959 resultados para total hip prostheses
Resumo:
Low-molecular-weight heparins have become the predominant choice for deep venous thrombosis prophylaxis and treatment. However, their use may cause bleeding complications. Intrahepatic bleeding is exceptional and only very few cases have been described. The authors present a unique case of fatal intrahepatic hematoma complicating nadroparin use in a 65-year-old woman with a hepatic cyst who was admitted to hospital for unilateral total hip arthroplasty. At autopsy, hemoperitoneum (2,000 ml of blood and clots) was evident. A ruptured sub-capsular hematoma involving the right lobe of the liver was observed. The hemorrhage within the cyst induced by the nadroparin use was likely responsible for the subsequent hepatic hematoma, liver rupture, and death. This case highlights the need for pathologists and surgeons to be aware of the possibility of intrahepatic hematoma in patients who have received low-molecular-weight heparins, undergone major surgery and present postoperative hemodynamic instability, especially in those with preoperative diagnosis of hepatic cyst.
Resumo:
PURPOSE: The aim of this study was to determine outcomes of total hip replacement (THR) with the Lemania cemented femoral stem. METHODS: A total of 78 THR patients were followed and compared to 17 "fit", healthy, elderly and 72 "frail" elderly subjects without THR, using clinical outcome measures and a portable, in-field gait analysis device at five and ten years follow-up. RESULTS: Forty-one patients (53%), mean age 83.4 years, available at ten years follow-up, reported very good to excellent satisfaction. Mean Harris Hip and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were 81.2 and 10.5 points, respectively, with excellent radiological preservation of proximal femur bone stock. Spatial and temporal gait parameters were close to the fit group and better than the frail group. CONCLUSIONS: Lemania THR demonstrated very good, stable clinical and radiological results at ten years in an older patient group, comparable to other cemented systems for primary THR. Gait analysis confirmed good walking performance in a real-life environment.
Resumo:
We conducted this study to determine the relative influence of various mechanical and patient-related factors on the incidence of dislocation after primary total hip asthroplasty (THA). Of 2,023 THAs, 21 patients who had at least 1 dislocation were compared with a control group of 21 patients without dislocation, matched for age, gender, pathology, and year of surgery. Implant positioning, seniority of the surgeon, American Society of Anesthesiologists (ASA) score, and diminished motor coordination were recorded. Data analysis included univariate and multivariate methods. The dislocation risk was 6.9 times higher if total anteversion was not between 40 degrees and 60 degrees and 10 times higher in patients with high ASA scores. Surgeons should pay attention to total anteversion (cup and stem) of THA. The ASA score should be part of the preoperative assessment of the dislocation risk.
Resumo:
The purpose of this study is to clinically validate a new two-dimensional preoperative planning software for cementless total hip arthroplasty (THA). Manual and two-dimensional computer-assisted planning were compared by an independent observer for each of the 30 patients with osteoarthritis who underwent THA. This study showed that there were no statistical differences between the results of both preoperative plans in terms of stem size and neck length (<1 size) and hip rotation center position (<5 mm). Two-dimensional computer-assisted preoperative planning provided successful results comparable to those using the manual procedure, thereby allowing the surgeon to simulate various stem designs easily.
Resumo:
BACKGROUND: The literature suggests that intraoperative fractures of the greater trochanter and the metaphysis are increased with uncemented stems and the direct anterior approach. This study aims to determine the incidence and assess the functional and radiological outcome after such fractures. METHODS: 484 consecutive total hip replacements (THR) (64 ± 12 years) were analyzed. We treated trochanteric fractures conservatively without any further denuding, and secured metaphyseal fissures with cerclages. Postoperative X-rays and at the latest follow-up were compared to assess secondary fracture displacement and stem subsidence. Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores after 1 year were analyzed. For each patient sustaining a fracture, two patients without fractures were matched in terms of age, body mass index and gender. RESULTS: 13 (2.7 %, 5 male, 68 ± 9 years) patients with intraoperative fractures of the greater trochanter (n = 8) or the metaphysis (n = 5) were analyzed. Consolidation was observed in 7/8 patients sustaining a trochanteric fracture while secondary displacement of the fragment occurred in one case. Stem subsidence was observed in 2/5 cases (5 and 7 mm). Patients who sustained a fracture showed a trend towards poorer WOMAC scores at 1 year postoperatively, compared to patients without fractures. A significantly increased joint stiffness was also observed. CONCLUSION: The intraoperative fracture risk in this series of THR through a direct anterior approach was 2.7 %. Trochanteric fractures do heal without primary fixation. Metaphyseal fractures heal well if immediately stabilized with a cerclage.
Resumo:
Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.
Resumo:
BACKGROUND: Although the importance of accurate femoral reconstruction to achieve a good functional outcome is well documented, quantitative data on the effects of a displacement of the femoral center of rotation on moment arms are scarce. The purpose of this study was to calculate moment arms after nonanatomical femoral reconstruction. METHODS: Finite element models of 15 patients including the pelvis, the femur, and the gluteal muscles were developed. Moment arms were calculated within the native anatomy and compared to distinct displacement of the femoral center of rotation (leg lengthening of 10 mm, loss of femoral offset of 20%, anteversion ±10°, and fixed anteversion at 15°). Calculations were performed within the range of motion observed during a normal gait cycle. RESULTS: Although with all evaluated displacements of the femoral center of rotation, the abductor moment arm remained positive, some fibers initially contributing to extension became antagonists (flexors) and vice versa. A loss of 20% of femoral offset led to an average decrease of 15% of abductor moment. Femoral lengthening and changes in femoral anteversion (±10°, fixed at 15°) led to minimal changes in abductor moment arms (maximum change of 5%). Native femoral anteversion correlated with the changes in moment arms induced by the 5 variations of reconstruction. CONCLUSION: Accurate reconstruction of offset is important to maintaining abductor moment arms, while changes of femoral rotation had minimal effects. Patients with larger native femoral anteversion appear to be more susceptible to femoral head displacements.
Resumo:
Hip resurfacing arthroplasty (HRA) and large head metal-on-metal total arthroplasty (LDH MoM THA) gained popularity during the last decade. Adverse reaction to metal debris (ARMD) is a unique complication of metal bearings. ARMD is a complex reaction caused by metal debris from metal-on- metal bearing surfaces and from trunnion corrosion of modular junctions. We analyzed survivorship of 8059 LDH MoM THAs based on data of the Finnish Arthroplasty Register. We found relatively high short-term survivorship for some LDH MoM THAs, but there were remarkable differences between the devices studied. After some alarming reports of failing MoM THAs, we studied the first 80 patients who had received a ReCap-M2a-Magnum implant at our institution and evaluated the prevalence of ARMD. We found a high prevalence of pseudotumors, and, because of this, we discontinued the use of MoM bearings and followed up all patients with a MoM THA. Bone loss due infection, osteolysis or fracture poses a great challenge for reconstructive and fracture surgery. Onlay allografting for both revision and fracture surgery provides mechanical stability and increases bone stock. Bone loss and implant stability must be assessed preoperatively and adequately classified; this provides guidelines for the operative treatment of periprosthetic fractures and revision THA. In our studies on structural allografts union rates were high, although the rates of infections and dislocations were marked. In summary, early results of the use of LDH MoM devices were encouraging. However, the survival of the LDH MoMs varied. The prevalence of adverse reaction to metal debris was high after application of the ReCap-Magnum THA. New implants should be introduced carefully and under close surveillance by University clinics and arthroplasty registers.
Resumo:
The puqjose of this study was to examine the manner in which an inviting approach to a preoperative teaching and learning educational experience influenced the perception and subsequent recovery of clients who were awaiting total hip and total knee replacement surgery. An in-depth review of the internal and external factors that shape client perceptions was undertaken in this study. In addition, this study also explored whether or not the Prehab Program was preparing clients physically, socially, and psychologically for surgery. Data for this qualitative case study research were collected through preoperative interviews with 4 participants awaiting total hip replacement surgery and 1 participant awaiting total knee replacement surgery. Four postoperative interviews were conducted with the participants who had received total hip replacement surgery. The occupational therapist and physical therapist who were the coleaders of the Prehab Program at the time of this study were also interviewed. The results of this study suggest that while individuals may receive similar educational experiences, their perceptions of the manner in which they benefited from these experiences varied. This is illustrated in the research findings, which concluded that while clients benefited physically from the inviting approach used during the practical teaching session, not all clients perceived the psychological benefits of this practice session, especially clients with preexisting high levels of anxiety. In addition to increasing the understanding of the internal as well as external factors that influence the perceptions of clients, this study has also served as an opportunity for reflection on practice for the Prehab therapists and other healthcare educators.
Resumo:
Background: This prospective experimental study evaluated the surgical procedure and results of modular hybrid total hip arthroplasty in dogs.Methods: Ten skeletally mature healthy mongrel dogs with weights varying between 19 and 27 kg were used. Cemented modular femoral stems and uncemented porous-coated acetabular cups were employed. Clinical and radiographic evaluations were performed before surgery and at 30, 60, 90, 120, 180 and 360 days post-operation.Results: Excellent weight bearing was noticed in the operated limb in seven dogs. Dislocation followed by loosening of the prosthesis was noticed in two dogs, which were therefore properly treated with a femoral head osteotomy. Femoral fracture occurred in one dog, which was promptly treated with full implant removal and femoral osteosynthesis.Conclusions: The canine modular hybrid total hip arthroplasty provided excellent functionality of the operated limb.
Resumo:
The purpose of this Study was to evaluate Soft tissue response to rnaxillo-mandibular counter-clockwise rotation, with TMJ reconstruction and mandibular advancement using TMJ Concepts (R) total joint prostheses, and maxillary osteotomies in 44 females. All patients were operated at Baylor University Medical Center, Dallas TX, USA, by one Surgeon (Wolford). Eighteen patients had genioplasties with either porous block hydroxyapatite or hard tissue replacement implants (Group 2) 26 had no genioplasty (Group 1). Surgically, the maxilla moved forward and upward by counter-clockwise maxillo-mandibular rotation with greater horizontal movement in Group 2. Vertically, both groups showed diversity of maxillo-mandibular mean movement. Group I showed a consistent 1:0.97 ratio of hard to soft tissue advancement at pogonion; Group 2 results were less consistent, with ratios between 1:0.84 and 1:1.02. Horizontal changes in upper lip morphology after maxillary advancement/impaction, VY closure, and alar base cinch sutures showed greater movement in both groups, than observed in hard tissue. Counter-clockwise rotation of the maxillo-mandibular complex using TMJ Concepts total joint prostheses resulted in similar soft tissue response as previously reported for traditional maxillo-mandibular advancement without counter-clockwise rotation of the occlusal plane. The association of chin implants, in the present sample, showed higher variability of soft tissue response.