941 resultados para standard crane
Resumo:
Bleeding is not uncommon following endoscopic sphincterotomy. Supra-papillary puncture (SPP) might be safer than standard cannulation (SC) techniques in patients with coagulopathy. The aim of the study was to compare the safety and effectiveness of SPP and SC. This was a prospective case control intervention study. Decompensated cirrhotic patients with coagulopathy and choledocolithiasis underwent SC and SPP methods for biliary access. One hundred five patients (56 [53.3%] men, mean [SD] age 56 [15.8]) underwent ERCP. SC and SPP were performed in 63 and 42 patients, respectively. Biliary access was achieved in 56/63 (89%) and 40/42 (95%) of patients undergoing SC and SPP, respectively (P = 0.13; 95% CI [-0.16; 0.03]). Complications occurred in 10/63 (15.8%) patients undergoing SC and 5/42 (11.9%) SPP (P = 0.28; 95% CI [-0.17, 0.16]). Five (7.9%) and two (3.2%) episodes of post-sphincterotomy bleeding was seen in the SC and SPP groups, respectively (P = 0.36; 95% CI [-0.16, 0.05]). In contrast, three (4.8%) episodes of pancreatitis were seen in the SC and none in the SPP group (P = 0.05; 95% CI [0.001; 0.004]). A cost-effectiveness analysis demonstrated that SPP is an acceptable alternative at an ICER of US$ 5,974.92 per additional successful procedure. SPP is a safe and effective technique for the management of common bile duct stones in decompensated cirrhotic patients. Conditional to the willingness-to-pay and to the local ERCP-related costs, SPP is also a cost-effective alternative to the SC methods. SPP is associated with a lower rate of complications but larger studies to validate these findings are necessary.
Resumo:
Objectives Low doses of ACTH [1-24] (0.1, 0.5 and 1.0 mug per 1.73 m(2)) may provide a more physiological level of adrenal stimulation than the standard 250 mug test, but not all studies have concluded that the 1.0 fig is a more sensitive screening test for central hypoadrenalism. Eight-hour infusions of high dose ACTH [1-24] have also been suggested as a means of assessing the adrenals' capacity for sustained cortisol secretion. In this study, we compared the diagnostic accuracy of three low dose ACTH tests (LDTs) and the 8-h infusion with the standard 250 jig test (HDT) and the insulin hypoglycaemia test (IHT) in patients with hypothalamic-pituitary disease. Subjects and design Three groups of subjects were studied. A healthy control group (group 1, n=9) and 33 patients with known hypothalamic or pituitary disease who were divided into group 2 (n=12, underwent IHT) and group 3 (n=21, IHT contraindicated). Six different tests were performed: a standard IHT (0.15 U/kg soluble insulin); a 60-minute 250 mug HDT; three different LDTs using 0.1 mug, 0.5 mug and 1.0 mug (all per 1.73 m(2)); and an 8-h infusion test (250 mug ACTH [1-24] at a constant rate over 8 h). Results Nine out of the 12 patients in group 2 failed the IHT. Three out of 12 patients from group 2 who clearly passed the IHT, also passed all the ACTH [1-24] stimulation tests. Seven of the 9 patients who failed the lHT, failed by a clear margin (peak cortisol
Resumo:
Despite evidence linking shrimp farming to several cases of environmental degradation, there remains a lack of ecologically meaningful information about the impacts of effluent on receiving waters. The aim of this study was to determine the biological impact of shrimp farm effluent, and to compare and distinguish its impacts from treated sewage effluent. Analyses included standard water quality/sediment parameters, as well as biological indicators including tissue nitrogen (N) content, stable isotope ratio of nitrogen (delta N-15) and amino acid composition of inhabitant seagrasses, mangroves and macroalgae. The study area consisted of two tidal creeks, one receiving effluent from a sewage treatment plant and the other from an intensive shrimp farm. The creeks discharged into the western side of Moreton Bay, a sub-tropical coastal embayment on the east coast of Australia. Characterization of water quality revealed significant differences between the creeks, and with unimpacted eastern Moreton Bay. The sewage creek had higher concentrations of dissolved nutrients (predominantly NO3-/NO2- and PO43-, compared to NH4+ in the shrimp creek). In contrast, the shrimp creek was more turbid and had higher phytoplankton productivity. Beyond 750 m from the creek mouths, water quality parameters were indistinguishable from eastern Moreton Bay values. Biological indicators detected significant impacts up to 4 km beyond the creek mouths (reference site). Elevated plant delta N-15 values ranged from 10.4-19.6 parts per thousand at the site of sewage discharge to 2.9-4.5 parts per thousand at the reference site. The free amino acid concentration and composition of seagrass and macroalgae was used to distinguish between the uptake of sewage and shrimp derived N. Proline (seagrass) and serine (macroalgae) were high in sewage impacted plants and glutamine (seagrass) and alanine (macroalgae) were high in plants impacted by shrimp effluent. The delta N-15 isotopic signatures and free amino acid composition of inhabitant flora indicated that sewage N extended further from the creek mouths than shrimp N. The combination of physical/chemical and biological indicators used in this study was effective in distinguishing the composition and subsequent impacts of aquaculture and sewage effluent on the receiving waters. (C) 2001 Academic Press.
Resumo:
By exhibiting a violation of a novel form of the Bell-CHSH inequality, Żukowski has recently established that the quantum correlations exploited in the standard perfect teleportation protocol cannot be recovered by any local hidden variables model. In the case of imperfect teleportation, we show that a violation of a generalized form of Żukowski's teleportation inequality can only occur if the channel state, considered by itself, already violates a Bell-CHSH inequality. On the other hand, the fact that the channel state violates a Bell-CHSH inequality is not sufficient to imply a violation of Żukowski's teleportation inequality (or any of its generalizations). The implication does hold, however, if the fidelity of the teleportation exceeds ≈ 0.90. © 2001 Elsevier Science B.V. All rights reserved.
Resumo:
LUDA is a research project of Key Action 4 "City of Tomorrow & Cultural Heritage" of the programme "Energy, Environment and Sustainable Development" within the Fifth Framework Programme of the European Commission
Resumo:
We study the implications of the searches based on H -> tau(+)tau-by the ATLAS and CMS collaborations on the parameter space of the two-Higgs-doublet model (2HDM). In the 2HDM, the scalars can decay into a tau pair with a branching ratio larger than the SM one, leading to constraints on the 2HDM parameter space. We show that in model II, values of tan beta > 1.8 are definitively excluded if the pseudoscalar is in the mass range 110 GeV < m(A) < 145 GeV. We have also discussed the implications for the 2HDM of the recent dimuon search by the ATLAS collaboration for a CP-odd scalar in the mass range 4-12 GeV.
The use of non-standard CT conversion ramps for Monte Carlo verification of 6 MV prostate IMRT plans
Resumo:
Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.