960 resultados para spectral leakage
Resumo:
We study the spectral and noise properties of the fluorescence field emitted from a two-level atom driven by a beam of squeezed light. For a weak driving field we derive simple analytical formulae for the fluorescence and quadrature-noise spectra which are valid for an arbitrary bandwidth of the squeezed field. We analyse the spectra in the regime where the squeezing bandwidth is smaller or comparable to the atomic linewidth, the area where non-Markovian effects are important. We emphasize that there is a noticable difference between the fluorescence spectra for the thermal and squeezed field excitations. In both cases the spectrum can be narrower than any bandwidth involved in the process. However, as we point out for the squeezed driving field the linewidth narrowing, being much larger than in the thermal-field case, can be attributed to the squeezing of the fluctuations in the driving held. We also calculate the quadrature-noise spectrum of the emitted fluorescence, and find that for a detuned squeezed field the fluorescence spectrum does not reveal the quadrature-noise spectrum. In contrast to the fluorescence spectrum having two peaks, the quadrature-noise spectrum exhibits three peaks. We explain this difference as arising from the competiting three-photon scattering processes. (C) 1998 Elsevier Science B.V. All rights reserved.
Resumo:
The compound eyes of mantis shrimps (stomatopod crustaceans) include an unparalleled diversity of visual pigments and spectral receptor classes in retinas of each species. We compared the visual pigment and spectral receptor classes of 12 species of gonodactyloid stomatopods from a variety of photo environments, from intertidal to deep water ( > 50 m), to learn how spectral tuning in the different photoreceptor types is modified within different photic environments. Results show that receptors of the peripheral photoreceptors, those outside the midband which are responsible for standard visual tasks such as spatial vision and motion detection, reveal the well-known pattern of decreasing lambda(max) with increasing depth. Receptors of midband rows 5 and 6, which are specialized for polarization vision, are similar in all species, having visual lambda(max)-values near 500 nm, independent of depth. Finally the spectral receptors of midband rows 1 to 4 are tuned for maximum coverage of the spectrum of irradiance available in the habitat of each species. The quality of the visual worlds experienced by each species we studied must vary considerably, but all appear to exploit the full capabilities offered by their complex visual systems.
Resumo:
We develop a test of evolutionary change that incorporates a null hypothesis of homogeneity, which encompasses time invariance in the variance and autocovariance structure of residuals from estimated econometric relationships. The test framework is based on examining whether shifts in spectral decomposition between two frames of data are significant. Rejection of the null hypothesis will point not only to weak nonstationarity but to shifts in the structure of the second-order moments of the limiting distribution of the random process. This would indicate that the second-order properties of any underlying attractor set has changed in a statistically significant way, pointing to the presence of evolutionary change. A demonstration of the test's applicability to a real-world macroeconomic problem is accomplished by applying the test to the Australian Building Society Deposits (ABSD) model.
Resumo:
A graph clustering algorithm constructs groups of closely related parts and machines separately. After they are matched for the least intercell moves, a refining process runs on the initial cell formation to decrease the number of intercell moves. A simple modification of this main approach can deal with some practical constraints, such as the popular constraint of bounding the maximum number of machines in a cell. Our approach makes a big improvement in the computational time. More importantly, improvement is seen in the number of intercell moves when the computational results were compared with best known solutions from the literature. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Al-catechin/beta-cyclodextrin and Al-quercetin/beta-cyclodextrin (beta-CD) inclusion compounds were synthesized and characterized by IR, UV-vis, H-1 and C-13 NMR and TG and DTA analyses. Because quercetin is sparingly soluble in water, the stability constants of the Al-quercetin/beta-CD and Al-catechin/beta-CD compounds were determined by phase solubility studies. The A(L)-type diagrams indicated the formation of 1:1 inclusion compounds and allowed calculation of the stability constants. The thermodynamic parameters were obtained from the dependence of the stability constants on temperature and results indicated that the formation of the inclusion compounds is an enthalpically driven process. The thermal decomposition of the solid Al-quercetin/beta-CD and Al-catcchin/beta-CD inclusion compounds took place at different stages, compared with the respective precursors, proving that an inclusion complexation process really occurred. (C) 2007 Published by Elsevier B.V.
Resumo:
In this article we present a complete (1)H and (13)C NMR spectral analysis of three 7,7`-dihydroarylnaphthalene lignan lactones using modern NMR techniques such as COSY, HSQC, HMBC and NOE experiments. Complete assignment and homonuclear hydrogen coupling constant measurements were performed. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
The fluorescence spectrum of a strongly driven two-level atom located inside an optical cavity damped by a narrow-bandwidth squeezed vacuum is studied. We use a dressed atom model approach, first applied to squeezed vacuum problems by Yeoman and Barnett, to derive the master equation of the system and discuss the role of the cavity and the squeezed vacuum in the narrowing of the spectral lines and the population trapping effect. We find that in the presence of a single-mode cavity the effect of squeezing on the fluorescence spectrum is more evident in the linewidths of the Rabi sidebands rather than in the linewidth of the central component. Even in the absence of squeezing, the cavity can reduce the linewidth of the central component almost to zero, whereas the Rabi sidebands can be narrowed only to some finite value. In the presence of a two-mode cavity and a two-mode squeezed vacuum the signature of squeezing is evident in the linewidths of all spectral lines. We also establish that the narrowing of the spectral lines is very sensitive to the detuning of the driving field from the atomic resonance. Moreover, we find that the population trapping effect, predicted for the broadband squeezed vacuum case, may appear in a narrow-bandwidth case only if the input squeezed modes are perfectly matched to the cavity modes and if there is non-zero squeezing at the Rabi sidebands.
Resumo:
Olm MA, Kogler JE Jr, Macchione M, Shoemark A, Saldiva PH, Rodrigues JC. Primary ciliary dyskinesia: evaluation using cilia beat frequency assessment via spectral analysis of digital microscopy images. J Appl Physiol 111: 295-302, 2011. First published May 5, 2011; doi:10.1152/japplphysiol.00629.2010.-Ciliary beat frequency (CBF) measurements provide valuable information for diagnosing of primary ciliary dyskinesia (PCD). We developed a system for measuring CBF, used it in association with electron microscopy to diagnose PCD, and then analyzed characteristics of PCD patients. 1 The CBF measurement system was based on power spectra measured through digital imaging. Twenty-four patients suspected of having PCD (age 1-19 yr) were selected from a group of 75 children and adolescents with pneumopathies of unknown causes. Ten healthy, nonsmoking volunteers (age >= 17 yr) served as a control group. Nasal brush samples were collected, and CBF and electron microscopy were performed. PCD was diagnosed in 12 patients: 5 had radial spoke defects, 3 showed absent central microtubule pairs with transposition, 2 had outer dynein arm defects, 1 had a shortened outer dynein arm, and 1 had a normal ultrastructure. Previous studies have reported that the most common cilia defects are in the dynein arm. As expected, the mean CBF was higher in the control group (P < 0.001) and patients with normal ultrastructure (P < 0.002), than in those diagnosed with cilia ultrastructural defects (i.e., PCD patients). An obstructive ventilatory pattern was observed in 70% of the PCD patients who underwent pulmonary function tests. All PCD patients presented bronchial wall thickening on chest computed tomography scans. The protocol and diagnostic techniques employed allowed us to diagnose PCD in 16% of patients in this study.
Resumo:
PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516
Resumo:
Background: Posterior reconstruction (PR) of the rhabdosphincter has been previously described during retropubic radical prostatectomy, and shorter times to return of urinary continence were reported using this technical modification. This technique has also been applied during robot-assisted radical prostatectomy (RARP); however, contradictory results have been reported. Objective: We describe here a modified technique for PR of the rhabdosphincter during RARP and report its impact on early recovery of urinary continence and on cystographic leakage rates. Design, setting, and participants: We analyzed 803 consecutive patients who underwent RARP by a single surgeon over a 12-mo period: 330 without performing PR and 473 with PR. Surgical procedure: The reconstruction was performed using two 6-in 3-0 Poliglecaprone sutures tied together. The free edge of the remaining Denonvillier`s fascia was identified after prostatectomy and approximated to the posterior aspect of the rhabdosphincter and the posterior median raphe using one arm of the continuous suture. The second layer of the reconstruction was then performed with the other arm of the suture, approximating the posterior lip of the bladder neck and vesicoprostatic muscle to the posterior urethral edge. Measurements: Continence rates were assessed with a self-administrated, validated questionnaire (Expanded Prostate Cancer Index Composite) at 1, 4, 12, and 24 wk after catheter removal. Continence was defined as the use of ""no absorbent pads."" Cystogram was performed in all patients on postoperative day 4 or 5 before catheter removal. Results and limitations: There was no significant difference between the groups with respect to patient age, body mass index, prostate-specific antigen levels, prostate weight, American Urological Association symptom score, estimated blood loss, operative time, number of nerve-sparing procedures, and days with catheter. In the PR group, the continence rates at 1, 4, 12, and 24 wk postoperatively were 22.7%, 42.7%, 91.8%, and 96.3%, respectively; in the non-PR group, the continence rates were 28.7%, 51.6%, 91.1%, and 97%, respectively. The modified PR technique resulted in significantly higher continence rates at 1 and 4 wk after catheter removal (p = 0.048 and 0.016, respectively), although the continence rates at 12 and 24 wk were not significantly affected (p = 0.908 and p = 0.741, respectively). The median interval to recovery of continence was also statistically significantly shorter in the PR group (median: 4 wk; 95% confidence interval [CI]: 3.39-4.61) when compared to the non-PR group (median: 6 wk; 95% CI: 5.18-6.82; log-rank test, p = 0.037). Finally, the incidence of cystographic leaks was lower in the PR group (0.4% vs 2.1%; p = 0.036). Although the patients` baseline characteristics were similar between the groups, the patients were not preoperatively randomized and unknown confounding factors may have influenced the results. Conclusions: Our modified PR combines the benefits of early recovery of continence reported with the original PR technique with a reinforced watertight closure of the posterior anastomotic wall. Shorter interval to recovery of continence and lower incidence of cystographic leaks were demonstrated with our PR technique when compared to RARP with no reconstruction. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Resumo:
Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.
Resumo:
PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716
Resumo:
Objective. In this study, presence of dentin infection in root canals, obturated with 4 techniques submitted to the bacterial leakage test, was evaluated using histologic methods. Study design. The canals of palatal roots of 160 molars were instrumented and divided into different groups, according to the obturation technique used (lateral condensation, MicroSeal system, Touch `n Heat + Ultrafil, and Tagger`s hybrid technique) and extent of the remaining obturation material (5 mm and 10 mm). Ten additional roots were used as control samples. The roots were sterilized in ethylene oxide and mounted on a device for evaluation of bacterial leakage using the bacteria Enterococcus faecalis for 120 days. After the leakage test, roots were microscopically analyzed for the presence of dentin infection in the root canals and dentinal tubules. Results. A total of 154 specimens were analyzed using both methodologies in the experimental groups; 50 root canals (32.4%) showed bacterial leakage at the end of the experimental period, and 118 (76.6%) showed the presence of bacteria in the root canals using the histologic criteria. The lateral condensation technique allowed lower penetration of bacteria in the root canals and dentinal tubules, followed by Touch `n Heat + Ultrafil, MicroSeal, and Tagger`s hybrid technique, which allowed significantly greater penetration of bacteria. Root canals with 10 mm of remaining obturation material presented similar bacterial penetration as root canals with 5 mm. Conclusions. Even when an adequate seal of the apical foramen was shown by the absence of turbidity in the bacterial leakage test, E. faecalis dentin infection was present in a high percentage of the root canals after 120 days of root filling exposure to the bacteria. Tagger`s hybrid technique presented greater quantity of bacteria in histologic sections than root canals obturated with the other techniques. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 788-794)