881 resultados para Computed Tomography (CT)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nanomedicine has attracted increasing attention in recent years, because it offers great promise to provide personalized diagnostics and therapy with improved treatment efficacy and specificity. In this study, we developed a gold nanostar (GNS) probe for multi-modality theranostics including surface-enhanced Raman scattering (SERS) detection, x-ray computed tomography (CT), two-photon luminescence (TPL) imaging, and photothermal therapy (PTT). We performed radiolabeling, as well as CT and optical imaging, to investigate the GNS probe's biodistribution and intratumoral uptake at both macroscopic and microscopic scales. We also characterized the performance of the GNS nanoprobe for in vitro photothermal heating and in vivo photothermal ablation of primary sarcomas in mice. The results showed that 30-nm GNS have higher tumor uptake, as well as deeper penetration into tumor interstitial space compared to 60-nm GNS. In addition, we found that a higher injection dose of GNS can increase the percentage of tumor uptake. We also demonstrated the GNS probe's superior photothermal conversion efficiency with a highly concentrated heating effect due to a tip-enhanced plasmonic effect. In vivo photothermal therapy with a near-infrared (NIR) laser under the maximum permissible exposure (MPE) led to ablation of aggressive tumors containing GNS, but had no effect in the absence of GNS. This multifunctional GNS probe has the potential to be used for in vivo biosensing, preoperative CT imaging, intraoperative detection with optical methods (SERS and TPL), as well as image-guided photothermal therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives This study aims to (1) discuss rare nasopharyngeal masses originating from embryologic remnants of the clivus, and (2) discuss the embryology of the clivus and understand its importance in the diagnosis and treatment of these masses. Design and Participants This is a case series of three patients. We discuss the clinical and imaging characteristics of infrasellar craniopharyngioma, intranasal extraosseous chordoma, and canalis basilaris medianus. Results Case 1: A 16-year-old male patient with a history of craniopharyngioma resection, who presented with nasal obstruction. A nasopharyngeal cystic mass was noted to be communicating with a patent craniopharyngeal canal. Histology revealed adamantinomatous craniopharyngioma. Case 2: A 43-year-old male patient who presented with nasal obstruction and headache. Computed tomography (CT) and magnetic resonance imaging revealed an enhancing polypoid mass in the posterior nasal cavity abutting the clivus. Histopathology revealed chondroid chordoma. Case 3: A 4-year-old female patient with a recurrent nasopharyngeal polyp. CT cisternogram showed that this mass may have risen from a bony defect of the middle clivus suggestive of canalis basilaris medianus. Conclusions Understanding the embryology of the clivus is crucial when considering the differential diagnosis of a nasopharyngeal mass. Identification of characteristic findings on imaging is critical in the diagnosis and treatment of these lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI), Computed Tomography (CT), Positron Emission Tomography (PET), bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To describe the clinical implementation of dynamic multileaf collimation (DMLC). Custom compensated four-field treatments of carcinoma of the bladder have been used as a simple test site for the introduction of intensity modulated radiotherapy.MATERIALS AND METHODS: Compensating intensity modulations are calculated from computed tomography (CT) data, accounting for scattered, as well as primary radiation. Modulations are converted to multileaf collimator (MLC) leaf and jaw settings for dynamic delivery on a linear accelerator. A full dose calculation is carried out, accounting for dynamic leaf and jaw motion and transmission through these components. Before treatment, a test run of the delivery is performed and an absolute dose measurement made in a water or solid water phantom. Treatments are verified by in vivo diode measurements and real-time electronic portal imaging. RESULTS: Seven patients have been treated using DMLC. The technique improves dose homogeneity within the target volume, reducing high dose areas and compensating for loss of scatter at the beam edge. A typical total treatment time is 20 min. CONCLUSIONS: Compensated bladder treatments have proven an effective test site for DMLC in an extremely busy clinic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and purpose: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation.Methods: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage.Results: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5+/-5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4+/-3.5% and normal tissue over-coverage of 25.4+/-4.2%.Conclusions: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RATIONALE: In bronchiectasis there is a need for improved markers of lung function to determine disease severity and response to therapy.

OBJECTIVES: To assess whether the lung clearance index is a repeatable and more sensitive indicator of computed tomography (CT) scan abnormalities than spirometry in bronchiectasis.

METHODS: Thirty patients with stable bronchiectasis were recruited and lung clearance index, spirometry, and health-related quality of life measures were assessed on two occasions, 2 weeks apart when stable (study 1). A separate group of 60 patients with stable bronchiectasis was studied on a single visit with the same measurements and a CT scan (study 2).

MEASUREMENTS AND MAIN RESULTS: In study 1, the intervisit intraclass correlation coefficient for the lung clearance index was 0.94 (95% confidence interval, 0.89 to 0.97; P < 0.001). In study 2, the mean age was 62 (10) years, FEV1 76.5% predicted (18.9), lung clearance index 9.1 (2.0), and total CT score 14.1 (10.2)%. The lung clearance index was abnormal in 53 of 60 patients (88%) and FEV1 was abnormal in 37 of 60 patients (62%). FEV1 negatively correlated with the lung clearance index (r = -0.51, P < 0.0001). Across CT scores, there was a relationship with the lung clearance index, with little evidence of an effect of FEV1. There were no significant associations between the lung clearance index or FEV1 and health-related quality of life.

CONCLUSIONS: The lung clearance index is repeatable and a more sensitive measure than FEV1 in the detection of abnormalities demonstrated on CT scan. The lung clearance index has the potential to be a useful clinical and research tool in patients with bronchiectasis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

contribuindo para o aumento da gordura abdominal, e consequentes complicações metabólicas. O exercício físico permite quebrar este ciclo através da estimulação da lipólise e da utilização de ácidos gordos. Objetivo: Verificar os efeitos de um programa de exercícios no domicílio, em indivíduos com doença arterial coronária, na composição corporal, gordura abdominal, perfil lipídico, glicose, e nível de atividade física. Métodos: Estudo experimental composto por 20 indivíduos, aleatorizados grupo experimental (GE) e grupo de controlo (GC), ambos com 10, tendo o GE sido sujeito ao programa durante 8 semanas. Realizou-se uma avaliação inicial e final, através da bioimpedância, Tomografia Computorizada (TC) abdominal, perimetria, adipometria, análises sanguíneas e acelerómetro. Resultados: Numa análise intergrupal, verificouse uma diminuição da percentagem (%) de gordura total (GT) calculado pela adipometria (p<0.01), na prega supra-ilíaca (p=0.005), na prega abdominal horizontal (p=0.001) e vertical (p=0.003) no GE, e da % de tempo em atividades moderadas no GC (p=0.035). Após 8 semanas o GE diminuiu a %GT (p=0.008); a massa gorda (MG) (p=0.002); perímetro abaixo da última costela (p=0.037) e acima das cristas-ilíacas (p=0.021); %GT calculado (p=0.002); pregas supra-ilíaca (p=0.008), abdominal horizontal (p=0.002) e vertical (p=0.033); TC abdominal subcutâneo (p=0.031) e %de tempo em atividades vigorosas (p=0.031). O GC diminuiu a %GT (p=0.002) e MG (p=0.008); aumentou o perímetro ao nível dos grandes trocânteres (p=0.008), diminuiu o rácio cintura/anca (p=0.002), e a %de tempo em atividades moderadas (p=0.031) e vigorosas (p=0.008). Parece existir uma tendência no GE para diminuição do rácio cintura/anca, c-LDL, triglicerídeos e aumento do nível de atividade moderado. Conclusão: O programa de exercícios no domicílio demonstrou uma diminuição da gordura abdominal, alteração da composição corporal, e parece promover uma melhoria no perfil lipídico e no aumento do nível de atividade física moderado.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The trans-apical aortic valve implantation (TA-AVI) is an established technique for high-risk patients requiring aortic valve replacement. Traditionally, preoperative (computed tomography (CT) scan, coronary angiogram) and intra-operative imaging (fluoroscopy) for stent-valve positioning and implantation require contrast medium injections. To preserve the renal function in elderly patients suffering from chronic renal insufficiency, a fully echo-guided trans-catheter valve implantation seems to be a reasonable alternative. We report the first successful TA-AVI procedure performed solely under trans-oesophageal echocardiogram control, in the absence of contrast medium injections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To investigate current practices and timing of neurological prognostication in comatose cardiac arrest patients. METHODS: An anonymous questionnaire was distributed to the 8000 members of the European Society of Intensive Care Medicine during September and October 2012. The survey had 27 questions divided into three categories: background data, clinical data, decision-making and consequences. RESULTS: A total of 1025 respondents (13%) answered the survey with complete forms in more than 90%. Twenty per cent of respondents practiced outside of Europe. Overall, 22% answered that they had national recommendations, with the highest percentage in the Netherlands (>80%). Eighty-nine per cent used induced hypothermia (32-34 °C) for comatose cardiac arrest patients, while 11% did not. Twenty per cent had separate prognostication protocols for hypothermia patients. Seventy-nine per cent recognized that neurological examination alone is not enough to predict outcome and a similar number (76%) used additional methods. Intermittent electroencephalography (EEG), brain computed tomography (CT) scan and evoked potentials (EP) were considered most useful. Poor prognosis was defined as cerebral performance category (CPC) 3-5 (58%) or CPC 4-5 (39%) or other (3%). When prognosis was considered poor, 73% would actively withdraw intensive care while 20% would not and 7% were uncertain. CONCLUSION: National recommendations for neurological prognostication after cardiac arrest are uncommon and only one physician out of five uses a separate protocol for hypothermia treated patients. A neurological examination alone was considered insufficient to predict outcome in comatose patients and most respondents advocated a multimodal approach: EEG, brain CT and EP were considered most useful. Uncertainty regarding neurological prognostication and decisions on level of care was substantial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PRINCIPLES: To assess the efficiency and complication rates of vaso-occlusion of pulmonary arteriovenous malformations (PAVMs) in Rendu-Osler-Weber disease (hereditary haemorrhagic telangectasia; HHT). METHODS: Seventy-two patients were investigated in our institution for HHT between March 2000 and November 2011. Sixteen presented PAVMs (22.2%), and 11 (68.8%) were treated with vaso-occlusion for a total of 18 procedures. Procedures included coils, plugs and combined approaches. Immediate success and recurrence rate, complication were recorded, as well as persistent and new PAVMs during clinical and computed tomography (CT) follow-up. RESULTS: Eighteen procedures were performed and a total of 37 PAVMs were treated, 19 with coils, 16 with plugs and 2 with combined treatment. Mean CT follow-up time was 41 months (1‒164). No major complication was observed. One distal translocation was treated during the same intervention. Two PAVMs persisted after treatment (5.7%), both treated by means of plug embolisation. One new PAVM was observed during follow-up CT. PAVMs with an afferent artery of less than 3mm or asymptomatic PAVMs were not treated. CONCLUSION: Recent studies have demonstrated that vaso-occlusion has become the gold standard treatment for PAVM. This study is in accordance with previous results and shows a minimal complication rate and little recurrence, whether by coils, plugs, or combined treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

While the overall incidence of myocardial infarction (MI) has been decreasing since 2000 [1], there is an increasing number of younger patients presenting with MI [2]. Few studies have focused on MI in very young patients, aged 35 years or less, as they only account for a minority of all patients with myocardial infarction [3]. According to the age category, MI differs in presentation, treatment and outcome, as illustrated in table 1. Echocardiography is considered mandatory according to scientific guidelines in the management and diagnosis of MI [4,5,6]. However, new imaging techniques such as cardiac magnetic resonance (CMR) and computed tomography (CT) are increasingly performed and enable further refinement of the diagnosis of MI. These techniques allow, in particular, precise location and quantification of MI. In this case, MI was located to the septum, which is an unusual presentation of MI. The incidence of pulmonary embolism (PE) has also increased in young patients over the past years [7]. Since symptoms and signs of PE may be non-specific, establishing its diagnosis remains a challenge [8]. Therefore, PE is one of the most frequently missed diagnosis in clinical medicine. Because of the widespread use of CT and its improved visualization of pulmonary arteries, PE may be discovered incidentally [9]. In the absence of a congenital disorder, multiple and/or simultaneous disease presentation is uncommon in the young. We report the rare case of a 35 year old male with isolated septal MI and simultaneous PE. The diagnosis of this rare clinical entity was only possible by means of newer imaging techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’athérosclérose est une maladie qui cause, par l’accumulation de plaques lipidiques, le durcissement de la paroi des artères et le rétrécissement de la lumière. Ces lésions sont généralement localisées sur les segments artériels coronariens, carotidiens, aortiques, rénaux, digestifs et périphériques. En ce qui concerne l’atteinte périphérique, celle des membres inférieurs est particulièrement fréquente. En effet, la sévérité de ces lésions artérielles est souvent évaluée par le degré d’une sténose (réduction >50 % du diamètre de la lumière) en angiographie, imagerie par résonnance magnétique (IRM), tomodensitométrie ou échographie. Cependant, pour planifier une intervention chirurgicale, une représentation géométrique artérielle 3D est notamment préférable. Les méthodes d’imagerie par coupe (IRM et tomodensitométrie) sont très performantes pour générer une imagerie tridimensionnelle de bonne qualité mais leurs utilisations sont dispendieuses et invasives pour les patients. L’échographie 3D peut constituer une avenue très prometteuse en imagerie pour la localisation et la quantification des sténoses. Cette modalité d’imagerie offre des avantages distincts tels la commodité, des coûts peu élevés pour un diagnostic non invasif (sans irradiation ni agent de contraste néphrotoxique) et aussi l’option d’analyse en Doppler pour quantifier le flux sanguin. Étant donné que les robots médicaux ont déjà été utilisés avec succès en chirurgie et en orthopédie, notre équipe a conçu un nouveau système robotique d’échographie 3D pour détecter et quantifier les sténoses des membres inférieurs. Avec cette nouvelle technologie, un radiologue fait l’apprentissage manuel au robot d’un balayage échographique du vaisseau concerné. Par la suite, le robot répète à très haute précision la trajectoire apprise, contrôle simultanément le processus d’acquisition d’images échographiques à un pas d’échantillonnage constant et conserve de façon sécuritaire la force appliquée par la sonde sur la peau du patient. Par conséquent, la reconstruction d’une géométrie artérielle 3D des membres inférieurs à partir de ce système pourrait permettre une localisation et une quantification des sténoses à très grande fiabilité. L’objectif de ce projet de recherche consistait donc à valider et optimiser ce système robotisé d’imagerie échographique 3D. La fiabilité d’une géométrie reconstruite en 3D à partir d’un système référentiel robotique dépend beaucoup de la précision du positionnement et de la procédure de calibration. De ce fait, la précision pour le positionnement du bras robotique fut évaluée à travers son espace de travail avec un fantôme spécialement conçu pour simuler la configuration des artères des membres inférieurs (article 1 - chapitre 3). De plus, un fantôme de fils croisés en forme de Z a été conçu pour assurer une calibration précise du système robotique (article 2 - chapitre 4). Ces méthodes optimales ont été utilisées pour valider le système pour l’application clinique et trouver la transformation qui convertit les coordonnées de l’image échographique 2D dans le référentiel cartésien du bras robotisé. À partir de ces résultats, tout objet balayé par le système robotique peut être caractérisé pour une reconstruction 3D adéquate. Des fantômes vasculaires compatibles avec plusieurs modalités d’imagerie ont été utilisés pour simuler différentes représentations artérielles des membres inférieurs (article 2 - chapitre 4, article 3 - chapitre 5). La validation des géométries reconstruites a été effectuée à l`aide d`analyses comparatives. La précision pour localiser et quantifier les sténoses avec ce système robotisé d’imagerie échographique 3D a aussi été déterminée. Ces évaluations ont été réalisées in vivo pour percevoir le potentiel de l’utilisation d’un tel système en clinique (article 3- chapitre 5).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En radiothérapie, la tomodensitométrie (CT) fournit l’information anatomique du patient utile au calcul de dose durant la planification de traitement. Afin de considérer la composition hétérogène des tissus, des techniques de calcul telles que la méthode Monte Carlo sont nécessaires pour calculer la dose de manière exacte. L’importation des images CT dans un tel calcul exige que chaque voxel exprimé en unité Hounsfield (HU) soit converti en une valeur physique telle que la densité électronique (ED). Cette conversion est habituellement effectuée à l’aide d’une courbe d’étalonnage HU-ED. Une anomalie ou artefact qui apparaît dans une image CT avant l’étalonnage est susceptible d’assigner un mauvais tissu à un voxel. Ces erreurs peuvent causer une perte cruciale de fiabilité du calcul de dose. Ce travail vise à attribuer une valeur exacte aux voxels d’images CT afin d’assurer la fiabilité des calculs de dose durant la planification de traitement en radiothérapie. Pour y parvenir, une étude est réalisée sur les artefacts qui sont reproduits par simulation Monte Carlo. Pour réduire le temps de calcul, les simulations sont parallélisées et transposées sur un superordinateur. Une étude de sensibilité des nombres HU en présence d’artefacts est ensuite réalisée par une analyse statistique des histogrammes. À l’origine de nombreux artefacts, le durcissement de faisceau est étudié davantage. Une revue sur l’état de l’art en matière de correction du durcissement de faisceau est présentée suivi d’une démonstration explicite d’une correction empirique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'un des principaux défis de l'interprétation radiographique réside dans la compréhension de l’anatomie radiographique, laquelle est intrinsèquement liée à la disposition tridimensionnelle des structures anatomiques et à l’impact du positionnement du tube radiogène vis-à-vis de ces structures lors de l'acquisition de l'image. Traditionnellement, des radiographies obtenues selon des projections standard sont employées pour enseigner l'anatomie radiographique en médecine vétérinaire. La tomodensitométrie − ou communément appelée CT (Computed Tomography) − partage plusieurs des caractéristiques de la radiographie en ce qui a trait à la génération des images. À l’aide d'un plug-in spécialement développé (ORS Visual ©), la matrice contenant les images CT est déformée pour reproduire les effets géométriques propres au positionnement du tube et du détecteur vis-à-vis du patient radiographié, tout particulièrement les effets de magnification et de distorsion. Afin d'évaluer le rendu des images simulées, différentes régions corporelles ont été imagées au CT chez deux chiens, un chat et un cheval, avant d'être radiographiées suivant des protocoles d'examens standards. Pour valider le potentiel éducatif des simulations, dix radiologistes certifiés ont comparé à l'aveugle neuf séries d'images radiographiques simulées aux séries radiographiques standard. Plusieurs critères ont été évalués, soient le grade de visualisation des marqueurs anatomiques, le réalisme et la qualité radiographique des images, le positionnement du patient et le potentiel éducatif de celles-ci pour différents niveaux de formation vétérinaire. Les résultats généraux indiquent que les images radiographiques simulées à partir de ce modèle sont suffisamment représentatives de la réalité pour être employées dans l’enseignement de l’anatomie radiographique en médecine vétérinaire.