosfórico a 36% na forma de gel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the microhardness of enamel treated with two different 10% carbamide peroxide bleaching materials at different time intervals. Materials and Methods: Two bleaching agents were analyzed: Opalescence (OPA) and Rembrandt (REM). The control group (CON) consisted of dental fragments maintained in artificial saliva. Bleaching was accomplished for 8 hrs per day and stored during the remaining time in an individual recipient with artificial saliva. Enamel microhardness testing was performed before the initial exposure to the treatments and after 1, 7, 14, 21, 28, 35 and 42 days. Results: the ANOVA, followed by the Bartlet and Tukey tests, showed significant differences for treatments (P < 0.00001) from day 7-day 42. From the 7th to the 14th day, OPA presented an increase of enamel microhardness over time while REM presented a decrease of microhardness. Statistical differences were not found between REM and the control group (OPA > CON = REM). From the 21st-35th day, enamel fragments bleached with OPA and REM presented a decrease of microhardness. Statistical differences of microhardness were verified among all the treatments (OPA > CON > REM). on the day 42, statistical differences were not found between OPA and the control group, but they were found between REM and the control group (OPA = CON > REM). The polynomial regression showed an increase of microhardness for OPA until the 21st day, followed by a decrease of microhardness up to the 42nd day. A decrease of microhardness for REM was verified. There were alterations in enamel microhardness as a function of bleaching time when using the two different 10% carbamide peroxide whiteners. Over a 42-day treatment time, bleaching with REM agent caused a decrease in enamel microhardness. The OPA agent initially increased the microhardness, then returned to the control level. Different bleaching materials with the same concentration of carbamide peroxide have different effects on the enamel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem. During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis.Purpose. The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser.Material and methods. Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark oil the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degreesC). Analysis was performed on the following groups (n = 10): Group 1, high-speed handpiece without water cooling, Group 11, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 mum at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha = .05).Results. The average temperature rises were: 11.64degreesC (+/-4.35) for Group 1, 0.96degreesC (+/-0.71) for Group 11, and 2.69degreesC (+/-1.12) for Group III. There were no statistical differences between Groups 11 and III, both 11 and III differed from Group I significantly (P = .000 and P = .002, respectively).Conclusion. The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the pulp chamber penetration of peroxide bleaching agent in human and bovine teeth after office bleach technique. All the teeth were sectioned 3 mm apical of the cement-enamel junction and were divided into 2 groups, A (70 third human molars) and B (70 bovine lateral incisors), that were subdivided into A1 and B1 restored by using composite resin, A2 and B2 by using glass ionomer cement, and A3 and B3 by using resin-modified glass ionomer cement; A4, A5, B4, and B5 were not restored. Acetate buffer was placed in the pulp chamber, and the bleaching agent was applied for 40 minutes as follows: A1-A4 and B1-B4, 38% hydrogen peroxide exposure and A5 and B5, immersion into distilled water. The buffer solution was transferred to a glass tube in which leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to analysis of variance and Dunnett, Kruskal-Wallis, and Tukey tests (5%). A higher level of hydrogen peroxide penetrated into the pulp chamber in resin-modified glass ionomer cements in bovine (0.79 +/- 0.61 mu g) and human (2.27 +/- 0.41 mu g) groups. The bleaching agent penetration into the pulp chamber was higher in human teeth for any experimental situation. The penetration of the hydrogen peroxide depends on restorative materials, and under the conditions of this study human teeth are more susceptible to penetration of bleaching agent into the pulp chamber than bovine teeth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This in situ/ex vivo study assessed the effect of fluoride dentifrice on eroded enamel subjected to brushing abrasion. In a crossover study performed in 2 phases, 10 volunteers wore acrylic palatal appliances, each containing 3 human enamel blocks. Dentifrice was used to brush the volunteers' teeth and the specimens subjected to abrasion. In phases A and B the dentifrices used had the same formulation, except for the absence or presence of fluoride, respectively. The blocks were subjected to erosion by immersion of the appliances in a cola drink for 5 min, 4 times a day. Then the blocks were brushed, and the appliance was replaced into the mouth. Enamel alterations were determined using profilometry and percentage change in surface microhardness (%SMHC) tests. The data were tested using the paired t test. The mean wear values (+/- SD, mu m) were: group A 6.84 +/- 1.72 and group B 5.38 +/- 1.21 (p = 0.04). The mean %SMHC values (+/- SD) were: group A 54.6 +/- 16.2 and group B 45.7 +/- 6.8 (p = 0.04). Fluoride dentifrice had a protective effect on eroded enamel subjected to brushing abrasion. Copyright (c) 2007 S. Karger AG, Basel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This study investigated the influence of the period after ovariectomy on femoral and mandibular bone mineral density (BMD) and on induced periodontal disease.Methods: One hundred and twenty-six female Holtzman rats were divided into nine groups: control, sham surgery (SHAM) with and without induction of periodontal disease for 51 and 150 days, and ovariectomy (OVX) with and without induction of periodontal disease for 51 and 150 days. Periodontal disease was induced by placing ligatures on the first lower molars during the last 30 days of each period. BMD was measured by dual-energy x-ray absorptiometry. Vertical bone loss was determined by measuring the distance from the alveolar bone crest to the cemento-enamel junction on the mesial side of the first lower molar.Results: Statistical analyses (Kruskal-Wallis test) revealed a significant difference between the OVX and SHAM groups' global and femoral proximal epiphysis BMD (P < 0.001) for 150 days and in the global evaluation for 51 days. For mandibular BMD, no difference was found between the groups of each period. Influence of the period on femoral BMD was found only for the SHAM groups, with lower BMD for the 51-day period compared to the 150-day period (P < 0.05). In the global evaluation of the mandible, a lower BMD was found after 51 days. The period was a contributing factor for the vertical bone loss, and it resulted in higher values for the 51-day period (P < 0.05).Conclusion: the period influenced the femoral BMD and the vertical bone loss in induced periodontal disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of various bleaching agents on the cemento-enamel junction (CEJ) of human teeth by scanning electron microscopy (SEM) analysis. Methods: 30 intact teeth were selected and longitudinally sectioned, yielding 60 specimens. Thirty specimens served as controls; the other 30 were divided into six groups with five specimens each (n= 5) and bleached according to six protocols (Group 1: External bleaching with 10% carbamide peroxide; Group 2: External bleaching with 35% hydrogen peroxide; Group 3: External bleaching with 35% hydrogen peroxide; Group 4: Internal/external bleaching with 35% hydrogen peroxide; Group 5: Internal/external bleaching with 35% hydrogen peroxide; and Group 6: Intracoronal bleaching with a paste of sodium perborate mixed with 9% hydrogen peroxide). After treatment the specimens were prepared and examined in a scanning electron microscope. Results: the bleaching agents used in this study caused morphological changes in the CEJ and increased dentin exposure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When the carious tissue is eliminated either by conventional methods (with burs) or with lasers, the risk of accidentally damage the surface of adjacent teeth may occur, which hypothetically could lead to a more susceptible surface for canes formation. This in vitro study aims to evaluate the caries resistance of the dental enamel surface irradiated by the Nd:YAG laser applied in conditions simulating accidental exposition. Thirteen third molars were used in this study. The experimental groups were: G1: sound control and control + carious; G2: contact Nd:YAG laser at 0.75, 1, 2, or 3 W; 10 Hz; 3 sec (27, 35, 71, and 106 J/cm(2)); G3: same parameters from G2 + caries artificial induction through the demineralization and demineralization (DES/RE) dynamic model. The caries resistance analysis was evaluated by the superficial morphological aspect through SEM images and also by Ca/P proportion through energy dispersive X-ray spectroscopy (EDX). The micrograph images showed that the Nd:YAG laser changed the normalmorphology of the enamel prisms resulting in a melted and re-solidified surface intensified with the power increase. Significant statistical differences were observed applying the Kruskal-Wallis statistical test (p <= 0.01) among the Nd:YAG laser irradiated groups and the control with caries regarding the Ca/P proportion. As an exception, this was not observed when 3 W; 10 Hz; 3 sec; 106 J/cm(2) was applied and posteriously submitted to a cariogenic challenge. The results indicate that the Nd:YAG laser accidental irradiation at low power settings did not represent risks to the enamel caries resistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the presence of enamel alterations in deciduous maxillary central incisors of infants with unilateral cleft lip and alveolar ridge, with or without cleft palate, and to compare the occurrence and location of these alterations between the central incisor adjacent to the cleft and the contralateral incisor.Design: Intraoral clinical examination was performed after tooth cleaning and drying by a single examiner with the aid of a dental mirror, dental probe, and artificial light, with the child positioned on a dental chair. The defects were recorded in a standardized manner according to the criteria of the Modified Developmental Defects of Enamel Index.Setting: Hospital for Rehabilitation of Craniofacial Anomalies (HRAC) at Bauru, São Paulo, Brazil.Patients: One hundred one infants were evaluated. All were white, of both genders, aged 12 to 36 months and had at least two thirds of the crowns of maxillary incisors erupted.Results: Demarcated opacity was the most common defect at both cleft and noncleft sides, followed by diffuse opacity. The occurrence of hypoplasia at the cleft side was 11.8%. Most defects affected less than one third of the crown.Conclusion: The occurrence of enamel defects in deciduous maxillary central incisors of patients with unilateral cleft lip was 42.6%, mainly affecting the cleft side as to both number and severity.