Stimulus artifacts inhibit reliable acquisition of biological evoked potentials for several milliseconds if an electrode contact is utilized for both electrical stimulation and recording purposes. This hinders the measurement of evoked short-latency biological responses, which is otherwise elicited by stimulation in implantable prosthetic devices. We present an improved stimulus artifact suppression scheme using two electrode simultaneous stimulation and differential readout using high-gain amplifiers. Substantial reduction of artifact duration has been shown possible through the common-mode rejection property of an instrumentation amplifier for electrode interfaces. The performance of this method depends on good matching of electrode-electrolyte interface properties of the chosen electrode pair. A novel calibration algorithm has been developed that helps in artificial matching of impedance and thereby achieves the required performance in artifact suppression. Stimulus artifact duration has been reduced down to 50 mu s from the stimulation-cum-recording electrodes, which is similar to 6x improvement over the present state of the art. The system is characterized with emulated resistor-capacitor loads and a variety of in-vitro metal electrodes dipped in saline environment. The proposed method is going to be useful for closed-loop electrical stimulation and recording studies, such as bidirectional neural prosthesis of retina, cochlea, brain, and spinal cord.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coupled-cavity passive harmonic mode-locking of a quantum well based vertical-external-cavity surface-emitting laser has been demonstrated, yielding an output pulse train of 1.5 ps pulses at a repetition rate of 80 GHz and with an average power of 80 mW. Harmonic mode-locking results from coupling between the main laser cavity and a cavity formed within the substrate of the saturable absorber structure. Mode-locking on the second harmonic of the substrate cavity allows a train of 1.1 ps pulses to be generated at a repetition rate of 147 GHz with 40 mW average power. © 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High repetition rate passively mode-locked sources are of significant interest due to their potential for applications including optical clocking, optical sampling, communications and others. Due to their short excited state lifetimes mode-locked VECSELs are ideally suited to high repetition rate operation, however fundamentally mode-locked quantum well-based VECSELs have not achieved repetition rates above 10 GHz due to the limitations placed on the cavity geometry by the requirement that the saturable absorber saturates more quickly than the gain. This issue has been overcome by the use of quantum dot-based saturable absorbers with lower saturation fluences leading to repetition rates up to 50 GHz, but sub-picosecond pulses have not been achieved at these repetition rates. We present a passively harmonically mode-locked VECSEL emitting pulses of 265 fs duration at a repetition rate of 169 GHz with an output power of 20 mW. The laser is based around an antiresonant 6 quantum well gain sample and is mode-locked using a semiconductor saturable absorber mirror. Harmonic modelocking is achieved by using an intracavity sapphire etalon. The sapphire then acts as a coupled cavity, setting the repetition rate of the laser while still allowing a tight focus on the saturable absorber. RF spectra of the laser output show no peaks at harmonics of the fundamental repetition rate up to 26 GHz, indicating stable harmonic modelocking. Autocorrelations reveal groups of pulses circulating in the cavity as a result of an increased tendency towards Q-switched modelocking due to the low pulse energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decades big improvements have been done in the field of computer aided learning, based on improvements done in computer science and computer systems. Although the field has been always a bit lagged, without using the latest solutions, it has constantly gone forward taking profit of the innovations as they show up. As long as the train of the computer science does not stop (and it won’t at least in the near future) the systems that take profit of those improvements will not either, because we humans will always need to study; Sometimes for pleasure and some other many times out of need. Not all the attempts in the field of computer aided learning have been in the same direction. Most of them address one or some few of the problems that show while studying and don’t take into account solutions proposed for some other problems. The reasons for this can be varied. Sometimes the solutions simply are not compatible. Some other times, because the project is an investigation it’s interesting to isolate the problem. And, in commercial products, licenses and patents often prevent the new projects to use previous work. The world moved forward and this is an attempt to use some of the options offered by technology, mixing some old ideas with new ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a two-stage Ti:sapphire amplifier system which can produce 17-TW/23-fs pulses at a repetition rate 10 MHz. A birefringent plate is used in the regenerative amplifier to alleviate gain narrowing, while an all-reflective cylindrical-mirror-based pulse stretcher and an acousto-optic programmable dispersive filter (AOPDF) are used to compensate for the higher order dispersion of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Repetition rate fluctuation is one of the main drawbacks of the low-threshold stimulated Brillouin scattering (SBS) Q-switched fiber laser. A method to stabilize the repetition rate is proposed in this paper by injecting a square-wave modulated light. It is measured experimentally that variance of the repetition rate can be improved from similar to 20% to similar to 1% of the period. It is also found that effectiveness of the method depends on modulation frequency and duty cycle of the injection. Its working mechanism is analyzed qualitatively. (C) 2009 Optical Society of America