995 resultados para Downstream Protection Values
Resumo:
The prevention of hepatitis B by vaccination is one of the most efficient tools to avoid the transmission of the virus. This study evaluated the immunogenicity of the national vaccine Butang® in children born in Campo Mourão City, state of Paraná, Brazil, aged 7 to 12 months, by determining the anti-HBsAg antibodies levels after completion of the National Immunization Program Protocol for hepatitis B. All 70 children evaluated by the MEIA method (immune-enzymatic micro particles) showed seroconversion to the Butang® vaccine. Nine children (12.9%) presented a low response, with anti-HBs titers between 11 and 100 mUI/ml; 39 children (55.7%) showed a good response to the vaccine, with titers between 101 and 1000 mUI/ml; and 22 children (31.4%) showed antibodies titers higher than 1000 mUI/ml. The mean titer of the anti-HBs antibody titers was 1408.1 ± 2870.26 mUI/ml (15.7 to 19560.0 mUI/ml). The levels of antibodies produced by the prematurely-born children were not statistically different from those found in the newborns. Fifty-five children were also evaluated through the ELFA method (ELISA with a final detection in fluorescence), which presented similar results. The results obtained in our study corroborated the effectiveness of the national vaccine Butang® in newborn children of Campo Mourão City, Paraná, even if they were premature.
Resumo:
The need to develop a vaccine against schistosomiasis led several researches and our group to investigate proteins from Schistosoma mansoni as vaccine candidates. Sm22.6 is a protein from S. mansoni that shows high identity with Sj22.6 and Sh22.6 (79 and 91%, respectively). These proteins are associated with high levels of IgE and protection to reinfection. Previously, we have shown that Sm22.6 induced a partial protection of 34.5% when used together with Freund's adjuvant and produced a Th0 type of immune response with interferon-g and interleukin-4. In this work, mice were immunized with Sm22.6 alone or with aluminum hydroxide adjuvant and high levels of IgG, IgG1, and IgG2a were measured. Unfortunately, no protection was detected. Since IL-10 is a modulating cytokine in schistosomiasis, we also observed a high level of this molecule in splenocytes of vaccinated mice. In conclusion, we did not observe the adjuvant effect of aluminum hydroxide associated with rSm22.6 in protective immunity.
Resumo:
Public health services in Ireland, North and South, are committed to addressing inequalities in health on the island of Ireland. This report, prepared by Dr Lorraine Doherty, Assistant Director of Public Health (Health Protection), Public Health Agency NI for the Institute of Public Health in Ireland (IPH), specifically highlights health inequalities in relation to infectious diseases and other areas of health protection such as chemical hazards and environmental disruption. Infectious diseases disproportionately affect the most vulnerable in society. These vulnerable groups bear the highest burden of disease in relation to infectious diseases. The report also highlights the impact of climate change on health protection and the impacts for water, food and vector borne diseases. The aim of this report is to enable a programme of work to begin to document health protection inequalities and develop action plans for addressing them on an all island basis.
Resumo:
Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.
Resumo:
BACKGROUND: The accumulation of mutations after long-lasting exposure to a failing combination antiretroviral therapy (cART) is problematic and severely reduces the options for further successful treatments. METHODS: We studied patients from the Swiss HIV Cohort Study who failed cART with nucleoside reverse transcriptase inhibitors (NRTIs) and either a ritonavir-boosted PI (PI/r) or a non-nucleoside reverse transcriptase inhibitor (NNRTI). The loss of genotypic activity <3, 3-6, >6 months after virological failure was analyzed with Stanford algorithm. Risk factors associated with early emergence of drug resistance mutations (<6 months after failure) were identified with multivariable logistic regression. RESULTS: Ninety-nine genotypic resistance tests from PI/r-treated and 129 from NNRTI-treated patients were analyzed. The risk of losing the activity of ≥1 NRTIs was lower among PI/r- compared to NNRTI-treated individuals <3, 3-6, and >6 months after failure: 8.8% vs. 38.2% (p = 0.009), 7.1% vs. 46.9% (p<0.001) and 18.9% vs. 60.9% (p<0.001). The percentages of patients who have lost PI/r activity were 2.9%, 3.6% and 5.4% <3, 3-6, >6 months after failure compared to 41.2%, 49.0% and 63.0% of those who have lost NNRTI activity (all p<0.001). The risk to accumulate an early NRTI mutation was strongly associated with NNRTI-containing cART (adjusted odds ratio: 13.3 (95% CI: 4.1-42.8), p<0.001). CONCLUSIONS: The loss of activity of PIs and NRTIs was low among patients treated with PI/r, even after long-lasting exposure to a failing cART. Thus, more options remain for second-line therapy. This finding is potentially of high relevance, in particular for settings with poor or lacking virological monitoring.
Resumo:
Despite abundant research on work meaningfulness, the link between work meaningfulness and general ethical attitude at work has not been discussed so far. In this article, we propose a theoretical framework to explain how work meaningfulness contributes to enhanced ethical behavior. We argue that by providing a way for individuals to relate work to one's personal core values and identity, work meaningfulness leads to affective commitment - the involvement of one's cognitive, emotional, and physical resources. This, in turn, leads to engagement and so facilitates the integration of one's personal values in the daily work routines, and so reduces the risk of unethical behavior. On the contrary, anomie, that is, the absence of meaning and consequently of personal involvement, will lead to lower rational commitment rather than affective commitment, and consequently to disengagement and a-morality. We conclude with implications for the management of ethical attitudes.
Resumo:
Addressing the risks of nanoparticles requires knowledge about release into the environment and occupational exposure. However, such information currently is not systematically collected; therefore, this risk assessment lacks quantitative data. The goal was to evaluate the current level of nanoparticle usage in Swiss industry as well as health, safety, and environmental measures, and the number of potentially exposed workers. A representative, stratified mail survey was conducted among 1626 clients of the Swiss National Accident Insurance Fund (SUVA), which insures 80,000 manufacturing firms, representing 84% of all Swiss manufacturing companies (947 companies answered the survey for a 58.3% response rate). The extrapolation to all Swiss manufacturing companies results in 1309 workers (95% confidence interval [CI]: 1073 to 1545) potentially exposed to nanoparticles in 586 companies (95% CI: 145 to 1027). This corresponds to 0.08% of workers (95% CI: 0.06% to 0.09%) and to 0.6% of companies (95% CI: 0.2% to 1.1%). The industrial chemistry sector showed the highest percentage of companies using nanoparticles (21.2%). Other important sectors also reported nanoparticles. Personal protection equipment was the predominant protection strategy. Only a few applied specific environmental protection measures. This is the first nationwide representative study on nanoparticle use in the manufacturing sector. The information gained can be used for quantitative risk assessment. It can also help policymakers design strategies to support companies developing a safer use of nanomaterial. Notingthe current low use of nanoparticles, there is still time to proactively introduce protective methods. If the predicted "nano-revolution" comes true, now is the time to take action. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of occupational and Environmental Hygiene for the following free supplemental resource: a pdf file containing a detailed description of the approach to statistical analyses, English translation of the questionnaire, additional information for Figure 1, and additional information for the SUVA-code.] [Authors]