993 resultados para strength testing


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A companion paper described the partial-interaction localised properties that require the development of pseudo properties. If the quantification through experimental testing of these pseudo properties could be removed by the use of mechanics-based models, which is the subject of this paper, then this would: (a) substantially reduce the cost of developing new reinforced concrete products by reducing the amount of testing; (b) increase the accuracy of designing existing and novel reinforced concrete members and structures, bearing in mind that experimentally derived pseudo properties are only applicable within the range of the testing from which they were derived; and (c) reduce the cost and increase the accuracy of developing reinforced concrete design rules. This paper deals with the development of pseudo properties and behaviours directly through mechanics, as opposed to experimental testing, and their incorporation into member global simulations. It also addresses the need for a fundamental shift to displacement-based analyses as opposed to strain-based analyses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A recent model of the Single Fiber Analyzer 3001 (SIFAN3001) was firstly employed to obtain the single wool fiber diameter profiles (SfFDPs) at multiple orientations. The results showed that using SIFAN3001 to measure fiber diameter at four orientations for 50 single fibers randomly sub-sampled from each mid-side sample can produce average fiber diameter profiles (AS fFDPs) of fibers within staples. Within the testing regime used, the precision estimates for the total samples were ±1.3 µm for the mean fiber diameter of staples and 1.4 µm for the average fiber diameter of the AS fFDPs at each scanned step in the diameter profile. The mean diameter ratio (ellipticity) obtained from the four orientations was 1.08±0.01, confirming that the Merino wool fibers under review were elliptical rather than circular. The elliptical morphology of wool fibers and the precision of the fiber diameter measurement at each point along a fiber will be considered in the development of a mechanical model of Staple Strength testing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A recent model of Single Fibre Analyser 3001 (SIFAN3001) was firstly employed to obtain the single wool fibre diameter profiles (SfFDP’s) at multiple orientations. The results showed that using SIFAN3001 to measure fibre diameter at four orientations for 50 single fibres randomly sub-sampled from each mid-side sample can produce average fibre diameter profiles (ASfFDP’s) of fibres within staples. Within the testing regime used, the precision estimates for the total samples were ±1.3µm for mean fibre diameter of staples and ±1.4µm for average fibre diameter of the ASfFDP’s at each scanned step in the diameter profile. The mean diameter ratio (ellipticity) obtained from the four orientations was 1.08±0.01, confirming that the Merino wool fibres under review were elliptical rather than circular. The elliptical morphology of wool fibres and the precision of fibre diameter measurement at each point along a fibre will be considered in the development of a mechanical model of Staple Strength testing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Acceptable reliability of normalisation contractions in electromyography (EMG) is paramount for testing conducted over a number of days or if normal laboratory strength testing equipment is unavailable. This study examined the reliability of maximal voluntary isometric contractions (MVIC) and sub-maximal (60%) isometric contractions for use in neck muscle EMG studies. Surface EMG was recorded bilaterally from eight sites around the neck at C4/5 level from five healthy male subjects. Subjects performed MVIC and sub-maximal normalisation contractions using an isokinetic dynamometer (ID) and a portable cable dynamometer with attached strain gauge (PCD) in addition to a MVIC against a manual resistance (MR). Subjects were tested in flexion, extension, left and right lateral bending and were retested by the same tester within a two-week period. Intra class correlation co-efficients (ICC) were calculated for each testing method and contraction direction and a mean ICC was calculated across all contraction directions. All normalisation methods produced excellent within-day reliability (mean ICC >0.80) but only the MVICs using the ID and PCD had acceptable reliability when assessed between-days. This study confirmed the validity of using MVICs elicited using the ID and PCD as reliable reference contractions for the normalisation of neck EMG.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Regular resistance exercise completed for a number of weeks has been shown to increase insulin sensitivity and reduce the risk of diabetes-related complications. However, the acute responses to resistance exercise have not been adequately investigated in relation to training frequency.
AIM: To investigate the changes to insulin sensitivity in apparently healthy individuals following a single session of unaccustomed resistance exercise.
SUBJECTS AND METHODS: Ten sedentary, apparently healthy individuals performed a baseline oral glucose tolerance test and maximal strength testing. Participants then performed a single session of moderate-high intensity resistance exercise which was followed by 4 consecutive days of oral glucose tolerance testing, for which participants replicated their initial diet. Mean estimated insulin sensitivity change scores from baseline values and their 95% confidence intervals were compared to the previously determined values for a clinically meaningful change.
RESULTS: Two participants were identified as having hyperinsulinemia and their data were therefore removed from the main analysis. There was a clinically meaningful increase in insulin response (mean >7237 pmol·l⁻¹·120 min⁻¹) on all days following the exercise session and a clinically meaningful increase in glucose response (mean >81 mmol·l⁻¹·120 min⁻¹) on only the 3rd day following exercise. These changes suggest a potentially adverse short-term effect. Additionally, the 2 individuals with hyperinsulinemia displayed more extreme results.
CONCLUSION: These results suggest that insulin sensitivity may be impaired following a single session of unaccustomed resistance exercise for approximately 4 days in healthy untrained, older individuals. Further research is required for individuals with hyperinsulinemia

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The impact of prolonged bed rest on the cervical and upper thoracic spine is unknown. In the 2nd Berlin BedRest Study (BBR2-2), 24 male subjects underwent 60-day bed rest and performed either no exercise, resistive exercise, or resistive exercise with whole body vibration. Subjects were followed for 2 yr after bed rest. On axial cervical magnetic resonance images from the skull to T3, the volumes of the semispinalis capitis, splenius capitis, spinalis cervicis, longus capitis, longus colli, levator scapulae, sternocleidomastoid, middle and posterior scalenes, and anterior scalenes were measured. Disc height, anteroposterior width, and volume were measured from C2/3 to T6/7 on sagittal images. The volume of all muscles, with the exception of semispinalis capitis, increased during bed rest (P < 0.025). There were no significant differences between the groups for changes in the muscles. Increased upper and midthoracic spine disc height and volume (P < 0.001) was seen during bed rest, and disc height increases persisted at least 6 mo after bed rest. Increases in thoracic disc height were greater (P = 0.003) in the resistive vibration exercise group than in control. On radiological review, two subjects showed new injuries to the mid-lower thoracic spine. One of these subjects reported a midthoracic pain incident during maximal strength testing before bed rest and the other after countermeasure exercise on day 3 of bed rest. We conclude that bed rest is associated with increased disc size in the thoracic region and increases in muscle volume at the neck. The exercise device needs to be modified to ensure that load is distributed in a more physiological fashion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the effect of heat treatment on CrNi stainless steel orthodontic archwires. Half of forty archwires of each thickness - 0.014 (0.35 mm), 0.016 (0.40 mm), 0.018 (0.45 mm) and 0.020 (0.50 mm) (totalling 160 archwires) - were subjected to heat treatment while the remainder were not. All of the archwires had their individual thickness measured in the anterior and posterior regions using AutoCad 2000 software before and after compressive and tensile strength testing. The data was statistically analysed utilising multivariance ANOVA at a 5% significance level. All archwires without heat treatment that were subjected to tensile strength testing presented with anterior opening, which was more accentuated in the 0.020 archwires. In the posterior region, the opening produced by the tensile force was more accentuated in the archwires without heat treatment. There was greater stability in the thermally treated archwires, especially those subjected to tensile strength testing, which indicates that the heat treatment of orthodontic archwires establishes a favourable and indispensable condition to preserve the intercanine width.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To assess the effect of the composite surface conditioning on the microtensile bond strength of a resin cement to a composite used for inlay/onlay restorations.Materials and Methods: Forty-two blocks (6 x 6 x 4 mm) of a microfilled composite (Vita VMLC) were produced and divided into 3 groups (N = 14) by composite surface conditioning methods: Gr1 - etching with 37% phosphoric acid, washing, drying, silanization; Gr2 - air abrasion with 50-Im Al203 particles, silanization; Gr3 - chairside tribochemiCal silica coating (CoJet System), silanization. Single-Bond (one-step adhesive) was applied on the conditioned surfaces and the two resin blocks treated with the same method were cemented using RelyX ARC (dual-curing resin cement). The specimens were stored for 7 days in water at 37 degrees C and then sectioned to produce nontrimmed beam samples, which were submitted to microtensile bond strength testing (mu TBS). For statistical analysis (one-way ANOVA and Tukey's test, = 0.05), the means of the beam samples from each luted specimen were calculated (n = 7).Results: mu TBS values (MPa) of Gr2 (62.0 +/- 3.9a) and Gr3 (60.5 +/- 7.9a) were statistically similar to each other and higher than Gr1 (38.2 +/- 8.9b). The analysis of the fractured surfaces revealed that all failures occurred at the adhesive zone.Conclusion: Conditioning methods with 50-Im Al203 or tribochemical silica coating allowed bonding between resin and composite that was statistically similar and stronger than conditioning with acid etching.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This study evaluated the adhesive quality of simplified self-adhesive and conventional resin cements to Y-TZP in dry and aged conditions. Methods: Y-TZP ceramic blocks (N=192) (5 x 5 x 2 mm) were embedded in acrylic resin and randomly divided into two groups, based on surface conditioning: 96% isopropanol or chairside tribochemical silica coating and silanization. Conditioned ceramics were divided into four groups to receive the resin cements (Panavia F 2.0, Variolink II, RelyX U100 and Maxcem). After 24 hours, half of the specimens (n=12) from each group were submitted to shear bond strength testing (0.5 nun/minute). The remaining specimens were tested after 90 days of water storage at 37 degrees C and thermocycling (12,000x, 5 degrees C-55 degrees C). Failure types were then assessed. The data were analyzed using three-way ANOVA and the Tukey's test (alpha=0.05). Results: Significant effects of ceramic conditioning, cement type and storage conditions were observed (p<0.0001). The groups cleaned using alcohol only showed low bond strength values in dry conditions and the bond strength was reduced dramatically after aging. Groups conditioned using silica coating and silanization showed higher bond strengths both in dry and aged conditions. A high number of specimens failed prematurely prior to testing when they were cleaned using 96% isopropanol. Conclusion: Overall, silica coating and silanization showed higher, stable bond strengths with and without aging. The durability of resin-ceramic adhesion varied, depending on the adhesive cement type.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Since the use of air abrasion has grown in pediatric dentistry, the aim of this study was to evaluate, by means of shear bond strength testing, the need to use the total etching technique or self-etching primers on dentin of primary teeth after air abrasion. Twenty-five exfoliated primary molars had their occlusal dentin exposed by trimming and polishing. Specimens were treated by: Air abrasion + Scotchbond MultiPurpose adhesive (G1); 37% phosphoric acid + Scotchbond MP adhesive (G2); Clearfil SE (G3); Air abrasion ( 37% phosphoric acid + Scotchbond MP adhesive (G4); Air abrasion + Clearfil SE (G5). On the treated surface, a cylinder of 2 mm by 6 mm was made using a composite resin (Z100). Duncan's test showed that: (G2 = G3 = G5) > (G1 = G4). The use of a selfetching primer on air abraded dentin is recommended to obtain higher bond strengths.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To assess the effect of the composite surface conditioning on the microtensile bond strength of a resin cement to a composite used for inlay/onlay restorations. Materials and Methods: Forty-two blocks (6 × 6 × 4 mm) of a microfilled composite (Vita VMLC) were produced and divided into 3 groups (N = 14) by composite surface conditioning methods: Gr1 - etching with 37% phosphoric acid, washing, drying, silanization; Gr2 - air abrasion with 50-l̀m Al2O3 particles, silanization; Gr3 - chairside tribochemical silica coating (CoJet System), silanization. Single-Bond (one-step adhesive) was applied on the conditioned surfaces and the two resin blocks treated with the same method were cemented using RelyX ARC (dual-curing resin cement). The specimens were stored for 7 days in water at 37°C and then sectioned to produce nontrimmed beam samples, which were submitted to microtensile bond strength testing (μTBS). For statistical analysis (one-way ANOVA and Tukey's test, · = 0.05), the means of the beam samples from each luted specimen were calculated (n = 7). Results: μTBS values (MPa) of Gr2 (62.0 ± 3.9a) and Gr3 (60.5 ± 7.9a) were statistically similar to each other and higher than Gr1 (38.2 ± 8.9b). The analysis of the fractured surfaces revealed that all failures occurred at the adhesive zone. Conclusion: Conditioning methods with 50-l̀m Al2O3 or tribochemical silica coating allowed bonding between resin and composite that was statistically similar and stronger than conditioning with acid etching.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)