912 resultados para stripping extraction of positive ions.
Resumo:
The extraction equilibria of Sc(III), Zr(IV), Ti(IV), Th(IV), Fe(III) and Lu(III) from sulphuric or hydrochloric acid media by Cyanex 923 (mixture of straight chain alkylated phosphine oxides) and Cyanex 925 (mixture of branched chain alkylated phosphine oxides) were studied at various aqueous acidities. The extractant Cyanex 923 demonstrated better scandium loading and selectivity for TI(IV). Fe(III) and Lu(III) than Cyanex 925. The effects of extractant concentration on the extractions of sulphuric acid and Sc(III) by Cyanex 923 were examined. The stoichiometries of the extraction reactions were postulated based on slope analysis. The experimental results indicate that Cyanex 923 can be employed to recover scandium directly from the hydrolytic mother solution arising from TiO2 production via the sulphate process. The parameters studied were scandium loading capacity, phase ratio, concentrations of Ti(IV) scrubbing and Sc(III) stripping agents. A new solvent extraction technology of scandium recovery was developed. The purity of the final Sc(III) product is above 95% with a yield > 94%. (C) 1998 Elsevier Science B.V.
Resumo:
The solvent extraction of Sc(III), Zr(IV), Th(IV), Fe(III) and Lu(III) with Cyanex 302 (bis(2,4,4-trimethylpentyl)monothiophosphinic acid) and Cyanex 301 ( bis(2,4,4-trimethylpentyl) dithiophosphinic acid) in n-hexane from acidic aqueous solutions has been investigated systematically. The effect of equilibrium aqueous acidity on the extraction with these reagents was studied. The separation of Th(IV), Fe(III) and Lu(III) from Sc(III), or the separation of other metals from Lu(III) with Cyanex 302, can be achieved by controlling the aqueous acidity. However, Cyanex 301 exhibited a poor selectivity for the above metals, except for Lu(III). The extraction of these metals with Cyanex 272, Cyanex 302 and Cyanex 301 has been compared. The stripping percentages of Sc(III) for Cyanex 302 and Cyanex 301 in a single stage are near 78% and 75% with 3.5 mol/L and 5.8 mol/L sulphuric acid solutions, respectively. The effects of extractant concentration and temperature on the extraction of Sc(III) were investigated. The stoichiometry of the extraction of Sc(III) with Cyanex 302 was determined. The role of different components of Cyanex 302 in the extraction of Sc(III) was discussed.
Resumo:
The seed oil from Nitraria tangutorum samples was obtained by supercritical carbon dioxide extraction methods. The extraction parameters for this methodology, including pressure, temperature, particle size and extraction time, were optimized. The free fatty acids in the seed oil were separated with a pre-column derivation method and 1,2-benzo-3,4-dihydrocarbazole-9-ethyl-p-toluenesulfonate (BDETS) as a labeling regent, followed by high-performance liquid chromatography (HPLC) with fluorescence detection. The target compounds were identified by mass spectrometry with atmospheric pressure chemical ionization (APCI in positive-ion mode). HPLC analysis shows that the main compositions of the seed oil samples were free fatty acids (FFAs) in high to low concentrations as follows: linoleic acid, oleic acid, hexadecanoic acid and octadecanoic acid. The assay detection limits (at signal-to-noise of 3:1) were 3.378-6.572 nmol/L. Excellent linear responses were observed, with correlation coefficients greater than 0.999. The facile BDETS derivatization coupled with mass spectrometry detection allowed the development of a highly sensitive method for analyzing free fatty acids in seed oil by supercritical CO2 extraction. The established method is highly efficient for seed oil extraction and extremely sensitive for fatty acid profile determination. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Deep inner-shell photodetachment of negative ions is shown to differ qualitatively and quantitatively from the corresponding process in neutral atoms and positive ions. As an example, calculations of the photodetachment of Li- out of the 1s shell, using an augmented R-matrix methodology, are presented and show numerous structures over a broad energy region including a new phenomenon: Auger decay of a shape resonance. Li- was selected because it is the simplest multishell negative ion and is amenable to experimental scrutiny.
Resumo:
The viability of using beams of molecular ions as a target for strong field fragmentation studies using intense ultra-short laser pulses is demonstrated. In this way the production mechanism for multiply charged ions in strong fields may be elucidated.
Resumo:
The nonlinear propagation of amplitude-modulated electrostatic wavepackets in an electron-positron-ion (e-p-i) plasma is considered, by employing a two-fluid plasma model. Considering propagation parallel to the external magnetic field, two distinct electrostatic modes are obtained, namely a quasi-thermal acoustic-like lower mode and a Langmuir-like optic-type upper one. These results equally apply in warm pair ion ( e. g. fullerene) plasmas contaminated by a small fraction of stationary ions ( or dust), in agreement with experimental observations and theoretical predictions in pair plasmas. Considering small yet weakly nonlinear deviations from equilibrium, and adopting a multiple-scales perturbation technique, the basic set of model equations is reduced to a nonlinear Schrodinger (NLS) equation for the slowly varying electric field perturbation amplitude. The analysis reveals that the lower ( acoustic) mode is mostly stable for large wavelengths, and may propagate in the form of a dark-type envelope soliton ( a void) modulating a carrier wavepacket, while the upper linear mode is intrinsically unstable, and thus favours the formation of bright-type envelope soliton ( pulse) modulated wavepackets. The stability ( instability) range for the acoustic ( Langmuir-like optic) mode shifts to larger wavenumbers as the positive-to-negative ion temperature ( density) ratio increases. These results may be of relevance in astrophysical contexts, where e-p-i plasmas are encountered, and may also serve as prediction of the behaviour of doped ( or dust-contaminated) fullerene plasmas, in the laboratory.
Resumo:
Heterocyclic aromatic amines (HCA) are carcinogenic mutagens formed during cooking of proteinaceous foods, particularly meat. To assist in the ongoing search for biomarkers of HCA exposure in blood, a method is described for the extraction from human plasma of the most abundant HCAs: 2-Amino-1-methyl-6-phenylimidazo(4,5-b)pyridine (PhIP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) and 2-amino-3,4,8-trimethylimidazo[4,5-f]quinoxaline (4,8-DiMeIQx) (and its isomer 7,8-DiMeIQx), using Hollow Fibre Membrane Liquid-Phase Microextraction. This technique employs 2.5 cm lengths of porous polypropylene fibres impregnated with organic solvent to facilitate simultaneous extraction from an alkaline aqueous sample into a low volume acidic acceptor phase. This low cost protocol is extensively optimised for fibre length, extraction time, sample pH and volume. Detection is by UPLC-MS/MS using positive mode electrospray ionisation with a 3.4 min runtime, with optimum peak shape, sensitivity and baseline separation being achieved at pH 9.5. To our knowledge this is the first description of HCA chromatography under alkaline conditions. Application of fixed ion ratio tolerances for confirmation of analyte identity is discussed. Assay precision is between 4.5 and 8.8% while lower limits of detection between 2 and 5 pg/mL are below the concentrations postulated for acid-labile HCA-protein adducts in blood.
Resumo:
Dissertação de mest., Engenharia Biológica, Faculdade de Ciências e Tecnologia, Univ. do Algarve, 2011
Resumo:
Tese de doutoramento, Informática (Engenharia Informática), Universidade de Lisboa, Faculdade de Ciências, 2014
Resumo:
The tetradentate ligand (C-5-BTBP) was able to extract americium(III) selectively from nitric acid. In octanol/kerosene the distribution ratios suggest that stripping will be possible. C-5-BTBP has unusual properties and potentially offers a means of separating metals, which otherwise are difficult to separate. For example C-5-BTBP has the potential to separate paliadium(II) from a mixture containing rhodium(III) and ruthenium(H) nitrosyl. In addition, C-5-BTBP has the potential to remove traces of cadmium from effluent or from solutions of other metals contaminated with cadmium. C-5-BTBP has potential as a reagent for the separation of americium(III) from solutions contaminated with iron(III) and nickel(II), hence offering a means of concentrating americium(III) for analytical purposes from nitric acid solutions containing high concentrations of iron(III) or nickel(II).
Resumo:
The separation by solvent extraction of Am-241(III) from Eu-152(III), in 1 M NaNO3 weakly acidic (pH 4) aqueous solutions, into dilute (ca. 10(-2) M) solutions of triazinylbipyridine derivatives (diethylhemi-BTP or di(benzyloxyphenyl) hemi-BTP) and chlorinated cobalt dicarbollide (COSAN) in 1-octanol or nitrobenzene has been studied. The N-tridentate heterocyclic ligands, which are selective for Am(III) over Eu(III), secured efficient separation of the two metal ions, while COSAN, strongly hydrophobic and fully dissociated in polar diluents, enhanced the extraction of the metal ions by ion-pair formation. Molecular interactions between the two co-extractants, observed at higher concentrations, led to the precipitation of their 1: 1 molecular adduct. In spite of that, efficient separations of Am and Eu ions were attained, with high separation factors, SFAm/Eu of 40 and even 60, provided the concentration of hemi-BTP was significantly greater than that of COSAN. Excess COSAN concentrations caused an antagonistic effect, decreasing both the distribution ratio of the metal ions and their separation factor.
Resumo:
Several alkylated cyclohexanones were investigated as potential diluents for the selective extraction of Am(III) and Eu(III) from nitric acid solutions by the CyMe4-BTBP ligand. No significant extraction of either of the metal ions was observed for these diluents themselves. In the extractions from 1 M HNO3, 3-methylcyclohexanone and 4-methylcyclohexanone gave comparable results to cyclohexanone whereas in the extractions from 4 M HNO3, 2-methylcyclohexanone, 3-methylcyclohexanone and 4-methylcyclohexanone all gave superior results. For the monomethylated diluents, DAm and SFAm/Eu decreased in the order of alkyl substitution 2 > 4 ~ 3. However, alkyl substitution of cyclohexanone significantly slows down the extraction kinetics compared to cyclohexanone, and the position of alkyl substitution was found to play an important role in the solvents properties. 3-Methylcyclohexanone was identified as the most promising of the diluents.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Solid paraffin-based carbon paste electrodes modified with 2-aminothiazole organofunctionalized silica have been applied to the anodic stripping determination of copper ions in ethanol fuel samples without any sample treatment. The proposed method comprised four steps: (1) copper ions preconcentration at open circuit potential directly in the ethanol fuel sample; (2) exchange of the solution and immediate cathodic reduction of the absorbate at controlled potential; (3) differential pulse anodic stripping voltammetry; (4) electrochemical surface regeneration by applying a positive potential in acid media. Factors affecting the preconcentration, reduction and stripping steps were investigated and the optimum conditions were employed to develop the analytical procedure. Using a preconcentration time of 20 min and reduction time of 120 s at -0.3 V versus Ag/AgCl(sat) a linear range from 7.5 x 10(-8) to 2.5 x 10(-6) mol L(-1) with detection limit of 3.1 x 10(-8) mol L(-1) was obtained. Interference studies have shown a decrease in the interference effect according to the sequence: Ni > Zn > Cd > Pb > Fe. However, the interference effects of these ions have not forbidden the application of the proposed method. Recovery values between 98.8 and 102.3% were obtained for synthetic samples spiked with known amounts of Cu(2+) and interfering metallic ions. The developed electrode was successfully applied to the determination of Cu(2+) in commercial ethanol fuel samples. The results were compared to those obtained by flame atomic absorption spectroscopy by using the F-test and t-test. Neither F-value nor t-value have exceeded the critical values at 95% confidence level, confirming that there are no significant differences between the results obtained by both methods. (c) 2006 Elsevier B.V. All rights reserved.