970 resultados para Electric current measurement
Resumo:
The international growing concern for the human exposure to magnetic fields generated by electric power lines has unavoidably led to imposing legal limits. Respecting these limits, implies being able to calculate easily and accurately the generated magnetic field also in complex configurations. Twisting of phase conductors is such a case. The consolidated exact and approximated theory regarding a single-circuit twisted three-phase power cable line has been reported along with the proposal of an innovative simplified formula obtained by means of an heuristic procedure. This formula, although being dramatically simpler, is proven to be a good approximation of the analytical formula and at the same time much more accurate than the approximated formula found in literature. The double-circuit twisted three-phase power cable line case has been studied following different approaches of increasing complexity and accuracy. In this framework, the effectiveness of the above-mentioned innovative formula is also examined. The experimental verification of the correctness of the twisted double-circuit theoretical analysis has permitted its extension to multiple-circuit twisted three-phase power cable lines. In addition, appropriate 2D and, in particularly, 3D numerical codes for simulating real existing overhead power lines for the calculation of the magnetic field in their vicinity have been created. Finally, an innovative ‘smart’ measurement and evaluation system of the magnetic field is being proposed, described and validated, which deals with the experimentally-based evaluation of the total magnetic field B generated by multiple sources in complex three-dimensional arrangements, carried out on the basis of the measurement of the three Cartesian field components and their correlation with the field currents via multilinear regression techniques. The ultimate goal is verifying that magnetic induction intensity is within the prescribed limits.
Resumo:
One of the most precisely measured quantities in particle physics is the magnetic moment of the muon, which describes its coupling to an external magnetic field. It is expressed in form of the anomalous magnetic moment of the muon a_mu=(g_mu-2)/2 and has been determined experimentally with a precision of 0.5 parts per million. The current direct measurement and the theoretical prediction of the standard model differ by more than 3.5 standard deviations. Concerning theory, the contribution of the QED and weak interaction to a_mu can be calculated with very high precision in a perturbative approach.rnAt low energies, however, perturbation theory cannot be used to determine the hadronic contribution a^had_mu. On the other hand, a^had_mu may be derived via a dispersion relation from the sum of measured cross sections of exclusive hadronic reactions. Decreasing the experimental uncertainty on these hadronic cross sections is of utmost importance for an improved standard model prediction of a_mu.rnrnIn addition to traditional energy scan experiments, the method of Initial State Radiation (ISR) is used to measure hadronic cross sections. This approach allows experiments at colliders running at a fixed centre-of-mass energy to access smaller effective energies by studying events which contain a high-energetic photon emitted from the initial electron or positron. Using the technique of ISR, the energy range from threshold up to 4.5GeV can be accessed at Babar.rnrnThe cross section e+e- -> pi+pi- contributes with approximately 70% to the hadronic part of the anomalous magnetic moment of the muon a_mu^had. This important channel has been measured with a precision of better than 1%. Therefore, the leading contribution to the uncertainty of a_mu^had at present stems from the invariant mass region between 1GeV and 2GeV. In this energy range, the channels e+e- -> pi+pi-pi+pi- and e+e- -> pi+pi-pi0pi0 dominate the inclusive hadronic cross section. The measurement of the process e+e- -> pi+pi-pi+pi- will be presented in this thesis. This channel has been previously measured by Babar based on 25% of the total dataset. The new analysis includes a more detailed study of the background contamination from other ISR and non-radiative background reactions. In addition, sophisticated studies of the track reconstruction as well as the photon efficiency difference between the data and the simulation of the Babar detector are performed. With these auxiliary studies, a reduction of the systematic uncertainty from 5.0% to 2.4% in the peak region was achieved.rnrnThe pi+pi-pi+pi- final state has a rich internal structure. Hints are seen for the intermediate states rho(770)^0 f_2(1270), rho(770)^0 f_0(980), as well as a_1(1260)pi. In addition, the branching ratios BR(jpsi -> pi+pi-pi+pi-) and BR(psitwos -> jpsi pi+pi-) are extracted.rn
Resumo:
The present dissertation aims to explore, theoretically and experimentally, the problems and the potential advantages of different types of power converters for “Smart Grid” applications, with particular emphasis on multi-level architectures, which are attracting a rising interest even for industrial requests. The models of the main multilevel architectures (Diode-Clamped and Cascaded) are shown. The best suited modulation strategies to function as a network interface are identified. In particular, the close correlation between PWM (Pulse Width Modulation) approach and SVM (Space Vector Modulation) approach is highlighted. An innovative multilevel topology called MMC (Modular Multilevel Converter) is investigated, and the single-phase, three-phase and "back to back" configurations are analyzed. Specific control techniques that can manage, in an appropriate way, the charge level of the numerous capacitors and handle the power flow in a flexible way are defined and experimentally validated. Another converter that is attracting interest in “Power Conditioning Systems” field is the “Matrix Converter”. Even in this architecture, the output voltage is multilevel. It offers an high quality input current, a bidirectional power flow and has the possibility to control the input power factor (i.e. possibility to participate to active and reactive power regulations). The implemented control system, that allows fast data acquisition for diagnostic purposes, is described and experimentally verified.
Resumo:
Die elektromagnetischen Nukleon-Formfaktoren sind fundamentale Größen, welche eng mit der elektromagnetischen Struktur der Nukleonen zusammenhängen. Der Verlauf der elektrischen und magnetischen Sachs-Formfaktoren G_E und G_M gegen Q^2, das negative Quadrat des Viererimpulsübertrags im elektromagnetischen Streuprozess, steht über die Fouriertransformation in direkter Beziehung zu der räumlichen Ladungs- und Strom-Verteilung in den Nukleonen. Präzise Messungen der Formfaktoren über einen weiten Q^2-Bereich werden daher für ein quantitatives Verständnis der Nukleonstruktur benötigt.rnrnDa es keine freien Neutrontargets gibt, gestaltet sich die Messung der Neutron-Formfaktoren schwierig im Vergleich zu der Messung am Proton. Konsequenz daraus ist, dass die Genauigkeit der vorhandenen Daten von Neutron-Formfaktoren deutlich geringer ist als die von Formfaktoren des Protons; auch der vermessene Q^2-Bereich ist kleiner. Insbesondere der elektrische Sachs-Formfaktor des Neutrons G_E^n ist schwierig zu messen, da er aufgrund der verschwindenden Nettoladung des Neutrons im Verhältnis zu den übrigen Nukleon-Formfaktoren sehr klein ist. G_E^n charakterisiert die Ladungsverteilung des elektrisch neutralen Neutrons und ist damit besonders sensitiv auf die innere Struktur des Neutrons.rnrnIn der hier vorgestellten Arbeit wurde G_E^n aus Strahlhelizitätsasymmetrien in der quasielastischen Streuung vec{3He}(vec{e}, e'n)pp bei einem Impulsübertrag von Q^2 = 1.58 (GeV/c)^2 bestimmt. Die Messung fand in Mainz an der Elektronbeschleunigeranlage Mainzer Mikrotron innerhalb der A1-Kollaboration im Sommer 2008 statt. rnrnLongitudinal polarisierte Elektronen mit einer Energie von 1.508 GeV wurden an einem polarisierten ^3He-Gastarget, das als effektives, polarisiertes Neutrontarget diente, gestreut. Die gestreuten Elektronen wurden in Koinzidenz mit den herausgeschlagenen Neutronen detektiert; die Elektronen wurden in einem magnetischen Spektrometer nachgewiesen, durch den Nachweis der Neutronen in einer Matrix aus Plastikszintillatoren wurde der Beitrag der quasielastischen Streuung am Proton unterdrückt.rnrnAsymmetrien des Wirkungsquerschnitts bezüglich der Elektronhelizität sind bei Orientierung der Targetpolarisation in der Streuebene und senkrecht zum Impulsübertrag sensitiv auf G_E^n / G_M^n; mittels deren Messung kann G_E^n bestimmt werden, da der magnetische Formfaktor G_M^n mit vergleichsweise hoher Präzision bekannt ist. Zusätzliche Messungen der Asymmetrie bei einer Polarisationsorientierung parallel zum Impulsübertrag wurden genutzt, um systematische Fehler zu reduzieren.rnrnFür die Messung inklusive statistischem (stat) und systematischem (sys) Fehler ergab sich G_E^n = 0.0244 +/- 0.0057_stat +/- 0.0016_sys.
Resumo:
This thesis is focused on Smart Grid applications in medium voltage distribution networks. For the development of new applications it appears useful the availability of simulation tools able to model dynamic behavior of both the power system and the communication network. Such a co-simulation environment would allow the assessment of the feasibility of using a given network technology to support communication-based Smart Grid control schemes on an existing segment of the electrical grid and to determine the range of control schemes that different communications technologies can support. For this reason, is presented a co-simulation platform that has been built by linking the Electromagnetic Transients Program Simulator (EMTP v3.0) with a Telecommunication Network Simulator (OPNET-Riverbed v18.0). The simulator is used to design and analyze a coordinate use of Distributed Energy Resources (DERs) for the voltage/var control (VVC) in distribution network. This thesis is focused control structure based on the use of phase measurement units (PMUs). In order to limit the required reinforcements of the communication infrastructures currently adopted by Distribution Network Operators (DNOs), the study is focused on leader-less MAS schemes that do not assign special coordinating rules to specific agents. Leader-less MAS are expected to produce more uniform communication traffic than centralized approaches that include a moderator agent. Moreover, leader-less MAS are expected to be less affected by limitations and constraint of some communication links. The developed co-simulator has allowed the definition of specific countermeasures against the limitations of the communication network, with particular reference to the latency and loss and information, for both the case of wired and wireless communication networks. Moreover, the co-simulation platform has bee also coupled with a mobility simulator in order to study specific countermeasures against the negative effects on the medium voltage/current distribution network caused by the concurrent connection of electric vehicles.
Resumo:
A permanent electric dipole moment of the neutron violates time reversal as well as parity symmetry. Thus it also violates the combination of charge conjugation and parity symmetry if the combination of all three symmetries is a symmetry of nature. The violation of these symmetries could help to explain the observed baryon content of the Universe. The prediction of the Standard Model of particle physics for the neutron electric dipole moment is only about 10e−32 ecm. At the same time the combined violation of charge conjugation and parity symmetry in the Standard Model is insufficient to explain the observed baryon asymmetry of the Universe. Several extensions to the Standard Model can explain the observed baryon asymmetry and also predict values for the neutron electric dipole moment just below the current best experimental limit of d n < 2.9e−26 ecm, (90% C.L.) that has been obtained by the Sussex-RAL-ILL collaboration in 2006. The very same experiment that set the current best limit on the electric dipole moment has been upgraded and moved to the Paul Scherrer Institute. Now an international collaboration is aiming at increasing the sensitivity for an electric dipole moment by more than an order of magnitude. This thesis took place in the frame of this experiment and went along with the commissioning of the experiment until first data taking. After a short layout of the theoretical background in chapter 1, the experiment with all subsystems and their performance are described in detail in chapter 2. To reach the goal sensitivity the control of systematic errors is as important as an increase in statistical sensitivity. Known systematic efects are described and evaluated in chapter 3. During about ten days in 2012, a first set of data was measured with the experiment at the Paul Scherrer Institute. An analysis of this data is presented in chapter 4, together with general tools developed for future analysis eforts. The result for the upper limit of an electric dipole moment of the neutron is |dn| ≤ 6.4e−25 ecm (95%C.L.). Chapter 5 presents investigations for a next generation experiment, to build electrodes made partly from insulating material. Among other advantages, such electrodes would reduce magnetic noise, generated by the thermal movement of charge carriers. The last Chapter summarizes this work and gives an outlook.
Resumo:
In this thesis the measurement of the effective weak mixing angle wma in proton-proton collisions is described. The results are extracted from the forward-backward asymmetry (AFB) in electron-positron final states at the ATLAS experiment at the LHC. The AFB is defined upon the distribution of the polar angle between the incoming quark and outgoing lepton. The signal process used in this study is the reaction pp to zgamma + X to ee + X taking a total integrated luminosity of 4.8\,fb^(-1) of data into account. The data was recorded at a proton-proton center-of-mass energy of sqrt(s)=7TeV. The weak mixing angle is a central parameter of the electroweak theory of the Standard Model (SM) and relates the neutral current interactions of electromagnetism and weak force. The higher order corrections on wma are related to other SM parameters like the mass of the Higgs boson.rnrnBecause of the symmetric initial state constellation of colliding protons, there is no favoured forward or backward direction in the experimental setup. The reference axis used in the definition of the polar angle is therefore chosen with respect to the longitudinal boost of the electron-positron final state. This leads to events with low absolute rapidity have a higher chance of being assigned to the opposite direction of the reference axis. This effect called dilution is reduced when events at higher rapidities are used. It can be studied including electrons and positrons in the forward regions of the ATLAS calorimeters. Electrons and positrons are further referred to as electrons. To include the electrons from the forward region, the energy calibration for the forward calorimeters had to be redone. This calibration is performed by inter-calibrating the forward electron energy scale using pairs of a central and a forward electron and the previously derived central electron energy calibration. The uncertainty is shown to be dominated by the systematic variations.rnrnThe extraction of wma is performed using chi^2 tests, comparing the measured distribution of AFB in data to a set of template distributions with varied values of wma. The templates are built in a forward folding technique using modified generator level samples and the official fully simulated signal sample with full detector simulation and particle reconstruction and identification. The analysis is performed in two different channels: pairs of central electrons or one central and one forward electron. The results of the two channels are in good agreement and are the first measurements of wma at the Z resonance using electron final states at proton-proton collisions at sqrt(s)=7TeV. The precision of the measurement is already systematically limited mostly by the uncertainties resulting from the knowledge of the parton distribution functions (PDF) and the systematic uncertainties of the energy calibration.rnrnThe extracted results of wma are combined and yield a value of wma_comb = 0.2288 +- 0.0004 (stat.) +- 0.0009 (syst.) = 0.2288 +- 0.0010 (tot.). The measurements are compared to the results of previous measurements at the Z boson resonance. The deviation with respect to the combined result provided by the LEP and SLC experiments is up to 2.7 standard deviations.
Resumo:
Die elektrische Ladung des Neutrons ist eng mit der Frage nach der Existenz der Ladungsquantisierung verknüpft: Sollte das Neutron eine Ladung tragen, kann die Ladung nicht in Einheiten der Elementarladung e quantisiert sein.rnrnIm Rahmen der Elektrodynamik und des minimalen Standardmodells ist die Quantisierung der Ladung nicht enthalten. Eine mögliche Neutronenladung würde ihnen also nicht widersprechen. Allerdings geht sie aus den Weiterentwicklungen dieser Modelle hervor. Die sogenannten Grand Unified Theories sagen die Möglichkeit des Protonenzerfalls vorher. Dieser ist nur möglich, wenn die Ladung quantisiert ist.rnrnDurch die Messung einer elektrischen Ladung des Neutrons können die verschiedenen Theorien überprüft werden.rnrnIm Rahmen dieser Arbeit wurde eine Apparatur entwickelt, mit der die elektrische Ladung des Neutrons gemessen werden kann. Als Grundlage diente das Prinzip einer Messung von 1988. Mit einem flüssigen Neutronenspiegel aus Fomblin ist es zum ersten mal überhaupt gelungen, einen flüssigen Spiegel für Neutronen einzusetzen. Durch diese und andere Verbesserungen konnte die Sensitivität der Apparatur um einen Faktor 5 im Vergleich zum Experimentrnvon 1988 verbessert werden. Eine mögliche Ladung des Neutrons kann mit δq_n = 2,15·10^(−20)·e/√day gemessen werden. rnrnDie Messung der elektrischen Ladung soll im Winter 2014 durchgeführt werden. Bis dahin soll die Präzision aufrnδq_n = 1,4·10^(−21)·e/√day erhöht werden.
Resumo:
Measurement of bladder wall thickness (BWT) using transvaginal ultrasound has previously been shown to discriminate between women with confirmed detrusor overactivity and those with urodynamic stress incontinence. Aim of the current study was to determine if vaginally measured BWT correlates with urodynamic diagnoses in a female population.
Resumo:
Noninvasive blood flow measurements based on Doppler ultrasound studies are the main clinical tool for studying the cardiovascular status in fetuses at risk for circulatory compromise. Usually, qualitative analysis of peripheral arteries and, in particular clinical situations such as severe growth restriction or volume overload, also of venous vessels close to the heart or of flow patterns in the heart are being used to gauge the level of compensation in a fetus. Quantitative assessment of the driving force of the fetal circulation, the cardiac output, however, remains an elusive goal in fetal medicine. This article reviews the methods for direct and indirect assessment of cardiac function and explains new clinical applications. Part 1 of this review describes the concept of cardiac function and cardiac output and the techniques that have been used to quantify output. Part 2 summarizes the use of arterial and venous Doppler studies in the fetus and gives a detailed description of indirect measures of cardiac function (like indices derived from the duration of segments of the cardiac cycle) with current examples of their application.
Resumo:
There are two main types of bone in the human body, trabecular and cortical bone. Cortical bone is primarily found on the outer surface of most bones in the body while trabecular bone is found in vertebrae and at the end of long bones (Ross 2007). Osteoporosis is a condition that compromises the structural integrity of trabecular bone, greatly reducing the ability of the bone to absorb energy from falls. The current method for diagnosing osteoporosis and predicting fracture risk is measurement of bone mineral density. Limitations of this method include dependence on the bone density measurement device and dependence on type of test and measurement location (Rubin 2005). Each year there are approximately 250,000 hip fractures in the United States due to osteoporosis (Kleerekoper 2006). Currently, the most common method for repairing a hip fracture is a hip fixation surgery. During surgery, a temporary guide wire is inserted to guide the permanent screw into place and then removed. It is believed that directly measuring this screw pullout force may result in a better assessment of bone quality than current indirect measurement techniques (T. Bowen 2008-2010, pers. comm.). The objective of this project is to design a device that can measure the force required to extract this guide wire. It is believed that this would give the surgeon a direct, quantitative measurement of bone quality at the site of the fixation. A first generation device was designed by a Bucknell Biomedical Engineering Senior Design team during the 2008- 2009 Academic Year. The first step of this project was to examine the device, conduct a thorough design analysis, and brainstorm new concepts. The concept selected uses a translational screw to extract the guide wire. The device was fabricated and underwent validation testing to ensure that the device was functional and met the required engineering specifications. Two tests were conducted, one to test the functionality of the device by testing if the device gave repeatable results, and the other to test the sensitivity of the device to misalignment. Guide wires were extracted from 3 materials, low density polyethylene, ultra high molecular weight polyethylene, and polypropylene and the force of extraction was measured. During testing, it was discovered that the spring in the device did not have a high enough spring constant to reach the high forces necessary for extracting the wires without excessive deflection of the spring. The test procedure was modified slightly so the wires were not fully threaded into the material. The testing results indicate that there is significant variation in the screw pullout force, up to 30% of the average value. This significant variation was attributed to problems in the testing and data collection, and a revised set of tests was proposed to better evaluate the performance of the device. The fabricated device is a fully-functioning prototype and further refinements and testing of the device may lead to a 3rd generation version capable of measuring the screw pullout force during hip fixation surgery.
Resumo:
This project had a threefold aim and sought to provide answers to several different questions. Kossowska first focused on the relationship between Openness to Experience and ideological variables such as authoritarianism and conservatism. The main questions here were (1) whether there are differences between the Polish and Belgian samples studied with respect to the relationship between political ideology and Openness to Experience, and (2) whether this relationship applies to all facets of Openness to Experience. The study showed significant negative correlations between Openness and right-wing ideology in both adult samples, and that Fantasy and Actions were the most robust correlates of political ideology. A second problem examined concerned the relationship between ideology and cognitive functioning. The important questions here were about the conceptualisation and measurement of cognitive variables such as rigidity, intolerance of ambiguity, or the need for closure, which determine individuals' attitudes to politics. The results confirmed the significance of the need for closure construct in both samples for understanding the process of formulating and holding political beliefs. The last aspect of the study was the differences in political beliefs between the Polish and Belgian samples in relation to the social, political and economic situation in the two countries. The most important question here was the changes in the political mentality of Poles during the period of system transition. Kossowska expected to find differences between Poles and Belgians with respect to the level of conservatism and authoritarianism, but in fact both samples showed comparable levels of right-wing political beliefs.
Resumo:
Vitamin C (L-ascorbic acid) is an essential micronutrient that serves as an antioxidant and as a cofactor in many enzymatic reactions. Intestinal absorption and renal reabsorption of the vitamin is mediated by the epithelial apical L-ascorbic acid cotransporter SVCT1 (SLC23A1). We explored the molecular mechanisms of SVCT1-mediated L-ascorbic acid transport using radiotracer and voltage-clamp techniques in RNA-injected Xenopus oocytes. L-ascorbic acid transport was saturable (K(0.5) approximately 70 microM), temperature dependent (Q(10) approximately 5), and energized by the Na(+) electrochemical potential gradient. We obtained a Na(+)-L-ascorbic acid coupling ratio of 2:1 from simultaneous measurement of currents and fluxes. L-ascorbic acid and Na(+) saturation kinetics as a function of cosubstrate concentrations revealed a simultaneous transport mechanism in which binding is ordered Na(+), L-ascorbic acid, Na(+). In the absence of L-ascorbic acid, SVCT1 mediated pre-steady-state currents that decayed with time constants 3-15 ms. Transients were described by single Boltzmann distributions. At 100 mM Na(+), maximal charge translocation (Q(max)) was approximately 25 nC, around a midpoint (V(0.5)) at -9 mV, and with apparent valence approximately -1. Q(max) was conserved upon progressive removal of Na(+), whereas V(0.5) shifted to more hyperpolarized potentials. Model simulation predicted that the pre-steady-state current predominantly results from an ion-well effect on binding of the first Na(+) partway within the membrane electric field. We present a transport model for SVCT1 that will provide a framework for investigating the impact of specific mutations and polymorphisms in SLC23A1 and help us better understand the contribution of SVCT1 to vitamin C metabolism in health and disease.
Resumo:
Energy crisis and worldwide environmental problem make hydrogen a prospective energy carrier. However, storage and transportation of hydrogen in large quantities at small volume is currently not practical. Lots of materials and devices have been developed for storage hydrogen, but to today none is able to meet the DOE targets. Activated carbon has been found to be a good hydrogen adsorbent due to its high surface area. However, the weak van der Waals force between hydrogen and the adsorbent has limited the adsorption capacity. Previous studies have found that enhanced adsorption can be obtained with applied electric field. Stronger interaction between the polarized hydrogen and the charged sorbents under high voltage is considered as the reason. This study was initiated to investigate if the adsorption can be further enhanced when the activated carbon particles are separated with a dielectric coating. Dielectric TiO2 nanoparticles were first utilized. Hydrogen adsorption measurements on the TiO2-coated carbon materials, with or without an external electric field, were made. The results showed that the adsorption capacity enhancement increased with the increasing amount of TiO2 nanoparticles with an applied electric field. Since the hydrogen adsorption capacity on TiO2 particles is very low and there is no hydrogen adsorption enhancement on TiO2 particles alone when electric field is applied, the effect of dielectric coating is demonstrated. Another set of experiments investigated the behavior of hydrogen adsorption over TiO2-coated activated carbon under various electric potentials. The results revealed that the hydrogen adsorption first increased and then decreased with the increase of electric field. The improved storage was due to a stronger interaction between charged carbon surface and polarized hydrogen molecule caused by field induced polarization of TiO2 coating. When the electric field was sufficient to cause considerable ionization of hydrogen, the decrease of hydrogen adsorption occurred. The current leak detected at 3000 V was a sign of ionization of hydrogen. Experiments were also carried out to examine the hydrogen adsorption performances over activated carbon separated by other dielectric materials, MgO, ZnO and BaTiO3, respectively. For the samples partitioned with MgO and ZnO, the measurements with and without an electric field indicated negligible differences. Electric field enhanced adsorption has been observed on the activated carbon separated with BaTiO3, a material with unusually high dielectric constant. Corresponding computational calculations using Density Functional Theory have been performed on hydrogen interaction with charged TiO2 molecule as well as TiO2 molecule, coronene and TiO2-doped coronene in the presence of an electric field. The simulated results were consistent with the observations from experiments, further confirming the proposed hypotheses.
Resumo:
Rising fuel prices and environmental concerns are threatening the stability of current electrical grid systems. These factors are pushing the automobile industry towards more effcient, hybrid vehicles. Current trends show petroleum is being edged out in favor of electricity as the main vehicular motive force. The proposed methods create an optimized charging control schedule for all participating Plug-in Hybrid Electric Vehicles in a distribution grid. The optimization will minimize daily operating costs, reduce system losses, and improve power quality. This requires participation from Vehicle-to-Grid capable vehicles, load forecasting, and Locational Marginal Pricing market predictions. Vehicles equipped with bidirectional chargers further improve the optimization results by lowering peak demand and improving power quality.