984 resultados para Digital mammographic images
Resumo:
Modulation of subjective time was examined using static images eliciting perceptions of different intensities of body movement. Undergraduate students were exposed to photographs of dancer sculptures in different dance positions for 36 sec. and asked to estimate the exposure duration. Lower movement intensities were related to shorter estimated durations. Mean durations for images of unmoving dancers were underestimated and for dancers taking a ballet step were overestimated. Temporal estimations were also related to the order of presentation of the stimuli, which suggested that subjective time estimations were influenced by the experimental context. Subjective time is related not only to the visual perception of moving images, but also of elicited perceptions of movement in static images, suggesting an embodiment effect on subjective time estimation.
Resumo:
Background: A survey of pathology reporting of breast cancer in Western Australia in 1989 highlighted the need for improvement. The current study documents (1) changes in pathology reporting from 1989 to 1999 and (2) changes in patterns of histopathological prognostic indicators for breast cancer following introduction of mammographic screening in 1989. Methods: Data concerning all breast cancer cases reported in Western Australia in 1989, 1994 and 1999 were retrieved using the State Cancer Registry, Hospital Morbidity data system, and pathology laboratory records. Results: Pathology reports improved in quality during the decade surveyed. For invasive carcinoma, tumour size was not recorded in 1.2% of pathology reports in 1999 compared with 16.1% in 1989 (rho<0.001). Corresponding figures for other prognostic factors were: tumour grade 3.3% and 51.6% (rho<0.001), tumour type 0.2% and 4.1% (rho<0.001), vascular invasion 3.7% and 70.9% (rho<0.001), and lymph node status 1.9% and 4.5% (rho=0.023). In 1999, 5.9% of reports were not in a synoptic/checklist format, whereas all reports were descriptive in 1989 (rho<0.001). For the population as a whole, the proportion of invasive carcinomas <1 cm was 20.9% in 1999 compared with 14.5% in 1989 (rho<0.001); for tumours <2 cm the corresponding figures were 65.4% and 59.7% (rho=0.013). In 1999, 30.5% of tumours were histologically well-differentiated compared with 10.6% in 1989 (rho<0.001), and 61.7% were lymph node negative in 1999 compared with 57.1% in 1989 (rho=0.006). Pure ductal carcinoma in situ (DCIS) constituted 10.9% and 7.9% of total cases of breast carcinoma in 1999 and 1989, respectively (rho=0.01). Conclusions: Quality of pathology reporting improved markedly over the period, in parallel with adoption of stanclardised synoptic pathology reports. By 1999, recording of important prognostic information was almost complete. Frequency of favourable prognostic factors generally increased over time, reflecting expected effects of mammographic screening.
Resumo:
An 18-year-old boy with refractory epilepsy and aggressiveness associated to a hypothalamic hamartoma was submitted to a stereotactically guided lesion by thermocoagulation. The target was based on magnetic resonance (MR) images merged with computed tomography scan images taken on the day of surgery while patient was on a stereotactic frame. In order to reveal structures not discernible in MR images, the Schaltenbrand digital brain atlas was merged onto the patient`s images. Target and trajectory of the depth electrode were chosen based on three-dimensional imaging reconstructions. A surgical plan was devised to disconnect the hypothalamic hamartoma from the hypothalamus, medial forebrain bundle, fasciculus princeps, and dorsal longitudinal fasciculus. Our target was placed at the inferior portion of the posterolateral component of the hamartoma, bordering the normal hypothalamus. The patient evolved with marked lessening of aggressiveness. Seizure frequency was reduced from several seizures per day to less than one tonic-clonic seizure during sleep per month and only two episodes suggestive of partial complex seizures during daytime. These results have remained consistent over a 24-month postoperative follow-up. Functional neuroanatomy of hypothalamic connections involved in seizure propagation and aggressive behavior was reviewed.
Resumo:
OBJECTIVE: To describe the microsurgical anatomy, branches, and anatomic relationships of the posterior cerebral artery (PCA) represented in three-dimensional images. METHODS: Seventy hemispheres of 35 brain specimens were studied. They were previously injected with red silicone and fixed in 10% formalin for at least 40 days. Four of the studied specimens were frozen at -10 degrees to -15 degrees C for 14 days, and additional dissection was done with the Klingler`s fiber dissection technique at x6 to x40 magnification. Each segment of the artery was measured and photographed to obtain three-dimensional stereoscopic images. RESULTS: The PCA origin was in the interpeduncular cistern at the pontomesencephalic junction level in 23 specimens (65.7%). The PCA was divided into four segments: P1 extends from the PCA origin to its junction with the posterior communicating artery with an average length of 7.7 mm; P2 was divided into an anterior and posterior segment. The P2A segment begins at the posterior communicating artery and ends at the most lateral aspect of the cerebral peduncle, with an average length of 23.6 mm, and the P2P segment extends from the most lateral aspect of the cerebral peduncle to the posterior edge of the lateral surface of the midbrain, with an average length of 16.4 mm; P3 extends from the posterior edge of the lateral surface of the midbrain and ends at the origin of the parieto-occipital sulcus along the calcarine fissure, with an average length of 19.8 mm; and the P4 segment corresponds to the parts of the PCA that run along or inside both the parieto-occipital sulcus and the distal part of the calcarine fissure. CONCLUSIONS: To standardize the neurosurgical practice and knowledge, surgical anatomic classifications should be used uniformly and further modified according to the neurosurgical experience gathered. The PCA classification proposed intends to correlate its anatomic segments with their required microneurosurgical approaches.
Resumo:
The use of X-ray imaging to assess variability in ceramic fabrication is common in archaeological studies aimed at examining ancient pottery technologies. In this paper, a method based on the measurement of individual pores orientation is presented. This method is successfully applied to ceramic specimens of known origin whose structure signified different deformation histories.
Resumo:
The objective of this study is to determine if digital vasculitis (DV), a clinical manifestation with a high systemic lupus erythematosus disease activity index (SLEDAI) score, is associated with lupus severity. DV and other clinical manifestations defined according to the SLEDAI were evaluated in 168 consecutive patients with systemic lupus erythematosus (SLE). Two groups were defined according to presence (DV+, n = 27) or absence of DV (DV-, n = 141) at the time of evaluation. The exclusion criterion was the presence of antiphospholipid syndrome (Sapporo`s criteria). The two groups were comparable with regard to age (P = 0.09), gender (P = 1.00), white race (P = 0.81), and disease duration (P = 0.78). Compared to the DV-group, the DV+ group had a significantly higher frequency of mucocutaneous manifestations (66.7 vs. 39.0%, P = 0.01), haematological abnormalities (22.2 vs. 6.4%, P = 0.02) and constitutional symptoms (11.1 vs. 0.7%, P = 0.01). Renal and neurological involvements were similar in both groups ( P = 0.57 and P = 1.00, respectively). The evaluation of each SLEDAI parameter confirmed that the DV+ group had higher frequencies of mild manifestations, such as new rash (P = 0.02), alopecia (P = 0.02), oral ulcers (P = 0.045), fever (P = 0.01) and leucopenia (P = 0.005). In contrast, both groups had similarly increased anti-dsDNA (P = 0.78) and decreased complement levels (P = 0.29). In conclusion, DV in patients with SLE identifies a subgroup of a mild disease. The high `weighted` index attributed to this alteration in the SLEDAI score should therefore be revised. Lupus (2009) 18, 990-993.
Resumo:
Computer modelling has shown that electrical characteristics of individual pixels may be extracted from within multiple-frequency electrical impedance tomography (MFEIT) images formed using a reference data set obtained from a purely resistive, homogeneous medium. In some applications it is desirable to extract the electrical characteristics of individual pixels from images where a purely resistive, homogeneous reference data set is not available. One such application of the technique of MFEIT is to allow the acquisition of in vivo images using reference data sets obtained from a non-homogeneous medium with a reactive component. However, the reactive component of the reference data set introduces difficulties with the extraction of the true electrical characteristics from the image pixels. This study was a preliminary investigation of a technique to extract electrical parameters from multifrequency images when the reference data set has a reactive component. Unlike the situation in which a homogenous, resistive data set is available, it is not possible to obtain the impedance and phase information directly from the image pixel values of the MFEIT images data set, as the phase of the reactive reference is not known. The method reported here to extract the electrical characteristics (the Cole-Cole plot) initially assumes that this phase angle is zero. With this assumption, an impedance spectrum can be directly extracted from the image set. To obtain the true Cole-Cole plot a correction must be applied to account for the inherent rotation of the extracted impedance spectrum about the origin, which is a result of the assumption. This work shows that the angle of rotation associated with the reactive component of the reference data set may be determined using a priori knowledge of the distribution of frequencies of the Cole-Cole plot. Using this angle of rotation, the true Cole-Cole plot can be obtained from the impedance spectrum extracted from the MFEIT image data set. The method was investigated using simulated data, both with and without noise, and also for image data obtained in vitro. The in vitro studies involved 32 logarithmically spaced frequencies from 4 kHz up to 1 MHz and demonstrated that differences between the true characteristics and those of the impedance spectrum were reduced significantly after application of the correction technique. The differences between the extracted parameters and the true values prior to correction were in the range from 16% to 70%. Following application of the correction technique the differences were reduced to less than 5%. The parameters obtained from the Cole-Cole plot may be useful as a characterization of the nature and health of the imaged tissues.
Resumo:
The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture`s warranty expires. Aim: to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers. Study design: experimental. Materials and Methods: to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. Results: The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. Conclusion: It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers` supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).
Resumo:
Objectives. To compare pelvic floor muscle (PFM) strength between women undergoing vaginal delivery, cesarean section, and nulliparae, investigating the factors associated with PFM strength, and observing the correlation between vaginal digital palpation and use of a perineometer. Methods. A cross-sectional study was conducted, including 31 women following vaginal delivery, 30 women following cesarean section, and 30 nulliparous women. PFM strength was measured by vaginal digital palpation and use of a perineometer. Multiple linear regression analysis with adjustment for covariables was used to compare the mean PFM strength and identify its associated factors. Results. The mean PFM strength of women undergoing vaginal delivery and cesarean section was 25.6 +/- 14.5 cmH(2)O and 39.6 +/- 22.0 cmH(2)O (p < 0.01, adjusted for covariables), respectively. A correlation was observed between measurements of PFM strength obtained by vaginal digital palpation and use of a perineometer (tau = 0.82; p < 0.01). The non-white race/ethnicity was negatively associated with PFM strength (coefficient: -10.2424; p = 0.02). Conclusions. A lower PFM strength was observed in women with a history of vaginal delivery compared to those undergoing cesarean section. Non-white race/ethnicity negatively affected PFM strength. Our data suggest that vaginal digital palpation may be used in clinical practice because of its expressive correlation with use of a perineometer.