937 resultados para Ciclismo indoor


Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 mu m(2)/cm(3). The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To evaluate the association between recurrent wheezing and atopy, the Asthma Predictive Index, exposure to risk factors, and total serum IgE levels as potential factors to predict recurrent wheezing. METHODS A case-control study with infants aged 6-24 months treated at a specialized outpatient clinic from November 2011 to March 2013. Evaluations included sensitivity to inhalant and food antigens, positive Asthma Predictive Index, and other risk factors for recurrent wheezing (smoking during pregnancy, presence of indoor smoke, viral infections, and total serum IgE levels). RESULTS We evaluated 113 children: 65 infants with recurrent wheezing (63.0% male) with a mean age of 14.8 (SD = 5.2) months and 48 healthy infants (44.0% male) with a mean age of 15.2 (SD = 5.1) months. In the multiple analysis model, antigen sensitivity (OR = 12.45; 95%CI 1.28–19.11), positive Asthma Predictive Index (OR = 5.57; 95%CI 2.23–7.96), and exposure to environmental smoke (OR = 2.63; 95%CI 1.09–6.30) remained as risk factors for wheezing. Eosinophilia ≥ 4.0% e total IgE ≥ 100 UI/mL were more prevalent in the wheezing group, but failed to remain in the model. Smoking during pregnancy was identified in a small number of mothers, and secondhand smoke at home was higher in the control group. CONCLUSIONS Presence of atopy, positive Asthma Predictive Index and exposure to environmental smoke are associated to recurrent wheezing. Identifying these factors enables the adoption of preventive measures, especially for children susceptible to persistent wheezing and future asthma onset.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) mu m have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to assess the levels of airborne ultrafine particles emitted in welding processes (tungsten inert gas [TIG], metal active gas [MAG] of carbon steel, and friction stir welding [FSW] of aluminum) in terms of deposited area in pulmonary alveolar tract using a nanoparticle surface area monitor (NSAM) analyzer. The obtained results showed the dependence of process parameters on emitted ultrafine particles and demonstrated the presence of ultrafine particles compared to background levels. Data indicated that the process that resulted in the lowest levels of alveolar deposited surface area (ADSA) was FSW, followed by TIG and MAG. However, all tested processes resulted in significant concentrations of ultrafine particles being deposited in humans lungs of exposed workers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to contribute to the assessment of exposure levels of ultrafine particles (UFP) in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung-deposited alveolar surface area (resulting from exposure to UFP) in a major avenue leading to the town centre during late Spring, as well as in indoor buildings facing it. This study revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels could be directly related with the fluxes of automobile traffic. During a typical week, UFP alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and United States. The measured values allowed the determination of the number of UFP per cm(3), which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32-63%) outdoor, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 mu m2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Ramo Tecnologias de Protecção Ambiental

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Em consequência da elevada permanência das pessoas em espaços interiores de edifícios, surge actualmente uma maior preocupação com o conforto térmico e qualidade do ar no seu interior. Apesar da grande evolução tecnológica dos sistemas de conservação de energia térmica e controle da qualidade do ar interior (QAI) na construção, os edifícios existentes acabam por não acompanhar essa evolução, apresentando um comportamento térmico e higrométrico que por vezes podem comprometer quer o conforto, quer a saúde e actividades dos seus utilizadores. Nos estabelecimentos de ensino, o comportamento termo-higrométrico assume um papel importante face à permanência diária de um grande número de crianças e jovens no seu interior. Com este estudo pretende-se caracterizar a qualidade do ambiente no interior de oito escolas, através de uma análise aos principais parâmetros de natureza higrotérmica de oito salas de aulas, tais como: a temperatura (ambiente e superficial), a humidade relativa (do ambiente e da superfície da envolvente exterior opaca), bem como o nível de escoamento do ar interior. Neste trabalho são apresentados os resultados das medições efectuadas em oito salas de aula que permitiram a comparação de características termo-higrométricas entre as respectivas escolas. É ainda apresentada a estimativa do nível de conforto térmico face às condições ambientais registadas, bem como a análise do risco de ocorrência de condensações interiores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objectivo principal deste trabalho é a realização de uma auditoria, à qualidade do ar interior (QAI), a um edifício de serviços – COCIGA, SA, tendo como base o Regulamento dos Sistemas Energéticos de Climatização dos Edifícios (RSECE). A auditoria QAI implica a medição de vários parâmetros físicos, químicos, microbiológicos e também a inspecção aos componentes do sistema de climatização com a finalidade de averiguar o seu estado de limpeza e manutenção. Assim, foram seleccionados 3 espaços, para a realização de amostragens designados por Comercial - Produtos, AVAC e Mezaninne das oficinas, nos quais foi efectuada a medição de diversos parâmetros, de acordo com as imposições do RSECE, utilizando medidores portáteis ou recorrendo a métodos analíticos. Relativamente aos parâmetros físicos, registaram-se valores de temperatura, para os três espaços estudados, entre os 21 e os 24 ºC e valores médios de humidade relativa de cerca de 50 %. Outro parâmetro medido, e de grande importância para garantir o conforto dos ocupantes, foi a velocidade do ar nos postos de trabalho. De acordo com o RSECE este valor não deve ser superior a 0,2 m/s, o que se verificou em todos os pontos medidos. O último parâmetro físico medido foi a concentração de partículas (PM10) tendo-se obtido valores de cerca de 23 μg/m3ar, valor bastante inferior ao máximo permitido pelo RSECE (150 μg/m3ar). Também no que diz respeito aos parâmetros químicos, ou seja, CO2, CO, formaldeído e ozono, não se verificaram valores superiores aos regulamentares. No caso do CO2, o valor máximo encontrado, nestes três espaços, foi de 745 ppm na Mezaninne das Oficinas e para o CO, na zona AVAC com uma concentração de 0,73 ppm. A medição do formaldeído registou valores perto dos 45 μg/m3ar e o ozono apenas foi detectado, em concentração muito reduzida, na zona Comercial – Produtos. Por fim, as concentrações de bactérias e fungos, de acordo com o RSECE, não devem ultrapassar as 500 UFC/m3ar (parâmetros microbiológicos). Em qualquer dos espaços, os valores medidos foram inferiores ao máximo legal, não ultrapassando as 50 UFC/m3ar. Da avaliação do projecto AVAC, e através da medição dos caudais de insuflação/ extracção em cada zona, concluiu-se que os seus valores não estão de acordo com os valores do projecto inicial que poderá ser imputada a uma insuficiência no funcionamento do sistema detectada na altura das medições. No que diz respeito ao estado de limpeza do sistema AVAC, apenas foi possível inspeccionar as unidades de tratamento de ar, tendo-se constatado que se encontram em boas condições. Ou seja, do ponto de vista do RSECE, e referindo-nos apenas à vertente da Qualidade do Ar Interior, o edifício em causa, cumpre todos os limites impostos para as concentrações de poluentes mas, apresenta algumas deficiências no que respeita aos caudais de ar novo insuflados em cada espaço.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Buildings account for 40% of total energy consumption in the European Union. The reduction of energy consumption in the buildings sector constitute an important measure needed to reduce the Union's energy dependency and greenhouse gas emissions. The Portuguese legislation incorporate this principles in order to regulate the energy performance of buildings. This energy performance should be accompanied by good conditions for the occupants of the buildings. According to EN 15251 (2007) the four factors that affect the occupant comfort in the buildings are: Indoor Air Quality (IAQ), thermal comfort, acoustics and lighting. Ventilation directly affects all except the lighting, so it is crucial to understand the performance of it. The ventilation efficiency concept therefore earn significance, because it is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the spaces. The two indicators most internationally accepted are the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE). Nowadays with the developed of the Computational Fluid Dynamics (CFD) the behaviour of ventilation can be more easily predicted. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by the MicroFlo module of the IES-VE software for this two indicators. The main conclusions from this work were: that the values of the numerical simulations are in agreement with experimental measurements; the value of the CRE is more dependent of the position of the contamination source, that the strategy used for the air diffusion; the ACE indicator is more appropriate for quantifying the quality of the air diffusion; the solutions to be adopted, to maximize the ventilation efficiency should be, the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em engenharia electrotécnica e de computadores - Área de Especialização de Sistemas Autónomos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Projeto submetido à Escola Superior de Teatro e Cinema para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Desenvolvimento de Projecto Cinematográfico - especialização em Realização e Dramaturgia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores