986 resultados para steam generator


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, a thermoeconomic functional analysis method based on the Second Law of Thermodynamics and applied to analyze four cogeneration systems is presented. The objective of the developed technique is to minimize the operating costs of the cogeneration plant, namely exergetic production cost (EPC), assuming fixed rates of electricity production and process steam in exergy base. In this study a comparison is made between the same four configurations of part I. The cogeneration system consisting of a gas turbine with a heat recovery steam generator, without supplementary firing, has the lowest EPC. (C) 2004 Published by Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work it was performed energetic and exergetic analyses of three thermal plants to assessment a cogeneration system in expansion of a sugar-alcohol factory. The initial configuration considered is constituted by a low pressure steam generator, single stage steam turbines for electricity generation and crusher, shredder and mills with mechanical driving. In the intermediary configuration, the low pressure steam generator was substituted by another which generates steam at higher pressure and higher temperature, the steam turbines for electricity generation were substituted by a multiple stages extraction-condensation turbine and the other steam turbines were maintained. The final configuration consists in the substitution of these last turbines by electrical motors. Thermodynamic analyses were performed to evaluate the equipment and the overall plants efficiencies to permit a comparison among the plants. Besides of this, some important parameters of the sugar-alcohol factories were calculated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper we present technical and economic studies of cogeneration systems utilizing combustion engines and gas turbines, applied in two establishments of the tertiary sector, regarding Brazilian conditions (according to Silveria, 1994). In the first step cogeneration systems utilizing combustion engines associated to absorption refrigeration systems are studied, in which electricity and cold air for a university building rate produced. In the second step some possibilities of the use of the gas turbine in cogeneration systems for a hospital are shown. In this case, the exhaust gases are utilized for the production of steam in a heat recovery steam generator (HRSG) or cold water in an absorption refrigeration system (for air conditioning) for the hospital building. The dynamic increment of the energy demand of Brazilian tertiary sector in last years can increase the installation of these cogeneration system (in compact version) as well as strengthen the development of the decentralized energy generation in Brazil.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The discussion about possibility of deployment of MSW incineration boilers to generate electricity in Brazil is the major topic of this paper. In this article are showed some advantages and disadvantages of this technology, as well as a methodology for the estimate of area for the main equipments of a steam generator for a boiler incineration

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El accidente de rotura de tubos de un generador de vapor (Steam Generator Tube Rupture, SGTR) en los reactores de agua a presión es uno de los transitorios más exigentes desde el punto de vista de operación. Los transitorios de SGTR son especiales, ya que podría dar lugar a emisiones radiológicas al exterior sin necesidad de daño en el núcleo previo o sin que falle la contención, ya que los SG pueden constituir una vía directa desde el reactor al medio ambiente en este transitorio. En los análisis de seguridad, el SGTR se analiza desde un punto determinista y probabilista, con distintos enfoques con respecto a las acciones del operador y las consecuencias analizadas. Cuando comenzaron los Análisis Deterministas de Seguridad (DSA), la forma de analizar el SGTR fue sin dar crédito a la acción del operador durante los primeros 30 min del transitorio, lo que suponía que el grupo de operación era capaz de detener la fuga por el tubo roto dentro de ese tiempo. Sin embargo, los diferentes casos reales de accidentes de SGTR sucedidos en los EE.UU. y alrededor del mundo demostraron que los operadores pueden emplear más de 30 minutos para detener la fuga en la vida real. Algunas metodologías fueron desarrolladas en los EEUU y en Europa para abordar esa cuestión. En el Análisis Probabilista de Seguridad (PSA), las acciones del operador se tienen en cuenta para diseñar los cabeceros en el árbol de sucesos. Los tiempos disponibles se utilizan para establecer los criterios de éxito para dichos cabeceros. Sin embargo, en una secuencia dinámica como el SGTR, las acciones de un operador son muy dependientes del tiempo disponible por las acciones humanas anteriores. Además, algunas de las secuencias de SGTR puede conducir a la liberación de actividad radiológica al exterior sin daño previo en el núcleo y que no se tienen en cuenta en el APS, ya que desde el punto de vista de la integridad de núcleo son de éxito. Para ello, para analizar todos estos factores, la forma adecuada de analizar este tipo de secuencias pueden ser a través de una metodología que contemple Árboles de Sucesos Dinámicos (Dynamic Event Trees, DET). En esta Tesis Doctoral se compara el impacto en la evolución temporal y la dosis al exterior de la hipótesis más relevantes encontradas en los Análisis Deterministas a nivel mundial. La comparación se realiza con un modelo PWR Westinghouse de tres lazos (CN Almaraz) con el código termohidráulico TRACE, con hipótesis de estimación óptima, pero con hipótesis deterministas como criterio de fallo único o pérdida de energía eléctrica exterior. Las dosis al exterior se calculan con RADTRAD, ya que es uno de los códigos utilizados normalmente para los cálculos de dosis del SGTR. El comportamiento del reactor y las dosis al exterior son muy diversas, según las diferentes hipótesis en cada metodología. Por otra parte, los resultados están bastante lejos de los límites de regulación, pese a los conservadurismos introducidos. En el siguiente paso de la Tesis Doctoral, se ha realizado un análisis de seguridad integrado del SGTR según la metodología ISA, desarrollada por el Consejo de Seguridad Nuclear español (CSN). Para ello, se ha realizado un análisis termo-hidráulico con un modelo de PWR Westinghouse de 3 lazos con el código MAAP. La metodología ISA permite la obtención del árbol de eventos dinámico del SGTR, teniendo en cuenta las incertidumbres en los tiempos de actuación del operador. Las simulaciones se realizaron con SCAIS (sistema de simulación de códigos para la evaluación de la seguridad integrada), que incluye un acoplamiento dinámico con MAAP. Las dosis al exterior se calcularon también con RADTRAD. En los resultados, se han tenido en cuenta, por primera vez en la literatura, las consecuencias de las secuencias en términos no sólo de daños en el núcleo sino de dosis al exterior. Esta tesis doctoral demuestra la necesidad de analizar todas las consecuencias que contribuyen al riesgo en un accidente como el SGTR. Para ello se ha hecho uso de una metodología integrada como ISA-CSN. Con este enfoque, la visión del DSA del SGTR (consecuencias radiológicas) se une con la visión del PSA del SGTR (consecuencias de daño al núcleo) para evaluar el riesgo total del accidente. Abstract Steam Generator Tube Rupture accidents in Pressurized Water Reactors are known to be one of the most demanding transients for the operating crew. SGTR are special transient as they could lead to radiological releases without core damage or containment failure, as they can constitute a direct path to the environment. The SGTR is analyzed from a Deterministic and Probabilistic point of view in the Safety Analysis, although the assumptions of the different approaches regarding the operator actions are quite different. In the beginning of Deterministic Safety Analysis, the way of analyzing the SGTR was not crediting the operator action for the first 30 min of the transient, assuming that the operating crew was able to stop the primary to secondary leakage within that time. However, the different real SGTR accident cases happened in the USA and over the world demonstrated that operators can took more than 30 min to stop the leakage in actual sequences. Some methodologies were raised in the USA and in Europe to cover that issue. In the Probabilistic Safety Analysis, the operator actions are taken into account to set the headers in the event tree. The available times are used to establish the success criteria for the headers. However, in such a dynamic sequence as SGTR, the operator actions are very dependent on the time available left by the other human actions. Moreover, some of the SGTR sequences can lead to offsite doses without previous core damage and they are not taken into account in PSA as from the point of view of core integrity are successful. Therefore, to analyze all this factors, the appropriate way of analyzing that kind of sequences could be through a Dynamic Event Tree methodology. This Thesis compares the impact on transient evolution and the offsite dose of the most relevant hypothesis of the different SGTR analysis included in the Deterministic Safety Analysis. The comparison is done with a PWR Westinghouse three loop model in TRACE code (Almaraz NPP), with best estimate assumptions but including deterministic hypothesis such as single failure criteria or loss of offsite power. The offsite doses are calculated with RADTRAD code, as it is one of the codes normally used for SGTR offsite dose calculations. The behaviour of the reactor and the offsite doses are quite diverse depending on the different assumptions made in each methodology. On the other hand, although the high conservatism, such as the single failure criteria, the results are quite far from the regulatory limits. In the next stage of the Thesis, the Integrated Safety Assessment (ISA) methodology, developed by the Spanish Nuclear Safety Council (CSN), has been applied to a thermohydraulical analysis of a Westinghouse 3-loop PWR plant with the MAAP code. The ISA methodology allows obtaining the SGTR Dynamic Event Tree taking into account the uncertainties on the operator actuation times. Simulations are performed with SCAIS (Simulation Code system for Integrated Safety Assessment), which includes a dynamic coupling with MAAP thermal hydraulic code. The offsite doses are calculated also with RADTRAD. The results shows the consequences of the sequences in terms not only of core damage but of offsite doses. This Thesis shows the need of analyzing all the consequences in an accident such as SGTR. For that, an it has been used an integral methodology like ISA-CSN. With this approach, the DSA vision of the SGTR (radiological consequences) is joined with the PSA vision of the SGTR (core damage consequences) to measure the total risk of the accident.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El objetivo del presente proyecto consiste en la modelización y optimización de una planta de gasificación integrada en ciclo combinado de 400 MW de potencia neta, mediante el uso del programa Cycle-Tempo, desarrollado por la Universidad de Delft. Para la modelización de la planta, se ha dividido en sus dos unidades principales: la isla de gasificación y el ciclo combinado. Para la validación del modelo de la isla de gasificación, se ha utilizado una composición de referencia de un combustible gasificable y se ha obtenido la composición del gas de síntesis esperada. Se han modelado y optimizado varias configuraciones de ciclo combinado, variando los parámetros característicos de la caldera de recuperación de calor. Se ha realizado la integración de las dos unidades para maximizar la potencia entregada por la planta. Finalmente, se ha estimado el balance anual de energía del ciclo combinado alimentado con gas natural y con el gas de síntesis, con el fin de comparar las rentabilidades económicas obtenidas. Mediante el estudio realizado, se deduce que la forma más eficiente de producir energía, a partir del uso del carbón, es la tecnología de gasificación integrada en ciclo combinado, pese a que su rendimiento sea inferior al ciclo combinado alimentado con gas natural. ABSTRACT The aim of this project is the modeling and optimization of an integrated gasification combined cycle plant of 400 MW net power, using the Cycle-Tempo program, developed by the University of Delft. For the modeling of the plant, it has been divided into its two main units: the island of gasification and the combined cycle. For the model validation of the gasification island, a reference composition of a gasifiable fuel has been used and the expected synthesis gas composition was obtained. Several configurations of combined cycle have been modeled and optimized by varying the characteristic parameters of the heat recovery steam generator. It has made the integration of the two units to reach maximum optimization of power, which has been delivered by the plant. Finally, it has been estimated the annual energy balance for the combined cycle plant fueled with natural gas and with syngas, in order to compare the profitability obtained with each one. Through the study, it is deduced that the most efficient way to produce energy from the use of coal, is the integrated gasification combined cycle technology, although their performance is lower than that obtained from the combined cycle fueled with natural gas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A Steam Generator Tube Rupture (SGTR) in a Pressurized Water Reactor (PWR) can lead to an atmospheric release bypassing the containment via the secondary system and exiting though the Pressurized Operating Relief Valves of the affected Steam Generator. That is why SGTR historically have been treated in a special way in the different Deterministic Safety Analysis (DSA), focusing on the radioactive release more than the possibility of core damage, as it is done in the other Loss of Coolant Accidents(LOCAs).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Steam Generator Tube Rupture (SGTR) sequences in Pressurized Water Reactors are known to be one of the most demanding transients for the operating crew. SGTR are a special kind of transient as they could lead to radiological releases without core damage or containment failure, as they can constitute a direct path from the reactor coolant system to the environment. The first methodology used to perform the Deterministic Safety Analysis (DSA) of a SGTR did not credit the operator action for the first 30 min of the transient, assuming that the operating crew was able to stop the primary to secondary leakage within that period of time. However, the different real SGTR accident cases happened in the USA and over the world demonstrated that the operators usually take more than 30 min to stop the leakage in actual sequences. Some methodologies were raised to overcome that fact, considering operator actions from the beginning of the transient, as it is done in Probabilistic Safety Analysis. This paper presents the results of comparing different assumptions regarding the single failure criteria and the operator action taken from the most common methodologies included in the different Deterministic Safety Analysis. One single failure criteria that has not been analysed previously in the literature is proposed and analysed in this paper too. The comparison is done with a PWR Westinghouse three loop model in TRACE code (Almaraz NPP) with best estimate assumptions but including deterministic hypothesis such as single failure criteria or loss of offsite power. The behaviour of the reactor is quite diverse depending on the different assumptions made regarding the operator actions. On the other hand, although there are high conservatisms included in the hypothesis, as the single failure criteria, all the results are quite far from the regulatory limits. In addition, some improvements to the Emergency Operating Procedures to minimize the offsite release from the damaged SG in case of a SGTR are outlined taking into account the offsite dose sensitivity results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dado el impacto negativo asociado a la ocurrencia de fallas en tubos de generadores de vapor (TGVs) en centrales nucleares, el estudio de la integridad estructural de éstos ha comenzado a recibir mayor atención recientemente. Diversas metodologías basadas en análisis de carga límite han sido propuestas para asegurar la integridad estructural de los tubos, según los requerimientos establecidos por las autoridades regulatorias. Éstas han conducido, sin embargo, a la definición de criterios de reparación o taponado de TGVs excesivamente conservativos. Por lo tanto, con el objetivo de reducir la cantidad de tubos innecesariamente removidos de servicio, nuevos criterios de evaluación de integridad han sido propuestos recientemente en la literatura. En este contexto, la mecánica de fractura elastoplástica se presenta como una alternativa para la evaluación de la integridad de TGVs, requiriéndose dos elementos para su aplicación: la estimación de la fuerza impulsora en términos del parámetro elastoplástico (por ejemplo, la integral J) y la medición experimental de la tenacidad a la fractura del material de los tubos (por ejemplo, a través de la curva de resistencia J-R). Este trabajo presenta el desarrollo de técnicas experimentales no normalizadas para la determinación de curvas J-R para TGVs con fisuras pasantes circunferenciales y longitudinales. Debido a las dimensiones reducidas de los TGVs, diferentes probetas no normalizadas fueron propuestas. Además, en los ensayos se utilizaron condiciones de carga de tracción y flexión con el objetivo de modelar más adecuadamente los estados tensionales y las condiciones de constraint reales en TGVs. Los valores de la integral J fueron estimados utilizando el método del factor η. La aptitud del método fue evaluada a partir de simulaciones numéricas de los ensayos propuestos mediante análisis elastoplásticos con la técnica de elementos finitos. Se encontró que condiciones de mayor constraint asociadas con fisuras profundas y cargas de flexión favorecen la validez del método del factor η, mientras que configuraciones de menor constraint dan como resultado factores η que exhiben una mayor dependencia con el nivel de carga aplicada. También se observó que los factores η basados en la apertura de la boca de la fisura (Crack Mouth Opening Displacement o CMOD) presentan una dependencia mucho menor con el nivel de carga respecto a los factores η definidos a partir del desplazamiento del punto de aplicación de la carga (Load Line Displacement o LLD). Se presentan los valores del factor η para las probetas estudiadas con fisuras profundas (a/W ≥ 0,40). Se realizaron ensayos de fractura a temperatura ambiente y 300 °C con probetas obtenidas de TGVs nucleares fabricados a partir de las aleaciones 690 (Ni: 61; Cr: 29; Fe: 8,95, % en peso) y 800 (Ni: 33; Cr: 21,6; Fe: 42,2, % en peso). Durante los ensayos de fractura a temperatura ambiente, la extensión estable de fisura fue medida mediante una técnica óptica utilizando un microscopio digital. Para estos ensayos también se aplicó el método de normalización que propone la norma ASTM E1820-15 en el Anexo 15, encontrándose una buena coincidencia entre las longitudes estimadas por éste y las medidas ópticamente. De esta manera, el método de normalización fue utilizado para los ensayos a alta temperatura. Los resultados experimentales mostraron que ambos materiales tienen elevadas tenacidades a la fractura, siendo la aleación 800 la que presentó curvas J-R más elevadas que la aleación 690 tanto para fisuras circunferenciales como longitudinales. Las curvas J-R para ambas aleaciones mostraron un efecto marcado con la orientación de la fisura, es decir que existe una importante anisotropía en las propiedades de fractura: las fisuras circunferenciales presentaron curvas J-R más elevadas que las fisuras longitudinales. El nivel de constraint desarrollado en los ensayos, dado por las condiciones de carga de tracción y flexión, evidenció poco efecto sobre las curvas J-R para probetas con fisuras profundas (a/W ~ 0,50). A su vez, la temperatura de ensayo (temperatura ambiente y 300 °C) presentó un efecto prácticamente nulo para ambas aleaciones. Usando las propiedades de fractura obtenidas en este trabajo, la metodología FAD (Failure Assessment Diagram) fue propuesta y utilizada para la predicción de las condiciones de falla de TGVs fisurados para diferentes geometrías de fisura y condiciones de carga. La comparación entre análisis teóricos y datos experimentales muestra la potencialidad del FAD como una metodología capaz de predecir adecuadamente las fallas de estos componentes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dado el impacto negativo asociado a la ocurrencia de fallas en tubos de generadores de vapor (TGVs) en centrales nucleares, el estudio de la integridad estructural de éstos ha comenzado a recibir mayor atención recientemente. Diversas metodologías basadas en análisis de carga límite han sido propuestas para asegurar la integridad estructural de los tubos, según los requerimientos establecidos por las autoridades regulatorias. Éstas han conducido, sin embargo, a la definición de criterios de reparación o taponado de TGVs excesivamente conservativos. Por lo tanto, con el objetivo de reducir la cantidad de tubos innecesariamente removidos de servicio, nuevos criterios de evaluación de integridad han sido propuestos recientemente en la literatura. En este contexto, la mecánica de fractura elastoplástica se presenta como una alternativa para la evaluación de la integridad de TGVs, requiriéndose dos elementos para su aplicación: la estimación de la fuerza impulsora en términos del parámetro elastoplástico (por ejemplo, la integral J) y la medición experimental de la tenacidad a la fractura del material de los tubos (por ejemplo, a través de la curva de resistencia J-R). Este trabajo presenta el desarrollo de técnicas experimentales no normalizadas para la determinación de curvas J-R para TGVs con fisuras pasantes circunferenciales y longitudinales. Debido a las dimensiones reducidas de los TGVs, diferentes probetas no normalizadas fueron propuestas. Además, en los ensayos se utilizaron condiciones de carga de tracción y flexión con el objetivo de modelar más adecuadamente los estados tensionales y las condiciones de constraint reales en TGVs. Los valores de la integral J fueron estimados utilizando el método del factor η. La aptitud del método fue evaluada a partir de simulaciones numéricas de los ensayos propuestos mediante análisis elastoplásticos con la técnica de elementos finitos. Se encontró que condiciones de mayor constraint asociadas con fisuras profundas y cargas de flexión favorecen la validez del método del factor η, mientras que configuraciones de menor constraint dan como resultado factores η que exhiben una mayor dependencia con el nivel de carga aplicada. También se observó que los factores η basados en la apertura de la boca de la fisura (Crack Mouth Opening Displacement o CMOD) presentan una dependencia mucho menor con el nivel de carga respecto a los factores η definidos a partir del desplazamiento del punto de aplicación de la carga (Load Line Displacement o LLD). Se presentan los valores del factor η para las probetas estudiadas con fisuras profundas (a/W ≥ 0,40). Se realizaron ensayos de fractura a temperatura ambiente y 300 °C con probetas obtenidas de TGVs nucleares fabricados a partir de las aleaciones 690 (Ni: 61; Cr: 29; Fe: 8,95, % en peso) y 800 (Ni: 33; Cr: 21,6; Fe: 42,2, % en peso). Durante los ensayos de fractura a temperatura ambiente, la extensión estable de fisura fue medida mediante una técnica óptica utilizando un microscopio digital. Para estos ensayos también se aplicó el método de normalización que propone la norma ASTM E1820-15 en el Anexo 15, encontrándose una buena coincidencia entre las longitudes estimadas por éste y las medidas ópticamente. De esta manera, el método de normalización fue utilizado para los ensayos a alta temperatura. Los resultados experimentales mostraron que ambos materiales tienen elevadas tenacidades a la fractura, siendo la aleación 800 la que presentó curvas J-R más elevadas que la aleación 690 tanto para fisuras circunferenciales como longitudinales. Las curvas J-R para ambas aleaciones mostraron un efecto marcado con la orientación de la fisura, es decir que existe una importante anisotropía en las propiedades de fractura: las fisuras circunferenciales presentaron curvas J-R más elevadas que las fisuras longitudinales. El nivel de constraint desarrollado en los ensayos, dado por las condiciones de carga de tracción y flexión, evidenció poco efecto sobre las curvas J-R para probetas con fisuras profundas (a/W ~ 0,50). A su vez, la temperatura de ensayo (temperatura ambiente y 300 °C) presentó un efecto prácticamente nulo para ambas aleaciones. Usando las propiedades de fractura obtenidas en este trabajo, la metodología FAD (Failure Assessment Diagram) fue propuesta y utilizada para la predicción de las condiciones de falla de TGVs fisurados para diferentes geometrías de fisura y condiciones de carga. La comparación entre análisis teóricos y datos experimentales muestra la potencialidad del FAD como una metodología capaz de predecir adecuadamente las fallas de estos componentes.