Purpose: To evaluate the ocular refractive and biometric characteristics in patients with tilted disc syndrome (TDS). Methods: This case-control study comprised 41 eyes of 25 patients with established TDS and forty eyes of 20 age- and sex-matched healthy control subjects. All had a complete ocular examination including refraction and analysis using Fourier transformation, slit lamp biomicroscopy, pachymetry keratometry, and ocular biometry. Corneal topography examinations were performed in the syndrome group only. Results: There were no significant differences in spherical equivalent (p = 0.334) and total astigmatism (p= 0.246) between groups. However, mean best spectacular corrected visual acuity was significantly worse in TDS patients (P < 0.001). The lenticular astigmatism was significantly greater in the syndrome group, while the corneal component was greater in the controls (p = 0.004 and p = 0.002, respectively). The measured biometric features were the same in both groups, except for the lens thickness, relative lens position, and lens-axial length factor which were greater in the TDS group (p = 0.002, p = 0.015, and p = 0.025, respectively). Conclusions: Clinically significant lenticular astigmatism, more oblique corneal astigmatism, and thicker lens were characteristic findings in patients with TDS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 60-year-old male experienced a marked unilateral myopic shift of 20 D following attempted removal of intravitreal heavy silicone oil (HSO) used in the treatment of inferior proliferative vitreous retinopathy following retinal detachment. Examination revealed HSO adherent to the corneal endothelium forming a convex interface with the aqueous, obscuring the entire pupil, which required surgical intervention to restore visual acuity. This case highlights the potential ocular complications associated with silicone oil migration into the anterior chamber, which include corneal endothelial decompensation and a significant increase in myopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose There have been only a limited number of studies examining the accommodative response that occurs when the two eyes are provided with disparate accommodative stimuli, and the results from these studies to date have been equivocal. In this study, we therefore aimed to examine the capacity of the visual system to aniso-accommodate by objectively measuring the interocular difference in the accommodation response between fellow dominant and non-dominant eyes under controlled monocular and binocular viewing conditions during short-term exposure to aniso-accommodative stimuli. Methods The accommodative response of each eye of sixteen young isometropic adults (mean age 22 ± 2 years) with normal binocular vision was measured using an open-field autorefractor during a range of testing conditions; monocularly (accommodative demands ranging from 1.32 to 4.55 D) and binocularly while altering the accommodation demand for each eye (aniso-accommodative stimuli ranging from 0.24 to 2.05 D). Results Under monocular viewing conditions, the dominant and non-dominant eyes displayed a highly symmetric accommodative response; mean interocular difference in spherical equivalent 0.01 ± 0.06 D (relative) and 0.22 ± 0.06 D (absolute) (p>0.05). During binocular viewing, the dominant eye displayed a greater accommodative response (0.11 ± 0.34 D relative and 0.24 ± 0.26 D absolute) irrespective of whether the demand of the dominant or non-dominant eye was altered (p = 0.01). Astigmatic power vectors J0 and J45 did not vary between eyes or with increasing accommodation demands under monocular or binocular viewing conditions (p>0.05). Conclusion The dominant and non-dominant eyes of young isometropic individuals display a similar consensual lag of accommodation under both monocular and binocular viewing conditions, with the dominant eye showing a small but significantly greater (by 0.12 to 0.25 D) accommodative response. Evidence of short-term aniso-accommodation in response to asymmetric accommodation demands was not observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To highlight the finding of occult areas of poor epithelial adhesion in the superior perilimbal cornea in a minority of patients with recalcitrant recurrent corneal erosion syndrome presenting with corneal erosion elsewhere on the corneal surface. Patient population 31 eyes of 31 consecutive patients with corneal erosion undergoing mechanical debridement of the epithelium prior to diamond burr keratectomy for recurrent corneal erosion. Methods Determine the location and incidence of poor epithelial adhesion distant from the initial erosion by use of mechanical debridement with a dry microsponge. Results During debridement, 8 of 31 eyes (25.8%) displayed a large arcuate area of occult dysfunction of adhesion in the superior perilimbal area. None of these patients showed recurrence over a mean of 18 month after diamond burr keratectomy (95% confidence interval 0-36.9%). Conclusion Mechanical debridement with a microsponge identified a significant minority of patients with poor adhesion in the superior perilimbal cornea away from the area of obvious erosion and increased the target area for diamond burr keratectomy. This two pronged approach allowed successful management of this group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The size and arrangement of stromal collagen fibrils (CFs) influence the optical properties of the cornea and hence its function. The spatial arrangement of the collagen is still questionable in relation to the diameter of collagen fibril. In the present study, we introduce a new parameter, edge-fibrillar distance (EFD) to measure how two collagen fibrils are spaced with respect to their closest edges and their spatial distribution through normalized standard deviation of EFD (NSDEFD) accessed through the application of two commercially available multipurpose solutions (MPS): ReNu and Hippia. The corneal buttons were soaked separately in ReNu and Hippia MPS for five hours, fixed overnight in 2.5% glutaraldehyde containing cuprolinic blue and processed for transmission electron microscopy. The electron micrographs were processed using ImageJ user-coded plugin. Statistical analysis was performed to compare the image processed equivalent diameter (ED), inter-fibrillar distance (IFD), and EFD of the CFs of treated versus normal corneas. The ReNu-soaked cornea resulted in partly degenerated epithelium with loose hemidesmosomes and Bowman’s collagen. In contrast, the epithelium of the cornea soaked in Hippia was degenerated or lost but showed closely packed Bowman’s collagen. Soaking the corneas in both MPS caused a statistically significant decrease in the anterior collagen fibril, ED and a significant change in IFD, and EFD than those of the untreated corneas (p < 0.05, for all comparisons). The introduction of EFD measurement in the study directly provided a sense of gap between periphery of the collagen bundles, their spatial distribution; and in combination with ED, they showed how the corneal collagen bundles are spaced in relation to their diameters. The spatial distribution parameter NSDEFD indicated that ReNu treated cornea fibrils were uniformly distributed spatially, followed by normal and Hippia. The EFD measurement with relatively lower standard deviation and NSDEFD, a characteristic of uniform CFs distribution, can be an additional parameter used in evaluating collagen organization and accessing the effects of various treatments on corneal health and transparency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background There is no legal requirement for Iranian military truck drivers to undergo regular visual checkups as compared to commercial truck drivers. Objectives This study aimed to evaluate the impact of drivers’ visual checkups by comparing the visual function of Iranian military and commercial truck drivers. Patients and Methods In this comparative cross-sectional study, two hundred military and 200 commercial truck drivers were recruited and their Visual Acuity (VA), Visual Field (VF), color vision and Contrast Sensitivity (CS) were assessed and compared using the Snellen chart, confrontation screening method, D15 test and Pelli-Robson letter chart, respectively. A questionnaire regarding driving exposure and history of motor-vehicle crashes (MVCs) was also filled by drivers. Results were analyzed using an independent samples t-test, one-way ANOVA (assessing difference in number of MVCs across different age groups), chi-square test and Pearson correlation at statistical significance level of P < 0.05. Results Mean age was 41.6 ± 9.2 for the military truck drivers and 43.4 ± 10.9 for commercial truck drivers (P > 0.05). No significant difference between military and commercial drivers was found in terms of driving experience, number of MVCs, binocular VA, frequency of color vision defects and CS scores. In contrast, the last ocular examination was significantly earlier in military drivers than commercial drivers (P < 0.001). In addition, 4% of military drivers did not meet the national standards to drive as opposed to 2% of commercial drivers. There was a significant but weak correlation between binocular VA and age (r = 0.175, P < 0.001). However, CS showed a significantly moderate correlation with age (r = -0.488, P < 0.001). Conclusions The absence of legal requirement for regular eye examination in military drivers caused the incompetent drivers to be missed in contrast to commercial drivers. The need for scientific revision of VA standard for Iranian drivers is also discussed. The CS measurement in visual checkups of older drivers deserves to be investigated more thoroughly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: At present there are no large scale nationally-representative studies from Sri Lanka on the prevalence and associations of Diabetic Retinopathy (DR). The present study aims to evaluate the prevalence and risk factors for DR in a community-based nationally-representative sample of adults with self-reported diabetes mellitus from Sri Lanka. Methods: A cross-sectional community-based national study among 5,000 adults (≥18 years) was conducted in Sri Lanka, using a multi-stage stratified cluster sampling technique. An interviewer-administered questionnaire was used to collect data. Ophthalmological evaluation of patients with ‘known’ diabetes (previously diagnosed at a government hospital or by a registered medical practitioner) was done using indirect ophthalmoscopy. A binary-logistic regression analysis was performed with ‘presence of DR’ as the dichotomous dependent variable and other independent covariates. Results: Crude prevalence of diabetes was 12.0%(n=536),of which 344 were patients with ‘known’ diabetes.Mean age was 56.4 ± 10.9 years and 37.3% were males. Prevalence of any degree of DR was 27.4% (Males-30.5%, Females-25.6%; p = 0.41). In patients with DR, majority had NPDR (93.4%), while 5.3% had maculopathy. Patients with DR had a significantly longer duration of diabetes than those without. In the binary-logistic regression analysis in all adults duration of diabetes (OR:1.07), current smoking (OR:1.67) and peripheral neuropathy (OR:1.72)all were significantly associated with DR. Conclusions: Nearly 1/3rd of Sri Lankan adults with self-reported diabetes are having retinopathy. DR was associated with diabetes duration, cigarette smoking and peripheral neuropathy. However, further prospective follow up studies are required to establish causality for identified risk factors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To characterize the changes occurring in choroidal thickness (ChT) across the posterior pole during accommodation using enhanced-depth imaging optical coherence tomography (OCT). Methods. Forty participants (mean age 21 ± 2 years) had measures of ChT and ocular biometry taken during accommodation to 0, 3, and 6 diopter (D) stimuli, with the Spectralis OCT and Lenstar biometer. A Badal optometer and cold mirror system was mounted on both instruments, allowing measurement collection while subjects viewed an external fixation target at varying accommodative demands. Results. The choroid exhibited significant thinning during accommodation to the 6 D stimulus in both subfoveal (mean change, −5 ± 7 μm) and parafoveal regions (P < 0.001). The magnitude of these changes varied by parafoveal meridian, with the largest changes seen in the temporal (−9 ± 12 μm) and inferotemporal (−8 ± 8 μm) meridians (P < 0.001). Axial length increased with accommodation (mean change, +5 ± 11 μm at 3 D, +14 ± 13 μm at 6 D), and these changes were weakly negatively associated with the choroidal changes (r2 = 0.114, P < 0.05). Conclusions. A small, but significant thinning of the choroid was observed at the 6 D accommodation demand, which was greatest in the temporal and inferotemporal parafoveal choroid, and increased with increasing eccentricity from the fovea. The regional variation in the parafoveal thinning corresponds to the distribution of the nonvascular smooth muscle within the uvea, which may implicate these cells as the potential mechanism by which the choroid thins during accommodation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To examine the association between glaucoma and motor vehicle collision (MVC) involvement among older drivers, including the role of visual field impairment that may underlie any association found. Design A retrospective population-based study Participants A sample of 2,000 licensed drivers aged 70 years and older who reside in north central Alabama. Methods At-fault MVC involvement for five years prior to enrollment was obtained from state records. Three aspects of visual function were measured: habitual binocular distance visual acuity, binocular contrast sensitivity and the binocular driving visual field constructed from combining the monocular visual fields of each eye. Poisson regression was used to calculate crude and adjusted rate ratios (RR) and 95% confidence intervals (CI). Main Outcomes Measures At-fault MVC involvement for five years prior to enrollment. Results Drivers with glaucoma (n = 206) had a 1.65 (95% confidence interval [CI] 1.20-2.28, p = 0.002) times higher MVC rate compared to those without glaucoma after adjusting for age, gender and mental status. Among those with glaucoma, drivers with severe visual field loss had higher MVC rates (RR = 2.11, 95% CI 1.09-4.09, p = 0.027), whereas no significant association was found among those with impaired visual acuity and contrast sensitivity. When the visual field was sub-divided into six regions (upper, lower, left, and right visual fields; horizontal and vertical meridians), we found that impairment in the left, upper or lower visual field was associated with higher MVC rates, and an impaired left visual field showed the highest RR (RR = 3.16, p = 0.001) compared to other regions. However, no significant association was found in deficits in the right side or along the horizontal or vertical meridian. Conclusions A population-based study suggests that older drivers with glaucoma are more likely to have a history of at-fault MVC involvement than those without glaucoma. Impairment in the driving visual field in drivers with glaucoma appears to have an independent association with at-fault MVC involvement, whereas visual acuity and contrast sensitivity impairments do not.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project provides a foundation for the use of silk membranes in a tissue engineered therapy for the treatment of devastating retinal diseases such as age-related macular degeneration. The three-dimensional tissue model described in this thesis has great potential for use in basic research of retinal pathologies, and the potential to be implemented into clinical approaches after appropriate refinement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose The post-illumination pupil response (PIPR) has been quantified using four metrics, but the spectral sensitivity of only one is known; here we determine the other three. To optimize the human PIPR measurement, we determine the protocol producing the largest PIPR, the duration of the PIPR, and the metric(s) with the lowest coefficient of variation. Methods The consensual pupil light reflex (PLR) was measured with a Maxwellian view pupillometer. - Experiment 1: Spectral sensitivity of four PIPR metrics [plateau, 6 s, area under curve (AUC) early and late recovery] was determined from a criterion PIPR to a 1s pulse and fitted with Vitamin A1 nomogram (λmax = 482nm). - Experiment 2: The PLR was measured as a function of three stimulus durations (1s, 10s, 30s), five irradiances spanning low to high melanopsin excitation levels (retinal irradiance: 9.8 to 14.8 log quanta.cm-2.s-1), and two wavelengths, one with high (465nm) and one with low (637nm) melanopsin excitation. Intra and inter-individual coefficients of variation (CV) were calculated. Results The melanopsin (opn4) photopigment nomogram adequately describes the spectral sensitivity of all four PIPR metrics. The PIPR amplitude was largest with 1s short wavelength pulses (≥ 12.8 log quanta.cm-2.s-1). The plateau and 6s PIPR showed the least intra and inter-individual CV (≤ 0.2). The maximum duration of the sustained PIPR was 83.0±48.0s (mean±SD) for 1s pulses and 180.1±106.2s for 30s pulses (465nm; 14.8 log quanta.cm-2.s-1). Conclusions All current PIPR metrics provide a direct measure of the intrinsic melanopsin photoresponse. To measure progressive changes in melanopsin function in disease, we recommend that the PIPR be measured using short duration pulses (e.g., ≤ 1s) with high melanopsin excitation and analyzed with plateau and/or 6s metrics. Our PIPR duration data provide a baseline for the selection of inter-stimulus intervals between consecutive pupil testing sequences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To determine whether melanopsin expressing intrinsically photosensitive Retinal Ganglion Cell (ipRGC) inputs to the pupil light reflex (PLR) are affected in early age-related macular degeneration (AMD). Methods The PLR was measured in 40 participants (20 early AMD and 20 age-matched controls) using a custom-built Maxwellian-view pupillometer. Sinusoidal stimuli (0.5 Hz, 11.9 s duration, 35.6° diameter) were presented to the study eye and the consensual pupil response was measured for stimuli with high melanopsin excitation (464nm; blue) and with low melanopsin excitation (638 nm; red) that biased activation to the outer retina. Two melanopsin PLR metrics were quantified: the Phase Amplitude Percentage (PAP) during the sinusoidal stimulus presentation and the Post-Illumination Pupil Response (PIPR). The PLR during stimulus presentation was analyzed using latency to constriction, transient pupil response and maximum pupil constriction metrics. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curves. Results The blue PIPR was significantly less sustained in the early AMD group (p<0.001). The red PIPR was not significantly different between groups (p>0.05). The PAP and blue stimulus constriction amplitude were significantly lower in the early AMD group (p < 0.05). There was no significant difference between groups in the latency or transient amplitude for both stimuli (p>0.05). ROC analysis showed excellent diagnostic accuracy for the blue PIPR metrics (AUC>0.9). Conclusions This is the initial report that the melanopsin controlled PIPR is dysfunctional in early AMD. The non-invasive, objective measurement of the ipRGC controlled PIPR has excellent diagnostic accuracy for early AMD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose The post-illumination pupil response (PIPR) has been quantified in the literature by four metrics. The spectral sensitivity of only one metric is known and this study quantifies the other three. To optimize the measurement of the PIPR in humans, we also determine the stimulus protocol producing the largest PIPR, the duration of the PIPR, and the metric(s) with the lowest coefficient of variation. Methods The consensual pupil light reflex (PLR) was measured with a Maxwellian view pupillometer (35.6° diameter stimulus). - Experiment 1: Spectral sensitivity of four PIPR metrics [plateau, 6 s, area under curve (AUC) early and late recovery] was determined from a criterion PIPR (n = 2 participants) to a 1 s pulse at five wavelengths (409-592nm) and fitted with Vitamin A nomogram (ƛmax = 482 nm). - Experiment 2: The PLR was measured in five healthy participants [29 to 42 years (mean = 32.6 years)] as a function of three stimulus durations (1 s, 10 s, 30 s), five irradiances spanning low to high melanopsin excitation levels (retinal irradiance: 9.8 to 14.8 log quanta.cm-2.s-1), and two wavelengths, one with high (465 nm) and one with low (637 nm) melanopsin excitation. Intra and inter-individual coefficients of variation (CV) were calculated. Results The melanopsin (opn4) photopigment nomogram adequately described the spectral sensitivity derived from all four PIPR metrics. The largest PIPR amplitude was observed with 1 s short wavelength pulses (retinal irradiance ≥ 12.8 log quanta.cm-2.s-1). Of the 4 PIPR metrics, the plateau and 6 s PIPR showed the least intra and inter-individual CV (≤ 0.2). The maximum duration of the sustained PIPR was 83.4 ± 48.0 s (mean ± SD) for 1 s pulses and 180.1 ± 106.2 s for 30 s pulses (465 nm; 14.8 log quanta.cm-2.s-1). Conclusions All current PIPR metrics provide a direct measure of intrinsic melanopsin retinal ganglion cell function. To measure progressive changes in melanopsin function in disease, we recommend that the intrinsic melanopsin response should be measured using a 1 s pulse with high melanopsin excitation and the PIPR should be analyzed with the plateau and/or 6 s metrics. That the PIPR can have a sustained constriction for as long as 3 minutes, our PIPR duration data provide a baseline for the selection of inter-stimulus intervals between consecutive pupil testing sequences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Melanopsin-expressing retinal ganglion cells (mRGCs) have non-image forming functions including mediation of the pupil light reflex (PLR). There is limited knowledge about mRGC function in retinal disease. Initial retinal changes in age-related macular degeneration (AMD) occur in the paracentral region where mRGCs have their highest density, making them vulnerable during disease onset. In this cross-sectional clinical study, we measured the PLR to determine if mRGC function is altered in early stages of macular degeneration. Methods Pupil responses were measured in 8 early AMD patients (AREDS 2001 classification; mean age 72.6 ± 7.2 years, 5M, and 3F) and 12 healthy control participants (mean age 66.6 ± 6.1 years, 8M and 4F) using a custom-built Maxwellian-view pupillometer. Stimuli were 0.5 Hz sinewaves (10 s duration, 35.6° diameter) of short wavelength light (464nm, blue; retinal irradiance = 14.5 log quanta.cm-2.s-1) to produce high melanopsin excitation and of long wavelength light (638nm, red; retinal irradiance = 14.9 log quanta.cm-2.s-1), to bias activation to outer retina and provide a control. Baseline pupil diameter was determined during a 10 s pre-stimulus period. The post illumination pupil response (PIPR) was recorded for 40 s. The 6 s PIPR and maximum pupil constriction were expressed as percentage baseline (M ± SD). Results The blue PIPR was significantly less sustained (p<0.01) in the early AMD group (75.49 ± 7.88%) than the control group (58.28 ± 9.05%). The red PIPR was not significantly different (p>0.05) between the early AMD (84.79 ± 4.03%) and control groups (82.01 ± 5.86%). Maximum constriction amplitude in the early AMD group for blue (43.67 ± 6.35%) and red (48.64 ± 6.49%) stimuli were not significantly different to the control group for blue (39.94 ± 3.66%) and red (44.98 ± 3.15%) stimuli (p>0.05). Conclusions These results are suggestive of inner retinal mRGC deficits in early AMD. This non-invasive, objective measure of pupil responses may provide a new method for quantifying mRGC function and monitoring AMD progression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Transient changes in corneal topography associated with soft and conventional or reverse geometry rigid contact lens wear have been well documented; however, only a few studies have examined the influence of scleral contact lens wear upon the cornea. Therefore, in this study, we examined the influence of modern miniscleral contact lenses, which land entirely on the sclera and overlying tissues, upon anterior corneal curvature and optics. Methods Anterior corneal topography and elevation data were acquired using Scheimpflug imaging (Pentacam HR, Oculus) immediately prior to and following 8 hours of miniscleral contact lens wear in 15 young healthy adults (mean age 22 ± 3 years, 8 East Asian, 7 Caucasian) with normal corneae. Corneal diurnal variations were accounted for using data collected on a dedicated measurement day without contact lens wear. Corneal clearance was quantified using an optical coherence tomographer (RS-3000, Nidek) following lens insertion and after 8 hours of lens wear. Results Although corneal clearance was maintained throughout the 8 hour lens wear period, significant corneal flattening (up to 0.08 ± 0.04 mm) was observed, primarily in the superior mid-peripheral cornea, which resulted in a slight increase in against-the-rule corneal astigmatism (mean +0.02/-0.15 x 94 for an 8 mm diameter). Higher order aberration terms of horizontal coma, vertical coma and spherical aberration all underwent significant changes for an 8 mm corneal diameter (p ≤ 0.01), which typically resulted in a decrease in RMS error values (mean change in total higher order RMS -0.035 ± 0.046 µm for an 8 mm diameter). There was no association between the magnitude of change in central or mid-peripheral corneal clearance during lens wear and the observed changes in corneal curvature (p > 0.05). However, Asian participants displayed a significantly greater reduction in corneal clearance (p = 0.04) and greater superior-nasal corneal flattening compared to Caucasians (p = 0.048). Conclusions Miniscleral contact lenses that vault the cornea induce significant changes in anterior corneal surface topography and higher order aberrations following 8 hours of lens wear. The region of greatest corneal flattening was observed in the superior-nasal mid-periphery, more so in Asian participants. Practitioners should be aware that corneal measurements obtained following miniscleral lens removal may mask underlying corneal steepening.