994 resultados para thickness change


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To investigate whether diurnal variation occurs in retinal thickness measures derived from spectral domain optical coherence tomography (SD-OCT). Methods. Twelve healthy adult subjects had retinal thickness measured with SD-OCT every 2 h over a 10 h period. At each measurement session, three average B-scan images were derived from a series of multiple B-scans (each from a 5 mm horizontal raster scan along the fovea, containing 1500 A-scans/B-scan) and analyzed to determine the thickness of the total retina, as well as the thickness of the outer retinal layers. Average thickness values were calculated at the foveal center, at the 0.5 mm diameter foveal region, and for the temporal parafovea (1.5 mm from foveal center) and nasal parafovea (1.5 mm from foveal center). Results. Total retinal thickness did not exhibit significant diurnal variation in any of the considered retinal regions (p > 0.05). Evidence of significant diurnal variation was found in the thickness of the outer retinal layers (p < 0.05), with the most prominent changes observed in the photoreceptor layers at the foveal center. The photoreceptor inner and outer segment layer thickness exhibited mean amplitude (peak to trough) of daily change of 7 ± 3 μm at the foveal center. The peak in thickness was typically observed at the third measurement session (mean measurement time, 13:06). Conclusions. The total retinal thickness measured with SD-OCT does not exhibit evidence of significant variation over the course of the day. However, small but significant diurnal variation occurs in the thickness of the foveal outer retinal layers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The time course of elongation and recovery of axial length associated with a 30 minute accommodative task was studied using optical low coherence reflectometry in a population of young adult myopic (n = 37) and emmetropic (n = 22) subjects. Ten of the 59 subjects were excluded from analysis either due to inconsistent accommodative response, or incomplete anterior biometry data. Those subjects with valid data (n = 49) were found to exhibit a significant axial elongation immediately following the commencement of a 30 minute, 4 D accommodation task, which was sustained for the duration of the task, and ¬was evident to a lesser extent immediately following task cessation. During the accommodation task, on average, the myopic subjects exhibited 22 ± 34 µm, and the emmetropic subjects 6 ± 22 µm of axial elongation, however the differences in axial elongation between the myopic and emmetropic subjects were not statistically significant (p = 0.136). Immediately following the completion of the task, the myopic subjects still exhibited an axial elongation (mean magnitude 12 ± 28 µm), that was significantly greater (p < 0.05) than the changes in axial length observed in the emmetropic subjects (mean change -3 ± 16 µm). Axial length had returned to baseline levels 10 minutes after completion of the accommodation task. The time for recovery from accommodation-induced axial elongation was greater in myopes, which may reflect differences in the biomechanical properties of the globe associated with refractive error. Changes in subfoveal choroidal thickness were able to be measured in 37 of the 59 subjects, and a small amount of choroidal thinning was observed during the accommodation task that was statistically significant in the myopic subjects (p < 0.05). These subfoveal choroidal changes could account for some but not all of the increased axial length during accommodation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent research indicates that brief periods (60 minutes) of monocular defocus lead to small but significant changes in human axial length. However, the effects of longer periods of defocus on the axial length of human eyes are unknown. We examined the influence of a 12 hour period of monocular myopic defocus on the natural daily variations occurring in axial length and choroidal thickness of young adult emmetropes. A series of axial length and choroidal thickness measurements (collected at ~3 hourly intervals, with the first measurement at ~9 am and the final measurement at ~9 pm) were obtained for 13 emmetropic young adults over three consecutive days. The natural daily rhythms (Day 1, baseline day, no defocus), the daily rhythms with monocular myopic defocus (Day 2, defocus day, +1.50 DS spectacle lens over the right eye), and the recovery from any defocus induced changes (Day 3, recovery day, no defocus) were all examined. Significant variations over the course of the day were observed in both axial length and choroidal thickness on each of the three measurement days (p<0.0001). The magnitude and timing of the daily variations in axial length and choroidal thickness were significantly altered with the monocular myopic defocus on day 2 (p<0.0001). Following the introduction of monocular myopic defocus, the daily peak in axial length occurred approximately 6 hours later, and the peak in choroidal thickness approximately 8.5 hours earlier in the day compared to days 1 and 3 (with no defocus). The mean amplitude (peak to trough) of change in axial length (0.030 ± 0.012 on day 1, 0.020 ± 0.010 on day 2 and 0.033 ± 0.012 mm on day 3) and choroidal thickness (0.030 ± 0.007 on day 1, 0.022 ± 0.006 on day 2 and 0.027 ± 0.009 mm on day 3) were also significantly different between the three days (both p<0.05). The introduction of monocular myopic defocus disrupts the daily variations in axial length and choroidal thickness of human eyes (in terms of both amplitude and timing) that return to normal the following day after removal of the defocus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat, Acticoat combined with Mepitel and Mepilex Ag dressings for acute, paediatric partial thickness burns. METHODS/DESIGN: Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. DISCUSSION: The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12613000105741.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The human choroid is capable of rapidly changing its thickness in response to a variety of stimuli. However little is known about the role of the autonomic nervous system in the regulation of the thickness of the choroid. Therefore, we investigated the effect of topical parasympatholytic and sympathomimetic agents upon the choroidal thickness and ocular biometrics of young healthy adult subjects. Fourteen subjects (mean age 27.9 ± 4 years) participated in this randomized, single-masked, placebo-controlled study. Each subject had measurements of choroidal thickness (ChT) and ocular biometrics of their right eye taken before, and then 30 and 60 min following the administration of topical pharmacological agents. Three different drugs: 2% homatropine hydrobromide, 2.5% phenylephrine hydrochloride and a placebo (0.3% hydroxypropyl methylcellulose) were tested in all subjects; each on different days (at the same time of the day) in randomized order. Participants were masked to the pharmacological agent being used at each testing session. The instillation of 2% homatropine resulted in a small but significant increase in subfoveal ChT at 30 and 60 min after drug instillation (mean change 7 ± 3 μm and 14 ± 2 μm respectively; both p < 0.0001). The parafoveal choroid also exhibited a similar magnitude, significant increase in thickness with time after 2% homatropine (p < 0.001), with a mean change of 7 ± 0.3 μm and 13 ± 1 μm (in the region located 0.5 mm from the fovea center), 6 ± 1 μm and 12.5 ± 1 μm (1 mm from the fovea center) and 6 ± 2 μm and 12 ± 2 μm (1.5 mm from the fovea center) after 30 and 60 min respectively. Axial length decreased significantly 60 min after homatropine (p < 0.01). There were also significant changes in lens thickness (LT) and anterior chamber depth (ACD) (p < 0.05) associated with homatropine instillation. No significant changes in choroidal thickness, or ocular biometrics were found after 2.5% phenylephrine or placebo at any examination points (p > 0.05). In human subjects, significant increases in subfoveal and parafoveal choroidal thickness occurred after administration of 2% homatropine and this implies an involvement of the parasympathetic system in the control of choroidal thickness in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes algorithms that can identify patterns of brain structure and function associated with Alzheimer's disease, schizophrenia, normal aging, and abnormal brain development based on imaging data collected in large human populations. Extraordinary information can be discovered with these techniques: dynamic brain maps reveal how the brain grows in childhood, how it changes in disease, and how it responds to medication. Genetic brain maps can reveal genetic influences on brain structure, shedding light on the nature-nurture debate, and the mechanisms underlying inherited neurobehavioral disorders. Recently, we created time-lapse movies of brain structure for a variety of diseases. These identify complex, shifting patterns of brain structural deficits, revealing where, and at what rate, the path of brain deterioration in illness deviates from normal. Statistical criteria can then identify situations in which these changes are abnormally accelerated, or when medication or other interventions slow them. In this paper, we focus on describing our approaches to map structural changes in the cortex. These methods have already been used to reveal the profile of brain anomalies in studies of dementia, epilepsy, depression, childhood- and adult-onset schizophrenia, bipolar disorder, attention-deficit/hyperactivity disorder, fetal alcohol syndrome, Tourette syndrome, Williams syndrome, and in methamphetamine abusers. Specifically, we describe an image analysis pipeline known as cortical pattern matching that helps compare and pool cortical data over time and across subjects. Statistics are then defined to identify brain structural differences between groups, including localized alterations in cortical thickness, gray matter density (GMD), and asymmetries in cortical organization. Subtle features, not seen in individual brain scans, often emerge when population-based brain data are averaged in this way. Illustrative examples are presented to show the profound effects of development and various diseases on the human cortex. Dynamically spreading waves of gray matter loss are tracked in dementia and schizophrenia, and these sequences are related to normally occurring changes in healthy subjects of various ages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To characterize the changes occurring in choroidal thickness (ChT) across the posterior pole during accommodation using enhanced-depth imaging optical coherence tomography (OCT). Methods. Forty participants (mean age 21 ± 2 years) had measures of ChT and ocular biometry taken during accommodation to 0, 3, and 6 diopter (D) stimuli, with the Spectralis OCT and Lenstar biometer. A Badal optometer and cold mirror system was mounted on both instruments, allowing measurement collection while subjects viewed an external fixation target at varying accommodative demands. Results. The choroid exhibited significant thinning during accommodation to the 6 D stimulus in both subfoveal (mean change, −5 ± 7 μm) and parafoveal regions (P < 0.001). The magnitude of these changes varied by parafoveal meridian, with the largest changes seen in the temporal (−9 ± 12 μm) and inferotemporal (−8 ± 8 μm) meridians (P < 0.001). Axial length increased with accommodation (mean change, +5 ± 11 μm at 3 D, +14 ± 13 μm at 6 D), and these changes were weakly negatively associated with the choroidal changes (r2 = 0.114, P < 0.05). Conclusions. A small, but significant thinning of the choroid was observed at the 6 D accommodation demand, which was greatest in the temporal and inferotemporal parafoveal choroid, and increased with increasing eccentricity from the fovea. The regional variation in the parafoveal thinning corresponds to the distribution of the nonvascular smooth muscle within the uvea, which may implicate these cells as the potential mechanism by which the choroid thins during accommodation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The role of melt convection oil the performance of beat sinks with Phase Change Material (PCM) is presented in this paper. The beat sink consists of aluminum plate fins embedded in PCM and heat flux is supplied from the bottom. The design of such a heat sink requires optimization with respect to its geometrical parameters. The objective of the optimization is to maximize the heat sink operation time for the prescribed heat flux and the critical chip temperature. The parameters considered for optimization are fin number and fill thickness. The height and base plate thickness of heat sink are kept constant in the present analysis. An enthalpy based CFD model is developed, which is capable Of Simulating phase change and associated melt convection. The CFD model is Coupled with Genetic Algorithm (GA) for carrying out the optimization. Two cases are considered, one without melt convection (conduction regime) and the other with convection. It is found that the geometrical optimizations of heat sinks are different for the two cases, indicating the importance of inch convection in the design of heat sinks with PCMs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Analytical solution of a 2-dimensional problem of solidification of a superheated liquid in a semi-infinite mould has been studied in this paper. On the boundary, the prescribed temperature is such that the solidification starts simultaneously at all points of the boundary. Results are also given for the 2-dimensional ablation problem. The solution of the heat conduction equation has been obtained in terms of multiple Laplace integrals involving suitable unknown fictitious initial temperatures. These fictitious initial temperatures have interesting physical interpretations. By choosing suitable series expansions for fictitious initial temperatures and moving interface boundary, the unknown quantities can be determined. Solidification thickness has been calculated for short time and effect of parameters on the solidification thickness has been shown with the help of graphs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To examine longitudinal changes in choroidal thickness and axial length in a population of children with a range of refractive errors. METHODS One hundred and one children (41 myopes and 60 nonmyopes) aged 10 to 15 years participated in this prospective, observational longitudinal study. For each child, 6-month measures of choroidal thickness (using enhanced depth imaging optical coherence tomography) and axial ocular biometry were collected four times over an 18-month period. Linear mixed-models were used to examine the longitudinal changes in choroidal thickness and the relationship between changes in choroidal thickness and axial eye growth over the study period. RESULTS A significant group mean increase in subfoveal choroidal thickness was observed over 18 months (mean increase 13 6 22 lm, P < 0.001). Myopic children exhibited significantly thinner choroids compared with nonmyopic children (P < 0.001), although there was no significant time by refractive group interaction (P ¼ 0.46), indicating similar changes in choroidal thickness over time in myopes and nonmyopes. However, a significant association between the change in choroidal thickness and the change in axial length over time was found (P < 0.001, β = −0.14). Children showing faster axial eye growth exhibited significantly less choroidal thickening over time compared with children showing slower axial eye growth. CONCLUSIONS A significant increase in choroidal thickness occurs over an 18-month period in normal 10- to 15-year-old children. Children undergoing faster axial eye growth exhibited less thickening and, in some cases, a thinning of the choroid. These findings support a potential role for the choroid in the mechanisms regulating eye growth in childhood.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements of both the velocity and the temperature field have been made in the thermal layer that grows inside a turbulent boundary layer which is subjected to a small step change in surface heat flux. Upstream of the step, the wall heat flux is zero and the velocity boundary layer is nearly self-preserving. The thermal-layer measurements are discussed in the context of a self-preserving analysis for the temperature disturbance which grows underneath a thick external turbulent boundary layer. A logarithmic mean temperature profile is established downstream of the step but the budget for the mean-square temperature fluctuations shows that, in the inner region of the thermal layer, the production and dissipation of temperature fluctuations are not quite equal at the furthest downstream measurement station. The measurements for both the mean and the fluctuating temperature field indicate that the relaxation distance for the thermal layer is quite large, of the order of 1000θ0, where θ0 is the momentum thickness of the boundary layer at the step. Statistics of the thermal-layer interface and conditionally sampled measurements with respect to this interface are presented. Measurements of the temperature intermittency factor indicate that the interface is normally distributed with respect to its mean position. Near the step, the passive heat contaminant acts as an effective marker of the organized turbulence structure that has been observed in the wall region of a boundary layer. Accordingly, conditional averages of Reynolds stresses and heat fluxes measured in the heated part of the flow are considerably larger than the conventional averages when the temperature intermittency factor is small.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increase in optical band gap (photo bleaching) due to light illumination was studied at room temperature as well as at low (4.2 K) temperature for Sb/As2S3 multilayered film of 640 nm thickness by Fourier Transform Infrared Technique. The interdiffusion of Sb into As2S3 matrix results the formation of Sb-As2S3 ternary solid solutions which is explained by the change in optical band gap (E-g), absorption coefficient (alpha), Tauc parameter (B-1/2), Urbach edge (E-e). At the same time, photo darkening phenomena was observed in (As2S3)(0.93)Sb-0.07 film of same thickness both at low and room temperatures. From our X-ray Photoelectron Spectroscopy measurements,we are able to show that some of the As-As, S-S and Sb-Sb bonds are converted into As-S and S-Sb bonds in case of multilayers. We found that the energetically favoured heteropolar bond formation take place by a phonon-assisted mechanism using the lone pair pi electrons of S-2(0). But in case of (As2S3)(0.93)Sb-0.02 film, the homopolar bonds are playing a major role. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Exposure with above band gap light and thermal annealing at a temperature near to glass transition temperature, of thermally evaporated amorphous (As2S3)(0.87)Sb-0.13 thin films of 1 mu m thickness, were found to be accompanied by structural effects, which in turn, lead to changes in the optical properties. The optical properties of thin films induced by illumination and annealing were studied by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and Raman spectroscopy. Photo darkening or photo bleaching was observed in the film depending upon the conditions of the light exposure or annealing. These changes of the optical properties are assigned to the change of homopolar bond densities. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polycrystalline Ti thin films are shown to gradually transform from face-centered cubic (fcc) to hexagonal close-packed structure (hcp) with increasing film thickness. Diffraction stress analysis revealed that the fcc phase is formed in a highly compressive hcp matrix (>= 2 GPa), the magnitude of which decreases with increasing film thickness. A correlation between stress and crystallographic texture vis-a-vis the fcc-hcp phase transformation has been established. The total free energy change of the system upon phase transformation calculated using the experimental results shows that the fcc-hcp transformation is theoretically possible in the investigated film thickness regime (144-720 nm) and the hcp structure is stable for films thicker than 720 nm, whereas the fcc structure can be stabilized in Ti films much thinner than 144 nm. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the electrical switching behavior of three telluride based amorphous chalcogenide thin film samples, Al-Te, Ge-Se-Te and Ge-Te-Si. These amorphous thin films are made using bulk glassy ingots, prepared by conventional melt quenching technique, using flash evaporation technique; while Al-Te sample has been coated in coplanar electrode geometry, Ge-Se-Te and Ge-Te-Si samples have been deposited with sandwich electrodes. It is observed that all the three samples studied, exhibit memory switching behavior in thin film form, with Ge-Te-Si sample exhibiting a faster switching characteristic. The difference seen in the switching voltages of the three samples studied has been understood on the basis of difference in device geometry and thickness. Scanning electron microscopic image of switched region of a representative Ge15Te81Si4 sample shows a structural change and formation of crystallites in the electrode region, which is responsible for making a conducting channel between the two electrodes during switching.