980 resultados para subcutaneous tissue


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: This study aimed evaluating histologically and histomorphometrically the response of the conjunctive tissue face to the implant of chlorhexidine chips in the subcutaneous tissues of rats. Study Design: In this research 35 male rats Wistar were used to analyze the biocompatibility and the degradation process of chlorhexidine chip. In each animal, it was made 2 incisions for subcutaneous implantation of chlorhexidine chip (test group) and a polytetrafluorethylene membrane (control group). The morphological changes in subcutaneous implantations were assessed after 1, 3, 5, 7, 10, 14, 21 days. The data were submitted to Friedman nonparametric test to analyze the comparisons among observation periods and to allow the comparison among groups. Results: Differences were found in the analysis of the inflammatory response when comparing the tested materials (p values <= 0.05). In test group was observed hemorrhage, edema and intense inflammatory infiltrate predominantly neutrophilic around material. From 3-day and subsequent periods was verified granulation tissue externally at this infiltrate. From 10-day on was observed crescent area of degradation of chlorhexidine chip, associated with neutrophilic and macrophagic infiltrate, that maintained until 21-day. In the control group, moderate inflammatory infiltrate was observed initially, predominantly polymorphonuclear, edema and granulation tissue 3-day period. The inflammatory infiltrate was gradually replaced for granulation tissue, culminating in a fibrous capsule. Giant multinucleate cells situated at contact interface with the coating was examined since 3-day and persisted until 21-day. Conclusion: The chlorhexidine chip induces an intense acute inflammatory response at subcutaneous tissue of rats. Therefore, at conditions of this study was not biocompatible.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: The objective of the present study was to evaluate the tissue inflammatory response induced by calcium hydroxide pastes, with or without paramonochlorophenol and camphor. Methodology: Isogenic BALB/c mice were inoculated into the subcutaneous tissue with either 0.1 mL of a suspension of Calen, Calen with camphorated paramonochlorophenol, Calen with paramonochlorophenol, Calasept paste or phosphate-buffered saline (control). After 6, 12 and 24 h and 2, 3, 5, 7 and 15 days, three animals in each group were sacrificed and the excised lesions processed for histopathological evaluation of the inflammatory response. Events monitored and graded included the assessment of vascular congestion, oedema, haemorrhage, inflammatory infiltrate, necrosis and tissue repair. Results: The pastes induced an inflammatory response at every observation period, although the intensity, duration and extension of inflammation varied. Calen paste always produced an initial short-term inflammatory response whilst the other pastes produced extended reactions. All pastes allowed repair to take place by the end of the experimental period, although the speed of this process varied between the materials. Calen presented the best biocompatibility; the phenolic compound caused greater tissue response, which was even more severe in the absence of camphor. Calasept paste was damaging and the repair process slower. Conclusions: All calcium hydroxide formulations caused an inflammatory response. The severity and longevity of the responses varied between pastes as a result of the various antiseptic agents. Although irritating, repair was apparent with all formulations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this paper was to study the reaction of rat subcutaneous connective tissue to the implantation of dentin tubes filled with white mineral trioxide aggregate (MTA), a material that will be marketed. The tubes were implanted into rat subcutaneous tissue and the animals were sacrificed after 7 and 30 days. The undecalcified pieces were prepared for histological analysis with polarized light and von Kossa technique for mineralized tissues. Granulations birefringent to polarized light and an irregular structure like a bridge were observed next to the material; both were von Kossa positive. Also, in the dentin wall tubules a layer of birefringent granulations was observed. The results were similar to those reported for gray MTA, indicating that the mechanisms of action of the white and gray MTA are similar.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the host response of a human and a porcine derived acellular dermal tissue (ADT) implanted in the subcutaneous tissue of a rat model. Two subcutaneous pockets were surgically created along the dorsal midline of 25 rats (5 rats/group). The human ADT was placed superiorly and the porcine ADT, inferiorly. The animals were sacrificed at 07, 15, 30, 60 and 180 postoperative days (PO) and the ADTs and surrounding soft tissues were assessed for ultrastructural evaluation by transmission electron microscopy. The ultrastructural findings were similar in both materials. Normal collagen and elastic fibers bundles were observed during all experimental moments, as well as macrophages presenting cytoplasmic enlargements digesting cellular portions after 15 PO. From 30 until 180 PO, vacuolar structures filled with an amorphous, electron-transparent substance, were present inside and outside the fibroblasts. Both human and porcine ADT showed similar pattern of ultrastructural response when implanted in the subcutaneous tissue of rats. The porcine ADT appears as a good alternative to be used as a biomaterial.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The study compared the host response to a human and a porcine acellular dermal tissue implanted in the subcutaneous space of a rat model. The human and porcine acellular grafts were surgically implanted in the subcutaneous tissue of rats (5 rats/group) and the materials were evaluated at 7, 15, 30, 60 and 180 postoperative days (PO). The histological immune response was quantified using a digital image analysis system, which evaluated the number of vessels present in the implants and in the surrounding soft tissue, the area of inflammatory cell infiltration in the grafts, the width of the capsular formation present around the tissues and the area of implants absorbed. The data were submitted to statistical analysis. Light microscopy showed mononuclear cellular infiltration, the presence of a capsular formation surrounding the grafts and the presence of vacuolar structures (optically empty spaces) inside the implants. The image analysis comparing both materials showed significant inflammatory cells in the human graft at 15 and 30 PO, thicker capsular formation in the porcine tissue at 60 PO, increased number of vessels inside the implants and in the surrounding tissues in the porcine graft and a similar absorption pattern in both materials at 180 PO. The histological findings showed that both tissues were well-tolerated when implanted in the subcutaneous tissue of rats, allowing us to consider the porcine acellular dermal graft as a provisional alternative material for reconstructive plastic surgery. Copyright © 2005 Taylor & Francis LLC.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Necrotizing soft tissue infection (NSTI) is characterized by progressive infectious gangrene of the skin and subcutaneous tissue. Its treatment involves intensive care, broad-spectrum antibiotic therapy, and full debridement. Methods: We present two cases of NSTI of the breast, adding these cases to the 14 described in the literature, reviewing the characteristics and evolution of all cases. Case Report: On the fourth day after mastectomy, a 59-year-old woman with ulcerated breast cancer developed Type I NSTI caused by Pseudomonas aeruginosa, which had a favorable evolution after debridement and broad-spectrum antibiotics. The second patient was a 57-year-old woman submitted to a mastectomy and axillary dissection, who had recurrent seromas. On the 32nd post-operative day, after a seroma puncture, she developed Type II NSTI caused by β-hemolytic streptococci. She developed sepsis and died on the tenth day after debridement, intensive care, and broad-spectrum antibiotics. The cases are the first description of breast NSTI after mammary seroma aspiration and the first report of this condition caused by P. aeruginosa. Conclusion: Necrotizing soft tissue infection is rare in breast tissue. It frequently is of Type II, occurring mainly after procedures in patients with breast cancer. The surgeon's participation in controlling the focus of the infection is of fundamental importance, and just as important are broad-spectrum antibiotic therapy and support measures, such as maintenance of volume, correction of electrolytic disorders, and treatment of sepsis and septic shock. Once the infection has been brought under control, skin grafting or soft tissue flaps can be considered. The mortality rate in breast NSTI is 18.7%, all deaths being in patients with the fulminant Type II form. Surgical oncologists need to be alert to the possibility of this rare condition. © 2012, Mary Ann Liebert, Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The results of the histopathological analyses after the implantation of highly crystalline PVA microspheres in subcutaneous tissues of Wistar rats are here in reported. Three different groups of PVA microparticles were systematically studied: highly crystalline, amorphous, and commercial ones. In addition to these experiments, complementary analyses of architectural complexity were performed using fractal dimension (FD), and Shannon's entropy (SE) concepts. The highly crystalline microspheres induced inflammatory reactions similar to the ones observed for the commercial ones, while the inflammatory reactions caused by the amorphous ones were less intense. Statistical analyses of the subcutaneous tissues of Wistar rats implanted with the highly crystalline microspheres resulted in FD and SE values significantly higher than the statistical parameters observed for the amorphous ones. The FD and SE parameters obtained for the subcutaneous tissues of Wistar rats implanted with crystalline and commercial microparticles were statistically similar. Briefly, the results indicated that the new highly crystalline microspheres had biocompatible behavior comparable to the commercial ones. In addition, statistical tools such as FD and SE analyses when combined with histopathological analyses can be useful tools to investigate the architectural complexity tissues caused by complex inflammatory reactions. © 2012 WILEY PERIODICALS, INC.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives: This study evaluated subcutaneous tissue response to Aroeira (Myracrodruon urundeuva) extract employing edemogenic and histological analyses. Material and methods: Test groups consisted of aqueous and ethanolic Aroeira extracts and saline (control). For groups consisted of aqueous and ethanolic Aroeira extracts and saline Blue. After 30 min, the extracts and saline were injected on the dorsum of the rats, which were then sacrificed after 3 and 6 h. Readings were performed in a spectrophotometer. For subcutaneous implantation, 30 rats received a polyethylene tube containing the extracts on their dorsum and then they were killed after 7 and 28 days. The samples were processed for histological analysis and evaluated with a light microscope. The inflammatory infiltrate was quantified. Results: There were no statistically significant differences between aqueous extract and saline groups in relation to edema quantification in the different periods (p > 0.05). Ethanolic solution resulted in more edema independently of the experimental period (p < 0.05). Histological analysis showed similar results on the 7-day period for the 3 groups. There was a notable reduction on inflammatory cell number for saline and aqueous extract groups at 28 days. Conclusion: The aqueous extract showed biocompatible properties similar to those of saline.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: The sealers can be in direct contact with the periapical tissues. Thus, these materials must have appropriate physical and biological properties, providing conditions for repair to occur. Objective: The aim of this study was to evaluate the response of rat subcutaneous tissue to endodontics sealers. Material and methods: Three materials comprised the groups: group I – Zinc Oxide, Eugenol and Iodoform paste, group II – Portland cement with propylene glycol, and group III – MTA Fillapex® (Angelus). These materials were placed in polyethylene tubes and implanted into dorsal connective tissue of Wistar rats for seven and 15 days. The specimens were stained with hematoxylin and eosin and evaluated regarding to inflammatory reaction parameters through a light microscope. The data were compared using Kruskal-Wallis test with significance level of 5%. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated observers for all experimental periods. Results: The histological evaluation showed that all the materials caused a moderated inflammatory reaction at seven days which decreased with time. A greater inflammatory reaction was observed at seven days in group I. The other specimens had significantly less inflammatory cells when compared to this group. Tubes with MTA Fillapex® presented some giant cells, macrophages and lymphocytes after seven days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The group II showed similar results to those observed in MTA Fillapex® already at seven days. At 15 days the inflammatory reaction presented was almost absent at the tissue, with many collagen fibers indicating normal tissue healing. Statistical analysis showed a significant statistical difference amongst the group I (seven days) and II (15 days) (p < 0.05). In the other groups no (Continue)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: The sealers can be in direct contact with the periapical tissues. Thus, these materials must have appropriate physical and biological properties, providing conditions for repair to occur. Objective: The aim of this study was to evaluate the response of rat subcutaneous tissue to endodontics sealers. Material and methods: Three materials comprised the groups: group I – Zinc Oxide, Eugenol and Iodoform paste, group II – Portland cement with propylene glycol, and group III – MTA Fillapex® (Angelus). These materials were placed in polyethylene tubes and implanted into dorsal connective tissue of Wistar rats for seven and 15 days. The specimens were stained with hematoxylin and eosin and evaluated regarding to inflammatory reaction parameters through a light microscope. The data were compared using Kruskal-Wallis test with significance level of 5%. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated observers for all experimental periods. Results: The histological evaluation showed that all the materials caused a moderated inflammatory reaction at seven days which decreased with time. A greater inflammatory reaction was observed at seven days in group I. The other specimens had significantly less inflammatory cells when compared to this group. Tubes with MTA Fillapex® presented some giant cells, macrophages and lymphocytes after seven days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The group II showed similar results to those observed in MTA Fillapex® already at seven days. At 15 days the inflammatory reaction presented was almost absent at the tissue, with many collagen fibers indicating normal tissue healing. Statistical analysis showed a significant statistical difference amongst the group I (seven days) and II (15 days) (p < 0.05). In the other groups no significant statistical differences were observed. Conclusion: MTA Fillapex® and Portland cement with propylene glycol were more biocompatible than the other tested cements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Oxidative killing is the primary defense against surgical pathogens; risk of infection is inversely related to tissue oxygenation. Subcutaneous tissue oxygenation in obese patients is significantly less than in lean patients during general anesthesia. However, it remains unknown whether reduced intraoperative tissue oxygenation in obese patients results from obesity per se or from a combination of anesthesia and surgery. In a pilot study, we tested the hypothesis that tissue oxygenation is reduced in spontaneously breathing, unanesthetized obese volunteers. METHODS: Seven lean volunteers with a body mass index (BMI) of 22 +/- 2 kg/m(2) were compared to seven volunteers with a BMI of 46 +/- 4 kg/m(2). Volunteers were subjected to the following oxygen challenges: (1) room air; (2) 2 l/min oxygen via nasal prongs, (3) 6 l/min oxygen through a rebreathing face mask; (4) oxygen as needed to achieve an arterial oxygen pressure (arterial pO(2)) of 200 mmHg; and (5) oxygen as needed to achieve an arterial pO(2) of 300 mmHg. The oxygen challenges were randomized. Arterial pO(2) was measured with a continuous intraarterial blood gas analyzer (Paratrend 7); deltoid subcutaneous tissue oxygenation was measured with a polarographic microoxygen sensor (Licox). RESULTS: Subcutaneous tissue oxygenation was similar in lean and obese volunteers: (1) room air, 52 +/- 10 vs 58 +/- 8 mmHg; (2) 2 l/min, 77 +/- 25 vs 79 +/- 24 mmHg; (3) 6 l/min, 125 +/- 43 vs 121 +/- 25 mmHg; (4) arterial pO(2) = 200 mmHg, 115 +/- 42 vs 144 +/- 23 mmHg; (5) arterial pO(2) = 300 mmHg, 145 +/- 41 vs 154 +/- 32 mmHg. CONCLUSION: In this pilot study, we could not identify significant differences in deltoid subcutaneous tissue oxygen pressure between lean and morbidly obese volunteers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Insufficient blood flow and oxygenation in the intestinal tract is associated with increased incidence of postoperative complications after bowel surgery. High fluid volume administration may prevent occult regional hypoperfusion and intestinal tissue hypoxia. We tested the hypothesis that high intraoperative fluid volume administration increases intestinal wall tissue oxygen pressure during laparotomy. METHODS: In all, 27 pigs were anaesthetized, ventilated and randomly assigned to one of the three treatment groups (n = 9 in each) receiving low (3 mL kg-1 h-1), medium (7 mL kg-1 h-1) or high (20 mL kg-1 h-1) fluid volume treatment with lactated Ringer's solution. All animals received 30% and 100% inspired oxygen in random order. Cardiac index was measured with thermodilution and tissue oxygen pressure with a micro-oximetry system in the jejunum and colon wall and subcutaneous tissue. RESULTS: Groups receiving low and medium fluid volume treatment had similar systemic haemodynamics. The high fluid volume group had significantly higher mean arterial pressure, cardiac index and subcutaneous tissue oxygenation. Tissue oxygen pressures in the jejunum and colon were comparable in all three groups. CONCLUSIONS: The three different fluid volume regimens tested did not affect tissue oxygen pressure in the jejunum and colon, suggesting efficient autoregulation of intestinal blood flow in healthy subjects undergoing uncomplicated abdominal surgery.