996 resultados para ANTIGEN LEVEL
Resumo:
We evaluated the immunogenicity of three recombinant hepatitis B vaccines, one Brazilian (Butang, Instituto Butantan) and two Korean vaccines (Euvax-B, LG Chemical Ltd. and Hepavax-Gene, Greencross Vaccine Corp.), administered intramuscularly to students aged 17 to 19 years in three 10-µg doses (corresponding to half the amount of antigen routinely used for adult vaccination) at intervals of one month between the first and second dose, and of four months between the second and third dose. A total of 316 students non-reactive for any serological marker of hepatitis B virus infection were vaccinated: 77 (24.4%) with the Butang vaccine, 71 (22.5%) with Euvax-B, 85 (26.9%) with Hepavax-Gene and, for comparison, 83 (26.2%) with Engerix-B (GlaxoSmithKline), whose efficacy in young adults at the dose used here has been confirmed in previous studies. Similar seroconversion rates (anti-HBs > 10 mIU/mL about one month after application of the third dose) were obtained for the Butang, Euvax-B, Hepavax-Gene and Engerix-B vaccines (96.2%, 98.6%, 96.5% and 97.6%, respectively). The frequency of good responders (anti-HBs > 100 mIU/mL) was also similar among students receiving the four vaccines (85.8%, 91.6%, 89.4% and 89.2%, respectively). The geometric mean titers (GMT) of anti-HBs about one month after the third dose obtained with these vaccines were 727.78 ± 6.46 mIU/mL, 2009.09 ± 7.16 mIU/mL, 1729.82 ± 8.85 mIU/mL and 2070.14 ± 11.69 mIU/mL, respectively. The GMT of anti-HBs induced by the Euvax-B and Engerix-B vaccines were higher than those obtained with the Butang vaccine (p < 0.05); this difference was not significant when comparing the other vaccines two-by-two. No spontaneous adverse effects attributable to the application of any dose of the four vaccines were reported.
Resumo:
Previous experiences have demonstrated the same ABO system and P system antigens in A. lumbricoides extracts and in their hosts. The aim was to show the behavior of an A. lumbricoides extract from an O Group patient against monoclonal antibodies of different specificities. Agglutination Inhibition Tests were carried out facing the extract against monoclonal antibodies (anti A 2.23; anti B 2.54; anti B 2.62; anti AB 2.39 and anti H 2.72) in optimal concentrations. Suspensions of O Group fresh red cells were used as revealing system. The extract only inhibited the agglutination of anti H 2.72 with O erythrocytes. The semiquantitative Agglutination Inhibition Test of the extract was made against two series of anti H 2.72 dilutions by using O Group fresh red cells as revealing system. A difference of five dilutions between the titers of both series has been observed and the presence of H Antigen in the extract has been significantly confirmed. The fact that the extract did not inhibit the agglutination against anti A, anti B and anti AB has corroborated our previous observations about absence of A and B epitopes in A. lumbricoides extracts from O Group patients. The results of the preceding studies and this experience have demonstrated the membrane glycoconjugated importance in A. lumbricoides. They could be involved in molecular mimicry for this parasite.
Resumo:
Dissertação para obtenção do Grau de Mestre em Energias Renováveis – Conversão Eléctrica e Utilização Sustentáveis
Resumo:
Trabalho de projecto apresentado para o cumprimento dos requisitos necessários à obtenção do grau de mestre em Didática do Inglês
Resumo:
Trabalho de Projeto apresentado para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Teaching English as a Second / Foreign Language
Resumo:
In the traditional paradigm, the large power plants supply the reactive power required at a transmission level and the capacitors and transformer tap changer were also used at a distribution level. However, in a near future will be necessary to schedule both active and reactive power at a distribution level, due to the high number of resources connected in distribution levels. This paper proposes a new multi-objective methodology to deal with the optimal resource scheduling considering the distributed generation, electric vehicles and capacitor banks for the joint active and reactive power scheduling. The proposed methodology considers the minimization of the cost (economic perspective) of all distributed resources, and the minimization of the voltage magnitude difference (technical perspective) in all buses. The Pareto front is determined and a fuzzy-based mechanism is applied to present the best compromise solution. The proposed methodology has been tested in the 33-bus distribution network. The case study shows the results of three different scenarios for the economic, technical, and multi-objective perspectives, and the results demonstrated the importance of incorporating the reactive scheduling in the distribution network using the multi-objective perspective to obtain the best compromise solution for the economic and technical perspectives.
Resumo:
This paper addresses the challenging task of computing multiple roots of a system of nonlinear equations. A repulsion algorithm that invokes the Nelder-Mead (N-M) local search method and uses a penalty-type merit function based on the error function, known as 'erf', is presented. In the N-M algorithm context, different strategies are proposed to enhance the quality of the solutions and improve the overall efficiency. The main goal of this paper is to use a two-level factorial design of experiments to analyze the statistical significance of the observed differences in selected performance criteria produced when testing different strategies in the N-M based repulsion algorithm. The main goal of this paper is to use a two-level factorial design of experiments to analyze the statistical significance of the observed differences in selected performance criteria produced when testing different strategies in the N-M based repulsion algorithm.
Resumo:
Toxoplasma gondii causes severe fetal disease during acute infection in pregnant women, thus demanding early diagnosis for effective treatment and fetus preservation. Fetal tests are inefficient and risky, and diagnosis is based on maternal IgM serology, which had weak screening ability due to increased sensitivity, with alternative IgG avidity tests. Here, we performed ELISA and avidity assays using a recombinant T. gondii antigen, rROP2, in samples from 160 pregnant women screened from a large public hospital who were referred due to positive IgM assays. IgG serology and avidity assays were compared using whole T. gondii extract or rROP2. ELISA IgG detection with rROP2 showed good agreement with assays performed with T. gondii extract, but rROP2 IgG avidity assays were unrelated to whole extract antigen IgG avidity, regardless of the chaotrope used. These data show that avidity maturation is specific to individual antigen prevalence and immune response during infection. ELISA rROP2 IgG assays may be an alternative serological test for the diagnosis of toxoplasmosis during pregnancy, although our data do not support their use in avidity assays.
Resumo:
The main serological marker for the diagnosis of recent toxoplasmosis is the specific IgM antibody, along with IgG antibodies of low avidity. However, in some patients these antibodies may persist long after the acute/recent phase, contributing to misdiagnosis in suspected cases of toxoplasmosis. In the present study, the diagnostic efficiency of ELISA was evaluated, with the use of peptides derived from T. gondii ESA antigens, named SAG-1, GRA-1 and GRA-7. In the assay referred to, we studied each of these peptides individually, as well as in four different combinations, as Multiple Antigen Peptides (MAP), aiming to establish a reliable profile for the acute/recent toxoplasmosis with only one patient serum sample. The diagnostic performance of the assay using MAP1, with the combination of SAG-1, GRA-1 and GRA-7 peptides, demonstrated better discrimination of the acute/recent phase from non acute/recent phase of toxoplasmosis. Our results show that IgM antibodies to MAP1 may be useful as a serological marker, enhancing the diagnostic efficiency of the assay for acute/recent phase of toxoplasmosis.
Ecosystem applied to the dengue control at local level: an approach based in the social reproduction
Resumo:
The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.
Resumo:
Adenovirus (AdV) respiratory infections are usually described as being associated with high mortality rates. Laboratory diagnosis is essential for the establishment of the appropriate therapy, and for guiding the implementation of preventive measures in order to prevent the spread of the infection. Aiming to analyze the sensitivity and specificity of the laboratorial diagnosis methods available, we compared antigen detection by indirect immunofluorescence assay (IF), and a specific nested polymerase chain reaction (PCR), to detect AdV in respiratory samples collected from patients admitted to hospital with acute respiratory disease. Positive samples were inoculated into a cell culture to confirm the results. We analyzed 381 samples from the nasopharyngeal aspirates collected during the year 2008; of these, 2.6% tested were positive for adenovirus through IF and 10% through PCR; positive isolation was obtained in 40% and 26% of these cases, respectively. Most infected patients were children under six months of age, and despite of the fact that a significant number of patients required intensive care, the mortality rate was low (5%). In conclusion, molecular methods were found to be useful for rapid diagnosis of adenovirus infections with higher sensitivity than antigen detection; their introduction permitted a significant increase in diagnoses of adenovirus infections.
Resumo:
The present work evaluated the diagnostic accuracy of detection of Dengue NS1 antigen employing two NS1 assays, an immunochromatographic assay and ELISA, in the diagnostic routine of Public Health laboratories. The results obtained with NS1 assay were compared with virus isolation and, in a subpopulation of cases, they were compared with the IgM-ELISA results obtained with convalescent samples. A total of 2,321 sera samples were analyzed by one of two NS1 techniques from March to October 2009. The samples were divided into five groups: groups I, II and III included samples tested by NS1 and virus isolation, and groups IV and V included patients with a first sample tested by NS1 and a second sample tested by IgM-ELISA. Sensitivity, specificity, positive and negative predictive values, Kappa Index and Kappa Concordance were calculated. The results showed that NS1 testing in groups I, II and III had high sensitivity (98.0%, 99.5% and 99.3%), and predictive values and Kappa index between 0.9 - 1.0. Groups IV and V only had Kappa Concordance calculated, since the samples were analyzed according to the presence of NS1 antigen or IgM antibody. Concordance of 92.1% was observed when comparing the results of NS1-negative samples with IgM-ELISA. Based on the findings, it is possible to suggest that the tests for NS1 detection may be important tools for monitoring the introduction and spread of Dengue serotypes.
Resumo:
In this study, we report on the safety and skin delayed-type hypersensitivity (DTH), responses of the Leishmania donovani whole cell sonicate antigen delivered in conjunction with alum-BCG (AlBCG), Montanide ISA 720 (MISA) or Monophosphoryl lipid A (MPLA) in groups of vervet monkeys. Following three intradermal injections of the inoculums on days 0, 28 and 42, safety and DTH responses were assessed. Preliminary tumor necrosis factor alpha (TNF-α) and interferon gamma (IFN-γ) levels were also measured and these were compared with DTH. Only those animals immunized with alum-BCG reacted adversely to the inoculum by producing ulcerative erythematous skin indurations. Non-parametric analysis of variance followed by a post-test showed significantly higher DTH responses in the MISA+Ag group compared with other immunized groups (p < 0.001). The MPLA+Ag group indicated significantly lower DTH responses to the sonicate antigen compared with the AlBCG+Ag group. There was a significant correlation between the DTH and cytokine responses (p < 0.0001). Based on this study we conclude that Leishmania donovani sonicate antigen containing MISA 720 is safe and is associated with a strong DTH reaction following immunization.