986 resultados para 2nd Regiment of the Lincoln Militia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the fraction f(+) of right-handed W bosons produced in top quark decays, based on a candidate sample of tt events in the l + jets and dilepton decay channels corresponding to an integrated luminosity of 370 pb(-1) collected by the D0 detector at the Fermilab Tevatron pp Collider at root s = 1.96 TeV. We reconstruct the decay angle theta* for each lepton. By comparing the cos theta* distribution from the data with that for the expected background and signal for various values of f(+) (where we assume that the fraction of longitudinally-polarized W bosons has the standard model value of 0.70), we find f(+) = 0.056 +/- 0.080 (stat) +/- 0.057 (syst) (f(+) < 0.23 at 95% C. L.), consistent with the standard model prediction of f(+) = 3.6 X 10(-4).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a study of the decay B-s(0)->(DsDs(*))-D-(*) using a data sample corresponding to 1.3 fb(-1) of integrated luminosity collected by the D0 experiment in 2002-2006 during run II of the Fermilab Tevatron collider. One D-s((*)) meson was partially reconstructed in the decay D-s ->phi mu nu, and the other D-s((*)) meson was identified using the decay D-s ->phi pi where no attempt was made to distinguish D-s and D-s(*) states. For the branching fraction Br(B-s(0)->(DsDs(*))-D-(*)) we obtain a 90% C.L. range [0.002,0.080] and central value 0.039(-0.017)(+0.019)(stat)(-0.015)(+0.016)(syst). This was subsequently used to make the most precise estimate of the width difference Delta Gamma(CP)(s) in the B-s(0)-(B)over bar(s)(0) system: Delta Gamma(CP)(s)/Gamma(s)=0.079(-0.035)(+0.038)(stat)(-0.030)(+0.031)(syst).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the top quark mass with the matrix element method in the lepton+jets final state. As the energy scale for calorimeter jets represents the dominant source of systematic uncertainty, the matrix element likelihood is extended by an additional parameter, which is defined as a global multiplicative factor applied to the standard energy scale. The top quark mass is obtained from a fit that yields the combined statistical and systematic jet energy scale uncertainty. Using a data set of 0.4 fb(-1) taken with the D0 experiment at Run II of the Fermilab Tevatron Collider, the mass of the top quark is measured using topological information to be: m(top)(center dot+jets)(topo)=169.2(-7.4)(+5.0)(stat+JES)(-1.4)(+1.5)(syst) GeV, and when information about identified b jets is included: m(top)(center dot+jets)(b-tag)=170.3(-4.5)(+4.1)(stat+ JES)(-1.8)(+1.2)(syst) GeV. The measurements yield a jet energy scale consistent with the reference scale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A measurement of the top quark mass using events with one charged lepton, missing transverse energy, and jets in the final state, collected by the D0 detector from p (p) over bar collisions at root s=1.96 TeV at the Fermilab Tevatron collider, is presented. A constrained fit is used to fully reconstruct the kinematics of the events. For every event a top quark mass likelihood is calculated taking into account all possible jet assignments and the probability that an event is signal or background. Lifetime-based identification of b jets is employed to enhance the separation between t (t) over bar signal and background from other physics processes and to improve the assignment of the observed jets to the quarks in the t (1) over bar hypothesis. We extract a multiplicative jet energy scale (JES) factor in situ, greatly reducing the systematic effect related to the jet energy measurement. In a data sample with an integrated luminosity of 425 pb(-1), we observe 230 candidate events, with an estimated background of 123 events, and measure m(t)=173.7 +/- 4.4(stat+JES)(-2.0)(+2.1)(syst) GeV. This result represents the first application of the ideogram technique to the measurement of the top quark mass in lepton+jets events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the first direct observation of the strange b baryon Xi(-)(b)(Xi) over bar (+)(b)). We reconstruct the decay Xi(-)(b)-->J/psi Xi(-), with J/psi-->mu(+)mu(-), and Xi(-)-->Lambda pi(-)-->p pi(-)pi(-) in p (p) over bar collisions at root s = 1.96 TeV. Using 1.3 fb(-1) of data collected by the D0 detector, we observe 15.2 +/- 4.4(stat)(-0.4)(+1.9)(syst) Xi(-)(b) candidates at a mass of 5.774 +/- 0.011(stat) +/- 0.015(syst) GeV. The significance of the observed signal is 5.5 sigma, equivalent to a probability of 3.3 x 10(-8) of it arising from a background fluctuation. Normalizing to the decay Lambda(b)-->J/psi Lambda, we measure the relative rate sigma(Xi(-)(b))xB(Xi(-)(b)-->J/psi Xi)/ sigma(Lambda(b))xB(Lambda(b)-->J/psi Lambda) = 0.28 +/- 0.09(stat)(-0.08)(+0.09)(syst).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A measurement of the top quark pair production cross section in proton antiproton collisions at an interaction energy of root s=1.96 TeV is presented. This analysis uses 405 +/- 25 pb(-1) of data collected with the D0 detector at the Fermilab Tevatron Collider. Fully hadronic t (t) over bar decays with final states of six or more jets are separated from the multijet background using secondary vertex tagging and a neural network. The t (t) over bar cross section is measured as sigma(t (t) over bar)=4.5(-1.9)(+2.0)(stat)(-1.1)(+1.4)(syst)+/- 0.3(lumi) pb for a top quark mass of m(t)=175 GeV/c(2).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a measurement of the Lambda(0)(b) lifetime using a sample corresponding to 1.3 fb(-1) of data collected by the D0 experiment in 2002-2006 during run II of the Fermilab Tevatron collider. The Lambda(0)(b) baryon is reconstructed via the decay Lambda(0)(b)->mu(nu) over bar Lambda X-+(c). Using 4437 +/- 329 signal candidates, we measure the Lambda(0)(b) lifetime to be tau(Lambda(0)(b))=1.290(-0.110)(+0.119)(stat)(-0.091)(+0.087)(syst) ps, which is among the most precise measurements in semileptonic Lambda(0)(b) decays. This result is in good agreement with the world average value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the top quark mass in the dilepton channel based on approximately 370 pb(-1) of data collected by the DO experiment during Run R of the Fermilab Tevatron collider. We employ two different methods to extract the top quark mass. We show that both methods yield consistent results using ensemble tests of events generated with the DO Monte Carlo simulation. We combine the results from the two methods to obtain a top quark mass m(t) = 178.1 +/- 8.2 GeV. The statistical uncertainty is 6.7 GeV and the systematic uncertainty is 4.8 GeV. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have measured the Lambda(b) lifetime using the exclusive decay Lambda(b)-> J/psi Lambda, based on 1.2 fb(-1) of data collected with the D0 detector during 2002-2006. From 171 reconstructed Lambda(b) decays, where the J/psi and Lambda are identified via the decays J/psi ->mu(+)mu(-) and Lambda -> p pi, we measured the Lambda(b) lifetime to be tau(Lambda(b))=1.218(-0.115)(+0.130)(stat)+/- 0.042(syst) ps. We also measured the B-0 lifetime in the decay B-0 -> J/psi(mu(+)mu(-))K-S(0)(pi(+)pi(-)) to be tau(B-0)=1.501(-0.074)(+0.078)(stat)+/- 0.050(syst) ps, yielding a lifetime ratio of tau(Lambda(b))/tau(B-0)=0.811(-0.087)(+0.096)(stat)+/- 0.034(syst).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the shape of the boson rapidity distribution for p (p) over bar -> Z/gamma(*)-> e(+)e(-)+X events at a center-of-mass energy of 1.96 TeV. The measurement is made for events with electron-positron mass 71 < M-ee < 111 GeV and uses 0.4 fb(-1) of data collected at the Fermilab Tevatron collider with the D0 detector. This measurement significantly reduces the uncertainties on the rapidity distribution in the forward region compared with previous measurements. Predictions of next-to-next-to-leading order (NNLO) QCD are found to agree well with the data over the full rapidity range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the observation of the X(3872) in the J/psipi(+)pi(-) channel, with J/psi decaying to mu(+)mu(-), in p (p) over bar collisions at roots=1.96 TeV. Using approximately 230 pb(-1) of data collected with the Run II D0 detector, we observe 522+/-100 X(3872) candidates. The mass difference between the X(3872) state and the J/psi is measured to be 774.9+/-3.1(stat)+/-3.0(syst) MeV/c(2). We have investigated the production and decay characteristics of the X(3872) and find them to be similar to those of the psi(2S) state.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present measurements of the Lambda(b)(0) lifetime in the exclusive decay channel Lambda(b)(0)-> J/psi Lambda(0), with J/psi ->mu(+)mu(-) and Lambda(0)-> p pi(-), the B-0 lifetime in the decay B-0-> J/psi K-S(0) with J/psi ->mu(+)mu(-) and K-S(0)->pi(+)pi(-), and the ratio of these lifetimes. The analysis is based on approximately 250 pb(-1) of data recorded with the D0 detector in p (p) over bar collisions at root s = 1.96 TeV. The Lambda(b)(0) lifetime is determined to be tau(Lambda(b)(0))=1.22(-0.18)(+0.22)(stat)+/- 0.04(syst) ps, the B-0 lifetime tau(B-0)=1.40(-) (+0.11)(0.10)(stat)+/- 0.03(syst) ps, and the ratio tau(Lambda(b)(0))/tau(B-0)=0.87(-) (+0.17)(0.14)(stat)+/- 0.03(syst). In contrast with previous measurements using semileptonic decays, this is the first determination of the Lambda(b)(0) lifetime based on a fully reconstructed decay channel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using the data collected with the D0 detector at root s=1.96 TeV, for integrated luminosities of about 180 pb(-1), we have measured the ratio of inclusive cross sections for p(p) over bar -> Z+b jet to p(p) over bar -> Z+jet production. The inclusive Z+b-jet reaction is an important background to searches for the Higgs boson in associated ZH production at the Fermilab Tevatron collider. Our measurement is the first of its kind, and relies on the Z -> e(+)e(-) and Z ->mu(+)mu(-) modes. The combined measurement of the ratio yields 0.021 +/- 0.005 for hadronic jets with transverse momenta p(T)> 20 GeV/c and pseudorapidities vertical bar eta vertical bar < 2.5, consistent with next-to-leading-order predictions of the standard model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We measure the dimuon charge asymmetry A in p (p) over bar collisions at a center of mass energy root s=1960 GeV. The data was recorded with the D0 detector and corresponds to an integrated luminosity of approximately 1.0 fb(-1). Assuming that the asymmetry A is due to asymmetric B-0 <->(B) over bar (0) mixing and decay, we extract the CP-violation parameter of B-0 mixing and decay: ((epsilon B0))/(1+vertical bar epsilon B0 vertical bar 2)=(AB0)/(4)= -0.0023 +/- 0.0011(stat)+/- 0.0008(syst).A(B)(0) is the dimuon charge asymmetry from decays of B-0(B) over bar (0) pairs. The general case, with CP violation in both B-0 and B-s(0) systems, is also considered. Finally we obtain the forward-backward asymmetry that quantifies the tendency of mu(+) to go in the proton direction and mu(-) to go in the antiproton direction. The results are consistent with the standard model and constrain new physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a measurement of the t (t) over bar pair production cross section in p (p) over bar collisions at root s=1.96 TeV utilizing approximately 425 pb(-1) of data collected with the D0 detector. We consider decay channels containing two high p(T) charged leptons (either e or mu) from leptonic decays of both top-daughter W bosons. These were gathered using four sets of selection criteria, three of which required that a pair of fully identified leptons (i.e., e mu, ee, or mu mu) be found. The fourth approach imposed less restrictive criteria on one of the lepton candidates and required that at least one hadronic jet in each event be tagged as containing a b quark. For a top quark mass of 175 GeV, the measured cross section is 7.4 +/- 1.4(stat)+/- 1.0(syst) pb and for the current Tevatron average top quark mass of 170.9 GeV, the resulting value of the cross section is 7.8 +/- 1.8(stat+syst) pb.