930 resultados para Electrical Impedance Tomography, Rats, Ventilation, Ventilation Distribution, Intensive Care


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION. Both hypocapnia and hypercapnia can be deleterious to brain injured patients. Strict PaCO2 control is difficult to achieve because of patient's instability and unpredictable effects of ventilator settings changes. OBJECTIVE. The aim of this study was to evaluate our ability to comply with a protocol of controlled mechanical ventilation (CMV) aiming at a PaCO2 between 35 and 40 mmHg in patients requiring neuro-resuscitation. METHODS. Retrospective analysis of consecutive patients (2005-2011) requiring intracranial pressure (ICP) monitoring for traumatic brain injury (TBI), subarachnoid haemorrhage (SAH), intracranial haemorrhage (ICH) or ischemic stroke (IS). Demographic data, GCS, SAPS II, hospital mortality, PaCO2 and ICP values were recorded. During CMV in the first 48 h after admission, we analyzed the time spent within the PaCO2 target in relation to the presence or absence of intracranial hypertension (ICP[20 mmHg, by periods of 30 min) (Table 1). We also compared the fraction of time (determined by linear interpolation) spent with normal, low or high PaCO2 in hospital survivors and non-survivors (Wilcoxon, Bonferroni correction, p\0.05) (Table 2). PaCO2 samples collected during and after apnoea tests were excluded. Results given as median [IQR]. RESULTS. 436 patients were included (TBI: 51.2 %, SAH: 20.6 %, ICH: 23.2 %, IS: 5.0 %), age: 54 [39-64], SAPS II score: 52 [41-62], GCS: 5 [3-8]. 8744 PaCO2 samples were collected during 150611 h of CMV. CONCLUSIONS. Despite a high number of PaCO2 samples collected (in average one sample every 107 min), our results show that patients undergoing CMV for neuro- resuscitation spent less than half of the time within the pre-defined PaCO2 range. During documented intracranial hypertension, hypercapnia was observed in 17.4 % of the time. Since non-survivors spent more time with hypocapnia, further analysis is required to determine whether hypocapnia was detrimental per se, or merely reflects increased severity of brain insult.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION. The role of turbine-based NIV ventilators (TBV) versus ICU ventilators with NIV mode activated (ICUV) to deliver NIV in case of severe respiratory failure remains debated. OBJECTIVES. To compare the response time and pressurization capacity of TBV and ICUV during simulated NIV with normal and increased respiratory demand, in condition of normal and obstructive respiratory mechanics. METHODS. In a two-chamber lung model, a ventilator simulated normal (P0.1 = 2 mbar, respiratory rate RR = 15/min) or increased (P0.1 = 6 mbar, RR = 25/min) respiratory demand. NIV was simulated by connecting the lung model (compliance 100 ml/mbar; resistance 5 or 20 l/mbar) to a dummy head equipped with a naso-buccal mask. Connections allowed intentional leaks (29 ± 5 % of insufflated volume). Ventilators to test: Servo-i (Maquet), V60 and Vision (Philips Respironics) were connected via a standard circuit to the mask. Applied pressure support levels (PSL) were 7 mbar for normal and 14 mbar for increased demand. Airway pressure and flow were measured in the ventilator circuit and in the simulated airway. Ventilator performance was assessed by determining trigger delay (Td, ms), pressure time product at 300 ms (PTP300, mbar s) and inspiratory tidal volume (VT, ml) and compared by three-way ANOVA for the effect of inspiratory effort, resistance and the ventilator. Differences between ventilators for each condition were tested by oneway ANOVA and contrast (JMP 8.0.1, p\0.05). RESULTS. Inspiratory demand and resistance had a significant effect throughout all comparisons. Ventilator data figure in Table 1 (normal demand) and 2 (increased demand): (a) different from Servo-i, (b) different from V60.CONCLUSION. In this NIV bench study, with leaks, trigger delay was shorter for TBV with normal respiratory demand. By contrast, it was shorter for ICUV when respiratory demand was high. ICUV afforded better pressurization (PTP 300) with increased demand and PSL, particularly with increased resistance. TBV provided a higher inspiratory VT (i.e., downstream from the leaks) with normal demand, and a significantly (although minimally) lower VT with increased demand and PSL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Because it decreases intubation rate and mortality, NIV has become first-line treatment in case of hypercapnic acute respiratory failure (HARF). Whether this approach is equally successful for all categories of HARF patients is however debated. We assessed if any clinical characteristics of HARF patients were associated with NIV intensity, success, and outcome, in order to identify prognostic factors. Methods Retrospective analysis of the clinical database (clinical information system and MDSi) of patients consecutively admitted to our medico-surgical ICU, presenting with HARF (defined as PaCO2 > 50 mmHg), and receiving NIV between May 2008 and December 2010. Demographic data, medical diagnoses (including documented chronic lung disease), reason for ICU hospitalization, recent surgical interventions, SAPS II and McCabe scores were extracted from the database. Total duration of NIV and the need for tracheal intubation during the 5 days following the first hypercapnia documentation, as well as ICU, hospital and one year mortality were recorded. Results are reported as median [IQR]. Comparisons were carried out with Chi2 or Kruskal-Wallis tests, p<0.05 (*). Results Two hundred and twenty patients were included. NIV successful patients received 16 [9-31] hours of NIV for up to 5 days. Fifty patients (22.7%) were intubated 11 [2-34] hours after HARF occurence, after having receiving 10 [5-21] hours of NIV. Intubation was correlated with increased ICU (18% vs. 6%, p<0.05) and hospital (42% vs. 31%, p>0.05) mortality. SAPS II score was related to increasing ICU (51 [29-74] vs. 23 [12-41]%, p<0.05), hospital (37% [20-59] vs 20% [12-37], p<0.05) and one year mortality (35% vs 20%, p<0.05). Surgical patients were less frequent among hospital fatalities (28.8% vs. 46.3%, p<0.05, RR 0.8 [0-6-0.9]). Nineteen patients (8.6%) died in the ICU, 73 (33.2%) during their hospital stay and 108 (49.1%) were dead one year after HARF. Conclusion The practice to start NIV in all suitable patients suffering from HARF is appropriate. NIV can safely and appropriately be used in patients suffering from HARF from an origin different from COPD exacerbation. Beside usual predictors of severity such as severity score (SAPS II) appear to be associated with increased mortality. Although ICU mortality was low in our patients, hospital and one year mortality were substantial. Surgical patients, although undergoing a similar ICU course, had a better hospital and one year outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Increased respiratory pattern variability is associated with improved oxygenation. Pressure support (PS) is a widely used partial-assist mechanical ventilation (MV) mode, in which each breathing cycle is initiated by flow or pressure variation at the airway due to patient inspiratory effort. Neurally adjusted ventilatory assist (NAVA) is relatively new and uses the electrical activity of the diaphragm (Eadi) to deliver ventilatory support proportional to the patient's inspiratory demand. We hypothesize that respiratory variability should be greater with NAVA compared with PS.Methods: Twenty-two patients underwent 20 minutes of PS followed by 20 minutes of NAVA. Flow and Eadi curves were used to obtain tidal volume (Vt) and ∫Eadi for 300 to 400 breaths in each patient. Patient-specific cumulative distribution functions (CDF) show the percentage Vt and ∫Eadi within a clinically defined (±10%) variability band for each patient. Values are normalized to patient-specific medians for direct comparison. Variability in Vt (outcome) is thus expressed in terms of variability in ∫Eadi (demand) on the same plot.Results: Variability in Vt relative to variability in ∫Eadi is significantly greater for NAVA than PS (P = 0.00012). Hence, greater variability in outcome Vt is obtained for a given demand in ∫Eadi, under NAVA, as illustrated in Figure 1 for a typical patient. A Fisher 2 × 2 contingency analysis showed that 45% of patients under NAVA had a Vt variability in equal proportion to ∫Eadi variability, versus 0% for PS (P < 0.05).Conclusions: NAVA yields greater variability in tidal volume, relative to ∫Eadi demand, and a better match between Vt and ∫Eadi. These results indicate that NAVA could achieve improved oxygenation compared with PS when sufficient underlying variability in ∫Eadi is present, due to its ability to achieve higher tidal volume variability from a given variability in ∫Eadi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of nursing on the duration of weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease. DESIGN: Data were collected prospectively over a 1-yr period (study year) and compared with previously collected prospective data recorded in our chronic obstructive pulmonary disease database during a 5-yr period. SETTING: The medical intensive care unit (ICU) of a university hospital. PATIENTS: Eighty-seven patients with chronic obstructive pulmonary disease. Fifteen patients had chronic obstructive pulmonary disease that required mechanical ventilation for acute exacerbation of their disease (study year), and 72 were patients with chronic obstructive pulmonary disease from the previously collected data. INTERVENTIONS: The ICU course (duration of mechanical ventilation, mortality) was recorded, as well as several respiratory parameters (pulmonary function tests and arterial blood gases in stable conditions, and nutritional status), and they were compared with an "index of nursing." MEASUREMENTS AND MAIN RESULTS: We developed an "index of nursing", comparing the effective workforce of the nurses (number and qualifications) with the ideal workforce required by the number of patients and the severity of their diseases. A value of 1.0 represented a perfect match between the needed and the effectively present nurses, whereas a lesser value signified a diminished available workforce. This index was compared with the complications and duration of weaning from mechanical ventilation. During the first 5 yrs, the duration of mechanical ventilation increased progressively from 7.3 +/- 8.0 to 38.2 +/- 25.8 days (p = .006). A significant inverse correlation between the duration of mechanical ventilation and the nursing index (p = .025) was found. In the sixth comparative year, the number of nurses increased (nursing index = 1.05) and the duration of mechanical ventilation decreased to 9.9 +/- 13 days (p < .001, yr 5 vs. yr 6). CONCLUSIONS: The quality of nursing appears to be a measurable and critical factor in the weaning from mechanical ventilation of patients with chronic obstructive pulmonary disease. Below a threshold in the available workforce of ICU nurses, the weaning duration of patients with chronic obstructive pulmonary disease increases dramatically. Therefore, very close attention should be given to the education and number of ICU nurses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the feasibility and effects of non-invasive pressure support ventilation (NIV) on the breathing pattern in infants developing respiratory failure after extubation. DESIGN: Prospective pilot clinical study; each patient served as their own control. SETTING: A nine-bed paediatric intensive care unit of a tertiary university hospital. PATIENTS: Six patients (median age 5 months, range 0.5-7 months; median weight 4.2 kg, range 3.8-5.1 kg) who developed respiratory failure after extubation. INTERVENTIONS: After a period of spontaneous breathing (SB), children who developed respiratory failure were treated with NIV. MEASUREMENTS AND RESULTS: Measurements included clinical dyspnoea score (DS), blood gases and oesophageal pressure recordings, which were analysed for respiratory rate (RR), oesophageal inspiratory pressure swing (dPes) and oesophageal pressure-time product (PTPes). All data were collected during both periods (SB and NIV). When comparing NIV with SB, DS was reduced by 44% (P < 0.001), RR by 32% (P < 0.001), dPes by 45% (P < 0.01) and PTPes by 57% (P < 0.001). A non-significant trend for decrease in PaCO(2) was observed. CONCLUSION: In these infants, non-invasive pressure support ventilation with turbine flow generator induced a reduction of breathing frequency, dPes and PTPes, indicating reduced load of the inspiratory muscles. NIV can be used with some benefits in infants with respiratory failure after extubation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Positive pressure ventilation (PPV) is a frequent intervention in the neonatal intensive care unit. This article is directed towards paediatricians in training and attempts to cover the basics of PPV without being too technical. To do so we have employed an extensive use of graphics to illustrate the underlying principles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans le contexte d'un climat de plus en plus chaud, une étude « géosystémique » de la répartition du pergélisol dans l'ensemble d'un versant périglaciaire alpin, de la paroi rocheuse jusqu'au glacier rocheux, s'avère primordiale. S'insérant dans cette problématique, ce travail de thèse vise comme objectif général l'étude des versants d'éboulis situés à l'intérieur de la ceinture du pergélisol discontinu selon deux volets de recherche différents : une étude de la stratigraphie et de la répartition du pergélisol dans les éboulis de haute altitude et des processus qui lui sont associés ; une reconstitution de l'histoire paléoenvironnementale du domaine périglaciaire alpin pendant le Tardiglaciaire et l'Holocène. La stratigraphie et la répartition spatiale du pergélisol a été étudiée dans cinq éboulis des Alpes Valaisannes (Suisse), dont trois ont fait l'objet de forages profonds, grâce à la prospection géophysique de détail effectuée à l'aide de méthodes thermiques, de résistivité, sismiques et nucléaires. Les mesures effectuées ont permis de mettre en évidence que, dans les cinq éboulis étudiés, la répartition du pergélisol est discontinue et aucun des versants n'est intégralement occupé par du pergélisol. En particulier, il a été possible de prouver de manière directe que, dans un éboulis, le pergélisol est présent dans les parties inférieures du versant et absent dans les parties supérieures. Trois facteurs de contrôle principaux de la répartition du pergélisol déterminée au sein des éboulis étudiés ont été individualisés, pouvant agir seuls ou de manière combinée : la ventilation ascendante, l'augmentation de la granulométrie en direction de l'aval et la redistribution de la neige par le vent et les avalanches. Parmi ceux-ci, la relation ventilation-granulométrie semble être le facteur de contrôle principal permettant d'expliquer la présence de pergélisol dans les parties inférieures d'un éboulis et son absence dans les parties supérieures. Enfin, l'analyse de la structure des éboulis périglaciaires de haute altitude a permis de montrer que la stratigraphie du pergélisol peut être un élément important pour l'interprétation de la signification paléoclimatique de ce type de formes. Pour le deuxième volet de la recherche, grâce aux datations relatives effectuées à l'aide de l'utilisation conjointe de la méthode paléogéographique et du marteau de Schmidt, il a été possible de définir la chrono-stratigraphie du retrait glaciaire et du développement des glaciers rocheux et des versants d'éboulis des quatre régions des Alpes suisses étudiées (régions du Mont Gelé - Mont Fort, des Fontanesses et de Chamosentse, dans les Alpes Valaisannes, et Massif de la Cima di Gana Bianca, dans les Alpes Tessinoises). La compilation de toutes les datations effectuées a permis de montrer que la plupart des glaciers rocheux actifs étudiés se seraient développés soit juste avant et/ou pendant l'Optimum Climatique Holocène de 9.5-6.3 ka cal BP, soit au plus tard juste après cet évènement climatique majeur du dernier interglaciaire. Parmi les glaciers rocheux fossiles datés, la plupart aurait commencé à se former dans la deuxième moitié du Tardiglaciaire et se serait inactivé dans la première partie de l'Optimum Climatique Holocène. Pour les éboulis étudiés, les datations effectuées ont permis d'observer que leur surface date de la période entre le Boréal et l'Atlantique récent, indiquant que les taux d'éboulisation après la fin de l'Optimum Climatique Holocène ont dû être faibles, et que l'intervalle entre l'âge maximal et l'âge minimal est dans la plupart des cas relativement court (4-6 millénaires), indiquant que les taux d'éboulisation durant la période de formation des éboulis ont dû être importants. Grâce au calcul des taux d'érosion des parois rocheuses sur la base du volume de matériaux rocheux pour quatre des éboulis étudiés, il a été possible mettre en évidence l'existence d'une « éboulisation parapériglaciaire » liée à la dégradation du pergélisol dans les parois rocheuses, fonctionnant principalement durant les périodes de réchauffement climatique rapide comme cela a été le cas au début du Bølling, du Préboréal à la fin de l'Atlantique récent et, peut-être, à partir des années 1980. - In the context of a warmer climate, a « geosystemical » study of the permafrost distribution in a whole alpine periglacial hillslope, from the rockwall to the rockglacier, is of great importance. With respect to this problem, the general objective of this PhD thesis is the global study of talus slopes located within the alpine periglacial belt following two different research axes: the analysis of the internal structure and of the permafrost distribution of high altitude talus slopes and of the related processes; the reconstruction of the palaeoenvironmental history of the alpine periglacial belt during the Lateglacial and the Holocene. The stratigraphy and the permafrost distribution were studied in five talus slopes of the Valais Alps (Switzerland) with the analysis of borehole data (on three of the five talus slopes) and other methods of permafrost prospecting: Electrical Resistivity Tomography (ERT), Refraction Seismic Tomography (RST) and nuclear well logging. The collected data shows that, in all of the studied talus slopes, permafrost distribution is discontinuous and that neither of the hillslopes is integrally characterised by permafrost. In particular, this data proves by direct investigations that, in talus slopes, permafrost is present in the lower parts of the hillslope, whereas it is absent in the upper parts. Permafrost distribution in alpine talus slopes is depending of the combination of almost three controlling factors, whose respective importance is variable: the chimney effect, the increase of grain size downslope and the redistribution of snow by avalanches. Depending on the size of the talus and on topographical and geomorphological heterogeneities, various cases are possible: one dominant controlling factor or the combination of various factors. Nevertheless, it would be an error to consider each controlling factor independently, without considering their relationships. Between these controlling factors, the relationship chimney effect/grain size seems to be the most important factor controlling the presence of permafrost in the lowest part of periglacial talus slopes, and its absence in the upper parts. Finally, the analysis of the talus structure shows that the permafrost stratigraphy may be an important element of interpretation of the palaeoclimatic significance of an alpine talus slope. The second research axe focused on the establishment of a chronology of the Lateglacial glacier retreat and the dating of rockglaciers and talus slopes development in four studied regions of the Swiss Alps (Mont Gelé - Mont Fort, Fontanesses and Chamosentse regions, in the Valais Alps, and the Cima di Gana Bianca Massif, in the Ticino Alps). The compilation of the dates acquired through the combination of the palaeogeographical method and of the Schmidt hammer indicates that most of the investigated active rockglaciers started to evolve during the early phases of the Holocene or, at the latest, after the early-to-mid Holocene Climatic Optimum (ending around 6.3 ka cal BP). For the dated relict rockglaciers, most of them started to evolve in the second half of the Lateglacial, and probably became inactive at the beginning of the Holocene Climatic Optimum. For the investigated talus slopes, the relative dating carried out allowed to show that their surface date from the period included between the Boreal and the end of the Atlantic, pointing out that the rockwall retreat after the end of the Holocene Climatic Optimum was weak, and that the interval between maximal and minimal ages is in most cases relatively short (4-6 millennia). Therefore, the rockwall retreat during the development period of the talus slopes must has been considerable. Thanks to the calculation of rockwall erosion rates based on the volume of talus accumulations for four of the investigated hillslopes, it was possible to find evidences of the existence of "paraperiglacial rockfall phases" related to the permafrost degradation in rockwalls. These phases coincide with rapid climate warming periods, as at the beginning of the Bølling, during the Preboreal or, maybe, since 1980.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High frequency oscillatory ventilation (HFOV) is becoming an increasingly popular intervention in the neonatal intensive care unit. This article will attempt to explain the principles of HFOV. It is inherently more difficult to become skilled in this technique than in other forms of mechanical ventilation, so caution is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the impact of noninvasive ventilation (NIV) algorithms available on intensive care unit ventilators on the incidence of patient-ventilator asynchrony in patients receiving NIV for acute respiratory failure. Prospective multicenter randomized cross-over study. Intensive care units in three university hospitals. Patients consecutively admitted to the ICU and treated by NIV with an ICU ventilator were included. Airway pressure, flow and surface diaphragmatic electromyography were recorded continuously during two 30-min periods, with the NIV (NIV+) or without the NIV algorithm (NIV0). Asynchrony events, the asynchrony index (AI) and a specific asynchrony index influenced by leaks (AIleaks) were determined from tracing analysis. Sixty-five patients were included. With and without the NIV algorithm, respectively, auto-triggering was present in 14 (22%) and 10 (15%) patients, ineffective breaths in 15 (23%) and 5 (8%) (p = 0.004), late cycling in 11 (17%) and 5 (8%) (p = 0.003), premature cycling in 22 (34%) and 21 (32%), and double triggering in 3 (5%) and 6 (9%). The mean number of asynchronies influenced by leaks was significantly reduced by the NIV algorithm (p < 0.05). A significant correlation was found between the magnitude of leaks and AIleaks when the NIV algorithm was not activated (p = 0.03). The global AI remained unchanged, mainly because on some ventilators with the NIV algorithm premature cycling occurs. In acute respiratory failure, NIV algorithms provided by ICU ventilators can reduce the incidence of asynchronies because of leaks, thus confirming bench test results, but some of these algorithms can generate premature cycling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The continuous intravenous administration of isotopic bicarbonate (NaH13CO2) has been used for the determination of the retention of the 13CO2 fraction or the 13CO2 recovered in expired air. This determination is important for the calculation of substrate oxidation. The aim of the present study was to evaluate, in critically ill patients with sepsis under mechanical ventilation, the 13CO2 recovery fraction in expired air after continuous intravenous infusion of NaH13CO2 (3.8 µmol/kg diluted in 0.9% saline in ddH2O). A prospective study was conducted on 10 patients with septic shock between the second and fifth day of sepsis evolution (APACHE II, 25.9 ± 7.4). Initially, baseline CO2 was collected and indirect calorimetry was also performed. A primer of 5 mL NaH13CO2 was administered followed by continuous infusion of 5 mL/h for 6 h. Six CO2 production (VCO2) measurements (30 min each) were made with a portable metabolic cart connected to a respirator and hourly samples of expired air were obtained using a 750-mL gas collecting bag attached to the outlet of the respirator. 13CO2 enrichment in expired air was determined with a mass spectrometer. The patients presented a mean value of VCO2 of 182 ± 52 mL/min during the steady-state phase. The mean recovery fraction was 0.68 ± 0.06%, which is less than that reported in the literature (0.82 ± 0.03%). This suggests that the 13CO2 recovery fraction in septic patients following enteral feeding is incomplete, indicating retention of 13CO2 in the organism. The severity of septic shock in terms of the prognostic index APACHE II and the sepsis score was not associated with the 13CO2 recovery fraction in expired air.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Des études adultes sur l’œdème pulmonaire lésionnel et le Syndrome de Détresse Respiratoire Aiguë ont mené à l’établissement de recommandations sur les stratégies de ventilation mécanique à employer chez ces patients. Cependant, il n’est pas clair si les recommandations adultes sont également bénéfiques pour l’enfant. Objectif Décrire les stratégies de ventilation mécanique employées chez les enfants atteints d’un œdème pulmonaire lésionnel. Méthodes Étude épidémiologique transversale tenue dans 59 unités de Soins Intensifs Pédiatriques de 12 pays en Amérique du Nord et en Europe. Six jours d’étude ont eu lieu entre juin et novembre 2007. Les enfants atteints d’un œdème pulmonaire lésionnel étaient inclus et des données sur la sévérité de leur maladie, les paramètres de ventilation mécanique et les thérapies adjuvantes employées ont été recueillies. Résultats Des 3823 enfants dépistés, 414 (10.8%) avaient un œdème pulmonaire lésionnel et 165 (40%) ont été inclus dans l’étude (124 étaient sous ventilation mécanique conventionnelle, 27 sous ventilation à haute fréquence par oscillation et 14 sous ventilation non invasive). Dans le groupe sous ventilation conventionnelle, 43.5% étaient ventilés avec un mode contrôlé à pression, le volume courant moyen était de 8.3±3.3 ml/kg et l’utilisation de la PEP et FiO2 était hétérogène. Conclusions Cette étude démontre une hétérogénéité dans les stratégies de ventilation mécanique employées chez les enfants souffrant d’un œdème pulmonaire lésionnel. Celle-ci pourrait être en partie reliée à la robustesse des critères diagnostiques actuellement utilisés pour définir l’ALI/SDRA. Une évaluation rigoureuse de ces stratégies est nécessaire pour guider la standardisation des soins et optimiser l’issue de ces patients.