840 resultados para Computer-assisted instruction--Evaluation.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The problem of achieving super-resolution, i.e. resolution beyond the classical Rayleigh distance of half a wavelength, is a real challenge in several imaging problems. The development of computer-assisted instruments and the possibility of inverting the recorded data has clearly modified the traditional concept of resolving power of an instrument. We show that, in the framework of inverse problem theory, the achievable resolution limit arises no longer from a universal rule but instead from a practical limitation due to noise amplification in the data inversion process. We analyze under what circumstances super-resolution can be achieved and we show how to assess the actual resolution limits in a given experiment, as a function of the noise level and of the available a priori knowledge about the object function. We emphasize the importance of the a priori knowledge of its effective support and we show that significant super-resolution can be achieved for "subwavelength sources", i.e. objects which are smaller than the probing wavelength.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is about performance assessment in serious games. We conceive serious gaming as a process of player-lead decision taking. Starting from combinatorics and item-response theory we provide an analytical model that makes explicit to what extent observed player performances (decisions) are blurred by chance processes (guessing behaviors). We found large effects both theoretically and practically. In two existing serious games random guess scores were found to explain up to 41% of total scores. Monte Carlo simulation of random game play confirmed the substantial impact of randomness on performance. For valid performance assessments, be it in-game or post-game, the effects of randomness should be included to produce re-calibrated scores that can reasonably be interpreted as the players´ achievements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is abound the research on the formation, rise and failure of the financial and industrial network undertaken by the Loring-Heredia-Larios triangle, bourgeois families who introduced the Industrial Revolution in the south of Andalusia. On the contrary, there are almost nonexistent studies from the perspective of the mentality that sustained their business, social and ethical model in the algid decades of their action (1850-1860). In this paper we propose some hypotheses about the ideological structures of bourgeois group and point out some keys, clues and signs for a future reconstruction of this kind, which so far has not been incardinated that early and failed malaguenan industrial revolution in streams thinking of that time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To investigate effects of cryopreservation on sperm motility and DNA integrity. Design: Pre-cryopreservation and post-cryopreservation analysis of motility and DNA integrity of semen and prepared sperm samples. Setting: A hospital andrology laboratory. Patient(s): Forty men attending the Regional Fertility Centre, Belfast, Northern Ireland. Intervention(s): Each sample was divided, and an aliquot was frozen unprepared. Remaining aliquots were prepared by Percoll density centrifugation (95.0:47.5) or direct swim-up procedure and divided into aliquots to allow direct comparison of fresh and frozen semen and prepared sperm (frozen with or without the addition of seminal plasma) from the same ejaculate. Samples were frozen by static-phase vapor cooling and being plunged into liquid nitrogen. Thawing was carried out at room temperature. Main Outcome Measure(s): Sperm DNA integrity was determined using a modified alkaline single cell gel electrophoresis (comet) assay, and motility was determined using computer-assisted semen analysis. Result(s): Sperm frozen unprepared in seminal fluid appeared more resistant to freezing damage than frozen prepared sperm. Further improvements can be achieved by selecting out the subpopulation of sperm with best motility and DNA integrity and freezing these sperm in seminal plasma, making this the optimal procedure. Conclusion(s): Freezing sperm in seminal plasma improves postthaw motility and DNA integrity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: to investigate the effects of tetrahydrocannabinol; THC on human sperm function in vitro. Design: laboratory analysis of sperm motility with and without exposure to THC using computer assisted semen analysis (CASA) and acrosome reaction by fluoroscein isothiocyanate labelled peanut agglutinin (FITC-PNA) staining. Setting: An ART unit in a tertiary medical centre. Patients: semen was obtained from 78 men attending the Regional Fertility Centre, Belfast. Interventions: Sperm were divided into 90% (the best fertilizing potential used in assisted conception) and 45% (the poorer subpopulation) fractions by density centrifugation and incubated with, or without (controls), tetrahydrocannabinol (THC) at concentrations equivalent to therapeutic (0.032�?�¯?�?�­M) and recreational (4.8 and 0.32�?�¯?�?�­M) plasma levels, at 37�?�¯?�?�°C for 3 hours. Main outcome measures: Sperm motility, spontaneous and induced acrosome reactions Results: There was a dose-dependent decrease in percentage progressive motility (-21% at 4.8�??�?�µM, p0.05) in the 90% fraction. The 45% fraction showed a greater decrease in percentage progressive motility (-56% at 4.8�??�?�µM, p=0.011; -23% at 0.32�??�?�µM, p= 0.039; and -28% at 0.032�??�?�µM, p=0.004). A decrease in the straight line velocity; VSL (-10%) and the average path velocity; VAP (-10%) were also observed in the 90% fraction. A significant inhibition (-15% at 4.8�??�?�µM, p=0.04) in spontaneous acrosome reaction was observed in the 90% fraction. The 45% fraction showed a more marked inhibition [-35% (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: to determine if sildenafil citrate; a cyclic monophosphate specific type 5 phosphodiesterase inhibitor, influences sperm motility or the acrosome reaction. Design: laboratory analysis of sperm motility after exposure to sildenafil citrate using computer assisted semen analysis (CASA) and acrosome reaction by fluoroscein isothiocyanate labelled peanut agglutinin (FITC-PNA) staining. Setting: An ART unit Patients: 57 male patients Interventions: Sperm were divided into 90% (the best fertilizing potential used in assisted conception) and 45% (the poorer subpopulation) fractions by density centrifugation and incubated with sildenafil citrate ( 0.67uM) at 37ï?°C for up to 180 minutes. Main outcome measures: both the numbers and velocity of progressively motile sperm were significantly increased by sildenafil citrate between 15 and 135 minutes. Further, samples revealed that these effects were consistent in the 90% and 45% subpopulations of sperm. In both subpopulations, sildenafil also caused a significant increase in the proportion of acrosome reacted sperm - 22.1% compared with 11.8% in the control group of the good quality fraction (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Telematic tools are very important for our lives in the present era and moreover this idea is made more evident if we analyse young people behaviours. However, it seems that the possibilities that these tools allow subjects from a professional point of view, beyond the purely playful aspects, are still not fully exploited both by subjects, neither by educational institutions where they learn. Our work studies the uses of social media in the context of university students. In order to this we have designed a research based on quantitative methodology with a survey. We have applied a questionnaire to students in the University of Murcia. The questionnaire was answered by 487 students in the first half of 2014. The survey results confirm our hypothesis that social networks are part of the basic and habitual tools of communication between the youth of our university and eminently used for leisure purposes, and that the tools used for more academic activities are those allowing greater control of privacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computer-assisted topology predictions are widely used to build low-resolution structural models of integral membrane proteins (IMPs). Experimental validation of these models by traditional methods is labor intensive and requires modifications that might alter the IMP native conformation. This work employs oxidative labeling coupled with mass spectrometry (MS) as a validation tool for computer-generated topology models. ·OH exposure introduces oxidative modifications in solvent-accessible regions, whereas buried segments (e.g., transmembrane helices) are non-oxidizable. The Escherichia coli protein WaaL (O-antigen ligase) is predicted to have 12 transmembrane helices and a large extramembrane domain (Pérez et al., Mol. Microbiol. 2008, 70, 1424). Tryptic digestion and LC-MS/MS were used to map the oxidative labeling behavior of WaaL. Met and Cys exhibit high intrinsic reactivities with ·OH, making them sensitive probes for solvent accessibility assays. Overall, the oxidation pattern of these residues is consistent with the originally proposed WaaL topology. One residue (M151), however, undergoes partial oxidation despite being predicted to reside within a transmembrane helix. Using an improved computer algorithm, a slightly modified topology model was generated that places M151 closer to the membrane interface. On the basis of the labeling data, it is concluded that the refined model more accurately reflects the actual topology of WaaL. We propose that the combination of oxidative labeling and MS represents a useful strategy for assessing the accuracy of IMP topology predictions, supplementing data obtained in traditional biochemical assays. In the future, it might be possible to incorporate oxidative labeling data directly as constraints in topology prediction algorithms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Popular approaches in human tissue-based biomarker discovery include tissue microarrays (TMAs) and DNA Microarrays (DMAs) for protein and gene expression profiling respectively. The data generated by these analytic platforms, together with associated image, clinical and pathological data currently reside on widely different information platforms, making searching and cross-platform analysis difficult. Consequently, there is a strong need to develop a single coherent database capable of correlating all available data types.

Method: This study presents TMAX, a database system to facilitate biomarker discovery tasks. TMAX organises a variety of biomarker discovery-related data into the database. Both TMA and DMA experimental data are integrated in TMAX and connected through common DNA/protein biomarkers. Patient clinical data (including tissue pathological data), computer assisted tissue image and associated analytic data are also included in TMAX to enable the truly high throughput processing of ultra-large digital slides for both TMAs and whole slide tissue digital slides. A comprehensive web front-end was built with embedded XML parser software and predefined SQL queries to enable rapid data exchange in the form of standard XML files.

Results & Conclusion: TMAX represents one of the first attempts to integrate TMA data with public gene expression experiment data. Experiments suggest that TMAX is robust in managing large quantities of data from different sources (clinical, TMA, DMA and image analysis). Its web front-end is user friendly, easy to use, and most importantly allows the rapid and easy data exchange of biomarker discovery related data. In conclusion, TMAX is a robust biomarker discovery data repository and research tool, which opens up the opportunities for biomarker discovery and further integromics research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The self-reported use of natural health products (NHPs) (herbal products and vitamin and mineral supplements) has increased over the past decade in Canada. Because the elderly population might have comorbidities and concurrently administered medications, there is a need to explore the perceptions and behaviors associated with NHPs in this age group. Objective: The goal of this study was to assess the use of NHPs in a cohort of older Canadian residents and the characteristics, perceptions, and behaviors associated with NHP use. Methods: Survey participants aged =60 years were randomly selected from telephone listings in the area of greater Hamilton, Ontario, Canada. Data were collected using a standardized computer-assisted telephone interview system. Self-reported data covering 7 domains were collected: (1) demographics; (2) self-reported 12-month NHP use; (3) reasons for NHP use; (4) self-reported 12-month prescription medication use; (5) expenditures on NHPs; (6) patient-reported adverse events and drug-NHP interactions; and (7) perceptions of physicians' attitudes regarding NHPs. Descriptive statistics were used to compare the characteristics of NHP users with those of nonusers and to assess the characteristics of NHP users across these 7 domains. Multivariate regression analysis was conducted to determine the demographic variables that might be associated with NHP user status. Results: Of 2528 persons identified as age =60 years, 1206 (48%) completed the telephone interview. Six hundred sixteen of these respondents (51%) reported the use of =1 NHP during the previous 12 months. On the initial univariate analysis, younger age and higher income were significantly associated with reporting NHP use (mean age, users vs nonusers, 71.1 vs 72.7 years, respectively; 95% CI, 1.02-1.06; P <0.001; income more than Can $26,000 was 28% and 22% in users and nonusers, respectively; P = 0.028). One hundred seventy of 616 users (28%) used an NHP to treat the same condition for which they were concurrently receiving a prescription medication, and 43 (25%) had not informed their physicians about their NHP use. Patients' characteristics such as sex, education, smoking status, and self-reported health status did not differ significantly between users and nonusers. In individuals who regularly spent money to purchase NHPs (n = 394), the mean cost was $20.38/mo. NHP expenditure was not significantly associated with age, sex, or income. Conclusion: Based on these findings, a substantial proportion of those Ontarians aged =60 years reported NHP use, and there is a need for greater communication with physicians to avoid potential drug-NHP interactions. © 2009 Excerpta Medica Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite several decades of decline, cardiovascular diseases are still the most common causes of death in Western societies. Sedentary living and high fat diets contribute to the prevalence of cardiovascular diseases. This paper analyses the trade-offs between lifestyle choices defined in terms of diet, physical activity, cost, and risk of cardiovascular disease that a representative sample of the population of Northern Ireland aged 40-65 are willing to make. Using computer assisted personal interviews, we survey 493 individuals at their homes using a Discrete Choice Experiment (DCE) questionnaire administered between February and July 2011 in Northern Ireland. Unlike most DCE studies for valuing public health programs, this questionnaire uses a tailored exercise, based on the individuals’ baseline choices. A “fat screener” module in the questionnaire links personal cardiovascular disease risk to each specific choice set in terms of dietary constituents. Individuals are informed about their real status quo risk of a fatal cardiovascular event, based on an initial set of health questions. Thus, actual risks, real diet and exercise choices are the elements that constitute the choice task. Our results show that our respondents are willing to pay for reducing mortality risk and, more importantly, are willing to change physical exercise and dietary behaviours. In particular, we find that to improve their lifestyles, overweight and obese people would be more likely to do more physical activity than to change their diets. Therefore, public policies aimed to target obesity and its related illnesses in Northern Ireland should invest public money in promoting physical activity rather than healthier diets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The modern stereologic method of vertical sections was applied to the retina as a means of generating unbiased estimates of three-dimensional structure. The method is illustrated with real data on the volume and surface area of the capillary basement membrane from the central retina of the rat. Novel methods of estimating the volume of retina sampled and of creating accurate vertical sections are described. The advantages of using stereologic methods to generate quantitative information on the three-dimensional structure of the retina are discussed and compared to those of previous quantitative methods that provide data on two-dimensional structure only.