864 resultados para Consumo de energia - Indústria
Resumo:
Wireless Communication is a trend in the industrial environment nowadays and on this trend, we can highlight the WirelessHART technology. In this situation, it is natural the search for new improvements in the technology and such improvements can be related directly to the routing and scheduling algorithms. In the present thesis, we present a literature review about the main specific solutions for Routing and scheduling for WirelessHART. The thesis also proposes a new scheduling algorithm called Flow Scheduling that intends to improve superframe utilization and flexibility aspects. For validation purposes, we develop a simulation module for the Network Simulator 3 (NS-3) that models aspects like positioning, signal attenuation and energy consumption and provides an link individual error configuration. The module also allows the creation of the scheduling superframe using the Flow and Han Algorithms. In order to validate the new algorithms, we execute a series of comparative tests and evaluate the algorithms performance for link allocation, delay and superframe occupation. In order to validate the physical layer of the simulation module, we statically configure the routing and scheduling aspects and perform reliability and energy consumption tests using various literature topologies and error probabilities.
Resumo:
This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.
Resumo:
This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.
Resumo:
Cryptography is the main form to obtain security in any network. Even in networks with great energy consumption restrictions, processing and memory limitations, as the Wireless Sensors Networks (WSN), this is no different. Aiming to improve the cryptography performance, security and the lifetime of these networks, we propose a new cryptographic algorithm developed through the Genetic Programming (GP) techniques. For the development of the cryptographic algorithm’s fitness criteria, established by the genetic GP, nine new cryptographic algorithms were tested: AES, Blowfish, DES, RC6, Skipjack, Twofish, T-DES, XTEA and XXTEA. Starting from these tests, fitness functions was build taking into account the execution time, occupied memory space, maximum deviation, irregular deviation and correlation coefficient. After obtaining the genetic GP, the CRYSEED and CRYSEED2 was created, algorithms for the 8-bits devices, optimized for WSNs, i.e., with low complexity, few memory consumption and good security for sensing and instrumentation applications.
Resumo:
Cryptography is the main form to obtain security in any network. Even in networks with great energy consumption restrictions, processing and memory limitations, as the Wireless Sensors Networks (WSN), this is no different. Aiming to improve the cryptography performance, security and the lifetime of these networks, we propose a new cryptographic algorithm developed through the Genetic Programming (GP) techniques. For the development of the cryptographic algorithm’s fitness criteria, established by the genetic GP, nine new cryptographic algorithms were tested: AES, Blowfish, DES, RC6, Skipjack, Twofish, T-DES, XTEA and XXTEA. Starting from these tests, fitness functions was build taking into account the execution time, occupied memory space, maximum deviation, irregular deviation and correlation coefficient. After obtaining the genetic GP, the CRYSEED and CRYSEED2 was created, algorithms for the 8-bits devices, optimized for WSNs, i.e., with low complexity, few memory consumption and good security for sensing and instrumentation applications.
Resumo:
The thermodynamic performance of a refrigeration system can be improved by reducing the compression work by a particular technique for a specific heat removal rate. This study examines the effect of small concentrations of Al2O3 (50 nm) nanoparticles dispersion in the mineral oil based lubricant on the: viscosity, thermal conductivity, and lubrication characteristics as well as the overall performance (based on the Second Law of Thermodynamics) of the refrigerating system using R134a or R600a as refrigerants. The study looked at the influences of variables: i) refrigerant charge (100, 110, 120 and 130 g), ii) rotational speed of the condenser blower (800 and 1100 RPM) and iii) nanoparticle concentration (0.1 and 0.5 g/l) on the system performance based on the Taguchi method in a matrix of L8 trials with the criterion "small irreversibility is better”. They were carried pulldown and cycling tests according to NBR 12866 and NBR 12869, respectively, to evaluate the operational parameters: on-time ratio, cycles per hour, suction and discharge pressures, oil sump temperature, evaporation and condensation temperatures, energy consumption at the set-point, total energy consumption and compressor power. In order to evaluate the nanolubricant characteristics, accelerated tests were performed in a HFRR bench. In each 60 minutes test with nanolubricants at a certain concentration (0, 0.1 and 0.5 g/l), with three replications, the sphere (diameter 6.00 ± 0.05 mm, Ra 0.05 ± 0.005 um, AISI 52100 steel, E = 210 GPa, HRC 62 ± 4) sliding on a flat plate (cast iron FC200, Ra <0.5 ± 0.005 um) in a reciprocating motion with amplitude of 1 mm, frequency 20 Hz and a normal load of 1,96 N. The friction coefficient signals were recorded by sensors coupled to the HFRR system. There was a trend commented bit in the literature: a nanolubricant viscosity reduction at the low nanoparticles concentrations. It was found the dominant trend in the literature: increased thermal conductivity with increasing nanoparticles mass fraction in the base fluid. Another fact observed is the significant thermal conductivity growth of nanolubricant with increasing temperature. The condenser fan rotational speed is the most influential parameter (46.192%) in the refrigerator performance, followed by R600a charge (38.606%). The Al2O3 nanoparticles concentration in the lubricant plays a minor influence on system performance, with 12.44%. The results of power consumption indicates that the nanoparticles addition in the lubricant (0.1 g/L), together with R600a, the refrigerator consumption is reduced of 22% with respect to R134a and POE lubricant. Only the Al2O3 nanoparticles addition in the lubricant results in a consumption reduction of about 5%.
Resumo:
The thermodynamic performance of a refrigeration system can be improved by reducing the compression work by a particular technique for a specific heat removal rate. This study examines the effect of small concentrations of Al2O3 (50 nm) nanoparticles dispersion in the mineral oil based lubricant on the: viscosity, thermal conductivity, and lubrication characteristics as well as the overall performance (based on the Second Law of Thermodynamics) of the refrigerating system using R134a or R600a as refrigerants. The study looked at the influences of variables: i) refrigerant charge (100, 110, 120 and 130 g), ii) rotational speed of the condenser blower (800 and 1100 RPM) and iii) nanoparticle concentration (0.1 and 0.5 g/l) on the system performance based on the Taguchi method in a matrix of L8 trials with the criterion "small irreversibility is better”. They were carried pulldown and cycling tests according to NBR 12866 and NBR 12869, respectively, to evaluate the operational parameters: on-time ratio, cycles per hour, suction and discharge pressures, oil sump temperature, evaporation and condensation temperatures, energy consumption at the set-point, total energy consumption and compressor power. In order to evaluate the nanolubricant characteristics, accelerated tests were performed in a HFRR bench. In each 60 minutes test with nanolubricants at a certain concentration (0, 0.1 and 0.5 g/l), with three replications, the sphere (diameter 6.00 ± 0.05 mm, Ra 0.05 ± 0.005 um, AISI 52100 steel, E = 210 GPa, HRC 62 ± 4) sliding on a flat plate (cast iron FC200, Ra <0.5 ± 0.005 um) in a reciprocating motion with amplitude of 1 mm, frequency 20 Hz and a normal load of 1,96 N. The friction coefficient signals were recorded by sensors coupled to the HFRR system. There was a trend commented bit in the literature: a nanolubricant viscosity reduction at the low nanoparticles concentrations. It was found the dominant trend in the literature: increased thermal conductivity with increasing nanoparticles mass fraction in the base fluid. Another fact observed is the significant thermal conductivity growth of nanolubricant with increasing temperature. The condenser fan rotational speed is the most influential parameter (46.192%) in the refrigerator performance, followed by R600a charge (38.606%). The Al2O3 nanoparticles concentration in the lubricant plays a minor influence on system performance, with 12.44%. The results of power consumption indicates that the nanoparticles addition in the lubricant (0.1 g/L), together with R600a, the refrigerator consumption is reduced of 22% with respect to R134a and POE lubricant. Only the Al2O3 nanoparticles addition in the lubricant results in a consumption reduction of about 5%.
Resumo:
This paper analyses the sustainability under the environmental (ecological) perspective of Water Supply and Sanitary Sewers Systems from Uberaba city, MG. It was accomplished in this analysis, An Environmental Sustainability Assessment of those systems, by the means of specific sustainability indicators proposed for Uberaba, but which may be used for other simi-lar cities. To the characterization of the systems, visitations were made to the main units as well as a documental was elaborated. The definition of the level or stage of the sustainability by the indicators was made based on a literature review, on interviews with the technicians and managers of the systems and based on the characterization and observation of the system reality, being attributed to them the following classification: Non Sustainable, Low Sustaina-bility, Medium Sustainability and High Sustainability. It was verified that the indicators that have lower compatibility to the process of sustainability to the studied systems are those rela-ted to the water physical losses, to the water per capita consumption, to the electricity con-sumption and to the sludge from the water treatment plants disposal untreated into a water body, for the Water Supply System. And those ones related to the attendance with sewage treatment, to the electricity consumption and to the usage of the treated sewage, for the Sani-tary Sewers, all of them classified as Non Sustainable.
Resumo:
A crescente evolução da utilização das Tecnologias de Informação (TI), nomeadamente em instituições e empresas, faz com que exista um aumento no consumo da energia elétrica e elevados custos de manutenção associados. Com esta situação, existe cada vez mais a preocupação em arranjar formas/técnicas de baixar este consumo, isto é, a necessidade de gerir estes consumos de forma a que se consiga baixar a fatura energética. O presente trabalho tem como objetivo estudar possibilidades de eficiência energética associado a um parque informático distribuído, nomeadamente estudar o que pode ser feito para reduzir consumos num edifício escolar, utilizando como caso de estudo uma escola do Instituto Politécnico de Leiria. Esta dissertação apresenta diferentes propostas de modo a que se consigam reduzir os consumos energéticos, nomeadamente com a substituição de equipamentos por outros mais eficientes. Numa parte inicial, o trabalho abrange uma visão global sobre técnicas que têm vindo a ser desenvolvidas para melhorar a eficiência energética em sistemas computacionais. Efetuaram-se medições de consumos, tanto em equipamentos como em sala, durante um período experimental, de modo a obter conclusões sobre os valores obtidos com a substituição dos equipamentos existentes por equipamentos eficientes.
Resumo:
Na ultima década, a necessidade da definição de objectivos de gestão por parte das entidades gestoras, e a correspondente necessidade de verificação do cumprimento dos objectivos estabelecidos, levaram à implementação de iniciativas para o estudo e desenvolvimento de metedologias no domínio de avaliação de desempenho dos serviços de saneamento. O presente trabalho tem como principal objectivo, a avaliação do desempenho das nove infraestruturas em exploração pela SIMLIS, SA, tendo-se seleccionado, para este efeito, doze indicadores de desempenho,distribuídos pelos domínios da qualidade da água tratada; da eficiência e fiabilidade da ETAR; da utilização de água, energia e materiais; e da gestão de subprodutos. Como aspectos da avaliação de desempenho foram seleccionados, a conformidade com a licença de descarga, a qualidade da água rejeitada no meio recetor, a eficiência global da ETAR, o consumo de energia, o consumo de reagentes, a utilização de águas residuais tratadas, a produção e valorização de lamas e a produção de biogás. Para o processo de avaliação de desempenho, definiu-se um período de análise de um ano, nomeadamente o ano de 2013, para o qual se estabeleceram metas para cada um dos indicadores a avaliar. Conclui-se que a avaliação de desempenho é uma ferramenta essencial à gestão, pois permitiu analisar, não só o desempenho global da entidade gestora, mas também, avaliar o desempenho individual de cada uma das infraestruturas. Foi ainda possível, em alguns casos, avaliar o desempenho das ETAR em função do tipo de processo de tratamento utilizado. O uso adequado desta ferramenta de avaliação de desempenho permitiu à SIMLIS, de uma forma mais eficiente, aplicar acções correctivas quando identificados problemas e optimizar recursos, sendo usada como ferramenta de apoio à decisão.
Resumo:
PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em:
Resumo:
O crescente consumo de energia, bem como a possibilidade de esgotamento dos recursos não renováveis, tem fomentado a busca de fontes de energia alternativas. O biodiesel é um biocombustível obtido a partir de fontes renováveis e a sua utilização permite reduzir as emissões de gases com efeito de estufa. Nos últimos anos tem-se produzido biodiesel a partir de óleos alimentares usados (OAU), sendo que com esta aplicação valoriza-se um resíduo e simultaneamente produz-se um combustível “verde”. O biodiesel é produzido através das reações de transesterificação e/ou esterificação entre triglicerídeos e/ou ácidos gordos livres e um álcool, na presença de um catalisador. O rendimento do processo está estritamente relacionado com o tipo de catalisador e as condições que este opera. O principal objetivo do presente trabalho consistiu na avaliação do efeito de alguns parâmetros operacionais no desempenho de uma lípase imobilizada (Novozyme® 435), nomeadamente: (i) índice de acidez do óleo, (ii) razão mássica de enzima/óleo e (iii) método regeneração da enzima com vista à sua reutilização. Também foi objeto de estudo do presente trabalho a produção em contínuo, num (bior)reator tubular de leito fixo, de ésteres metílicos de ácidos gordos (FAME) usando a referida enzima. Registou-se um aumento rendimento em com o incremento do índice de acidez do óleo usado, o que indicia que a enzima catalisa simultaneamente as reações de esterificação e transesterificação. Relativamente à razão mássica de enzima/óleo, dentro da gama testada verificou-se um aumento do rendimento em FAME com a concentração da enzima em meio reacional. Dos vários solventes testados, a aplicação de solvente tert-butanol na regeneração (com incubação) da enzima foi o que melhores resultados teve. Finalmente, os resultados obtidos no ensaio de produção de FAME num biorreator contínuo são motivadores, criando expectativas de uma possível aplicação industrial no futuro.
Resumo:
The consumption of energy on the planet is currently based on fossil fuels. They are responsible for adverse effects on the environment. Renewables propose solutions for this scenario, but must face issues related to the capacity of the power supply. Wind energy offshore emerging as a promising alternative. The speed and stability are greater winds over oceans, but the variability of these may cause inconvenience to the generation of electric power fluctuations. To reduce this, a combination of wind farms geographically distributed was proposed. The greater the distance between them, the lower the correlation between the wind velocity, increasing the likelihood that together achieve more stable power system with less fluctuations in power generation. The efficient use of production capacity of the wind park however, depends on their distribution in marine environments. The objective of this research was to analyze the optimal allocation of wind farms offshore on the east coast of the U.S. by Modern Portfolio Theory. The Modern Portfolio Theory was used so that the process of building portfolios of wind energy offshore contemplate the particularity of intermittency of wind, through calculations of return and risk of the production of wind farms. The research was conducted with 25.934 observations of energy produced by wind farms 11 hypothetical offshore, from the installation of 01 simulated ocean turbine with a capacity of 5 MW. The data show hourly time resolution and covers the period between January 1, 1998 until December 31, 2002. Through the Matlab R software, six were calculated minimum variance portfolios, each for a period of time distinct. Given the inequality of the variability of wind over time, set up four strategies rebalancing to evaluate the performance of the related portfolios, which enabled us to identify the most beneficial to the stability of the wind energy production offshore. The results showed that the production of wind energy for 1998, 1999, 2000 and 2001 should be considered by the portfolio weights calculated for the same periods, respectively. Energy data for 2002 should use the weights derived from the portfolio calculated in the previous time period. Finally, the production of wind energy in the period 1998-2002 should also be weighted by 1/11. It follows therefore that the portfolios found failed to show reduced levels of variability when compared to the individual production of wind farms hypothetical offshore
Resumo:
O gradual consumo de energia primária a nível mundial deu origem a uma crise não só ambiental como também económica, proveniente das limitações das reservas energéticas e do fornecimento. Estas inquietações têm levado a um estudo cada vez mais aprofundado no que concerne à eficiência energética de edifícios. É neste contexto que surge o estudo da aplicação dos materiais de mudança de fase (PCM) na térmica dos edifícios. O presente trabalho consiste no estudo da influência da introdução de materiais de mudança de fase no comportamento térmico de um edifício. Foi analisada uma simulação numérica para um sistema solar passivo de ganho direto, por um programa de simulação designado EXTEND™. Efetuou-se, também, o estudo paramétrico de determinadas propriedades associadas aos materiais de mudança de fase. Após a análise, foi testado o impacto, em termos de conforto, da utilização de materiais de mudança de fase em sistemas solares passivos de ganho direto.
Resumo:
Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior