862 resultados para Aqueous Extraction
Resumo:
The small Rho-family GTPase Cdc42 is critical for cell polarization and polarizes spontaneously in absence of upstream spatial cues. Spontaneous polarization is thought to require dynamic Cdc42 recycling through Guanine nucleotide Dissociation Inhibitor (GDI)-mediated membrane extraction and vesicle trafficking. Here, we describe a functional fluorescent Cdc42 allele in fission yeast, which demonstrates Cdc42 dynamics and polarization independent of these pathways. Furthermore, an engineered Cdc42 allele targeted to the membrane independently of these recycling pathways by an amphipathic helix is viable and polarizes spontaneously to multiple sites in fission and budding yeasts. We show that Cdc42 is highly mobile at the membrane and accumulates at sites of activity, where it displays slower mobility. By contrast, a near-immobile transmembrane domain-containing Cdc42 allele supports viability and polarized activity, but does not accumulate at sites of activity. We propose that Cdc42 activation, enhanced by positive feedback, leads to its local accumulation by capture of fast-diffusing inactive molecules.
Resumo:
Työssä tutkittiin typpihapon soveltuvuutta nikkelin takaisinuuttoon. Tarkoituksena oli selvittää, millä typpihapon konsentraatioilla orgaaninen faasi, joka koostuu Versatic 10 uuttoreagenssista ja alifaattisesta laimentimesta, alkaa nitrautua tai hapettua ja mitkä ovat mahdolliset sivureaktiot. Lisäksi tutkittiin rikkihapon ja eräiden orgaanisten aineiden kontaminaation vaikutusta uuttoliuokseen. Kirjallisuusosassa kartoitetaan mahdollisten nitrautumisreaktioiden mekanismit, sekä kuvataan laimentimen, uuttoreagenssin ja mahdollisten reaktiotuotteiden ominaisuuksia, sekä niiden mahdollisessa muodostumisessa syntyviä riskejä. Orgaanisen faasin kestotesteissä tutkittavia muuttujia olivat typpi- ja rikkihapon konsentraatio, sekoitusaika, lämpötila, avoin tai suljettu astia sekä vieraiden aineiden kontaminaatio. Kontaminaatiota aiheuttavien orgaanisten materiaalien funktionaaliset ryhmät olivat hydroksi-, karbonyyli- ja amiiniryhmät, joiden lisäksi tutkittiin syklisen yhdisteen kontaminaatiota. Analyyseissä käytettiin FT-IR- spektroskopiaa, jolla tutkittiin reagenssin funktionaalisen ryhmän reaktioita ja uusien ryhmien muodostumista, sekä seurattiin selkeytyksessä erottumattomien typpiyhdisteiden määrää ja laatua orgaanisessa faasissa. Uuttofaasin koostumuksen muutosta seurattiin myös mittaamalla leimahduspisteen muutosta.
Resumo:
Introduction: Third molar extraction is the most frequent procedure in oral surgery. The present study evaluates the indication of third molar extraction as established by the primary care dentist (PCD) and the oral surgeon, and compares the justification for extraction with the principal reason for patient consultation. Patients and method: A descriptive study was made of 319 patients subjected to surgical removal of a third molar in the context of the Master of Oral Surgery and Implantology (Barcelona University Dental School, Barcelona, Spain) between July 2004 and March 2005. The following parameters were evaluated: sex, age, molar, type of impaction, position according to the classifications of Pell and Gregory and of Winter, and the reasons justifying extraction. Results: The lower third molars were the most commonly extracted molars (73.7%). A total of 69.6% of the teeth were covered by soft tissues only. Fifty-six percent of the lower molars corresponded to Pell and Gregory Class IIB, while 42.1% were in the vertical position. The most common reason for patient reference to our Service of Oral Surgery on the part of the PCD was prophylactic removal (51.0% versus 46.1% in the case of the oral surgeon). Discussion and conclusions. Our results show prophylaxis to be the principal indication of third molar extraction, followed by orthodontic reasons. Regarding third molars with associated clinical symptoms or signs, infectious disease-including pericoronitis- was the pathology most often observed by the oral surgeon, followed by caries. This order of frequency was seen to invert in the case of third molars referred for extraction by the PCD. A vertical position predominated among the third molars with associated pathology
Resumo:
Social interactions are a very important component in people"s lives. Social network analysis has become a common technique used to model and quantify the properties of social interactions. In this paper, we propose an integrated framework to explore the characteristics of a social network extracted from multimodal dyadic interactions. For our study, we used a set of videos belonging to New York Times" Blogging Heads opinion blog. The Social Network is represented as an oriented graph, whose directed links are determined by the Influence Model. The links" weights are a measure of the"influence" a person has over the other. The states of the Influence Model encode automatically extracted audio/visual features from our videos using state-of-the art algorithms. Our results are reported in terms of accuracy of audio/visual data fusion for speaker segmentation and centrality measures used to characterize the extracted social network.
Resumo:
Background: To evaluate the safety of immediate sequential bilateral cataract extraction (ISBCE) with respect to indications, visual outcomes, complications, benefits and disadvantages. Methods: This is a retrospective review of all ISBCEs performed at Kantonsspital Winterthur, Switzerland, between April 2000 and September 2013. The case notes of 500 eyes of 250 patients were reviewed. Of these 500 eyes, 472 (94.4%) had a straight forward phacoemulsification with posterior chamber intraocular lens implantation; 21 (4.2%) had a planned extracapsular cataract extraction; 4 (0.8%) had an intracapsular cataract extraction and 3 (0.6%) had a combined phacoemulsification with trabeculectomy. Results: Over 66% of eyes achieved improved visual acuity (at least 3 Snellen lines) following ISBCE. Median preoperative best corrected visual acuity (BCVA) was 0.5 LogMAR; the interquartile range was [0.4, 1] LogMAR. At one week control the median BCVA was 0.3 LogMAR, IQR [0.1, 0.5] LogMAR. At one month the median BCVA was 0.15 LogMAR, IQR [0.05, 0.3] (p < 0.01). There were no sight-threatening intraoperative or postoperative complications observed. Conclusions: ISBCE is an effective and safe option with high degree of patient satisfaction. The relative benefits of ISBCE should be balanced against the theoretically enhanced risks.
Resumo:
In forensic investigation of firearm-related cases, determination of the residual amount of volatile compounds remaining inside a cartridge could be useful in estimating the time since its discharge. Published approaches are based on following the decrease of selected target compounds as a function of time by using solid phase micro-extraction (SPME). Naphthalene, as well as an unidentified decomposition product of nitrocellulose (referred to as "TEA2"), are usually employed for this purpose. However, reliability can be brought into question given their high volatility and the low reproducibility of their extracted quantities. In order to identify alternatives and therefore develop improved dating methods, an extensive study on the composition and variability of volatile residues in nine different types of cartridges was carried out. Analysis was performed using headspace sorptive extraction (HSSE), which is a more exhaustive technique compared to SPME. 166 compounds were identified (several of which for the first time), and it was observed that the final compositional characteristics of each residue were strongly dependent on its source. Variability of single identified compounds within and between different types of cartridge, as well as their evolution over time, was also studied. Many explosion products containing up to 4 aromatic rings were found to be globally present in high proportions amongst residues. 27 of them (excluding naphthalene) also presented detectable decreases during the first 24 h. Therefore, they could be used as complementary target analytes in future dating methods.
Resumo:
ABSTRACT Functional genomic analyses require intact RNA; however, Passiflora edulis leaves are rich in secondary metabolites that interfere with RNA extraction primarily by promoting oxidative processes and by precipitating with nucleic acids. This study aimed to analyse three RNA extraction methods, Concert™ Plant RNA Reagent (Invitrogen, Carlsbad, CA, USA), TRIzol® Reagent (Invitrogen) and TRIzol® Reagent (Invitrogen)/ice -commercial products specifically designed to extract RNA, and to determine which method is the most effective for extracting RNA from the leaves of passion fruit plants. In contrast to the RNA extracted using the other 2 methods, the RNA extracted using TRIzol® Reagent (Invitrogen) did not have acceptable A260/A280 and A260/A230 ratios and did not have ideal concentrations. Agarose gel electrophoresis showed a strong DNA band for all of the Concert™ method extractions but not for the TRIzol® and TRIzol®/ice methods. The TRIzol® method resulted in smears during electrophoresis. Due to its low levels of DNA contamination, ideal A260/A280 and A260/A230 ratios and superior sample integrity, RNA from the TRIzol®/ice method was used for reverse transcription-polymerase chain reaction (RT-PCR), and the resulting amplicons were highly similar. We conclude that TRIzol®/ice is the preferred method for RNA extraction for P. edulis leaves.
Resumo:
In this study we used market settlement prices of European call options on stock index futures to extract implied probability distribution function (PDF). The method used produces a PDF of returns of an underlying asset at expiration date from implied volatility smile. With this method, the assumption of lognormal distribution (Black-Scholes model) is tested. The market view of the asset price dynamics can then be used for various purposes (hedging, speculation). We used the so called smoothing approach for implied PDF extraction presented by Shimko (1993). In our analysis we obtained implied volatility smiles from index futures markets (S&P 500 and DAX indices) and standardized them. The method introduced by Breeden and Litzenberger (1978) was then used on PDF extraction. The results show significant deviations from the assumption of lognormal returns for S&P500 options while DAX options mostly fit the lognormal distribution. A deviant subjective view of PDF can be used to form a strategy as discussed in the last section.
Resumo:
In fetal brain MRI, most of the high-resolution reconstruction algorithms rely on brain segmentation as a preprocessing step. Manual brain segmentation is however highly time-consuming and therefore not a realistic solution. In this work, we assess on a large dataset the performance of Multiple Atlas Fusion (MAF) strategies to automatically address this problem. Firstly, we show that MAF significantly increase the accuracy of brain segmentation as regards single-atlas strategy. Secondly, we show that MAF compares favorably with the most recent approach (Dice above 0.90). Finally, we show that MAF could in turn provide an enhancement in terms of reconstruction quality.
Resumo:
Combining headspace (HS) sampling with a needle-trap device (NTD) to determine priority volatile organic compounds (VOCs) in water samples results in improved sensitivity and efficiency when compared to conventional static HS sampling. A 22 gauge stainless steel, 51-mm needle packed with Tenax TA and Carboxen 1000 particles is used as the NTD. Three different HS-NTD sampling methodologies are evaluated and all give limits of detection for the target VOCs in the ng L−1 range. Active (purge-and-trap) HS-NTD sampling is found to give the best sensitivity but requires exhaustive control of the sampling conditions. The use of the NTD to collect the headspace gas sample results in a combined adsorption/desorption mechanism. The testing of different temperatures for the HS thermostating reveals a greater desorption effect when the sample is allowed to diffuse, whether passively or actively, through the sorbent particles. The limits of detection obtained in the simplest sampling methodology, static HS-NTD (5 mL aqueous sample in 20 mL HS vials, thermostating at 50 °C for 30 min with agitation), are sufficiently low as to permit its application to the analysis of 18 priority VOCs in natural and waste waters. In all cases compounds were detected below regulated levels