976 resultados para ventilation system
Resumo:
The method of distributing the outdoor air in classrooms has a major impact on indoor air quality and thermal comfort of pupils. In a previous study, ([11] Karimipanah T, Sandberg M, Awbi HB. A comparative study of different air distribution systems in a classroom. In: Proceedings of Roomvent 2000, vol. II, Reading, UK, 2000. p. 1013-18; [13] Karimipanah T, Sandberg M, Awbi HB, Blomqvist C. Effectiveness of confluent jets ventilation system for classrooms. In: Idoor Air 2005, Beijing, China, 2005 (to be presented).) presented results for four and two types of air distribution systems tested in a purpose built classroom with simulated occupancy as well as computational fluid dynamics (CFD) modelling. In this paper, the same experimental setup has been used to investigate the indoor environment in the classroom using confluent jet ventilation, see also ([12]Cho YJ, Awbi HB, Karimipanah T. The characteristics of wall confluent jets for ventilated enclosures. In: Proceedings of Roomvent 2004, Coimbra, Portugal, 2004.) Measurements of air speed, air temperature and tracer gas concentrations have been carried out for different thermal conditions. In addition, 56 cases of CFD simulations have been carried to provide additional information on the indoor air quality and comfort conditions throughout the classroom, such as ventilation effectiveness, air exchange effectiveness, effect of flow rate, effect of radiation, effect of supply temperature, etc., and these are compared with measured data.
Resumo:
I detta examensarbete undersöktes möjligheten att installera värmeåtervinningssystem för ett flerfamiljehus i Hovgården som ligger en bit utanför Borlänge. I rapporten redovisas två olika sätt för energibesparingar som är aktuella för att ersätta borttagning av oljepannan som används i huset i dag. En rad svårigheter dök upp under undersökningen för installation av nytt värmesystem. Lämpliga lösningar kunde hittas efter mycket analys. Syftet med rapporten var att undersöka möjligheten och lönsamheten för installation av något av följande system; FVP eller VBX-modul som kan återvinna värme ur frånluften. Undersökningen visade att varken VBX eller FVP kan ersätta oljepannans värmeavgivning på ett tillfredsställande sätt. Med VBX ökas COP från 2,8 till 3,11 vilket leder till 17 MWh/år elbesparing. Däremot FVP kan försörja huset med 59 MWh/år men kan inte täcka effektbehovet för gården under kallaste dagarna. Resultatet blev att de båda undersökta systemen inte har möjlighet att ersätta oljeeldning.
Resumo:
With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
The airliner cabin environment and its effects on occupant health have not been fully characterized. This dissertation is: (1) A review of airliner environmental control systems (ECSs) that modulate the ventilation, temperature, relative humidity (RH), and barometric pressure (PB) of the cabin environment---variables related to occupant comfort and health. (2) A review and assessment of the methods and findings of key cabin air quality (CAQ) investigations. Several significant deficiencies impede the drawing of inferences about CAQ, e.g., lack of detail about investigative methods, differences in methods between investigations, limited assessment of CAQ variables, small sample sizes, and technological deficiencies of data collection. (3) A comprehensive evaluation of the methods used in the subsequent NIOSH-FAA Airliner CAQ Exposure Assessment Feasibility Study (STUDY) in which this author participated. A number of problems were identified which limit the usefulness of the data. (4) An analysis of the reliable 10-flight STUDY data. Univariate and multivariate methods applied to CO2 (a surrogate for air contaminants), temperature, RH, and PB, in association with percent passenger load, ventilation system, flight duration, airliner body type, and measurement location within the cabin, revealed neither the measured values nor their variability exceeded established health-based exposure limits. Regression analyses suggest CO2, temperature, and RH were affected by percent passenger load. In-flight measurements of CO2 and RH were relatively independent of ventilation system type or flight duration. Cabin temperature was associated with percent passenger load, ventilation system type, and flight duration. (5) A synthesis of the implications of the airliner ECS and cabin O2 environment on occupant health. A model was developed to predict consequences of the airliner cabin pressure altitude 8,000 ft limit and resulting model-estimated PO2 on cardiopulmonary status. Based on the PB, altitude, and environmental data derived from the 10 STUDY flights, the predicted PaO2 of adults with COPD, or elderly adults with or without COPD, breathing ambient cabin air could be < 55 mm Hg (SaO2 < 88%). Reduction in cabin PB found in the STUDY flights could aggravate various medical conditions and require the use of in-flight supplemental O2. ^
Resumo:
Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^
Resumo:
The main objective of ventilation systems in case of fire is the reduction of the possible consequences by achieving the best possible conditions for the evacuation of the users and the intervention of the emergency services. In the last years, the required quick response of the ventilation system, from normal to emergency mode, has been improved by the use of automatic and semi-automatic control systems, what reduces the response times through the support to the operators decision taking, and the use of pre-defined strategies. A further step consists on the use of closedloop algorithms, which takes into account not only the initial conditions but their development (air velocity, traffic situation, etc), optimizing the quality of the smoke control process
Resumo:
En la actualidad, el crecimiento de la población urbana, el incremento de la demanda energética junto al desarrollo tecnológico impulsado en los últimos veinte años han originado un estudio y replanteamiento de los sistemas constructivos empleados. Como consecuencia se han establecido nuevos marcos normativos, marcando nuevos objetivos de confort y de demanda energética. En España, el Código Técnico de la Edificación (aprobado en el Real Decreto 314/2006 de 17 de Marzo) es el marco normativo que establece las exigencias que se deben cumplir al proyectar construir, usar, mantener y conservar los edificios, incluidas sus instalaciones, con el fin de asegurar la calidad, seguridad y salud del usuario, respetando en todo momento su entorno. Para asegurar el cumplimiento de las exigencias del Código Técnico de la Edificación (CTE), se han elaborado diferentes Documentos Básicos (DB). Entre ellos están los documentos básicos DB HR-Protección frente al ruido y el DB HS-Salubridad. En el DB HS 3 Calidad del aire interior, se establecen las condiciones que deben de adoptarse para que los recintos de los edificios se puedan ventilar adecuadamente, eliminando los contaminantes que se produzcan de forma habitual durante un uso normal de los edificios, de forma que se aporte un caudal suficiente de aire exterior y se garantice la extracción y expulsión del aire viciado por los contaminantes. En el apartado 3.1, Condiciones generales de los sistemas de ventilación, se indica que las viviendas deben disponer de un sistema general de ventilación donde el aire debe circular desde los locales secos a los húmedos. Para ello los comedores, los dormitorios y las salas de estar deben de disponer de aberturas de admisión, pudiéndose resolver esta cuestión técnica con diversas soluciones. El DB HR Protección frente al ruido del CTE, establece unos valores del aislamiento acústico a ruido aéreo, entre un recinto protegido y el exterior, en función del uso del edificio y del nivel sonoro continuo equivalente día, Ld de la zona donde se ubique el edificio. El hacer compatibles el cumplimiento de las exigencias de los dos Documentos Básicos anteriormente citados, origina algunas dificultades en los proyectos de edificación actuales. Los proyectistas tienen que recurrir en la mayoría de los casos a nuevos sistemas constructivos o duplicaciones de soluciones existentes, evitando la manipulación de los elementos de regulación de entrada de aire en las viviendas. El objetivo fundamental de la Tesis presentada es el estudio de los efectos que producen la colocación de sistemas de aireación permanente en el aislamiento acústico a ruido aéreo de las ventanas compactas. Se comprueba la influencia de cada uno de los componentes de la ventana compacta: perfiles, unidades de vidrio, sistema de apertura, cajón de persiana, persiana, aireadores, etc. en el aislamiento a ruido aéreo del sistema completo. Los ensayos acústicos se han realizado mediante dos métodos: conforme a la norma UNE-EN ISO 10140-2:2011 Medición en laboratorio del aislamiento acústico al ruido aéreo de los elementos de construcción y mediante intensimetría acústica acorde a la norma UNE-EN ISO 15186-1:2004 Medición del aislamiento acústico en los edificios y de los elementos de construcción utilizando intensidad sonora. Los resultados obtenidos podrán ser de gran utilidad para todos los profesionales que intervienen en el proceso edificatorio: arquitectos, ingenieros, instaladores, promotores, fabricantes de productos, etc., tanto en la obra nueva como en la rehabilitación. En un futuro, podrían incorporarse a los Catálogos y Documentos de Aplicación del CTE, así como a los nuevos programas informáticos de diseño y aislamiento acústico. Con el conocimiento adquirido y su aplicación, se contribuirá a la mejora de la calidad de una edificación más sostenible y eficiente. Se incrementará la productividad y la competitividad de los fabricantes de materiales y sistemas constructivos, aumentando el grado de satisfacción del usuario final con el consiguiente aumento de la calidad de vida de los ciudadanos. También se ampliará el conocimiento técnico de este tipo de sistemas y la compatibilidad entre las distintas exigencias marcadas por la normativa. ABSTRACT At present, the urban population growth, the increase of energy demand and the technological development in the last twenty years have led to a rethinking of the used building systems. As a result, new regulatory frameworks have been established, setting new goals of comfort and energy demand. In Spain, the Building Code, Código Técnico de la Edificación (CTE) (RD 314/2006 of March 17th) is the regulatory framework that establishes the requirements to be met by projecting, building, using, maintaining and preserving buildings, including its facilities in order to ensure the quality, safety and health of the user, always respecting the environment. To ensure compliance with the requirements of the CTE, different technical requirements Documentos básicos (DB) have been developed. Among them, are the DB-HR-Protection against noise and DB-HS-Health. In the DB-HS- part3, Indoor Air Quality, are set the conditions needed to be taken into consideration so that the building enclosures can be adequately ventilated, eliminating pollutants that occur regularly during normal use of the buildings, so that a sufficient airflow of outdoor is supplied and a removal and extraction of stale air pollutants is guaranteed. In section 3.1, General Terms of ventilation systems, is indicated that dwellings must have a general ventilation system where air can circulate from dry to wet enclosures. For this, dining rooms, bedrooms and living rooms should have air intake, being able to resolve this technical issue with various solutions. The DB-HR Protection against noise, provides sound insulation values of airborne sound transmission between a protected room and the outside, depending on the use of the building and the equivalent continuous sound level day, Ld, in the area where the building is located. Satisfying the requirements of the two requirements mentioned above causes some difficulties in current building project. Designers have to rely in most cases, to new construction elements or duplicate existing solutions, avoiding the manipulation of the air intakes elements. The main objective of this Thesis is the study of the effects of permanent intakes systems in the acoustic insulation against airborne noise transmission in compact windows. The influence of each of the components of the compact window is determined: frames, glass units, opening systems, shutter box, trickle vents, etc. in the airborne sound insulation of the entire system. The acoustic survey were performed using two methods: UNE-EN ISO 10140-2: 2011 Laboratory measurements of sound insulation of building elements and UNE-EN ISO 15186-1:2004 Measurement of sound insulation in buildings and of building elements using sound intensity. The obtained results may be useful for all professionals involved in the building process: architects, engineers, installers, developers, manufacturers, etc. in the new construction developments and in rehabilitation. In the future, it could be added to building catalogues and applications of the Spanish Building Code, as well as to the new design and sound insulation software. With the acquired knowledge and its application, there will be a contribution to improve the quality of a more sustainable and efficient construction. Productivity and competitiveness of manufacturers of building materials and components will improve, increasing the degree of satisfaction of the final user with a consequent increase in the quality of life of citizens. Technical knowledge of such systems and compatibility between the various requirements set by the legislation will also expand.
Resumo:
La edificación residencial existente en España y en Europa se encuentra abocada a una rehabilitación profunda para cumplir los objetivos marcados en la estrategia europea para el año 2050. Estos, para el sector de la edificación, se proponen una reducción del 90% de emisiones de gases de efecto invernadero (GEI) respecto a niveles del año 1990. Este plan a largo plazo establece hitos intermedios de control, con objetivos parciales para el año 2020 y 2030. El objetivo último es aprovechar el potencial de reducción de demanda energética del sector de la edificación, del cual la edificación residencial supone el 85% en España. Dentro de estos requerimientos, de reducción de demanda energética en la edificación, la ventilación en la edificación residencial se convierte en uno de los retos a resolver por su vinculación directa a la salud y el confort de los ocupantes de la misma, y al mismo tiempo su relación proporcional con la demanda energética que presenta el edificio asociada al acondicionamiento térmico. Gran parte de las pérdidas térmicas de la edificación residencial se producen por el aire de renovación y la infiltración de aire a través de la envolvente. La directiva europea de eficiencia energética de la edificación (EPBD), que establece las directrices necesarias para alcanzar los objetivos de este sector en cuanto a emisiones de CO2 y gases de efecto invernadero (GEI), contempla la ventilación con aire limpio como un requisito fundamental a tener en cuenta de cara a las nuevas construcciones y a la rehabilitación energética de los edificios existentes. El síndrome del edificio enfermo, un conjunto de molestias y síntomas asociados a la baja calidad del aire de edificios no residenciales que surgió a raíz de la crisis del petróleo de 1973, tuvo su origen en una ventilación deficiente y una renovación del aire interior insuficiente de estos edificios, producto del intento de ahorro en la factura energética. Teniendo en cuenta que, de media, pasamos un 58% de nuestro tiempo en las viviendas, es fundamental cuidar la calidad del aire interior y no empeorarla aplicando medidas de “eficiencia energética” con efectos no esperados. Para conseguir esto es fundamental conocer en profundidad cómo se produce la ventilación en la edificación en bloque en España en sus aspectos de calidad del aire interior y demanda energética asociada a la ventilación. El objetivo de esta tesis es establecer una metodología de caracterización y de optimización de las necesidades de ventilación para los espacios residenciales existentes en España que aúne el doble objetivo de garantizar la calidad ambiental y reducir la demanda energética de los mismos. La caracterización del parque edificatorio residencial español en cuanto a ventilación es concluyente: La vivienda en España se distribuye principalmente en tres periodos en los que se encuentran más del 80% del total de las viviendas construidas. El periodo anterior a las normas básicas de la edificación (NBE), de 1960 a 1980, el periodo desde 1980 al año 2005, con el mayor número total de viviendas construidas, guiado por la NTE ISV 75, y el periodo correspondiente a la edificación construida a partir del Código Técnico de la Edificación, en 2006, cuyo documento básico de condiciones de salubridad (DB HS3) es la primera norma de obligado cumplimiento en diseño y dimensionamiento de ventilación residencial en España. La selección de un modelo de bloque de viviendas de referencia, un valor medio y representativo, seleccionado de entre estos periodos, pero con cualidades que se extienden más allá de uno de ellos, nos permite realizar un intensivo análisis comparativo de las condiciones de calidad de aire interior y la demanda energética del mismo, aplicando las distintas configuraciones que presenta la ventilación en viviendas dependiendo del escenario o época constructiva (o normativa) en que esta fuera construida. Este análisis se lleva a cabo apoyándose en un doble enfoque: el modelado numérico de simulaciones y el análisis de datos experimentales, para comprobar y afinar los modelos y observar la situación real de las viviendas en estos dos aspectos. Gracias a las conclusiones del análisis previo, se define una estrategia de optimización de la ventilación basada fundamentalmente en dos medidas: 1) La introducción de un sistema de extracción mecánica y recuperación de calor que permita reducir la demanda energética debida a la renovación del aire y a la vez diluir los contaminantes interiores más eficazmente para mejorar, de esta forma, la calidad del ambiente interior. 2) La racionalización del horario de utilización de estos sistemas, no malgastando la energía en periodos de no ocupación, permitiendo una leve ventilación de fondo, debida a la infiltración, que no incida en pérdidas energéticas cuantiosas. A esta optimización, además de aplicar la metodología de análisis previo, en cuanto a demanda energética y calidad del aire, se aplica una valoración económica integradora y comparativa basada en el reglamento delegado EU244/2012 de coste óptimo (Cost Optimal Methodology). Los resultados principales de esta tesis son: • Un diagnóstico de la calidad del aire interior de la edificación residencial en España y su demanda energética asociada, imprescindible para lograr una rehabilitación energética profunda garantizando la calidad del aire interior. • Un indicador de la relación directa entre calidad de aire y demanda energética, para evaluar la adecuación de los sistemas de ventilación, respecto de las nuevas normativas de eficiencia energética y ventilación. • Una estrategia de optimización, que ofrece una alternativa de intervención, y la aplicación de un método de valoración que permite evaluar la amortización comparada de la instalación de los sistemas. ABSTRACT The housing building stock already built in Spain and Europe faces a deep renovation in the present and near future to accomplish with the objectives agreed in the European strategy for 2050. These objectives, for the building sector, are set in a 90% of Green House Gases (GHG) reduction compared to levels in 1990. This long‐term plan has set milestones to control the correct advance of achievement in 2020 and 2030. The main objective is to take advantage of the great potential to reduce energy demand from the building sector, in which housing represents 85% share in Spain. Among this reduction on building energy demand requirements, ventilation of dwellings becomes one of the challenges to solve as it’s directly connected to the indoor air quality (IAQ) and comfort conditions for the users, as well as proportional to the building energy demand on thermal conditioning. A big share of thermal losses in housing is caused by air renovation and infiltration through the envelope leaks. The European Directive on Building energy performance (EPBD), establishes the roots needed to reach the building sector objectives in terms of CO2 and GHG emissions. This directive sets the ventilation and renovation with clean air of the new and existing buildings as a fundamental requirement. The Sick Building Syndrome (SBS), an aggregation of symptoms and annoys associated to low air quality in non residential buildings, appeared as common after the 1973 oil crisis. It is originated in defective ventilation systems and deficient air renovation rates, as a consequence of trying to lower the energy bill. Accounting that we spend 58% of our time in dwellings, it becomes crucial to look after the indoor air quality and focus in not worsening it by applying “energy efficient” measures, with not expected side effects. To do so, it is primary to research in deep how the ventilation takes place in the housing blocks in Spain, in the aspects related to IAQ and ventilation energy demand. This thesis main objective is to establish a characterization and optimization methodology regarding the ventilation needs for existing housing in Spain, considering the twofold objective of guaranteeing the air quality as reducing the energy demand. The characterization of the existing housing building stock in Spain regarding ventilation is conclusive. More of 80% of the housing stock is distributed in 3 main periods: before the implementation of the firsts regulations on building comfort conditions (Normas Básicas de la Edificación), from 1960 to 1980; the period after the first recommendations on ventilation (NTE ISV 75) for housing were set, around 1980 until 2005 and; the period corresponding to the housing built after the existing mandatory regulation in terms of indoor sanity conditions and ventilation (Spanish Building Code, DB HS3) was set, in 2006. Selecting a representative blueprint of a housing block in Spain, which has medium characteristics not just within the 3 periods mention, but which qualities extent beyond the 3 of them, allows the next step, analyzing. This comparative and intense analyzing phase is focused on the air indoor conditions and the related energy demand, applying different configurations to the ventilation systems according to the different constructive or regulation period in which the building is built. This analysis is also twofold: 1) Numerical modeling with computer simulations and 2) experimental data collection from existing housing in real conditions to check and refine the models to be tested. Thanks to the analyzing phase conclusions, an optimization strategy on the ventilation of the housing stock is set, based on two actions to take: 1) To introduce a mechanical exhaust and intake ventilation system with heat recovery that allows reducing energy demand, as improves the capacity of the system to dilute the pollutant load. This way, the environmental quality is improved. 2) To optimize the schedule of the system use, avoids waste of energy in no occupancy periods, relying ventilation during this time in a light infiltration ventilation, intended not to become large and not causing extra energy losses. Apart from applying the previous analyzing methodology to the optimization strategy, regarding energy demand and air quality, a ROI valorization is performed, based on the cost optimal methodology (delegated regulation EU244/2012). The main results from the thesis are: • To obtain a through diagnose regarding air quality and energy demand for the existing housing stock in Spain, unavoidable to reach a energy deep retrofitting scheme with no air quality worsening. • To obtain a marker to relate air quality and energy demand and evaluate adequateness of ventilation systems, for the new regulations to come. • To establish an optimization strategy to improve both air quality and energy demand, applying a compared valorization methodology to obtain the Return On Investment (ROI).
Resumo:
Underground hardrock mining can be very energy intensive and in large part this can be attributed to the power consumption of underground ventilation systems. In general, the power consumed by a mine’s ventilation system and its overall scale are closely related to the amount of diesel power in operation. This is because diesel exhaust is a major source of underground air pollution, including diesel particulate matter (DPM), NO2 and heat, and because regulations tie air volumes to diesel engines. Furthermore, assuming the size of airways remains constant, the power consumption of the main system increases exponentially with the volume of air supplied to the mine. Therefore large diesel fleets lead to increased energy consumption and can also necessitate large capital expenditures on ventilation infrastructure in order to manage power requirements. Meeting ventilation requirements for equipment in a heading can result in a similar scenario with the biggest pieces leading to higher energy consumption and potentially necessitating larger ventilation tubing and taller drifts. Depending on the climate where the mine is located, large volumes of air can have a third impact on ventilation costs if heating or cooling the air is necessary. Annual heating and cooling costs, as well as the cost of the associated infrastructure, are directly related to the volume of air sent underground. This thesis considers electric mining equipment as a means for reducing the intensity and cost of energy consumption at underground, hardrock mines. Potentially, electric equipment could greatly reduce the volume of air needed to ventilate an entire mine as well as individual headings because they do not emit many of the contaminants found in diesel exhaust and because regulations do not connect air volumes to electric motors. Because of the exponential relationship between power consumption and air volumes, this could greatly reduce the amount of power required for mine ventilation as well as the capital cost of ventilation infrastructure. As heating and cooling costs are also directly linked to air volumes, the cost and energy intensity of heating and cooling the air would also be significantly reduced. A further incentive is that powering equipment from the grid is substantially cheaper than fuelling them with diesel and can also produce far fewer GHGs. Therefore, by eliminating diesel from the underground workers will enjoy safer working conditions and operators and society at large will gain from a smaller impact on the environment. Despite their significant potential, in order to produce a credible economic assessment of electric mining equipment their impact on underground systems must be understood and considered in their evaluation. Accordingly, a good deal of this thesis reviews technical considerations related to the use of electric mining equipment, especially ones that impact the economics of their implementation. The goal of this thesis will then be to present the economic potential of implementing the equipment, as well as to outline the key inputs which are necessary to support an evaluation and to provide a model and an approach which can be used by others if the relevant information is available and acceptable assumptions can be made.
Resumo:
The prediction of convective heat transfer in enclosures under high ventilative flow rates is primarily of interest for building design and simulation purposes. Current models are based on experiments performed forty years ago with flat plates under natural convection conditions.
Resumo:
År 2006 införde Boverket, som lyder under regeringen krav för specifik energianvändning (kWh/m2år) för byggnader i syfte att minska energianvändningen för bostäder och lokaler. För att följa Boverkets krav för specifik energianvändning är det därför relevant att bygga mer energieffektiva byggnader. Naturmuseet Vänern är en byggnad i Karlstad som befinner sig vid Vänern. Byggnaden är omgiven av en naturskön miljö och dess verksamhet är huvudsakligen ett museum. Som helhet är Naturmuseet Vänern högt i tak och har stora fönsterytor vilket leder till att byggnaden behöver kylas på grund av den stora mängden solinstrålning. För att hålla sig till en låg specifik energianvändning är det därför relevant att hitta ett hållbart kylsystem. För att en byggnad ska bli energieffektiv i ett klimat såsom det i Sverige krävs ett byggnadsmaterial med lågt U-värde samt väl anpassade systemlösningar för värme, ventilation och kyla. Utifrån datorprogrammet VIP-Energy har en energianalys gjorts för Naturmuseet Vänern, vilket legat som grund för byggnadens utformning samt valet av byggnadsmaterial och kylsystem. Resultatet har utöver hur byggandes klimatskal ska se ut även landat i systemhandlingar i form av ritningar, driftstrategi och materialspecifikation för kylsystemet. Den lägsta specifika energianvändningen för Naturmuseet Vänern är 37 kWh/m2år, vilket fås då bergkyla väljs som kylsystem.
Resumo:
Indoor air quality is a critical factor in the classroom due to high people concentration in a unique space. Indoor air pollutant might increase the chance of both long and short-term health problems among students and staff, reduce the productivity of teachers and degrade the student’s learning environment and comfort. Adequate air distribution strategies may reduce risk of infection in classroom. So, the purpose of air distribution systems in a classroom is not only to maximize conditions for thermal comfort, but also to remove indoor contaminants. Natural ventilation has the potential to play a significant role in achieving improvements in IAQ. The present study compares the risk of airborne infection between Natural Ventilation (opening windows and doors) and a Split-System Air Conditioner in a university classroom. The Wells-Riley model was used to predict the risk of indoor airborne transmission of infectious diseases such as influenza, measles and tuberculosis. For each case, the air exchange rate was measured using a CO2 tracer gas technique. It was found that opening windows and doors provided an air exchange rate of 2.3 air changes/hour (ACH), while with the Split System it was 0.6 ACH. The risk of airborne infection ranged between 4.24 to 30.86 % when using the Natural Ventilation and between 8.99 to 43.19% when using the Split System. The difference of airborne infection risk between the Split System and the Natural Ventilation ranged from 47 to 56%. Opening windows and doors maximize Natural Ventilation so that the risk of airborne contagion is much lower than with Split System.
Resumo:
Background: Multiple studies have identified single variables or composite scores that help risk stratify patients at the time of acute lung injury (ALI) diagnosis. However, few studies have addressed the important question of how changes in pulmonary physiologic variables might predict mortality in patients during the subacute or chronic phases of ALI. We studied pulmonary physiologic variables, including respiratory system compliance, P/F ratio and oxygenation index, in a cohort of patients with ALI who survived more than 6 days of mechanical ventilation to see if changes in these variables were predictive of death and whether they are informative about the pathophysiology of subacute ALI.