584 resultados para soft contact lens
Resumo:
Purpose: To investigate the influence of soft contact lenses on regional variations in corneal thickness and shape while taking account of natural diurnal variations in these corneal parameters. Methods: Twelve young, healthy subjects wore 4 different types of soft contact lenses on 4 different days. The lenses were of two different materials (silicone hydrogel, hydrogel), designs (spherical, toric) and powers (–3.00, –7.00 D). Corneal thickness and topography measurements were taken before and after 8 hours of lens wear and on two days without lens wear, using the Pentacam HR system. Results: The hydrogel toric contact lens caused the greatest level of corneal thickening in the central (20.3 ± 10.0 microns) as well as peripheral cornea (24.1 ± 9.1 microns) (p < 0.001) with an obvious regional swelling of the cornea beneath the stabilizing zones. The anterior corneal surface generally showed slight flattening. All contact lenses resulted in central posterior corneal steepening and this was weakly correlated with central corneal swelling (p = 0.03) and peripheral corneal swelling (p = 0.01). Conclusions: There was an obvious regional corneal swelling apparent after wear of the hydrogel soft toric lenses, due to the location of the thicker stabilization zones of the toric lenses. However with the exception of the hydrogel toric lens, the magnitude of corneal swelling induced by the contact lenses over the 8 hours of wear was less than the natural diurnal thinning of the cornea over this same period.
Resumo:
Thoroughly revised and updated, this popular book provides a comprehensive yet easy to read guide to modern contact lens practice. Beautifully re-designed in a clean, contemporary layout, this second edition presents relevant and up-to-date information in a systematic manner, with a logical flow of subject matter from front to back. This book wonderfully captures the ‘middle ground’ in the contact lens field … somewhere between a dense research-based tome and a basic fitting guide. As such, it is ideally suited for both students and general eye care practitioners who require a practical, accessible and uncluttered account of the contact lens field. Contents Part 1 Introduction Historical perspective. The anterior eye Visual optics Clinical instruments Part 2 Soft contact lenses Soft lens materials Soft lens manufacture Soft lens optics Soft lens measurement Soft lens design and fitting Soft toric lens design and fitting Soft lens care systems Part 3 Rigid contact lenses Rigid lens materials Rigid lens manufacture Rigid lens optics Rigid lens measurement Rigid lens design and fitting Rigid toric lens design and fitting Rigid lens care systems Part 4 Lens replacement modalities Unplanned lens replacement Daily soft lens replacement Planned soft lens replacement Planned rigid lens replacement Part 5 Special lenses and fitting considerations Scleral lenses Tinted lenses Presbyopia Continuous wear Sport Keratoconus High ametropia Paediatric fitting Therapeutic applications Post-refractive Surgery Post-keratoplasty Orthokeratology Diabetes Part 6 Patient examination and management History taking Preliminary examination Patient education Aftercare Complications Digital imaging Compliance Practice management Appendices Index
Resumo:
Purpose: The aim was to determine world-wide patterns of fitting contact lenses for the correction of presbyopia. Methods: Up to 1,000 survey forms were sent to contact lens fitters in each of 38 countries between January and March every year over five consecutive years (2005 to 2009). Practitioners were asked to record data relating to the first 10 contact lens fittings or refittings performed after receiving the survey form. Results: Data were received relating to 16,680 presbyopic (age 45 years or older) and 84,202 pre-presbyopic (15 to 44 years) contact lens wearers. Females are over-represented in presbyopic versus pre-presbyopic groups, possibly reflecting a stronger desire for the cosmetic benefits of contact lenses among older women. The extent to which multifocal and monovision lenses are prescribed for presbyopes varies considerably among nations, ranging from 79 per cent of all soft lenses in Portugal to zero in Singapore. There appears to be significant under-prescribing of contact lenses for the correction of presbyopia, although for those who do receive such corrections, three times more multifocal lenses are fitted compared with monovision fittings. Presbyopic corrections are most frequently prescribed for full-time wear and monthly replacement. Conclusions: Despite apparent improvements in multifocal design and an increase in available multifocal options in recent years, practitioners are still under-prescribing with respect to the provision of appropriate contact lenses for the correction of presbyopia. Training of contact lens practitioners in presbyopic contact lens fitting should be accelerated and clinical and laboratory research in this field should be intensified to enhance the prospects of meeting the needs of presbyopic contact lens wearers more fully.
Resumo:
Contact lenses are a common method for the correction of refractive errors of the eye. While there have been significant advancements in contact lens designs and materials over the past few decades, the lenses still represent a foreign object in the ocular environment and may lead to physiological as well as mechanical effects on the eye. When contact lenses are placed in the eye, the ocular anatomical structures behind and in front of the lenses are directly affected. This thesis presents a series of experiments that investigate the mechanical and physiological effects of the short-term use of contact lenses on anterior and posterior corneal topography, corneal thickness, the eyelids, tarsal conjunctiva and tear film surface quality. The experimental paradigm used in these studies was a repeated measures, cross-over study design where subjects wore various types of contact lenses on different days and the lenses were varied in one or more key parameters (e.g. material or design). Both, old and newer lens materials were investigated, soft and rigid lenses were used, high and low oxygen permeability materials were tested, toric and spherical lens designs were examined, high and low powers and small and large diameter lenses were used in the studies. To establish the natural variability in the ocular measurements used in the studies, each experiment also contained at least one “baseline” day where an identical measurement protocol was followed, with no contact lenses worn. In this way, changes associated with contact lens wear were considered in relation to those changes that occurred naturally during the 8 hour period of the experiment. In the first study, the regional distribution and magnitude of change in corneal thickness and topography was investigated in the anterior and posterior cornea after short-term use of soft contact lenses in 12 young adults using the Pentacam. Four different types of contact lenses (Silicone hydrogel/ Spherical/–3D, Silicone Hydrogel/Spherical/–7D, Silicone Hydrogel/Toric/–3D and HEMA/Toric/–3D) of different materials, designs and powers were worn for 8 hours each, on 4 different days. The natural diurnal changes in corneal thickness and curvature were measured on two separate days before any contact lens wear. Significant diurnal changes in corneal thickness and curvature within the duration of the study were observed and these were taken into consideration for calculating the contact lens induced corneal changes. Corneal thickness changed significantly with lens wear and the greatest corneal swelling was seen with the hydrogel (HEMA) toric lens with a noticeable regional swelling of the cornea beneath the stabilization zones, the thickest regions of the lenses. The anterior corneal surface generally showed a slight flattening with lens wear. All contact lenses resulted in central posterior corneal steepening, which correlated with the relative degree of corneal swelling. The corneal swelling induced by the silicone hydrogel contact lenses was typically less than the natural diurnal thinning of the cornea over this same period (i.e. net thinning). This highlights why it is important to consider the natural diurnal variations in corneal thickness observed from morning to afternoon to accurately interpret contact lens induced corneal swelling. In the second experiment, the relative influence of lenses of different rigidity (polymethyl methacrylate – PMMA, rigid gas permeable – RGP and silicone hydrogel – SiHy) and diameters (9.5, 10.5 and 14.0) on corneal thickness, topography, refractive power and wavefront error were investigated. Four different types of contact lenses (PMMA/9.5, RGP/9.5, RGP/10.5, SiHy/14.0), were worn by 14 young healthy adults for a period of 8 hours on 4 different days. There was a clear association between fluorescein fitting pattern characteristics (i.e. regions of minimum clearance in the fluorescein pattern) and the resulting corneal shape changes. PMMA lenses resulted in significant corneal swelling (more in the centre than periphery) along with anterior corneal steepening and posterior flattening. RGP lenses, on the other hand, caused less corneal swelling (more in the periphery than centre) along with opposite effects on corneal curvature, anterior corneal flattening and posterior steepening. RGP lenses also resulted in a clinically and statistically significant decrease in corneal refractive power (ranging from 0.99 to 0.01 D), large enough to affect vision and require adjustment in the lens power. Wavefront analysis also showed a significant increase in higher order aberrations after PMMA lens wear, which may partly explain previous reports of "spectacle blur" following PMMA lens wear. We further explored corneal curvature, thickness and refractive changes with back surface toric and spherical RGP lenses in a group of 6 subjects with toric corneas. The lenses were worn for 8 hours and measurements were taken before and after lens wear, as in previous experiments. Both lens types caused anterior corneal flattening and a decrease in corneal refractive power but the changes were greater with the spherical lens. The spherical lens also caused a significant decrease in WTR astigmatism (WRT astigmatism defined as major axis within 30 degrees of horizontal). Both the lenses caused slight posterior corneal steepening and corneal swelling, with a greater effect in the periphery compared to the central cornea. Eyelid position, lid-wiper and tarsal conjunctival staining were also measured in Experiment 2 after short-term use of the rigid and SiHy contact lenses. Digital photos of the external eyes were captured for lid position analysis. The lid-wiper region of the marginal conjunctiva was stained using fluorescein and lissamine green dyes and digital photos were graded by an independent masked observer. A grading scale was developed in order to describe the tarsal conjunctival staining. A significant decrease in the palpebral aperture height (blepharoptosis) was found after wearing of PMMA/9.5 and RGP/10.5 lenses. All three rigid contact lenses caused a significant increase in lid-wiper and tarsal staining after 8 hours of lens wear. There was also a significant diurnal increase in tarsal staining, even without contact lens wear. These findings highlight the need for better contact lens edge design to minimise the interactions between the lid and contact lens edge during blinking and more lubricious contact lens surfaces to reduce ocular surface micro-trauma due to friction and for. Tear film surface quality (TFSQ) was measured using a high-speed videokeratoscopy technique in Experiment 2. TFSQ was worse with all the lenses compared to baseline (PMMA/9.5, RGP/9.5, RGP/10.5, and SiHy/14) in the afternoon (after 8 hours) during normal and suppressed blinking conditions. The reduction in TFSQ was similar with all the contact lenses used, irrespective of their material and diameter. An unusual pattern of change in TFSQ in suppressed blinking conditions was also found. The TFSQ with contact lens was found to decrease until a certain time after which it improved to a value even better than the bare eye. This is likely to be due to the tear film drying completely over the surface of the contact lenses. The findings of this study also show that there is still a scope for improvement in contact lens materials in terms of better wettability and hydrophilicity in order to improve TFSQ and patient comfort. These experiments showed that a variety of changes can occur in the anterior eye as a result of the short-term use of a range of commonly used contact lens types. The greatest corneal changes occurred with lenses manufactured from older HEMA and PMMA lens materials, whereas modern SiHy and rigid gas permeable materials caused more subtle changes in corneal shape and thickness. All lenses caused signs of micro-trauma to the eyelid wiper and palpebral conjunctiva, although rigid lenses appeared to cause more significant changes. Tear film surface quality was also significantly reduced with all types of contact lenses. These short-term changes in the anterior eye are potential markers for further long term changes and the relative differences between lens types that we have identified provide an indication of areas of contact lens design and manufacture that warrant further development.
Resumo:
Purpose: Silicone hydrogel contact lenses (CLs) are becoming increasingly popular for daily wear (DW), extended wear (EW) and continuous wear (CW), due to their higher oxygen transmissibility compared to hydrogel CLs. The aim of this study was to investigate the clinical and subjective performance of asmofilcon A (Menicon Co., Ltd), a new surface treated silicone hydrogel CL, during 6-night EW over 6 months (M). Methods: A prospective, randomised, single-masked, monadic study was conducted. N=60 experienced DW soft CL wearers were randomly assigned to wear either asmofilcon A (test: Dk=129, water content (WC)=40%, Nanogloss surface treatment) or senofilcon A (control: Dk=103, WC=38%, PVP internal wetting agent, Vistakon, Johnson & Johnson Vision Care) CLs bilaterally for 6 M on an EW basis. A PHMB-preserved solution (Menicon Co., Ltd) was dispensed for CL care. Evaluations were conducted at CL delivery and after 1 week (W), 4 W, 3 M and 6 M of EW. At each visit, a range of objective and subjective clinical performance measures were assessed. Results: N=50 subjects (83%) successfully completed the study, with the majority of discontinuations due to loss to follow-up (n=3) or moving away/travel (n=5). N=2 subjects experienced adverse events; n=1 unilateral red eye with asmofilcon A and n=1 asymptomatic infiltrate with senofilcon A. There were no significant differences in high or low contrast distance visual acuity (HCDVA or LCDVA) between asmofilcon A and senofilcon A; however, LCDVA decreased significantly over time with both CL types (p<0.05). The two CL types did not vary significantly with respect to any of the objective and subjective measures assessed (p>0.05); CL fitting characteristics and CL surface measurements were very similar and mean bulbar and limbal redness measures were always less than grade 1.0. Superior palpebral conjunctival injection showed a statistically, but not clinically, significant increase over time with both CL types (p<0.05). Corneal staining did not vary significantly between asmofilcon A and senofilcon A (p>0.05), with low median gradings of less than 0.5 observed for all areas assessed. There were no solution-related staining reactions observed with either CL type. The asmofilcon A and senofilcon A CLs were both rated highly with respect to overall comfort, with medians of 14 or 15 hours of comfortable lens wearing time per day reported at each of the study visits (p>0.05). Conclusions: Over 6 months of EW, the asmofilcon A and senofilcon A CLs performed in a similar manner with respect to visual acuity, ocular health and CL performance measures. Some changes over time were observed with both CL types, including reduced LCDVA and increased superior palpebral injection, which warrant further investigation in longer-term EW studies. Asmofilcon A appeared to be equivalent in performance to senofilcon A.
Resumo:
Purpose: The aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses. Method: Fourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day. Results: Anterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p ≤ 0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p ≤ 0.05). Conclusion: The corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.
Resumo:
Purpose The aim was to determine the extent of daily disposable contact lens prescribing worldwide and to characterise the associated demographics and fitting patterns. Methods Up to 1,000 survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for five consecutive years (2007 to 2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Survey data collected since 1996 were also analysed for seven nations to assess daily disposable lens fitting trends since that time. Results Data were collected in relation to 97,289 soft lens fits, of which 23,445 (24.1 per cent) were with daily disposable lenses and 73,170 (75.9 per cent) were with reusable lenses. Daily disposable lens prescribing ranged from 0.6 per cent of all soft lenses in Nepal to 66.2 per cent in Qatar. Compared with reusable lens fittings, daily disposable lens fittings can be characterised as follows: older age (30.0 ± 12.5 versus 29.3 ± 12.3 years for reusable lenses); males are over-represented; a greater proportion of new fits versus refits; 85.9 per cent hydrogel; lower proportion of toric and presbyopia designs and a higher proportion of part-time wear. There has been a continuous increase in daily disposable lens prescribing between 1996 and 2011. The proportion of daily disposable lens fits (as a function of all soft lens fits) is positively related to the gross domestic product at purchasing power parity per capita (r2 = 0.55, F = 46.8, p < 0.0001). Conclusions The greater convenience and other benefits of daily disposable lenses have resulted in this modality capturing significant market share. The contact lens field appears to be heading toward a true single-use-only, disposable lens market.
Resumo:
Purpose To determine the extent of rigid contact lens fitting worldwide and to characterize the associated demographics and fitting patterns. Methods Survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for five consecutive years (2007 to 2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Survey data collected between 1996 and 2011 were also analyzed to assess rigid lens fitting trends in seven nations during this period. Results Data were obtained for 12,230 rigid and 100,670 soft lens fits between 2007 and 2011. Overall, rigid lenses represented 10.8% of all contact lens fits, ranging from 0.2% in Lithuania to 37% in Malaysia. Compared with soft lens fits, rigid lens fits can be characterized as follows: older age (rigid, 37.3 ± 15.0 years; soft, 29.8 ± 12.4 years); fewer spherical and toric fits; more bifocal/multifocal fits; less frequent replacement (rigid, 7%; soft, 85%); and less part-time wear (rigid, 4%; soft, 10%). High-Dk (contact lens oxygen permeability) (36%) and mid-Dk (42%) materials are predominantly used for rigid lens fitting. Orthokeratology represents 11.5% of rigid contact lens fits. There has been a steady decline in rigid lens fitting between 1996 and 2011. Conclusions Rigid contact lens prescribing is in decline but still represents approximately 10% of all contact lenses fitted worldwide. It is likely that rigid lenses will remain as a viable, albeit increasingly specialized, form of vision correction.
Resumo:
Objectives To characterize and discover the determinants of the frequency of wear (FOW) of contact lenses. Methods Survey forms were sent to contact lens fitters in up to 40 countries between January and March every year for 5 consecutive years (2007–2011). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Only data for daily wear lens fits were analyzed. Results Data were collected in relation to 74,510 and 9,014 soft and rigid lens fits, respectively. Overall, FOW was 5.9±1.7 days per week (DPW). When considering the proportion of lenses worn between one to seven DPW, the distribution for rigid lenses is skewed toward full-time wear (7 DPW), whereas the distribution for soft daily disposable lenses is perhaps bimodal, with large and small peaks at seven and two DPW, respectively. There is a significant variation in FOW among nations (P<0.0001), ranging from 6.8±1.0 DPW in Greece to 5.1±2.5 DPW in Kuwait. For soft lenses, FOW increases with decreasing age. Females (6.0±1.6 DPW) wear lenses more frequently than males (5.8±1.7 DPW) (P=0.0002). FOW is greater among those wearing presbyopic corrections (6.1±1.4 DPW) compared with spherical (5.9±1.7 DPW) and toric (5.9±1.6 DPW) designs (P<0.0001). FOW with hydrogel peroxide systems (6.4±1.1 DPW) was greater than that with multipurpose systems (6.2±1.3 DPW) (P<0.0001). Conclusions Numerous demographic and contact lens–related factors impact FOW. There may be a future trend toward a lower FOW associated with the increasing popularity of daily disposable lenses.
Resumo:
We sought to determine the impact of optometric practice setting on contact lens prescribing by analysing annual survey data of lens fits collected between 2009 and 2013 from independent and national group practices throughout the United Kingdom. Compared to national group practices, independent practices fit contact lenses to older patients and more females. Independent practices also undertake a lower proportion of soft lens fits overall (and thus a higher proportion of rigid lens fits), soft toric lens fits and daily disposable lens fits. There is a higher proportion of soft extended wear and multifocal lens fits in independent practices. We conclude that contact lens fitting behaviour is influenced by optometric practice setting.
Resumo:
A new imaging methodology is described to visualise the post lens tear film (PLTF) during contact lens wear. A rotating-Scheimpflug camera in combination with sodium fluorescein allows evaluation of the PLTF for different contact lens modalities, including mini-scleral, rigid gas permeable (RGP) and soft contact lenses. This imaging technique provides an extension of the instrument’s current functionality. The potential advantages and limitations of the technique are discussed.
Resumo:
Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
Purpose To document contact lens prescribing patterns in the United States between 2002 and 2014. Methods A survey of contact lens prescribing trends was conducted each year between 2002 and 2014, inclusive. Randomly selected contact lens practitioners were asked to provide information relating to 10 consecutive contact lens fits between January and March each year. Results Over the 13-year survey period, 1650 survey forms were received from US practitioners representing details of 7702 contact lens fits. The mean (±SD) age of lens wearers was 33.6 (±15.2) years, of whom 65.2% were female. Rigid lens new fits decreased from 13.0% in 2002 to 9.4% in 2014. Across this period, silicone hydrogels have replaced mid water contact lens hydrogels as the soft lens material of choice. Toric lenses represented about 25 to 30% of all soft lens fits. Multifocal soft lenses are generally preferred to monovision. Daily disposable lens fits have recently increased, and in 2014, they represented 27.1% of all soft lens fits. Most lenses are prescribed on 1 to 2 weekly or monthly lens replacement regimen. Extended wear remains a minority lens wearing modality. The vast majority of those wearing reusable lenses use multipurpose lens care solutions. Lenses are mostly worn 7 d/wk. Conclusions This survey has revealed prescribing trends and preferences in the United States over the past 13 years.
Resumo:
Purpose: The aim of this study was to compare a developmental optical coherence tomography (OCT) based contact lens inspection instrument to a widely used geometric inspection instrument (Optimec JCF), to establish the capability of a market focused OCT system. Methods: Measurements of 27 soft spherical contact lenses were made using the Optimec JCF and a new OCT based instrument, the Optimec is830. Twelve of the lenses analysed were specially commissioned from a traditional hydrogel (Contamac GM Advance 49%) and 12 from a silicone hydrogel (Contamac Definitive 65), each set with a range of back optic zone radius (BOZR) and centre thickness (CT) values. Three commercial lenses were also measured; CooperVision MyDay (Stenfilcon A) in −10D, −3D and +6D powers. Two measurements of BOZR, CT and total diameter were made for each lens in temperature controlled saline on both instruments. Results: The results showed that the is830 and JCF measurements were comparable, but that the is830 had a better repeatability coefficient for BOZR (0.065 mm compared to 0.151 mm) and CT (0.008 mm compared to 0.027 mm). Both instruments had similar results for total diameter (0.041 mm compared to 0.044 mm). Conclusions: The OCT based instrument assessed in this study is able to match and improve on the JCF instrument for the measurement of total diameter, back optic zone radius and centre thickness for soft contact lenses in temperature controlled saline.
Resumo:
Purpose: To examine the objective clinical performance of ‘comfort-enhanced’ daily disposable contact lenses over a 16-h day. Methods: Four contact lenses (Hilafilcon B, Etafilcon A Plus, Nelfilcon A and Nelfilcon A Plus) were evaluated in an investigator masked, open label trial at the end of a week’s bilateral wear. Pre-lens noninvasive tear break-up time (PL-NITBUT), tear prism height, bulbar hyperaemia and ocular surface temperature (OST) were measured with the lens in situ at 8, 12 and 16 h of wear. Results: There was no difference between how many hours the lenses types were worn each day (F = 0.90, p = 0.44). The PL-NITBUT decreased with the duration of daily lens wear (F = 32.0, p < 0.001) and was more stable with Nelfilcon A Plus (F = 6.00, p = 0.002) than with the other lenses evaluated. Bulbar blood vessels increased in coverage (F = 11.5, p < 0.001) but not overall redness (F = 0.0, p = 0.99) with the duration of daily lens wear, but there was no difference between the lenses (p > 0.05). The tear prism height decreased with the duration of daily wear (F = 27.0, p < 0.001) and differed between lenses (F = 2.9, p = 0.04). The OST decreased with the duration of lens wear (F = 119.7, p < 0.001) and was reduced by daily disposable lens wear (F = 7.88, p < 0.001), but did not differ between lenses (F = 0.88, p = 0.45). Conclusions: Objective measures of tear film indicated a difference between the lenses evaluated for PLNITBUT and tear prism height, but not for wearing time or bulbar conjunctival hyperaemia. Therefore clinical benefits of daily disposable ‘comfort enhancing’ contact lenses can be measured, but challenges remain in producing contact lenses that do not compromise anterior eye physiology over the whole day. 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.