983 resultados para Compact subsets
Resumo:
A simple method for the design of ultra-wideband antennas in planar format is presented. This method is demonstrated for a high-dielectric-constant substrate material, which allows for a considerable antenna size reduction. Simulations are performed using Ansoft's High-Frequency Structure Simulator (HFSS) for antennas assuming Du-Pont951 (epsilon(r) = 7.8) and RT6010LM (epsilon(r) = 10.2) substrates. For the 1-mm-thick DuPont951, the designed antenna with 22 X 28 nun dimensions features a 10-dB return-loss band width front 2.7 GHz to more than 15 GHz. For the 0.64-mm-thick RT6010LM a 20 X 26 nun antenna exhibits a 10-dB return loss bandwidth from 3.1 to 15 GHz. Both antennas feature nearly omnidirectional properties across the whole 10-dB return-loss bandwidth. The validity of the presented UWB antenna design strategy is confirmed by measurements performed on a prototype developed on RT6010LM substrate. (c) 2006 Wiley Periodicals, Inc.
Resumo:
In this paper, a novel design procedure for designing a compact UWB antipodal Vivaldi antenna is presented. The antenna operates over the UWB frequency, band from 3.1 to more than 10.6 GHz. Its measured far-field radiation is directive and its peak gain is 10.2 dBi in the specified band. The antenna pulse response shows negligible distortion, indicating that it can be useful in a precision ranging and imaging instrumentation. (c) 2006 Wiley Periodicals, Inc.
Resumo:
In this paper we demonstrate that it is possible to gradually improve the performance of support vector machine (SVM) classifiers by using a genetic algorithm to select a sequence of training subsets from the available data. Performance improvement is possible because the SVM solution generally lies some distance away from the Bayes optimal in the space of learning parameters. We illustrate performance improvements on a number of benchmark data sets.
Resumo:
One of critical challenges in automatic recognition of TV commercials is to generate a unique, robust and compact signature. Uniqueness indicates the ability to identify the similarity among the commercial video clips which may have slight content variation. Robustness means the ability to match commercial video clips containing the same content but probably with different digitalization/encoding, some noise data, and/or transmission and recording distortion. Efficiency is about the capability of effectively matching commercial video sequences with a low computation cost and storage overhead. In this paper, we present a binary signature based method, which meets all the three criteria above, by combining the techniques of ordinal and color measurements. Experimental results on a real large commercial video database show that our novel approach delivers a significantly better performance comparing to the existing methods.
Resumo:
A hybrid waveguide Bragg grating in optical fiber was fabricated and characterized, showing thermal responsivity of 211pm/°C. Proposed being used in fiber sensor, it demonstrates enhanced resolution by 20x and 2x for temperature and strain.
Resumo:
A hybrid waveguide Bragg grating in optical fiber was fabricated and characterized, showing thermal responsivity of 211pm/°C. Proposed being used in fiber sensor, it demonstrates enhanced resolution by 20x and 2x for temperature and strain.
Resumo:
Non-uniform B-spline dictionaries on a compact interval are discussed in the context of sparse signal representation. For each given partition, dictionaries of B-spline functions for the corresponding spline space are built up by dividing the partition into subpartitions and joining together the bases for the concomitant subspaces. The resulting slightly redundant dictionaries are composed of B-spline functions of broader support than those corresponding to the B-spline basis for the identical space. Such dictionaries are meant to assist in the construction of adaptive sparse signal representation through a combination of stepwise optimal greedy techniques.
Resumo:
We present a compact, portable and low cost generic interrogation strain sensor system using a fibre Bragg grating configured in transmission mode with a vertical-cavity surface-emitting laser (VCSEL) light source and a GaAs photodetector embedded in a polymer skin. The photocurrent value is read and stored by a microcontroller. In addition, the photocurrent data is sent via Bluetooth to a computer or tablet device that can present the live data in a real time graph. With a matched grating and VCSEL, the system is able to automatically scan and lock the VCSEL to the most sensitive edge of the grating. Commercially available VCSEL and photodetector chips are thinned down to 20 µm and integrated in an ultra-thin flexible optical foil using several thin film deposition steps. A dedicated micro mirror plug is fabricated to couple the driving optoelectronics to the fibre sensors. The resulting optoelectronic package can be embedded in a thin, planar sensing sheet and the host material for this sheet is a flexible and stretchable polymer. The result is a fully embedded fibre sensing system - a photonic skin. Further investigations are currently being carried out to determine the stability and robustness of the embedded optoelectronic components. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Resumo:
A novel approach to optical subcarrier multiplexing with compact spectrum is demonstrated using a 42.6 Gbit/s AM-PSK payload and 2.5 Gbit/s NRZ label. In this implementation, the payload introduces a 4.8 dB penalty on the label receiver sensitivity, and the label causes <1 dB penalty on the payload receiver sensitivity.
Resumo:
A free space quantum key distribution system has been demonstrated. Consideration has been given to factors such as field of view and spectral width, to cut down the deleterious effect from background light levels. Suitable optical sources such as lasers and RCLEDs have been investigated as well as optimal wavelength choices, always with a view to building a compact and robust system. The implementation of background reduction measures resulted in a system capable of operating in daylight conditions. An autonomous system was left running and generating shared key material continuously for over 7 days. © 2009 Published by Elsevier B.V..
Resumo:
Objective: Previous studies have suggested that somatoform disorders (SFD) might be associated with changes in the function of the central and autonomic nervous systems. The aim of this study was to examine the possible immunological differences between SFD and healthy controls. Methods: Twenty-four patients with SFD and 13 healthy individuals completed the psychological questionnaires to assess symptom reporting [Symptom Checklist-90 Revised (SCL-90-R)] and to diagnose for SFD [Screening for Somatoform Symptoms scale (SOMS-scale)]. Participants also provided a blood sample taken in the morning, which was analysed with an automated cell counter to determine the number of leucocytes per μl and with flow cytometry to determine lymphocyte subsets. Results: With the exception of a higher T4/T8 ratio in the patient group, which was mainly because of lower CD8 counts, there were no significant differences in the absolute number of lymphocytes (subsets) between patients with SFD and healthy subjects. A positive correlation between B-lymphocyte subsets (CD19+CD22+, CD19+CD5+, CD19+CD3-) to all scales of the SCL-90-R, except somatisation, were found in SFD. Additionally, a positive correlation was found in SFD between CD14+CD16+ monocytes and somatisation (0.573) on the SCL-90-R scale. Conclusion: These data indicate that patients with SFD have an enhanced humoral immunity as shown by increased B-cell numbers and furthermore an elevated T4/T8 ratio because of lower CD8 suppressor cells. Further studies will be required to determine whether these alterations in lymphocyte subsets are directly involved in the pathophysiology of SFD. © 2007 Blackwell Munksgaard.
Resumo:
A continuous multi-step synthesis of 1,2-diphenylethane was performed sequentially in a structured compact reactor. This process involved a Heck C-C coupling reaction followed by the addition of hydrogen to perform reduction of the intermediate obtained in the first step. Both of the reactions were catalysed by microspherical carbon-supported Pd catalysts. Due to the integration of the micro-heat exchanger, the static mixer and the mesoscale packed-bed reaction channel, the compact reactor was proven to be an intensified tool for promoting the reactions. In comparison with the batch reactor, this flow process in the compact reactor was more efficient as: (i) the reaction time was significantly reduced (ca. 7 min versus several hours), (ii) no additional ligands were used and (iii) the reaction was run at lower operational pressure and temperature. Pd leached in the Heck reaction step was shown to be effectively recovered in the following hydrogenation reaction section and the catalytic activity of the system can be mostly retained by reverse flow operation. © 2009 Elsevier Inc. All rights reserved.