986 resultados para Concertos (Piano with chamber orchestra)
Resumo:
A laboratory setup was designed and put into operation for the development of solid oxide fuel cells (SOFCs). The whole project consisted of the preparation of the component materials: anode, cathode and electrolyte, and the buildup of a hydrogen leaking-free sample chamber with platinum leads and current collectors for measuring the electrochemical properties of single SOFCs. Several anode-supported single SOFCs of the type (ZrO(2):Y(2)O(3)+NiO) thick anode/(ZrO(2):Y(2)O(3)) thin electrolyte/(La(0.65)Sr(0.35)MnO(3)+ZrO(2):Y(2)O(3)) thin cathode have been prepared and tested at 700 and 800 degrees C after in situ H(2) anode reduction. The main results show that the slurry-coating method resulted in single-cells with good reproducibility and reasonable performance, suggesting that this method can be considered for fabrication of SOFCs. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Statement of problem. During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis.Purpose. The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser.Material and methods. Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark oil the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degreesC). Analysis was performed on the following groups (n = 10): Group 1, high-speed handpiece without water cooling, Group 11, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 mum at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha = .05).Results. The average temperature rises were: 11.64degreesC (+/-4.35) for Group 1, 0.96degreesC (+/-0.71) for Group 11, and 2.69degreesC (+/-1.12) for Group III. There were no statistical differences between Groups 11 and III, both 11 and III differed from Group I significantly (P = .000 and P = .002, respectively).Conclusion. The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser.
Resumo:
The use of oxygen to enrich the oxidizer can be an attractive alternate to increase incineration rates of a combustion chamber originally designed to operate with air. For a certain fuel now rate, if some incineration parameters are held constant (as combustion chamber temperature, turbulence level, and residence time), an increase of incineration rates becomes possible with injection of oxygen. This work presents a theoretical evaluation of combustion air enrichment in a combustion chamber designed to incinerate aqueous residues using methane as fuel and air as oxidizer. Detailed chemistry was employed to predict pollutants formation. The overall process was investigated using the PSR routine from the CHEMKIN library. (C) 1999 Elsevier B.V. Ltd.
Resumo:
When a crown fracture involving pulpal exposure is produced, the therapeutic treatment to be applied depends to a great extent on the general histopathological condition of the exposed pulp. Hence, the objective of this study was to evaluate histopathological and bacteriological changes occurring in dental tissue and periradicular tissue of crown-fractured teeth with pulpal exposure. Twenty-four anterior teeth (central and lateral incisors) from the maxillary teeth of four young, adult Mongrel dogs were used. At 48 and 72 h after performing the crown fractures, the animals were sacrificed and the results evaluated. Both observation periods revealed the existence of an area of superficial inflammation with the formation of hyperplastic tissue towards the external surface. Intense neutrophilic infiltrate was observed below it. Mean depth of inflammation was greater at 48 h (4633.33 mum) than at 72 h (3933.33 mum), perhaps coinciding with the bigger pulp chamber opening (x1332.14 mum at 48 h vs. x479.52 mum at 72 h). Upon approaching the cervical portion, the inflammation became less. Bacterial contamination was constant in all the cases evaluated, worsening the histopathological findings with exposure time. This study demonstrates that when a crown fracture with pulpal exposure is produced, the success in treating it depends partly on how quickly therapeutic treatment is administered.
Resumo:
A flow-injection system for multielemental analysis with a mercury(II) preconcentration step using a resin Chelite-S(R)(Serva Feinbiochemica Heidelberg, Part No. 41709) packed minicolumn by inductively coupled plasma atomic emission spectroscopy is described. A mercury reductive elution procedure with a mixture of SnCl2/HCl was used, which allows use of 6 mol/L HCl solution instead of concentrated hydrochoric acid. The main parameters related to ICP operation, such as radio frequency power (950-1750 W), auxiliary argon flow (0.0-1.5 L/min) and spray chamber nebulizer pressure (15-35 psi), were studied. Optimization of the FIA system was reached by defining the best eluent carrier stream (1.4-2.8 mL/min), Hgdegrees carrier stream (10-40 mL min(-1)), loading time (0.5-4.0 min), sample flow rate (1.25-10.0 mL/min), temperature of reactor gas liquid separator (GLS) (25-75 degreesC) and eluent volume (50-350 muL). Throughput is around 30 samples per hour for analytical solutions within the range 50-2500 ng Hg(II)/L. Results from certified material showed good precision (RSD < 3%, n = 12) and no statistical difference was observed for real samples analyzed by AAS and by the proposed system.
Resumo:
Purpose To compare the effects of travoprost 0.004% and latanoprost 0.005% on the intraocular pressure (IOP) of normal dogs.Methods Twenty mixed breed dogs were randomized to two groups: latanoprost was used in group A and travoprost in group B. The drugs were instilled in the right eye of the dogs, whereas the left eye received placebo. Both drugs were instilled once a day at 8 AM during 5 days. IOP measurements were made at 8 AM, 10 AM, 2 PM and 8 PM during the 5 days of treatment, the 3 days that preceded treatment, and 3 days following treatment. Presence of blepharospasm, miosis, anterior chamber flare, and conjunctival hyperemia were evaluated during the study.Results Mean IOP was significantly reduced in the eyes treated with both latanoprost and travoprost, when compared with the eyes treated with placebo (P < 0.05). There was no statistically significant difference between the mean IOPs of eyes treated with latanoprost and travoprost at all time intervals during baseline, treatment, and recovery (P > 0.05). on the fifth day of treatment and on the first day of the recovery period, a severe ocular hypotension was noted with both drugs, resulting in imprecise readings with the tonometer. Miosis and conjunctival hyperemia were observed in the treated eyes of both groups, whereas flare was noticed in one latanoprost-treated eye.Conclusion Travoprost 0.004% significantly reduces the IOP in normal dogs. The hypotensive effect obtained with travoprost 0.004% is comparable to that obtained with latanoprost 0.005%.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to evaluate the amount of peroxide passage from the pulp chamber to the external enamel surface during the internal bleaching technique. Fifty bovine teeth were sectioned transversally 5 mm below the cemento-enamel junction (CEJ), and the remaining part of the root was sealed with a 2-mm layer of glass ionomer cement. The external surface of the samples was coated with nail varnish, with the exception of standardized circular areas (6-mm diameter) located on the enamel, exposed dentin, or cementum surface of the tooth. The teeth were divided into three experimental groups according to exposed areas close to the CEJ and into two control groups (n=10/group), as follows: GE, enamel exposure area; GC, cementum exposed area; GD, dentin exposed area; Negative control, no presence of internal bleaching agent and uncoated surface; and Positive control, pulp chamber filled with bleaching agent and external surface totally coated with nail varnish. The pulp chamber was filled with 35% hydrogen peroxide (Opalescence Endo, Ultradent). Each sample was placed inside of individual flasks with 1000 mu L of acetate buffer solution, 2 M (pH 4.5). After seven days, the buffer solution was transferred to a glass tube, in which 100 mu L of leuco-crystal violet and 50 mu L of horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to Kruskal-Wallis and Dunn-Bonferroni tests (alpha=0.05). All experimental groups presented passage of peroxide to the external surface that was statistically different from that observed in the control groups. It was verified that the passage of peroxide was higher in GD than in GE (p<0.01). The GC group presented a significantly lower peroxide passage than did GD and GE (p<0.01). It can be concluded that the hydrogen peroxide placed into the pulp chamber passed through the dental hard tissues, reaching the external surface and the periodontal tissue. The cementum surface was less permeable than were the dentin and enamel surfaces.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Aiming to assess the presence of selected anaerobic microorganisms in root canals of human teeth with chronic apical periodontitis, 25 central and lateral upper incisors presenting with radiographic evidence of chronic apical periodontitis were studied. The pulp chamber was opened under aseptic conditions and samples of the root canal content were collected with sterile absorbent paper points, which were placed and dispersed in test tubes containing reduced transport medium (RTF). Aliquots were dried on glass slides and stained by indirect immunofluorcscencc for detection of Actinomyces viscosus, Fusobacterium nucleatum, Porphyromonas gingivalis and Prevotella intermedia. The results showed a positive indirect immunofluorescence reaction in 24 of the 25 samples. Fourteen were positive for the specie Actinomyces viscosus, 12 for Prevotella intermedia, 10 for Fusobacterium nucleatum and 4 for Porphyromonas gingivalis. A semiquantitative assay was easily implemented for assessment of degree of infection by the organisms in individual cases. © Munksgaard, 1996.
Resumo:
Aim: To investigate pulp chamber penetration of bleaching agents in teeth following restorative procedures. Methodology: Bovine lateral incisors were sectioned 3 mm apical to the cemento-enamel junction and the coronal pulpal tissue was removed. Teeth were divided into six groups (n = 10): G1, G2 and G3 were not submitted to any restorative procedure, while G4, G5 and G6 were submitted to Class V preparations and restored with composite resin. Acetate buffer was placed in the pulp chamber and treatment agents were applied for 60 min at 37°C as follows: G1 and G4, immersion into distilled water; G2 and G5, 10% carbamide peroxide (CP) exposure; G3 and G6, 35% CP bleaching. The buffer solution was removed and transferred to a glass tube where leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined spectrophotometrically at 596 nm. A standard curve made with known amounts of hydrogen peroxide was used to convert the optical density values of the coloured samples into microgram equivalents of hydrogen peroxide. Data were submitted to ANOVA and Tukey's test (5%). Results: Amounts of hydrogen peroxide found in the pulp chamber of G2 and G5 specimens (0.1833 ± 0.2003 μg) were significantly lower (P = 0.001) when compared to G3 and G6 specimens (0.4604 ± 0.3981 μg). Restored teeth held significantly higher (P = 0.001) hydrogen peroxide concentrations in the pulp chamber than intact teeth. Conclusion: Higher concentrations of the bleaching agent produced higher levels of hydrogen peroxide in the pulp chamber, especially in restored teeth.
Resumo:
An experimental study has been conducted with the objective of investigating the effects of the flame structure in the combustion oscillation conditions into a laboratorial scale cylindrical chamber. The experiments were conducted in a water-jacketed 1-m long by 25-cm internal diameter stainless steel vertical tube. The combustor operated with liquefied petroleum gas (LPG) in both oscillatory and non oscillatory conditions, under the same input conditions. Part of the reactant mixture was excited acoustically, before the burner exit, by a speaker positioned strategically. The burner was aligned with the chamber longitudinal axis and positioned at its bottom. The experiments were conducted for 0.16 g/s of LPG burning in stoichiometric equivalence ratio. To analyze the flame structure the image tomographic reconstruction process were used, and the resultant images were associated to the oscillatory conditions (frequency and amplitude) into the combustion chamber. The main conclusions were: 1) when the flame premixed condition increase, for example 60% of the total air flow rate is premixed with LPG, the region of intense energy released is close to burner exit and strong amplitudes of oscillation (close to 50 mbar) were obtained into the chamber; 2) for long flames, predominantly diffusive flames, just weak amplitudes were detected, in the spite of the speaker exiting the premixed flow; 3) when the energy is released distributed through the combustion chamber, the long flame acts like a baffle. Copyright © 2006 by the American Institute of Aeronautics and Astronautics, Inc. All rights reserved.
Resumo:
Electric propulsion is now a succeful method for primary propulsion of deep space long duration missions and for geosyncronous satellite attitude control. Closed Drift Thruster, so called Hall Thruster or SPT (Stationary Plasma Thruster), was primarily conceived in USSR (the ancient Soviet Union) and, since then, it has been developed by space agencies, space research institutes and industries in several countries such as France, USA, Israel, Russian Federation and Brazil. In this work we present the main features of the Permanent Magnet Hall Thruster (PMHT) developed at the Plasma Laboratory of the University of Brasilia. The idea of using an array of permanent magnets, instead of an electromagnet, to produce a radial magnetic field inside the plasma channel of the thruster is very significant. It allows the development of a Hall Thruster with power consumption low enough to be used in small and medium size satellites. Description of a new vacuum chamber used to test the second prototype of the PMHT (PHALL II) will be given. PHALL II has an aluminum plasma chamber and is smaller with 15 cm diameter and will contain rare earth magnets. We will show plasma density and temperature space profiles inside and outside the thruster channel. Ion temperature measurements based on Doppler broadening of spectral lines and ion energy measurements are also shown. Based on the measured plasma parameters we constructed an aptitude figure of the PMHT. It contains the specific impulse, total thrust, propellant flow rate and power consumption necessary for orbit raising of satellites. Based on previous studies of geosyncronous satellite orbit positioning we perform numerical simulations of satellite orbit raising from an altitude of 700 km to 36000 km using a PMHT operating in the 100 mN - 500 mN thrust range. In order to perform these calculations integration techniques were used. The main simulation paraters were orbit raising time, fuel mass, total satellite mass, thrust and exaust velocity. We conclude comparing our results with results obtainned with known space missions performed with Hall Thrusters. © 2008 by the American Institute of Aeronautics and Astronautics, Inc.
Resumo:
This study evaluated the Influence of the coloring agent concentration on the temperature of the gel layer and pulp chamber during dental bleaching with an LED/laser light source. Ten human incisors and a digital thermometer with K-type thermocouples were used. Using a high-speed spherical diamond bur, endodontic access was gained through openings on the lingual faces until pulp chamber was exposed. One end of the thermocouple was placed on the labial surface (immersed in bleaching gel) and the other end in the pulp chamber. The same 10 specimens were used in the 12 groups, according to the type and concentration of bleaching gel. Each bleaching gel was used in four different concentrations: manipulated without coloring, with normal quantity recommended by the manufacturer, with double the recommended amount of coloring, and with triple the recommended amount of coloring. The temperature rise was measured every 30 seconds for three minutes with a K-type thermocouple. The data were analyzed by ANOVA to examine the concentration and type of bleaching gel. This test was followed by Tukey's test, which was performed Independently for the gel at the labial surface and the pulp chamber (a = 5%). For both surfaces, values of p = 0.00 were obtained for all factors and for the Interaction between them. The varying concentrations of coloring agent produced statistically significant differences in terms of temperature increase for both the gel layer and the pulp chamber during activation.
Resumo:
AIM: This study evaluated the temperature rise of the adhesive system Single Bond (SB) and the composite resins Filtek Z350 flow (Z) and Filtek Supreme (S), when polymerized by light-emitting diode (LED XL 3000) and quartz-tungsten halogen (QTH Biolux). METHODS: Class V cavities (3 yen2 mm) were prepared in 80 bovine incisors under standardized conditions. The patients were divided as follows: G1: Control; G2: SB; G3: SB + Z; G4: SB + S. The groups were subdivided into two groups for polymerization (A: QTH, B: LED). Light curing was performed for 40 s and measurement of temperature changes during polymerization was performed with a thermocouple positioned inside the pulp chamber. Data were statistically analyzed using ANOVA and Tukey tests. RESULTS: The factors material (P<0.00001) and curing unit (P<0.00001) had significant influence on temperature rise. The lowest temperature increase (0.15 degrees C) was recorded in G2 B and the highest was induced in G1 A (0.75 degrees C, P<0.05). In all groups, lower pulp chamber temperature measurements were obtained when using LED compared to QTH (P<0.05). CONCLUSION: QTH caused greater increases in tooth temperature than LED. However, both sources did not increase pulpal temperature above the critical value that may cause pulpal damage.