945 resultados para voltage source converters
Resumo:
The voltage source inverter (VSI) and current voltage source inverter (CSI) are widely used in industrial application. But the traditional VSIs and CSIs have one common problem: can’t boost or buck the voltage come from battery, which make them impossible to be used alone in Hybrid Electric Vehicle (HEV/EV) motor drive application, other issue is the traditional inverter need to add the dead-band time into the control sequence, but it will cause the output waveform distortion. This report presents an impedance source (Z-source network) topology to overcome these problems, it can use one stage instead of two stages (VSI or CSI + boost converter) to buck/boost the voltage come from battery in inverter system. Therefore, the Z-source topology hardware design can reduce switching element, entire system size and weight, minimize the system cost and increase the system efficiency. Also, a modified space vector pulse-width modulation (SVPWM) control method has been selected with the Z-source network together to achieve the best efficiency and lower total harmonic distortion (THD) at different modulation indexes. Finally, the Z-source inverter controlling will modulate under two control sequences: sinusoidal pulse width modulation (SPWM) and SVPWM, and their output voltage, ripple and THD will be compared.
Resumo:
Efficient and reliable techniques for power delivery and utilization are needed to account for the increased penetration of renewable energy sources in electric power systems. Such methods are also required for current and future demands of plug-in electric vehicles and high-power electronic loads. Distributed control and optimal power network architectures will lead to viable solutions to the energy management issue with high level of reliability and security. This dissertation is aimed at developing and verifying new techniques for distributed control by deploying DC microgrids, involving distributed renewable generation and energy storage, through the operating AC power system. To achieve the findings of this dissertation, an energy system architecture was developed involving AC and DC networks, both with distributed generations and demands. The various components of the DC microgrid were designed and built including DC-DC converters, voltage source inverters (VSI) and AC-DC rectifiers featuring novel designs developed by the candidate. New control techniques were developed and implemented to maximize the operating range of the power conditioning units used for integrating renewable energy into the DC bus. The control and operation of the DC microgrids in the hybrid AC/DC system involve intelligent energy management. Real-time energy management algorithms were developed and experimentally verified. These algorithms are based on intelligent decision-making elements along with an optimization process. This was aimed at enhancing the overall performance of the power system and mitigating the effect of heavy non-linear loads with variable intensity and duration. The developed algorithms were also used for managing the charging/discharging process of plug-in electric vehicle emulators. The protection of the proposed hybrid AC/DC power system was studied. Fault analysis and protection scheme and coordination, in addition to ideas on how to retrofit currently available protection concepts and devices for AC systems in a DC network, were presented. A study was also conducted on the effect of changing the distribution architecture and distributing the storage assets on the various zones of the network on the system’s dynamic security and stability. A practical shipboard power system was studied as an example of a hybrid AC/DC power system involving pulsed loads. Generally, the proposed hybrid AC/DC power system, besides most of the ideas, controls and algorithms presented in this dissertation, were experimentally verified at the Smart Grid Testbed, Energy Systems Research Laboratory. All the developments in this dissertation were experimentally verified at the Smart Grid Testbed.
Resumo:
The objective of this work is to present the finite element modeling of laminate composite plates with embedded piezoelectric patches or layers that are then connected to active-passive resonant shunt circuits, composed of resistance, inductance and voltage source. Applications to passive vibration control and active control authority enhancement are also presented and discussed. The finite element model is based on an equivalent single layer theory combined with a third-order shear deformation theory. A stress-voltage electromechanical model is considered for the piezoelectric materials fully coupled to the electrical circuits. To this end, the electrical circuit equations are also included in the variational formulation. Hence, conservation of charge and full electromechanical coupling are guaranteed. The formulation results in a coupled finite element model with mechanical (displacements) and electrical (charges at electrodes) degrees of freedom. For a Graphite-Epoxy (Carbon-Fibre Reinforced) laminate composite plate, a parametric analysis is performed to evaluate optimal locations along the plate plane (xy) and thickness (z) that maximize the effective modal electromechanical coupling coefficient. Then, the passive vibration control performance is evaluated for a network of optimally located shunted piezoelectric patches embedded in the plate, through the design of resistance and inductance values of each circuit, to reduce the vibration amplitude of the first four vibration modes. A vibration amplitude reduction of at least 10 dB for all vibration modes was observed. Then, an analysis of the control authority enhancement due to the resonant shunt circuit, when the piezoelectric patches are used as actuators, is performed. It is shown that the control authority can indeed be improved near a selected resonance even with multiple pairs of piezoelectric patches and active-passive circuits acting simultaneously. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents a variable speed autonomous squirrel cage generator excited by a current-controlled voltage source inverter to be used in stand-alone micro-hydro power plants. The paper proposes a system control strategy aiming to properly excite the machine as well as to achieve the load voltage control. A feed-forward control sets the appropriate generator flux by taking into account the actual speed and the desired load voltage. A load voltage control loop is used to adjust the generated active power in order to sustain the load voltage at a reference value. The control system is based on a rotor flux oriented vector control technique which takes into account the machine saturation effect. The proposed control strategy and the adopted system models were validated both by numerical simulation and by experimental results obtained from a laboratory prototype. Results covering the prototype start-up, as well as its steady-state and dynamical behavior are presented. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Neste trabalho é desenvolvida uma bancada didáctica que permite simular o funcionamento de um sistema de microgeração. A bancada inclui uma máquina síncrona responsável pela geração de energia eléctrica acoplada a uma máquina de indução que simula a máquina primária. A máquina de indução é controlada por um sistema electrónico de controlo de potência (variador de velocidade) que permite manter constante a velocidade de rotação e consequentemente a frequência da tensão gerada pela máquina síncrona. Por sua vez, a excitação da máquina síncrona é controla por uma fonte de tensão externa. A parametrização e controlo do variador de velocidade, assim como o controlo da fonte de tensão externa, são feitos a partir dum software que corre num PC, que também monitoriza a tensão gerada pela máquina síncrona. Este software é ainda responsável pela interface com o utilizador. O software desenvolvido permite manter as características da tensão gerada pela máquina síncrona independentemente da carga imposta.
Resumo:
Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometers require controlled current sources in order to get accurate flux density with respect to its magnet. The main elements of the proposed solution are a power semiconductor, a DC voltage source and the magnet. The power semiconductor is commanded in order to get a linear control of the flux density. To implement the flux density control, a Hall Effect sensor is used. Furthermore, the dynamic behavior of the current source is analyzed and compared when using a PI controller and a PD2I controller.
Resumo:
Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometers require controlled current sources in order to get accurate flux density with respect to its magnet. The main elements of the proposed solution are a power semiconductor, a DC voltage source and the magnet. The power semiconductor is commanded in order to get a linear control of the flux density. To implement the flux density control, a Hall Effect sensor is used. Furthermore, the dynamic behavior of the current source is analyzed and compared when using a PI controller and a PD2I controller.
Resumo:
This paper presents solutions for fault detection and diagnosis of two-level, three phase voltage-source inverter (VSI) topologies with IGBT devices. The proposed solutions combine redundant standby VSI structures and contactors (or relays) to improve the fault-tolerant capabilities of power electronics in applications with safety requirements. The suitable combination of these elements gives the inverter the ability to maintain energy processing in the occurrence of several failure modes, including short-circuit in IGBT devices, thus extending its reliability and availability. A survey of previously developed fault-tolerant VSI structures and several aspects of failure modes, detection and isolation mechanisms within VSI is first discussed. Hardware solutions for the protection of power semiconductors with fault detection and diagnosis mechanisms are then proposed to provide conditions to isolate and replace damaged power devices (or branches) in real time. Experimental results from a prototype are included to validate the proposed solutions.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial
Resumo:
A dificuldade de controlo de um motor de indução, bem como o armazenamento de energia CC e posterior utilização como energia alternada promoveram o desenvolvimento de variadores de frequência e inversores. Assim, como projeto de tese de mestrado em Automação e Sistemas surge o desenvolvimento de um variador de frequência. Para elaboração do variador de frequência efetuou-se um estudo sobre as técnicas de modulação utilizadas nos inversores. A técnica escolhida e utilizada é a Sinusoidal Pulse Width Modulation (SPWM). Esta técnica baseia-se na modelação por largura de impulso (PWM), o qual é formado por comparação de um sinal de referência com um sinal de portadora de elevada frequência. Por sua vez, a topologia escolhida para o inversor corresponde a um Voltage Source Inverter (VSI) de ponte trifásica completa a três terminais. O desenvolvimento da técnica de modulação SPWM levou ao desenvolvimento de um modelo de simulação em SIMULINK, o qual permitiu retirar conclusões sobre os resultados obtidos. Na fase de implementação, foram desenvolvidas placas para o funcionamento do variador de frequência. Assim, numa fase inicial foi desenvolvida a placa de controlo, a qual contém a unidade de processamento e que é responsável pela atuação de Insulated Gate Bipolar Transistors (IGBTs). Para além disso, foi desenvolvida uma placa para proteção dos IGBTs (evitando condução simultânea no mesmo terminal) e uma placa de fontes isoladas para alimentação dos circuitos e para atuação dos IGBTs. Ainda, foi desenvolvida a técnica de SPWM em software para a unidade de controlo e finalmente foi desenvolvida uma interface gráfica para interação com o utilizador. A validação do projeto foi conseguida através da variação da velocidade do motor de indução trifásico. Para isso, este foi colocado a funcionar a diversas frequências de funcionamento e a diferentes amplitudes. Para além disso, o seu funcionamento foi também validado utilizando uma carga trifásica equilibrada de 3 lâmpadas de forma a ser visualizada a variação de frequência e variação de amplitude.
Resumo:
E. coli was submitted to a 5G electromagnetic field generated by a alternate 60 Hz voltage source. The differences on growth and glucose consume in control and exposed groups were evaluated using the non-parametric Mann-Whitney U-test. There was a significant difference in glucose consume and growth in E. coli after 8 hours of exposition to electromagnetic field. It can be concluded that electromagnetic field had a positive effect in consume of glucose and growth of E. coli. The cause of these results can be explained by an increasing of glucose entrance through membrane due to the stimulated transport system via Facility Diffusion or cyclotron resonance. The growth can be caused by shortening of lag phase and excitement of log phase.
Resumo:
This paper presents a single-phase Series Active Power Filter (Series APF) for mitigation of the load voltage harmonic content, while maintaining the voltage on the DC side regulated without the support of a voltage source. The proposed series active power filter control algorithm eliminates the additional voltage source to regulate the DC voltage, and with the adopted topology it is not used a coupling transformer to interface the series active power filter with the electrical power grid. The paper describes the control strategy which encapsulates the grid synchronization scheme, the compensation voltage calculation, the damping algorithm and the dead-time compensation. The topology and control strategy of the series active power filter have been evaluated in simulation software and simulations results are presented. Experimental results, obtained with a developed laboratorial prototype, validate the theoretical assumptions, and are within the harmonic spectrum limits imposed by the international recommendations of the IEEE-519 Standard.
Resumo:
Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e de Computadores
Resumo:
გეოფიზიკის ინსტიტუტში შექმნილია კომპაქტური (1 კგ.) მაღალი ძაბვის (1200 ვოლტამდე) დენის წყარო ელექტროძიებისათვის. დენის წყაროს გამოცდამ საველე პირობებში დაადასტურა მისი მაღალი ეფექტურობა.
Resumo:
Diplomityössä on tutkittu sähköisellä potkurijärjestelmällä varustetun laivan voimalaitoksen ja jännitevälipiirillisen propulsiokäytön vuorovaikutusta laivan hätäpysäytyksen aikana. Työssä on kehitetty simulointimalleja jännitevälipiirillisten sähkökäyttöjen simuloimiseksi Saber -simulontiohjelmistolla.Työn alkuosassa esitetään lyhyt yhteenveto laivan sähköisestä potkurijärjestelmästä komponentteineen, käsitellään laivan hätäpysäytyksen teoriaa sekä simuloinneissa huomioonotettavia laivan ja potkurin hydrodynaamisia ominaisuuksia. Työssä käytettävän simulointiohjelmiston toimintaa selvitetään lyhyesti. Jännitevälipiirillisellä propulsiokäytöllä varustetun laivan hätäpysäytyksen simulointimalli esitellään kokonaisuudessaan ja käsitellään simulointimallin sisältämien osakokonaisuuksien teoriaa ja toimintaa. Kehitetyn simulointimallin toimintaa on tarkasteltu vertaamalla tuloksia vastaavansyklokonvertterikäytöllä varustetun laivan simulointituloksiin sekä vertaamallasimulointituloksia laivan merikoeajon yhteydessä tehtyihin mittauksiin. Simulointitulokset vastasivat teoriaa sekä mittaustuloksia varsin hyvin. Voimalaitoksenosalta ei mittaustuloksia ollut käytettävissä, mutta simulointitulokset ovat teorian mukaisia.