805 resultados para you tube
Resumo:
Rupture of a light cellophane diaphragm in an expansion tube has been studied by an optical method. The influence of the light diaphragm on test flow generation has long been recognised, however the diaphragm rupture mechanism is less well known. It has been previously postulated that the diaphragm ruptures around its periphery due to the dynamic pressure loading of the shock wave, with the diaphragm material at some stage being removed from the flow to allow the shock to accelerate to the measured speeds downstream. The images obtained in this series of experiments are the first to show the mechanism of diaphragm rupture and mass removal in an expansion tube. A light diaphragm was impulsively loaded via a shock wave and a series of images was recorded holographically throughout the rupture process, showing gradual destruction of the diaphragm. Features such as the diaphragm material, the interface between gases, and a reflected shock were clearly visualised. Both qualitative and quantitative aspects of the rupture dynamics were derived from the images and compared with existing one-dimensional theory.
Resumo:
The effectiveness of overt tobacco advertising and sponsorship bans is well established. The industry has responded to these bans by implementing “buzz” or “viral” marketing techniques, such as nightclub and dance party promotions. This paper analyses possible tobacco industry content on the burgeoning consumer generated media website, YouTube. Tobacco control efforts need to embrace this new medium in order to counter pro-smoking messages and maximize media advocacy opportunities.
Resumo:
A numerical study is reported to investigate both the First and the Second Law of Thermodynamics for thermally developing forced convection in a circular tube filled by a saturated porous medium, with uniform wall temperature, and with the effects of viscous dissipation included. A theoretical analysis is also presented to study the problem for the asymptotic region applying the perturbation solution of the Brinkman momentum equation reported by Hooman and Kani [1]. Expressions are reported for the temperature profile, the Nusselt number, the Bejan number, and the dimensionless entropy generation rate in the asymptotic region. Numerical results are found to be in good agreement with theoretical counterparts.
Resumo:
Published in the final months of 1891, Architecture, Mysticism and Myth was the first architectural treatise written by the late nineteenth-century English architect and theorist William Richard Lethaby (1857-1931).' Documenting the characteristic attributes of the architectural myth of the "temple idea", and its presence amongst architectures of multiple ancient cultures, the text was endowed with a distinctly historical tone. In examining the motives behind myth, which Lethaby defined as the interaction and reaction between the natural universe and the built environment, Lethaby also injected a series of theoretical considerations into the text. It is clear that Lethaby's interest in the temple idea was not limited to its curious, prolific presence in past architectures, hut also embraced a consideration of what lessons the temple idea may contribute to the struggle of the late nineteenth-century English architect to define an "art of the future".
Resumo:
Free-piston-driven expansion tubes are capable of generating flaw conditions over a wide range of enthalpies ranging from orbital up to superorbital velocities. Initial optical measurements aimed at investigating the flow in such a facility are presented. Emission studies were used to identify impurities in the how and to investigate spectral regions that are accessible by optical techniques. At moderate enthalpies, it was found that significant radiation resulted from metallic contaminants. At high enthalpies, the spectrum consisted of a number of atomic lines together with a broadband background component indicative of the presence of electrons. The presence of this radiation may limit the applicability of optical techniques that require spectral regions free from the influence of atomic transitions or background radiation. Emission spectroscopy (through Stark broadened hydrogen lines) and two-wavelength holographic interferometry were used to measure the electron number density behind a bow shock on a blunt body at conditions where significant ionization was observed. They yielded average concentrations of (3 +/- 1) x 10(17) cm(-3) from the emission measurements and (3.8 +/- 0.6) x 10(17) cm(-3) from the interferometry.
Resumo:
Group criticisms judged to be reasonable in the mouth of an ingroup member are aggressively rejected when they stem from an outgroup member (the intergroup sensitivity effect). Mediational analyses suggest that this phenomenon is underpinned by an attributional bias; criticisms from insiders are more likely to be perceived as being motivated for constructive reasons than are criticisms from outsiders, thus arousing lower levels of defensiveness. But what if group members were to receive information that called into question the ingroup critic's commitment to the group? For example, if the ingroup critic was known to be a low identifier with their group, or used language to suggest that they were psychologically distancing themselves from their group, we might expect that ingroup critics will be downgraded as strongly as outgroup critics. Furthermore, it might be possible for people to turn an outgroup criticism into an ingroup criticism by making salient their shared identity at the superordinate level. Three experiments are described that provide support for each of these propositions.
Resumo:
A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for simultaneous determination of mirrazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline in human plasma was developed, validated and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. The quantification limits of the in-tube SPME/LC method varied between 20 and 50 ng/mL, with a coefficient of variation lower than 10%. The response of the in-tube SPME/LC method for most of the drugs was linear over a dynamic range from 50 to 500 ng/mL, with correlation coefficients higher than 0.9985. The in-tube SPME/LC can be successfully used to analyze plasma samples from ageing patients undergoing therapy with nontricyclic antidepressants. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
There are times when people feel compelled to stand up and articulate their group's shortcomings, an act that carries with it enormous social risks. Indeed, a mechanistic reading of social identity theory might lead one to believe that ingroup critics are doomed to face hostility because they are attacking a fundamental part of people's self-concept. But often ingroup critics are doing more than attacking their group — they are trying to incite positive change. Criticism is the cornerstone of protest, and it is difficult to imagine how a group can be reinvigorated, reinvented, or reformed without some process of critical self-reflection. Thus, although the ingroup critic might create tension within the group, it is possible that internal criticism could be seen by other group members as beneficial in terms of promoting positive change and stimulating innovation, creativity, and flexibility in decision making. In this talk I examine the 'identity rules' that ingroup critics need to follow to avoid defensiveness, and look at empirical evidence of how factors such as language, the intergroup context, and choice of audience shape people's attributions regarding criticism and their subsequent evaluations of critics.
Resumo:
A sensitive, selective, and reproducible in-tube polypyrrole-coated capillary (PPY) solid-phase microextraction and liquid chromatographic method for fluoxetine and norfluoxetine enantiomers analysis in plasma samples has been developed, validated, and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. Separation of the analytes was achieved with a Chiralcel OD-R column and a mobile phase consisting of potassium hexafluorophosphate 7.5 mM and sodium phosphate 0.25 M solution, pH 3.0, and acetonitrile (75:25, v/v) in the isocratic mode, at a flow rate of 1.0 mL/min. Detection was carried out by fluorescence absorbance at Ex/Em 230/290 nm. The multifunctional porous surface structure of the PPY-coated film provided high precision and accuracy for enantiomers. Compared with other commercial capillaries, PPY-coated capillary showed better extraction efficiency for all the analytes. The quantification limits of the proposed method were 10 ng/mL for R- and S-fluoxetine, and 15 ng/mL for R- and S-norfluoxetine, with a coefficient of variation lower than 13%. The response of the method for enantiomers is linear over a dynamic range, from the limit of quantification to 700ng/mL, with correlation coefficients higher than 0.9940. The in-tube SPME/LC method can therefore be successfully used to analyze plasma samples from ageing patients undergoing therapy with fluoxetine. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and automated method is described for determination of rifampicin in plasma samples for therapeutic drug monitoring by in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC). Important factors in the optimization of in-tube SPME are discussed, such as coating type, sample pH, sample draw/eject volume, number of draw/eject cycles, and draw/eject flow rate. Analyte pre-concentrated in the polyethylene glycol phase was directly transferred to the liquid chromatographic column by percolation of the mobile phase, without carryover. The method was linear over the 0.1-100 mu g/mL range, with a linear coefficient value (r(2)) of 0.998. The inter-assay precision presented coefficient of variation <= 1.7%. The effectiveness and practicability of the proposed method are proven by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. (C) 2011 Elsevier B.V. All rights reserved.