993 resultados para working length


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aims of this study were to evaluate the effect of root canal filling techniques on root fracture resistance and to analyze, by finite element analysis (FEA), the expansion of the endodontic sealer in two different root canal techniques. Thirty single-rooted human teeth were instrumented with rotary files to a standardized working length of 14 mm. The specimens were embedded in acrylic resin using plastic cylinders as molds, and allocated into 3 groups (n=10): G(lateral) - lateral condensation; G(single-cone) - single cone; G(tagger) - Tagger's hybrid technique. The root canals were prepared to a length of 11 mm with the #3 preparation bur of a tapered glass fiber-reinforced composite post system. All roots received glass fiber posts, which were adhesively cemented and a composite resin core was built. All groups were subjected to a fracture strength test (1 mm/min, 45°). Data were analyzed statistically by one-way ANOVA with a significance level of 5%. FEA was performed using two models: one simulated lateral condensation and Tagger's hybrid technique, and the other one simulated the single-cone technique. The second model was designed with an amount of gutta-percha two times smaller and a sealer layer two times thicker than the first model. The results were analyzed using von Mises stress criteria. One-way ANOVA indicated that the root canal filling technique affected the fracture strength (p=0.004). The G(lateral) and G(tagger) produced similar fracture strength values, while G(single-cone) showed the lowest values. The FEA showed that the single-cone model generated higher stress in the root canal walls. Sealer thickness seems to influence the fracture strength of restored endodontically treated teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). Material and methods: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the pre-flaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra-and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). Results: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. Conclusions: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to assess, in vivo, the accuracy of the NovApex (R) electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex (R) was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex (R) locator and confirmed using the radiographic method. Differences between electronic and radiographic measurements ranging between 0.0 and 0.4 millimeters were classified as acceptable; differences equal to or greater than 0.5 millimeter were considered unacceptable. Pearson's chi-square test was used to assess the influence of pulp condition on the accuracy of NovApex (R) (alpha = 0.05). Regardless of pulp condition, differences between electronic and radiographic WL measurements were acceptable in 73.61% of the canals. No statistically significant differences in accuracy were observed when comparing vital and necrotic canals (p > 0.05). There were 38 unacceptable measurements. In none of these cases was the file tip located beyond the radiographic apex; in 32, it was located short of the NovApex (R) measurement. Pulp condition had no significant effect on the accuracy of NovApex (R).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate in vivo the clinical applicability of two electronic apex locators (EALs) - Apex (Septodont) and iPex (NSK) - in different groups of human teeth by using radiography. The working lengths (WLs) of 100 root canals were determined electronically. The EAL to be used first was chosen randomly and a K-file was inserted into the root canal until the EAL display indicated the location of the apical constriction (0 mm). The K-file was fixed to the tooth and a periapical radiograph was taken using a radiographic film holder. The K-file was removed and the WL was measured. The same procedure was repeated using the other EAL. Radiographs were examined with the aid of a light-box with lens of ×4 magnification by two blinded experienced endodontists. The distance between the file tip and the root apex was recorded as follows: (A) +1 to 0 mm, (B) -0.1 to 0.5 mm, (C) -0.6 to 1 mm, (D) -1.1 to 1.5 mm, and (E) -1.6 mm or greater. For statistical purposes, these scores were divided into 2 subgroups according to the radiographic apex: acceptable (B, C, and D) and non-acceptable (A and E). Statistically significant differences were not found between the results of Apex and iPex in terms of acceptable and non-acceptable measurements (p>0.05) or in terms of the distance recorded from file tip and the radiographic apex (p>0.05). Apex and iPex EALs provided reliable measurements for WL determination for endodontic therapy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Deep hole drilling is one of the most complicated metal cutting processes and one of the most difficult to perform on CNC machine-tools or machining centres under conditions of limited manpower or unmanned operation. This research work investigates aspects of the deep hole drilling process with small diameter twist drills and presents a prototype system for real time process monitoring and adaptive control; two main research objectives are fulfilled in particular : First objective is the experimental investigation of the mechanics of the deep hole drilling process, using twist drills without internal coolant supply, in the range of diarneters Ø 2.4 to Ø4.5 mm and working length up to 40 diameters. The definition of the problems associated with the low strength of these tools and the study of mechanisms of catastrophic failure which manifest themselves well before and along with the classic mechanism of tool wear. The relationships between drilling thrust and torque with the depth of penetration and the various machining conditions are also investigated and the experimental evidence suggests that the process is inherently unstable at depths beyond a few diameters. Second objective is the design and implementation of a system for intelligent CNC deep hole drilling, the main task of which is to ensure integrity of the process and the safety of the tool and the workpiece. This task is achieved by means of interfacing the CNC system of the machine tool to an external computer which performs the following functions: On-line monitoring of the drilling thrust and torque, adaptive control of feed rate, spindle speed and tool penetration (Z-axis), indirect monitoring of tool wear by pattern recognition of variations of the drilling thrust with cumulative cutting time and drilled depth, operation as a data base for tools and workpieces and finally issuing of alarms and diagnostic messages.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To compare soft-tissue dissolution by sodium hypochlorite, with an EDTA intermediate rinse, with or without activation with passive ultrasonic activation (PUI) or sonic activation using the Endoactivator (EA) or Eddy tips (ED). Methodology: The root canals of eighty-three human maxillary central incisors were chemo-mechanically prepared and the teeth split. A standardized longitudinal intracanal groove was created in one of the root halves. Eighty-three porcine palatal mucosa samples were collected, adapted to fit into the grooves and weighed. The re-assembled specimens were randomly divided into four experimental groups (n = 20), based on the final rinse: no activation; EA; PUI; ED, using 2.5% sodium hypochlorite, with an EDTA intermediate rinse. A control group (n = 3) was irrigated with distilled water without activation. The solutions were delivered using a syringe and needle 2 mm from working length. Total irrigation time was 150 s, including 60 s of activation in the specific groups. The study was carried out at 36 ± 2 °C. The porcine palatal mucosa samples were weighed after completion of the assays. Student paired t-test and anova were used to assess the intra- and intergroup weight changes. The multiple comparisons were evaluated using Bonferroni correction (α = 0.05). Results: Weight loss occurred in all experimental groups. Irrigant activation resulted in greater weight loss when compared to the nonactivated group [vs. EA (P = 0.001); vs. PUI (P < 0.001); vs. ED (P < 0.001)]. No significant differences were found amongst the different activation systems. Conclusions: Activation increased the tissue-dissolving activity of irrigants from artificial grooves in root canals of maxillary central incisors. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Success in the advancement of thermoacoustic field led the researchers to develop the thermoacoustic engines which found its applications in various fields such as refrigeration, gas mixture separation, natural gas liquefaction, and cryogenics. The objective of this study is to design and fabricate the twin thermoacoustic heat engine (TAHE) producing the acoustic waves with high resonance frequencies which is used to drive a thermoacoustic refrigerator efficiently by the influence of geometrical parameters and working fluids. Twin TAHE has gained significant attention due to the production of high intensity acoustic waves than single TAHE. In order to drive an efficient thermoacoustic refrigerator, a twin thermoacoustic heat engine is built up and its performance are analysed by varying the resonator length and working fluid. The performance is measured in terms of onset temperature difference, resonance frequency and pressure amplitude of the oscillations generated from twin TAHE. The simulation is performed using free software DeltaEC, from LANL, USA. The simulated DeltaEC results are compared with experimental results and the deviations are found within +10%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Patients with schizophrenia display numerous cognitive deficits, including problems in working memory, time estimation, and absolute identification of stimuli. Research in these fields has traditionally been conducted independently. We examined these cognitive processes using tasks that are structurally similar and that yield rich error data. Relative to healthy control participants (n = 20), patients with schizophrenia (n = 20) were impaired on a duration identification task and a probed-recall memory task but not on a line-length identification task. These findings do not support the notion of a global impairment in absolute identification in schizophrenia. However, the authors suggest that some aspect of temporal information processing is indeed disturbed in schizophrenia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It is the aim of the present study to assess factors associated with time spent in class among working college students. Eighty-two working students from 21 to 26 years old participated in this study. They were enrolled in an evening course of the University of Sao Paulo, Brazil. Participants answered a questionnaire on living and working conditions. During seven consecutive days, they wore an actigraph, filled out daily activity diaries (including time spent in classes) and the Karolinska Sleepiness Scale every three hours from waking until bedtime. Linear regression analyses were performed in order to assess the variables associated with time spent in classes. The results showed that gender, sleep length, excessive sleepiness, alcoholic beverage consumption (during workdays) and working hours were associated factors with time spent in class. Thus, those who spent less time in class were males, slept longer hours, reported excessive sleepiness on Saturdays, worked longer hours, and reported alcohol consumption. The combined effects of long work hours (>40 h/week) and reduced sleep length may affect lifestyles and academic performance. Future studies should aim to look at adverse health effects induced by reduced sleep duration, even among working students who spent more time attending evening classes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although a number of studies have investigated the predictors of employment among refugee migrants, there is a dearth of evidence from longitudinal data. This study investigated the cross-sectional and longitudinal predictors of employment among 233 adult refugee men living in South-East Queensland, Australia. Participants were interviewed four times at six-month intervals between 2008 and 2010. Using a conceptual model developed from the literature, Generalised Estimating Equations were used to model the predictors of employment. Over time, the employment rate increased from 44 percent to 56 percent. Region of birth, length of time in Australia, seeking employment through job service providers and informal networks, and owning a car were significant predictors of employment. Contrary to previous research, English language proficiency was not a significant predictor when other variables were controlled for. Recognition of overseas skills and qualifications decreased the chances of finding employment. The policy and program implications are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thermoacoustic engines convert heat energy into high amplitude sound waves, which is used to drive thermoacoustic refrigerator or pulse tube cryocoolers by replacing the mechanical pistons such as compressors. The increasing interest in thermoacoustic technology is of its potentiality of no exotic materials, low cost and high reliability compared to vapor compression refrigeration systems. The experimental setup has been built based on the linear thermoacoustic model and some simple design parameters. The engines produce acoustic energy at the temperature difference of 325-450 K imposed along the stack of the system. This work illustrates the influence of stack parameters such as plate thickness (PT) and plate spacing (PS) with resonator length on the performance of thermoacoustic engine, which are measured in terms of onset temperature difference, resonance frequency and pressure amplitude using air as a working fluid. The results obtained from the experiments are in good agreement with the theoretical results from DeltaEc. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The generation, jet length and flow-regime change characteristics of argon plasma issuing into ambient air have been experimentally examined. Different torch structures have been used in the tests. Laminar plasma jets can be generated within a rather wide range of working-gas flow rates, and an unsteady transitional flow state exists between the laminar and turbulent flow regimes. The high-temperature region length of the laminar plasma jet can be over an order longer than that of the turbulent plasma jet and increases with increasing argon flow rate or arc current, while the jet length of the turbulent plasma is less influenced by the generating parameters. The flow field of the plasma jet has very high radial gradients of plasma parameters, and a Reynolds number alone calculated in the ordinary manner may not adequately serve as a criterion for transition. The laminar plasma jet can have a higher velocity than that of an unsteady or turbulent jet. The long laminar plasma jet has good stiffness to withstand the impact of laterally injected cold gas and particulate matter. It could be used as a rather ideal object for fundamental studies and be applied to novel materials processing due to its attractive stable and adjustable properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel technique, using a 'flying' Hot Wire Anemometer is described; it is shown how the turbulent structure in a motored engine, using a high molecular weight gas as the working fluid, may be investigated with relative simplicity and very little engine modification. Initial results are presented for integral and micro length scales, which are within the range expected based on previous work. Copyright © 1987 Society of Automotive Engineers, Inc.