799 resultados para Conceptualizing and Measuring


Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is increased interest in measuring kinetic rates, lifetimes, and rupture forces of single receptor/ligand bonds. Valuable insights have been obtained from previous experiments attempting such measurements. However, it remains difficult to know with sufficient certainty that single bonds were indeed measured. Using exemplifying data, evidence supporting single-bond observation is examined and caveats in the experimental design and data interpretation are identified. Critical issues preventing definitive proof and disproof of single-bond observation include complex binding schemes, multimeric interactions, clustering, and heterogeneous surfaces. It is concluded that no single criterion is sufficient to ensure that single bonds are actually observed. However, a cumulative body of evidence may provide reasonable confidence. 0 2002 Biomedical Engineering Society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An optical diagnostic system consisting of the Michelson interferometer with the image processor has been developed for the study of the kinetics of the thermal capillary convection. The capillary convection, surface deformation, surface wave and the velocity field in a rectangular cavity with different temperature's sidewalls have been investigated by optical interference method and PIV technique. In order to calculate the surface deformation from the interference fringe, Fourier transformation is used to grating analysis. The quantitative results of the surface deformation and surface wave have been calculated from the interference fringe pattern.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Based on the computer integrated and flexible laser processing system, develop the intelligent measuring sub-system. A novel model has been built to compensate the deviations of the main frame, a new-developed 3-D laser tracker system is applied to adjust the accuracy of the system. Analyzing the characteristic of all kinds of automobile dies, which is the main processing object of the laser processing system, classify the types of the surface and border needed to be measured and be processed. According to different types of surface and border, develop 2-D adaptive measuring method based on B?zier curve and 3-D adaptive measuring method based on spline curve. During the data processing, a new 3-D probe compensation method has been described in details. Some measuring experiments and laser processing experiments are carried out to testify the methods. All the methods have been applied in the computer integrated and flexible laser processing system invented by the Institute of Mechanics, CAS.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Using second-order autocorrelation conception, a novel method and instrument for accurately measuring interval between two linearly polarized ultrashort pulses with real time were presented. The experiment demonstrated that the measuring method and instrument were simple and accurate (the measurement error <5 fs). During measuring, there was no moving element resulting in dynamic measurement error.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Based on the Mach-Zehnder effect between the core mode and the cladding modes, the interference fringes are formed by a pair of cascaded long-period fiber gratings (CLPFGs). Theoretical analyses show that the spectral spacing and the wavelength of these fringes are functions of the waveguide dispersion factor gamma, which is a characterizing parameter to LPFG and with theoretical and applicational significance. By measuring the characteristics of the transmission spectra of CLPFGs, the absolute value of gamma can be obtained. At the same time, the thermo-optic coefficient of effective refractive index difference between core and cladding modes, p, can also be obtained by measured the temperature sensitivity of these fringes. In the experiments, \gamma\ and mu were measured by this method to be 0.874 and 4.08 x 10(-5) degreesC(-1), respectively, for LPFGs with period of 450 mum and with a HE14 resonant peak at 1554 nm. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A review article detailing the background, development and functionality of the Windermere Profiler, a multi parameter environmental monitoring instrument for use in lakes, reservoirs and rivers. The article explains the requirement for regular data collection by the Freshwater Biological Association at Windermere. The article covers the requirements of a profiling instrument, the design considerations, the electronic circuitry, the computer program, the operation of the computer software, the profiler in use and further developments to the design. A number of figures and images accompany the article.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The application of digital holographic interferometry on the quantitative measurement of the domain inversion in a RuO2: LiNbO3 crystal wafer is presented. The recorded holograms are reconstructed by the angular spectrum method. From the reconstructed phase distribution we can clearly observe the boundary between the inverted and un-inverted domain regions. Comparisons with the results reconstructed by use of the Fresnel transform method are given. Factors that influence the measurement include the spectrum filter size and the spectrum movement are discussed. The spectrum filter size has an effect on the measurement of the details. Although the spectrum movement affects every single reconstructed image, it has no influence on the final measurement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For a research organization such as ICLARM which carries out long-term basic research, justifying money spent can be a difficult exercise. This articles examines different ways by which impact of ICLARM research can be measured.