938 resultados para urine specimen collection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An adsorptive stripping voltammetric procedure for the determination of the antidepressant venlafaxine in urine using a mercury film microelectrode wasdeveloped. The method is based on controlled adsorptive accumulation of the drug at the potential of 1.00V (vs. Ag/AgCl) in the presence of 1.25 x10 -2 molL- 1 borate buffer (pH 8.7). Urine samples were analyzed directly after performing a ten-fold dilution with the supporting electrolyte but without other pretreatment. The limit of detection obtained for a 30 s collection time was 0.693x 10- 6 mol L -1. Recovery experimentsgave good results at the 10 -6 mol L- 1 level (bias less 5% were obtained).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water is a limited resource for which demand is growing. Contaminated water from inadequate wastewater treatment provides one of the greatest health challenges as it restricts development and increases poverty in emerging and developing countries. Therefore, the connection between wastewater and human health is linked to access to sanitation and to human waste disposal. Adequate sanitation is expected to create a barrier between disposed human excreta and sources of drinking water. Different approaches to wastewater management are required for different geographical regions and different stages of economic governance depending on the capacity to manage wastewater. Effective wastewater management can contribute to overcome the challenges of water scarcity. Separate collection of human urine at its source is one promising approach that strongly reduces the economic and load demands on wastewater treatment plants (WWTP). Treatment of source-separated urine appears as a sanitation system that is affordable, produces a valuable fertiliser, reduces pollution of water resources and promotes health. However, the technical realisation of urine separation still faces challenges. Biological hydrolysis of urea causes a strong increase of ammonia and pH. Under these conditions ammonia volatilises which can cause odour problems and significant nitrogen losses. The above problems can be avoided by urine stabilisation. Biological nitrification is a suitable process for stabilisation of urine. Urine is a highly concentrated nutrient solution which can lead to strong inhibition effects during bacterial nitrification. This can further lead to process instabilities. The major cause of instability is accumulation of the inhibitory intermediate compound nitrite, which could lead to process breakdown. Enhanced on-line nitrite monitoring can be applied in biological source-separated urine nitrification reactors as a sustainable and efficient way to improve the reactor performance, avoiding reactor failures and eventual loss of biological activity. Spectrophotometry appears as a promising candidate for the development and application of on-line nitrite monitoring. Spectroscopic methods together with chemometrics are presented in this work as a powerful tool for estimation of nitrite concentrations. Principal component regression (PCR) is applied for the estimation of nitrite concentrations using an immersible UV sensor and off-line spectra acquisition. The effect of particles and the effect of saturation, respectively, on the UV absorbance spectra are investigated. The analysis allows to conclude that (i) saturation has a substantial effect on nitrite estimation; (ii) particles appear to have less impact on nitrite estimation. In addition, improper mixing together with instabilities in the urine nitrification process appears to significantly reduce the performance of the estimation model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Big sports events like the 2008 European Football Championship are a challenge for anti-doping activities, particularly when the sports event is hosted by two different countries and there are two laboratories accredited by the World Anti-Doping Agency. This challenges the logistics of sample collection as well as the chemical analyses, which must be carried out timeously. The following paper discusses the handling of whereabouts information for each athlete and the therapeutic use exemption system, experiences in sample collection and transportation of blood and urine samples, and the results of the chemical analysis in two different accredited laboratories. An overview of the analytical results of blood profiling and growth hormone testing in comparison with the distribution of the normal population is also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND. To use spectra acquired by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) from pre- and post-digital rectal examination (DRE) urine samples to search for discriminating peaks that can adequately distinguish between benign and malignant prostate conditions, and identify the peaks’ underlying biomolecules. METHODS. Twenty-five participants with prostate cancer (PCa) and 27 participants with a variety of benign prostatic conditions as confirmed by a 10-core tissue biopsy were included. Pre- and post-DRE urine samples were prepared for MALDI MS profiling using an automated clean-up procedure. Following mass spectra collection and processing, peak mass and intensity were extracted and subjected to statistical analysis to identify peaks capable of distinguishing between benign and cancer. Logistic regression was used to combine markers to create a sensitive and specific test. RESULTS. A peak at m/z 10,760 was identified as b-microseminoprotein (b-MSMB) and found to be statistically lower in urine from PCa participants using the peak’s average areas. By combining serum prostate-specific antigen (PSA) levels with MALDI MS-measured b-MSMB levels, optimum threshold values obtained from Receiver Operator characteristics curves gave an increased sensitivity of 96% at a specificity of 26%. CONCLUSIONS. These results demonstrate that with a simple sample clean-up followed by MALDI MS profiling, significant differences of MSMB abundance were found in post-DRE urine samples. In combination with PSA serum levels, obtained from a classic clinical assay led to high classification accuracy for PCa in the studied sample set. Our results need to be validated in a larger multicenter prospective randomized clinical trial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human papillomavirus is a DNA virus that includes 118 genotypes. HPV16 is responsible for 80% of cervical cancer in women. Men are important reservoirs and major transmitters of HPV to their partners. The aim of this study was to detect HPV DNA and to determine the prevalence of HPV types 6, 11, 16, and 18 in urine samples of men infected with HIV-1. This study included 223 patients infected with HIV-1 from the Center of Reference on HIV/AIDS (CRT-SP) and an outpatient clinic of HIV. Urine samples were collected and after DNA extraction real-time PCR was performed for detection of HPV DNA. Positive samples were then tested by conventional PCR using type-specific primers for the four HPV types. A total of 223 men infected with HIV-1 were tested, 81% of whom were on HAART. Four (5.8%) were positive for HPV6, 18 (26.1%) were positive for HPV11, 22 (31.9%) were positive for HPV16 and five (7.2%) were positive for HPV18 by conventional PCR. Twenty (29%) patients had other HPV types and five patients (1.5%) had multiple types. The mean T CD4+cells count was 517 and 441 cells/mm(3) (P=0.30), in HPV negative and positive men, respectively. The HIV viral load was higher in the HPV negative group than for in the men with HPV (P=0.0002). A 30.9% prevalence of HPV was found in asymptomatic urine samples of men infected with HIV-1. This study suggests that urine may be a useful specimen for HPV screening. J. Med. Virol 81:2007-2011, 2009. (C) 2009 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recovery and stability of DNA for the detection and genotyping of HPV in UCM-containing specimens, after exposure to denaturing reagents and stored for up to 2 years were evaluated. Samples were collected from 60 women who had cervical cytology specimens harboring cervical intraepithelial neoplasia (CIN) 2 or 3. All samples were stored in UCM and had been frozen at -20 degrees C following the addition of the denaturing reagent (sodium hydroxide) and the removal of the aliquot required for Hybrid Capture 2 testing for the identification of HPV DNA. The samples had been stored for 6, 12 and 24 months (20 samples for each storage time). HPV DNA extraction was performed according to a protocol designed specifically and the presence and quality of DNA was confirmed by human P-globin detection using the consensus primers G73 and G74. HPV DNA was amplified using the consensus primers PGMY09 and PGMY11, and reverse line-blot hybridization was used to detect type-specific amplicons for 37 HPV types. The DNA extracted from the denatured specimen was recovered in 57/60 (95%) of the samples. HPV DNA was detected in 56/57 (98%) of the recovered samples. Twenty-six of the 56 samples recovered (48%) were genotyped successfully. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Food base excess (BE, mEq/kg) can be calculated from the diet macroelements, together with either the sulfur amino acids methionine and cysteine (BEaa) or total sulfur (BEs) concentrations. The present study compared the use of sulfur or methionine and cysteine for calculating the food BE (experiment 1) and investigated the influence of food BE on blood gas analysis and the urine pH of cats, and proposes a prediction equation to estimate the urine pH of cats fed kibble diets based on the calculated food BE (experiments 2 and 3). In experiment 1, nine healthy, adult cats were used in a change-over design and fed with nine commercial dry cat foods. The cats were housed in metabolism cages over seven days for adaptation and three days for total urine collection. All of the urine produced over 24h was pooled by cat and diet. The cats' acid-base status was assessed through blood gas analysis after 10 days of diet consumption. A mean difference of -115mEq/kg between BEs and BEaa was observed, which could be explained by a greater concentration of sulfur in the whole diet than in methionine and cysteine. Urine pH presented a stronger correlation with food BEs (R2=0.95; P<0.001) than with food BEaa (R2=0.86; P<0.001). Experiment 2 included 30 kibble diets, and each diet was tested in six cats. The food BEs varied between -180 and +307mEq/kg, and the urine pH of the cats varied between 5.60 and 7.74. A significant correlation was found between the measured urine pH and the food BEs (urinary pH=6.269+[0.0036×BEs]+[0.000003×BEs2]; R2=0.91; P<0.001). In experiment 3, eight kibble diets were tested (food BEs between -187mEq/kg and +381mEq/kg) to validate the equation proposed in experiment 2 and to compare the obtained results with previously published formulae. The results of the proposed formula presented a high concordance correlation coefficient (0.942) and high accuracy (0.979) with the measured values, and the estimates of urine pH did not differ from the values obtained in cats (P>0.05). The cats' venous blood pH, bicarbonate, and blood BE were correlated with food BEs (P<0.001); the consumption of diets with low food BEs induced a reduction in these parameters. In conclusion, food macroelement composition has a strong influence on cats' acid-base equilibrium and food BEs calculation is a useful tool to formulate and balance kibble diets for felines. © 2013 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The examination of urine in children can be very complex, due to the difficulty to obtain clean urine specimens in infants and toddlers. Clean catch is an easy system to obtain urine but patience is needed. Transurethral catheterization or suprapubic aspiration is useful in infants and toddlers with sign of pyelonephritis. Urine bag specimens are not useful in the diagnosis of urinary tract infection because of the high rate of false positive cultures. The 24 hours urine collection is frequently replaced by a spot urine and the ratio of the measured substances with the urine creatinine are calculated. Urine microscopy is needed for the evaluation of pathological results in the dipstick testing: confirm that red urine is due to haematuria by demonstration of red blood cells on urine microscopy, dysmorphic cells and red-cell casts are pathognomonic of glomerular bleeding, white-cell casts signify glomerular inflammation and bacteria are easily seen in unstained urine. A urine culture is pathologic if the colony count exceeds 10(4) in the transurethral catheterization or clean void. In the suprapubic aspiration is any number of colony pathologic. Urate crystals in the urine of infants may cause a pink discoloration to nappies. Urine screenings are not very useful and should be performed only at the age of 5 years or by sexual-active adolescents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Proteinuria (PTU) is an important marker for the development and progression of renal disease, cardiovascular disease and death, but there is limited information about the prevalence and factors associated with confirmed PTU in predominantly white European HIV+ persons, especially in those with an estimated glomerular filtration rate (eGFR) of 60 mL/min/1.73 m(2). PATIENTS AND METHODS Baseline was defined as the first of two consecutive dipstick urine protein (DPU) measurements during prospective follow-up >1/6/2011 (when systematic data collection began). PTU was defined as two consecutive DUP >1+ (>30 mg/dL) >3 months apart; persons with eGFR <60 at either DPU measurement were excluded. Logistic regression investigated factors associated with PTU. RESULTS A total of 1,640 persons were included, participants were mainly white (n=1,517, 92.5%), male (n=1296, 79.0%) and men having sex with men (n=809; 49.3%). Median age at baseline was 45 (IQR 37-52 years), and CD4 was 570 (IQR 406-760/mm(3)). The median baseline date was 2/12 (IQR 11/11-6/12), and median eGFR was 99 (IQR 88-109 mL/min/1.73 m(2)). Sixty-nine persons had PTU (4.2%, 95% CI 3.2-4.7%). Persons with diabetes had increased odds of PTU, as were those with a prior non-AIDS (1) or AIDS event and those with prior exposure to indinavir. Among females, those with a normal eGFR (>90) and those with prior abacavir use had lower odds of PTU (Figure 1). CONCLUSIONS One in 25 persons with eGFR>60 had confirmed proteinuria at baseline. Factors associated with PTU were similar to those associated with CKD. The lack of association with antiretrovirals, particularly tenofovir, may be due to the cross-sectional design of this study, and additional follow-up is required to address progression to PTU in those without PTU at baseline. It may also suggest other markers are needed to capture the deteriorating renal function associated with antiretrovirals may be needed at higher eGFRs. Our findings suggest PTU is an early marker for impaired renal function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To determine the accuracy of the urine protein:creatinine ratio (pr:cr) in predicting 300 mg of protein in 24-hour urine collection in pregnant patients with suspected preeclampsia. ^ Methods. A systematic review was performed. Articles were identified through electronic databases and the relevant citations were hand searching of textbooks and review articles. Included studies evaluated patients for suspected preeclampsia with a 24-hour urine sample and a pr:cr. Only English language articles were included. The studies that had patients with chronic illness such as chronic hypertension, diabetes mellitus or renal impairment were excluded from the review. Two researchers extracted accuracy data for pr:cr relative to a gold standard of 300 mg of protein in 24-hour sample as well as population and study characteristics. The data was analyzed and summarized in tabular and graphical form. ^ Results. Sixteen studies were identified and only three studies met our inclusion criteria with 510 total patients. The studies evaluated different cut-points for positivity of pr:cr from 130 mg/g to 700 mg/g. Sensitivities and specificities for pr:cr of 130mg/g -150 mg/g were 90-93% and 33-65%, respectively; for a pr:cr of 300 mg/g were 81-95% and 52-80%, respectively; for a pr:cr of 600-700mg/g were 85-87% and 96-97%, respectively. ^ Conclusion. The value of a random pr:cr to exclude pre-eclampsia is limited because even low levels of pr:cr (130-150 mg/g) may miss up to 10% of patients with significant proteinuria. A pr:cr of more than 600 mg/g may obviate a 24-hour collection.^