207 resultados para tee


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The assessment of food intake is essential for the development of dietetic interventions. Accuracy is low when intake is assessed by questionnaires, the under-reporting of food intake being frequent. Most such studies, however, were performed in developed countries and there is little data about the older population of developing nations. This study aimed to verify the total energy expenditure (TEE) of independent older Brazilians living in an urban area, through the doubly labelled water (DLW) method and to compare it with the reported energy intake obtained through the application of a food frequency questionnaire (FFQ). Initially, 100 volunteers aged from 60 to 75 years had their body composition determined by dual-energy X-ray absorptiometry (DEXA). Five volunteers of each quartile of body fat percentage had their energy expenditure determined by DLW. The mean age of the subjects included in this phase of the study was 66.4 +/- 3.5 years, and ten of the subjects were men. The mean TEE was 2565 +/- 614 and 2154 +/- 339 kcal.day(-1) for men and women, respectively. The Physical Activity Level (PAL) was 1.58 +/- 0.31 and 1.52 +/- 0.22, respectively. Under-reporting of food intake was highly prevalent, with a mean percentage of reported intake in relation to measured TEE of -17.7%. Thus, under-reporting of food intake is highly prevalent among Brazilian independent older persons. The DLW method is an important tool in nutritional studies and its use is to be recommended in developing countries. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Positive end-expiratory pressure (PEEP) and sustained inspiratory insufflations (SI) during acute lung injury (ALI) are suggested to improve oxygenation and respiratory mechanics. We aimed to investigate the hemodynamic effects of PEEP with and without alveolar recruiting maneuver in a mild ALI model induced by inhalation of hydrochloric acid. Thirty-two pigs were randomly allocated into four groups (Control-PEEP, Control-SI, ALI-PEEP and ALI-SI). ALI was induced by intratracheal instillation of hydrochloric acid. PEEP values were progressively increased and decreased from 5, 10, 15 and 20 cmH(2)O in all groups. Three SIs maneuvers of 30 cmH(2)O for 20 s were applied to the assignable groups between each PEEP level. Transesophageal echocardiography (TEE), global hemodynamics, oxygenation indexes and gastric tonometry were measured 5 min after the maneuvers had been concluded and at each established value of PEEP (5, 10, 15 and 20 cmH(2)O). The cardiac index, ejection fraction and end-diastolic volume of right ventricle were significantly (P < 0.001) decreased with PEEP in both Control and ALI groups. Left ventricle echocardiography showed a significant decrease in end-diastolic volume at 20 cmH(2)O of PEEP (P < 0.001). SIs did not exert any significant hemodynamic effects either early (after 5 min) or late (after 3 h). In a mild ALI model induced by inhalation of hydrochloric acid, significant hemodynamic impairment characterized by cardiac function deterioration occurred during PEEP increment, but SI, probably due to low applied values (30 cmH(2)O), did not exert further negative hemodynamic effects. PEEP should be used cautiously in ALI caused by acid gastric content inhalation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The New Zealand's Royal Commission on Genetic Modification (RCGM)'s report was released in the year 2001. RCGM's findings supports the ongoing development of genetic engineering in New Zealand and recommends the recommencement of genetic modification field trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this investigation was to assess changes in total energy expenditure (TEE), body weight (BW) and body composition following a peripheral blood stem cell transplant and following participation in a 3-month duration, moderate-intensity, mixed-type exercise programme. The doubly labelled and singly labelled water methods were used to measure TEE and total body water (TBW). Body weight and TBW were then used to calculate percentage body fat (%BF), and fat and fat-free mass (FFM). TEE and body composition measures were assessed pretransplant (PI), immediately post-transplant (PII) and 3 months post-PII (PIII). Following PII, 12 patients were divided equally into a control group (CG) or exercise intervention group (EG). While there was no change in TEE between pre- and post-transplant, BW (P

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose : Myelomeningocele is a complex disease often complicated by obesity for reasons not well understood. The objectives of this study were to determine body composition and energy expenditure of children with MMC. Methods : Resting energy expenditure (REE), body composition and anthropometry were measured in 19 children with MMC (12 M, 7 F). Total energy expenditure (TEE) was estimated using a 3-day activity record. Energy intake (EI) was measured in seven children (5 M, 2 F) with MMC. Data were then compared with predicted values. Results : Mean REE ( n = 19) was 4680 ±1452 kJ/day (96.1 ±18.1% of predicted REE). The range was large (45.8-125.7% of predicted REE). TEE ( n = 7) was 4344 ±2376 kJ/day, hence only 73 34% of predicted TEE. EI ( n = 7) was 6560 ±1329 kJ/day, approximating a normal energy requirement. Overall, BCM was lower than expected values. Conclusions : REE in children with MMC is variable when compared to predicted values. TEE was found to be lower in children with MMC than predicted values and EI was similar to predicted values in this group of seven children. BCM is reduced in children with MMC when compared to expected values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: A knowledge of energy expenditure in infancy is required for the estimation of recommended daily amounts of food energy, for designing artificial infant feeds, and as a reference standard for studies of energy metabolism in disease states. Objectives: The objectives of this study were to construct centile reference charts for total energy expenditure (TEE) in infants across the first year of life. Methods: Repeated measures of TEE using the doubly labeled water technique were made in 162 infants at 1.5, 3, 6, 9 and 12 months. In total, 322 TEE measurements were obtained. The LMS method with maximum penalized likelihood was used to construct the centile reference charts. Centiles were constructed for TEE expressed as MJ/day and also expressed relative to body weight (BW) and fat-free mass (FFM). Results: TEE increased with age and was 1.40,1.86, 2.64, 3.07 and 3.65 MJ/day at 1.5, 3, 6, 9 and 12 months, respectively. The standard deviations were 0.43, 0.47, 0.52, 0.66 and 0.88, respectively. TEE in MJ/kg increased from 0.29 to 0.36 and in MJ/day/kg FFM from 0.36 to 0.48. Conclusions: We have presented centile reference charts for TEE expressed as MJ/day and expressed relative to BW and FFM in infants across the first year of life. There was a wide variation or biological scatter in TEE values seen at all ages. We suggest that these centile charts may be used to assess and possibly quantify abnormal energy metabolism in disease states in infants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increased integration of wind power into the electric grid, as nowadays occurs in Portugal, poses new challenges due to its intermittency and volatility. Hence, good forecasting tools play a key role in tackling these challenges. In this paper, an adaptive neuro-fuzzy inference approach is proposed for short-term wind power forecasting. Results from a real-world case study are presented. A thorough comparison is carried out, taking into account the results obtained with other approaches. Numerical results are presented and conclusions are duly drawn. (C) 2011 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the recent technical improvement in echocardiography imaging (second harmonics) the number of interatrial septum aneurysms (ASA) increased and are easily recognized. We assist to an overdiagnosing number of cases and diagnostic criteria emerged to face this problem. In the great majority of the cases ASA are small and inoffensive, but as ASA is considered a risk factor for cardioembolism when associated with persistence of foramen oval (PFO), an examination by transesophageal echocardiography (TEE) for exclusion of PFO makes the sense and is a common testing in patients with cryptogenic stroke. Besides these frequent ASA, other forms exist; the authors describe two cases of uncommon and huge ASA, one mimicking a right atrial tumor and the other a quistic, hipoechoic mass. The first case was associated with mitral stenosis and was submitted to surgery and the second was closed with an Amplatzer occluder device usually used in atrial septal defect (ASD).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the recent technical improvement in echocardiography imaging (second harmonics) the number of interatrial septum aneurysms (ASA) increased and are easily recognized. We assist to an overdiagnosing number of cases and diagnostic criteria emerged to face this problem. In the great majority of the cases ASA are small and inoffensive, but as ASA is considered a risk factor for cardioembolism when associated with persistence of foramen oval (PFO), an examination by transesophageal echocardiography (TEE) for exclusion of PFO makes the sense and is a common testing in patients with cryptogenic stroke. Besides these frequent ASA, other forms exist; the authors describe two cases of uncommon and huge ASA, one mimicking a right atrial tumor and the other a quistic, hipoechoic mass. The first case was associated with mitral stenosis and was submitted to surgery and the second was closed with an Amplatzer occluder device usually used in atrial septal defect (ASD).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 75-year old female patient, with previous inferior acute myocardial infarction (AMI) in December 2000, was admitted in April 2001 with angina and heart failure. Transthoracic echocardiography (TTE) was suggestive of a postero-inferior pseudoaneurysm (PA) of the left ventricle (LV), with 61x49 mm. of size and mitral regurgitation. Cardiac catheterization was suspected of a PA of the LV and revealed a three vessels coronary artery disease. On 20th April she was submitted to cardiac surgery with resection of a large LV aneurysm (AN) and triple coronary artery bypass surgery. Afterwards, she was on NYHA class III and subsequent TTE and transesophagic echocardiography (TEE) were suggestive of a 90x60 mm LV posterior PA (confirmed by nuclear magnetic resonance) and severe mitral regurgitation, with good LV systolic function. She underwent a new cardiac surgery on 31st May 2002, with resuturing of the LV postero-inferior wall patch and removal of the PA. The patient is in good condition and on NYHA functional class I-II.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Peripheral embolism is frequently related to a cardiac source of embolism. Transesophageal echocardiography (TEE) is a useful tool for identifying such sources. OBJECTIVES: Our laboratory has gained wide experience in TEE, with a large number of exams performed to search for a cardiac source of embolism. We therefore thought it would be useful to present our experience in the last 12 years following the introduction of the technique. METHODS: This was a retrospective study of 1110 consecutive patients undergoing TEE to search for a cardiac source of embolism, after an embolic event and a transthoracic echocardiogram. RESULTS: The patients' mean age was 53 +/- 14 years, 52% male. There was peripheral embolism in 5% of cases and cerebral embolism in the remainder. The exam identified a potential embolic source in 35.6% of cases, the most frequent diagnoses being intracardiac shunt at the atrial level (9.5%), atrial septal aneurysm (ASA) (6.6%), intracardiac thrombi (6.4%) and atherosclerotic plaques in the thoracic aorta (9.6%). The presence of ASA was frequently associated with patent foramen ovale (27%), which was more frequent in younger patients. Overall, we identified a cardiac source of embolism more often in elderly patients, with a predominance of atherosclerotic plaques in the aorta. ETE was more frequently diagnostic in patients with peripheral embolism, but there were no differences in terms of etiology. CONCLUSIONS: TEE is very useful to search for cardiac sources of embolism, especially in younger patients, in whom causes potentially treatable surgically or percutaneously can be identified. In elderly patients, therapeutic strategy will probably not be changed by the findings (mostly thrombi and atherosclerotic plaques). The presence of ASA and embolic events makes it essential to perform a thorough search by TEE for intracardiac shunts, which are frequently associated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Evaluation of the role of transesophageal echocardiography in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: Patients were selected for percutaneous closure of ASD by transesophageal echocardiography (TEE), which was also used to monitor the procedure, helping to select the appropriate size of the Amplatzer device, to verify its position, and to access the immediate results of the procedure. During the follow-up, TEE was used to evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiac chamber diameters. RESULTS: Twenty-two (40%) of a total of 55 studied patients were selected. Thirteen underwent Amplatzer device implantation, eight are still waiting for it, and one preferred the conventional surgical treatment. All procedures were successful, which was mainly due to proper patient selection. Six (23%) patients acutely developed RS, which spontaneously disapeared at the three-month follow-up examination in three patients. There was a significant reduction in the right ventricle diastolic diameter, from 27mm (average) to 24mm and 20mm, one and three months after the procedure, respectively (p<0.0076). CONCLUSION: With the aid of TEE, percutaneous closure of ASD can be successfully, safely, and effectively performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The accurate estimation of total daily energy expenditure (TEE) in chronic kidney patients is essential to allow the provision of nutritional requirements; however, it remains a challenge to collect actual physical activity and resting energy expenditure in maintenance dialysis patients. The direct measurement of TEE by direct calorimetry or doubly labeled water cannot be used easily so that, in clinical practice, TEE is usually estimated from resting energy expenditure and physical activity. Prediction equations may also be used to estimate resting energy expenditure; however, their use has been poorly documented in dialysis patients. Recently, a new system called SenseWear Armband (BodyMedia, Pittsburgh, PA) was developed to assess TEE, but so far no data have been published in chronic kidney disease patients. The aim of this review is to describe new measurements of energy expenditure and physical activity in chronic kidney disease patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: To measure resting metabolic rate (RMR), activity energy expenditure (AEE), total energy expenditure (TEE) and physical activity pattern, that is, duration and intensity (in metabolic equivalents, METs) of activities performed in late pregnancy compared with postpartum in healthy, well-nourished women living in Switzerland. SUBJECTS/METHODS: Weight, height, RMR, AEE, TEE and physical activity patterns were measured longitudinally in 27 healthy women aged 23-40 years at 38.2+/-1.5 weeks of gestation and 40.0+/-7.2 weeks postpartum. RESULTS: The RMR during late pregnancy was 7480 kJ per day, that is, 1320+/-760 kJ per day (21.4%) higher than the postpartum RMR (P<0.001). Absolute changes in RMR were positively correlated with the corresponding changes in body weight (r=0.61, P<0.001). RMR per kg body weight was similar in late pregnancy vs postpartum (P=0.28). AEE per kg during pregnancy and postpartum was 40+/-13 and 50+/-20 kJ/kg, respectively (P=0.001). There were significant differences in daily time spent at METs<1.5 (1067 vs 998 min, P=0.045), at 2.5< or =METs <3.0 (58 vs 82 min, P=0.002) and METs> or =6 (1 vs 6 min, P=0.014) during pregnancy and postpartum, respectively. CONCLUSIONS: Energy expenditure in healthy women living in Switzerland increases in pregnancy compared with the postpartum state. Additional energy expenditure is primarily attributed to an increase in RMR, which is partly compensated by a decrease in AEE. The decrease in physical activity-related energy costs is achieved by selecting less demanding activities and should be taken into account when defining extra energy requirements for late pregnancy in Switzerland.