890 resultados para Distributed replication system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present article is to assess and compare the performance of electricity generation systems integrated with downdraft biomass gasifiers for distributed power generation. A model for estimating the electric power generation of internal combustion engines and gas turbines powered by syngas was developed. First, the model determines the syngas composition and the lower heating value; and second, these data are used to evaluate power generation in Otto, Diesel, and Brayton cycles. Four synthesis gas compositions were tested for gasification with: air; pure oxygen; 60% oxygen with 40% steam; and 60% air with 40% steam. The results show a maximum power ratio of 0.567 kWh/Nm(3) for the gas turbine system, 0.647 kWh/Nm(3) for the compression ignition engine, and 0.775 kWh/Nm(3) for the spark-ignition engine while running on synthesis gas which was produced using pure oxygen as gasification agent. When these three systems run on synthesis gas produced using atmospheric air as gasification agent, the maximum power ratios were 0.274 kWh/Nm(3) for the gas turbine system, 0.302 kWh/Nm(3) for CIE, and 0.282 kWh/Nm(3) for SIE. The relationship between power output and synthesis gas flow variations is presented as is the dependence of efficiency on compression ratios. Since the maximum attainable power ratio of CIE is higher than that of SIE for gasification with air, more research should be performed on utilization of synthesis gas in CIE. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Usually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is concerned with the controllability and stabilizability problem for control systems described by a time-varyinglinear abstract differential equation with distributed delay in the state variables. An approximate controllability propertyis established, and for periodic systems, the stabilization problem is studied. Assuming that the semigroup of operatorsassociated with the uncontrolled and non delayed equation is compact, and using the characterization of the asymptoticstability in terms of the spectrum of the monodromy operator of the uncontrolled system, it is shown that the approximatecontrollability property is a sufficient condition for the existence of a periodic feedback control law that stabilizes thesystem. The result is extended to include some systems which are asymptotically periodic. Copyright © 2014 John Wiley &Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The transmission system is responsible for connecting the power generators to consumers safely and reliably, its constant expansion is necessary to transport increasing amounts of electricity. In order to help the power systems engineers, an optimization tool for optimize the expansion of the transmission system was developed using the modeling method of the linearized load flow and genetic. This tool was designed to simulate the impact of different scenarios on the cost of transmission expansion. The proposed tool was used to simulate the effects of the presence of distributed generation in the expansion of a fictitious transmission system, where it was found a clear downward trend in investment required for the expansion of the transmission system taking account of increasing levels of distributed generation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a smart grid environment, attention should be paid not only to the power supplied to satisfy loads and system losses but also to the services necessary to provide security and stability to the system: the so-called ancillary services. As they are well known the benefits that distributed generation can bring to electrical systems and to the environment, in this work the possibility that active power reserve for frequency control could be provided by distributed generators (DGs) in an efficient and economical way is explored. The proposed methodology was tested using the IEEE 34-bus distribution test system. The results show improvements in the capacity of the system for this ancillary service and decrease in system losses and payments of the distribution system operator to the DGs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eight reproductive rams with no prior reproductive disease were distributed into three groups of infection with T. gondii: GI, 3 rams, 2.0 x 10(5) P strain oocysts; GII, 3 rams, 1.0 x 10(6) RH strain tachyzoites; GIII, 2 control rams. Clinical parameters were measured and serological evaluations (IIF) were performed. Presence of the parasite in the semen was investigated by PCR and bioassay techniques. The rams presented clinical alterations (hyperthermia and apathy) related to toxoplasmosis in both groups infected with Toxoplasma gondii. All the inoculated rams responded to antigenic stimulus, producing antibodies against T. gondii from postinoculation day 5 onwards. In ovine groups I and II, the greatest titers observed were 1 : 4096 and 1 : 8192, respectively. In semen samples collected from these two groups, the presence of T. gondii was detected by bioassay and PCR. This coccidian was isolated (bioassay and PCR) in tissue pools (testicles, epididymis, seminal vesicle, and prostrate) from two rams infected presenting oocysts and in one presenting tachyzoites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Members of the subfamily Alphaherpesvirinae use the epithelium of the upper respiratory and/or genital tract as preferential sites for primary replication. However, bovine herpesvirus 5 (BoHV5) is neurotropic and neuroinvasive and responsible for meningoencephalitis in cattle and in animal models. A related virus, BoHV1 has also been occasionally implicated in natural cases of neurological infection and disease in cattle. The aim of the present study was to assess the in vitro effects of BoHV1 and BoHV5 replication in neuron-like cells. Overall, cytopathic effects, consisting of floating rounded cells, giant cells and monolayer lysis, induced by both viruses at 48 h postinfection (p.i.) resulted in a loss of cell viability and high virus titres (r = 0.978). The BoHV1 Cooper strain produced the lowest titres in neuron-like cells, although viral DNA was detected in infected cells during all experiments. Virus replication in infected cells was demonstrated by immunocytochemistry, flow cytometry and qPCR assays. BoHV antigens were better visualized at 48 h p.i. and flow cytometry analysis showed that SV56/90 and Los Angeles antigens were present at higher levels. In spite of the fact that BoHV titres dropped at 48 h p.i, viral DNA remained detectable until 120 h p.i. Sensitive TUNEL (terminal deoxynucleotidyltransferase-mediated dUTP-biotin nick end labeling) and annexin V assays were used to identify apoptosis. BoHV5 induced death in approximately 50 % of cells within 24 h p.i., similar to what has been observed for BoHV1 Los Angeles. Infection with the BoHV1 Cooper strain resulted in 26.37 % of cells being in the early stages of apoptosis; 63.69 % of infected cells were considered viable. Modulation of mitochondrial function, as measured by mitochondrial membrane depolarization, was synchronous with the virus replication cycle, cell viability and virus titres at 48 h p.i. Our results indicate that apoptosis plays an important role in preventing neuronal death and provides a bovine-derived in vitro system to study herpesvirus-neuron interactions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wireless LAN technology, despite the numerous advantages it has over competing technologies, has not seen widespread deployment. A primary reason for markets not adopting this technology is its failure to provide adequate security. Data that is sent over wireless links can be compromised with utmost ease. In this project, we propose a distributed agent based intrusion detection and response system for wireless LANs that can detect unauthorized wireless elements like access points, wireless clients that are in promiscuous mode etc. The system reacts to intrusions by either notifying the concerned personnel, in case of rogue access points and promiscuous nodes, or by blocking unauthorized users from accessing the network resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Access control is a fundamental concern in any system that manages resources, e.g., operating systems, file systems, databases and communications systems. The problem we address is how to specify, enforce, and implement access control in distributed environments. This problem occurs in many applications such as management of distributed project resources, e-newspaper and payTV subscription services. Starting from an access relation between users and resources, we derive a user hierarchy, a resource hierarchy, and a unified hierarchy. The unified hierarchy is then used to specify the access relation in a way that is compact and that allows efficient queries. It is also used in cryptographic schemes that enforce the access relation. We introduce three specific cryptography based hierarchical schemes, which can effectively enforce and implement access control and are designed for distributed environments because they do not need the presence of a central authority (except perhaps for set- UP).