857 resultados para Continuous improvements
Resumo:
Our objective was to determine if automated peritoneal dialysis (APD) leads to changes in nutritional parameters of patients treated by continuous ambulatory peritoneal dialysis (CAPD). Twenty-six patients (15 males; 50.5 ± 14.3 years) were evaluated during CAPD while training for APD and after 3 and 6 months of APD. Body fat was assessed by the sum of skinfold thickness and the other body compartments were assessed by bioelectrical impedance. During the 6-month follow-up, 12 patients gained more than 1 kg (GW group), 8 patients lost more than 1 kg (LW group), and 6 patients maintained body weight (MW group). Except for length on dialysis that was longer for the LW group compared with the GW group, no other differences were found between the groups at baseline. After 6 months on APD, the LW group had a reduction in body fat (24.5 ± 7.7 vs 22.1 ± 7.3 kg; P = 0.01), body cell mass (22.6 ± 6.2 vs 21.6 ± 5.8 kg, P = 0.02) and phase angle (5.4 ± 0.9 vs 5.1 ± 0.8 degrees, P = 0.004). In the GW group, body fat (25 ± 7.6 vs 27.2 ± 7.6 kg, P = 0.001) and body cell mass (20.1 ± 3.9 vs 20.8 ± 4.0 kg, P = 0.05) were increased. In the present study, different patterns of change in body composition were found. The length of previous dialysis treatment seems to be the most important factor in determining these nutritional modifications.
Resumo:
This study evaluated whether the use of continuous positive airway pressure (CPAP) in the delivery room alters the need for mechanical ventilation and surfactant during the first 5 days of life and modifies the incidence of respiratory morbidity and mortality during the hospital stay. The study was a multicenter randomized clinical trial conducted in five public university hospitals in Brazil, from June 2008 to December 2009. Participants were 197 infants with birth weight of 1000-1500 g and without major birth defects. They were treated according to the guidelines of the American Academy of Pediatrics (APP). Infants not intubated or extubated less than 15 min after birth were randomized for two treatments, routine or CPAP, and were followed until hospital discharge. The routine (n=99) and CPAP (n=98) infants studied presented no statistically significant differences regarding birth characteristics, complications during the prenatal period, the need for mechanical ventilation during the first 5 days of life (19.2 vs 23.4%, P=0.50), use of surfactant (18.2 vs 17.3% P=0.92), or respiratory morbidity and mortality until discharge. The CPAP group required a greater number of doses of surfactant (1.5 vs 1.0, P=0.02). When CPAP was applied to the routine group, it was installed within a median time of 30 min. We found that CPAP applied less than 15 min after birth was not able to reduce the need for ventilator support and was associated with a higher number of doses of surfactant when compared to CPAP applied as clinically indicated within a median time of 30 min.
Resumo:
In this work the separation of multicomponent mixtures in counter-current columns with supercritical carbon dioxide has been investigated using a process design methodology. First the separation task must be defined, then phase equilibria experiments are carried out, and the data obtained are correlated with thermodynamic models or empirical functions. Mutual solubilities, Ki-values, and separation factors aij are determined. Based on this data possible operating conditions for further extraction experiments can be determined. Separation analysis using graphical methods are performed to optimize the process parameters. Hydrodynamic experiments are carried out to determine the flow capacity diagram. Extraction experiments in laboratory scale are planned and carried out in order to determine HETP values, to validate the simulation results, and to provide new materials for additional phase equilibria experiments, needed to determine the dependence of separation factors on concetration. Numerical simulation of the separation process and auxiliary systems is carried out to optimize the number of stages, solvent-to-feed ratio, product purity, yield, and energy consumption. Scale-up and cost analysis close the process design. The separation of palmitic acid and (oleic+linoleic) acids from PFAD-Palm Fatty Acids Distillates was used as a case study.
Resumo:
Solvent extraction of calcium and magnesium impurities from a lithium-rich brine (Ca ~ 2,000 ppm, Mg ~ 50 ppm, Li ~ 30,000 ppm) was investigated using a continuous counter-current solvent extraction mixer-settler set-up. The literature review includes a general review about resources, demands and production methods of Li followed by basics of solvent extraction. Experimental section includes batch experiments for investigation of pH isotherms of three extractants; D2EHPA, Versatic 10 and LIX 984 with concentrations of 0.52, 0.53 and 0.50 M in kerosene respectively. Based on pH isotherms LIX 984 showed no affinity for solvent extraction of Mg and Ca at pH ≤ 8 while D2EHPA and Versatic 10 were effective in extraction of Ca and Mg. Based on constructed pH isotherms, loading isotherms of D2EHPA (at pH 3.5 and 3.9) and Versatic 10 (at pH 7 and 8) were further investigated. Furthermore based on McCabe-Thiele method, two extraction stages and one stripping stage (using HCl acid with concentration of 2 M for Versatic 10 and 3 M for D2EHPA) was practiced in continuous runs. Merits of Versatic 10 in comparison to D2EHPA are higher selectivity for Ca and Mg, faster phase disengagement, no detrimental change in viscosity due to shear amount of metal extraction and lower acidity in stripping. On the other hand D2EHPA has less aqueous solubility and is capable of removing Mg and Ca simultaneously even at higher Ca loading (A/O in continuous runs > 1). In general, shorter residence time (~ 2 min), lower temperature (~23 °C), lower pH values (6.5-7.0 for Versatic 10 and 3.5-3.7 for D2EHPA) and a moderately low A/O value (< 1:1) would cause removal of 100% of Ca and nearly 100% of Mg while keeping Li loss less than 4%, much lower than the conventional precipitation in which 20% of Li is lost.
Resumo:
The physical and chemical alterations in palm oil during continuous industrial par frying of breaded chicken snacks were evaluated using a pseudo first-order kinetic model. The acidity index, refractive index, concentration of polar compounds, viscosity, color, and absorbance (232 and 268 nm) of 238 samples of the frying oil collected during 26 days of production were analyzed. For all of the analyses, the results of the oil were below the limits recommended for oil disposal, indicating that the processing conditions were safe and that under these experimental conditions the oil remained suitable for frying. The linear regressions were significant for refractive index, content of polar compounds, and lightness (L*). The content of polar compounds was determined using a cooking oil tester, and it had the best fit to the proposed model and can be used as an effective index for monitoring palm oil during the continuous par frying of breaded chicken snacks. The high turnover rate of the oil was important for maintaining the oil in good running conditions.
Resumo:
This research concerns the Urban Living Idea Contest conducted by Creator Space™ of BASF SE during its 150th anniversary in 2015. The main objectives of the thesis are to provide a comprehensive analysis of the Urban Living Idea Contest (ULIC) and propose a number of improvement suggestions for future years. More than 4,000 data points were collected and analyzed to investigate the functionality of different elements of the contest. Furthermore, a set of improvement suggestions were proposed to BASF SE. Novelty of this thesis lies in the data collection and the original analysis of the contest, which identified its critical elements, as well as the areas that could be improved. The author of this research was a member of the organizing team and involved in the decision making process from the beginning until the end of the ULIC.
Resumo:
Työssä tutkittiin kirjallisuustyönä akkuteknologian nykytilaa ja markkinoita kulutuselektroniikan osalta. Työssä tehtiin myös katsaus potentiaalisiin tulevaisuuden akkuteknologioihin. Työssä havaittiin, että kulutuselektroniikassa ainoat suuresti käytetyt akkutyypit ovat nikkelimetallihybridi- (NiMH) ja litiumioniakut (Li-ion). Tärkeimpänä ominaisuutena kulutuselektroniikassa akuilla yleensä pidetään kapasiteettia, jossa Li-ion akut ovat selvästi parempia jopa kaksinkertaisen energiatiheyden takia. Li-ion akuilla voidaan saavuttaa myös moninkertainen käyttöikä lataussykleinä ja moninkertainen purkausvirta, riippuen käytetystä katodimateriaalista. NiMH akuilla etuna on lähinnä halvempi hinta ja parempi turvallisuus. Toisaalta myös pieni jännite voidaan laskea hyväksi puoleksi, koska NiMH akuilla voidaan korvata kertakäyttöisiä alkaliparistoja. Vuonna 2012 Li-ion akkuja myytiin kapasiteetissa mitattuna jopa kahdeksan kertaa enemmän kuin NiMH akkuja ja myyntimäärien ennustetaan myös kasvavan tulevaisuudessa. Liion akkujen myyntimääristä suurin osa oli kulutuselektroniikan käyttökohteisiin ja jopa kaksi kolmasosaa oli kannettavien tietokoneiden ja kännyköiden akkuja. Uusia akkuteknologioita ja Li-ion akkujen parannuksia on paljon kehitteillä, mutta suurimman potentiaalin ja myös suuret ongelmat kaupallistumiseen omaa litium-ilma akut. Lyhyemmällä aikavälillä potentiaalisia teknologioita ovat litium-rikki akut, sekä nykyisiin Li-ion akkuihin kehitteillä olevat anodimateriaalit kuten esim. pii ja alumiini/titaani, joiden ongelmiin on löydetty ratkaisuja nanoteknologiasta.
Resumo:
Internet of Things or IoT is revolutionizing the world we are living in, similarly the way Internet and the web did few decades ago. It is changing how we interact with the things surrounding us. Electronic health and remote patient monitoring are the ways of utilizing these technological improvements towards the healthcare. There are many applications of IoT in eHealth such as, it will open the gate to provide healthcare to the remote areas of the world, where healthcare through traditional hospital systems cannot be provided. To connect these new eHealth IoT systems with the existing healthcare information systems, we can use the existing interoperability standards commonly used in healthcare information systems. In this thesis we implemented an eHealth IoT system based on Health Level 7 interoperability standard for continuous data transmission. There is not much previous work done in implementing the HL7 for continuous sensor data transmission. Some of the previous work was limited to sensors which are not continuous in nature and some of it is only theatrical architecture. This thesis aims to prove that it is possible to implement an eHealth IoT system by using sensors which require continues data transmission, such as respiratory sensors, and to connect it with the existing eHealth information system semantically by using HL7 interoperability standard. This system will be beneficial in implementing eHealth IoT systems for those patients, who requires continuous healthcare personal monitoring. This includes elderly people and patients, whose health need to be monitored constantly. To implement the architecture, HL7 v2.5 is selected due to its ease of implementation and low size. We selected some open source technologies because of their open licenses and large developer community. We will also review the most efficient technology available in every layer of eHealth IoT system and will propose an efficient system.
Resumo:
Arsenic, bismuth, germanium, antimony and tin were simultaneously determined by continuous hydride generation and inductively coupled plasma-atomic emission spectrometry . I Hydrides were introduced into four different types of gas-liquid separators. Two of the gas-liquid separators were available in-house. A third was developed for this project and a fourth was based on a design used by CET AC. The best signal intensity was achieved by the type II frit-based gas-liquid separator, but the modified Cetac design gave promise for the future, due to low relative standard deviation. A method was developed for the determination of arsenic, bismuth, antimony and tin in low-alloy steels. Four standard reference materials from NIST were dissolved in 10 mL aqua regia without heat. Good agreement was obtained between experimental values and certified values for arsenic, bismuth, antimony and tin. The method was developed to provide the analyst with the opportunity to determine the analytes by using simple aqueous standards to prepare calibration lines. Within the limits of the samples analyzed, the method developed is independent of matrix.
Resumo:
Research has shown a consistent correlation between efficacy and sport performance (Moritz, et aI., 2000). This relationship has been shown to be dynamic and reciprocal over seasons (e.g., Myers, Payment, et aI., 2004), within games (e.g., Butt, et aI., 2003), and across trials (e.g., Feltz, 1982). The purpose of the present study was to examine selfefficacy and performance simultaneously within one continuous routine. Forty-seven undergraduate students performed a gymnastic sequence while using an efficacy measure. Results indicated that the efficacy-performance relationship was not reciprocal; previous performance was a significant predictor of subsequent performance (p < .01; f3s ranged from .44 to .67). Results further revealed significant differences in efficacy beliefs between groups with high and low levels of performance [F (1,571) = 7.16,p < .01]. Findings suggest that high levels of performance within a continuous physical activity task result in higher performance scores and higher efficacy beliefs.
Resumo:
The self-efficacy-performance relationship in continuous sport tasks has been shown to be significantly reciprocal yet unequal with stronger influences in the performance-to-self-efficacy pathway rather than self-efficacy-to-performance pathway (e.g., LaForge-MacKenzie & Sullivan, 2014b). Bandura (2012) suggested that sociocognitive variables may influence this relationship. Attention as a sociocognitve factor may bias the processing of performance and self-efficacy information (Bandura, 1982, 1997; Bandura & Jourden, 1991). As confidence and attention are important aspects of peak running performance (Brewer, Van Raalte, Linder, & VanRaalte, 1991), the primary purpose of the present study was to examine the self-efficacy-performance relationship under three conditions of attentional focus. The secondary purpose was to examine self-efficacy and performance as separate constructs under the same conditions of attention. Participants ran continuously for one kilometer in one of three randomly assigned attentional focus conditions: internal-focus (n = 51), external-focus (n = 50), and control (n = 49). Self-efficacy was assessed using a one-item measure every 200 meters. Path analyses examining the primary objective revealed significant self-efficacy-to-performance pathways in all conditions: external-focus (p < .05, βs ranging from -.17 to -.32), internal-focus (p < .05, βs ranging from -.26 to -.36), and control (p < .05, βs ranging from -.29 to -.42). Significant reciprocal relationships were absent in all conditions. ANOVAs examining the secondary objectives found significantly faster performance in the control condition at the start (F (2, 147) = 3.86, p < .05) and end of the task (F (2, 147) = 3.56, p < .05). Self-efficacy was significantly higher in the internal-focus condition at the end of the task (Self-Efficacy 4 (F (2, 147) = 3.21, p < .05) and Self-Efficacy 5 (F (2, 147) = 4.74, p < .05). In contrast to previous within-trial research (e.g., LaForge-MacKenzie & Sullivan, 2014b) self-efficacy-to-performance effects were more significant and robust than performance-to-self-efficacy effects. These results provided support for Bandura’s (2012) suggestion that sociocognitive factors may have the ability to alter the causal structure of the self-efficacy-performance relationship, proposing complexities in the self-efficacy-performance relationship (Sitzmann &Yeo, 2013). Results were discussed from both theoretical and applied perspectives.
Resumo:
This paper proves a new representation theorem for domains with both discrete and continuous variables. The result generalizes Debreu's well-known representation theorem on connected domains. A strengthening of the standard continuity axiom is used in order to guarantee the existence of a representation. A generalization of the main theorem and an application of the more general result are also presented.
Resumo:
This paper considers various asymptotic approximations in the near-integrated firstorder autoregressive model with a non-zero initial condition. We first extend the work of Knight and Satchell (1993), who considered the random walk case with a zero initial condition, to derive the expansion of the relevant joint moment generating function in this more general framework. We also consider, as alternative approximations, the stochastic expansion of Phillips (1987c) and the continuous time approximation of Perron (1991). We assess how these alternative methods provide or not an adequate approximation to the finite-sample distribution of the least-squares estimator in a first-order autoregressive model. The results show that, when the initial condition is non-zero, Perron's (1991) continuous time approximation performs very well while the others only offer improvements when the initial condition is zero.
Resumo:
Le neurofeedback (NF) suscite actuellement un vif intérêt dans la prise en charge du trouble déficitaire de l’attention avec hyperactivité (TDAH) chez l’enfant. Proposée comme méthode alternative à la médication par de nombreux cliniciens, notamment aux États-Unis, le NF est une intervention non-invasive de type électrophysiologique qui repose sur l’apprentissage par conditionnement opérant de l’autorégulation d’ondes cérébrales déviantes. Les études empiriques qui étayent cette pratique font toutefois l’objet de virulentes critiques de la part de spécialistes dans le domaine du TDAH en raison de résultats systématiquement positifs mais non spécifiques, auxquels s’ajoutent de nombreuses lacunes méthodologiques. Les travaux de cette thèse visent à appliquer une méthodologie stricte de type essai clinique contrôlé avec assignation aléatoire afin d’isoler les effets particuliers du NF, en appliquant un protocole d’entraînement propre au déficit primaire sous-tendant le TDAH, soit l’inhibition motrice, dans le but d’évaluer la spécificité de cette intervention. Dans un premier temps, les connaissances relatives à la nosologie du TDAH, à ses principaux traitements, au NF et aux capacités d’inhibition chez l’enfant ayant un TDAH sont présentées (Chapitre 1). Ensuite, les études réalisées dans le cadre de cette thèse sont exposées. Dans l’étude initiale, la spécificité du NF est évaluée sur les capacités d’inhibition grâce à des mesures subjectives, soit des questionnaires de comportements complétés par les parents, ainsi que des mesures objectives, à savoir des tâches neuropsychologiques (Chapitre 2). Afin de préciser davantage les conséquences d’un entraînement à l’autorégulation d’ondes cérébrales, l’étude subséquente s’est intéressée à l’impact neurophysiologiques de l’amélioration des capacités d’inhibition, par le biais d’une étude en potentiels évoqués employant une tâche de performance continue de type Stop-signal (Chapitre 3). Les principaux résultats reflètent un recrutement sous optimal, avec une puissance statistique insuffisante pour réaliser des statistiques quantitatives de groupe. Néanmoins, l’appréciation des données selon une approche d’étude de cas multiples permet de mettre en évidence la présence d’une réponse placebo sur les capacités d’inhibition suite à un entraînement en NF. Finalement, les implications de la taille de l’échantillon, ainsi que les limites et les critiques de ces études sont discutées au Chapitre 4.