963 resultados para sinus node


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project covered the 2006-2011 operations of the Northern Node of Barley Breeding Australia (BBA-North). BBANorth collaborated with the Southern and Western nodes and all BBA participants to deliver improved barley varieties to the Australian grains industry. BBA-North focused on the northern region and was the national leader in breeding high yielding, disease resistant barleys with grain quality that enhanced the crop's status as a preferred feed grain. Development of varieties for the malting and brewing industries was also targeted. This project incorporated coordination, breeding, regional evaluation, foliar and soil-borne disease tests, molecular marker screens and grain and malt quality analyses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new 8-node serendipity quadrilateral plate bending element (MQP8) based on the Mindlin-Reissner theory for the analysis of thin and moderately thick plate bending problems using Integrated Force Method is presented in this paper. The performance of this new element (MQP8) is studied for accuracy and convergence by analyzing many standard benchmark plate bending problems. This new element MQP8 performs excellent in both thin and moderately thick plate bending situations. And also this element is free from spurious/zero energy modes and free from shear locking problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the use of sentinel node biopsy (SNB) in the axillary nodal staging in breast cancer. A special interest was in sentinel node (SN) visualization, intraoperative detection of SN metastases, the feasibility of SNB in patients with pure tubular carcinoma (PTC) and in those with ductal carcinoma in situ (DCIS) in core needle biopsy (CNB) and additionally in the detection of axillary recurrences after tumour negative SNB. Patients and methods. 1580 clinically stage T1-T2 node-negative breast cancer patients, who underwent lymphoscintigraphy (LS), SNB and breast surgery between June 2000 - 2004 at the Breast Surgery Unit. The CNB samples were obtained from women, who participated the biennial, population based mammography screening at the Mammography Screening Centre of Helsinki 2001 - 2004.In the follow- up, a cohort of 205 patients who avoided AC due to negative SNB findings were evaluated using ultrasonography one and three years after breast surgery. Results. The visualization rate of axillary SNs was not enhanced by adjusting radioisotope doses according to BMI. The sensitivity of the intraoperative diagnosis of SN metastases of invasive lobular carcinoma (ILC) was higher, 87%, with rapid, intraoperative immunohistochemistry (IHC) group compared to 66% without it. The prevalence of tumour positive SN findings was 27% in the 33 patients with breast tumours diagnosed as PTC. The median histological tumour size was similar in patients with or without axillary metastases. After the histopathological review, six out of 27 patients with true PTC had axillary metastases, with no significant change in the risk factors for axillary metastases. Of the 67 patients with DCIS in the preoperative percutaneous biopsy specimen , 30% had invasion in the surgical specimen. The strongest predictive factor for invasion was the visibility of the lesion in ultrasound. In the three year follow-up, axillary recurrence was found in only two (0.5%) of the total of 383 ultrasound examinations performed during the study, and only one of the 369 examinations revealed cancer. None of the ultrasound examinations were false positive, and no study participant was subjected to unnecessary surgery due to ultrasound monitoring. Conclusions. Adjusting the dose of the radioactive tracer according to patient BMI does not increase the visualization rate of SNs. The intraoperative diagnosis of SN metastases is enhanced by rapid IHC particularly in patients with ILC. SNB seems to be a feasible method for axillary staging of pure tubular carcinoma in patients with a low prevalence of axillary metatastases. SNB also appears to be a sensible method in patients undergoing mastectomy due to DCIS in CNB. It also seems useful in patients with lesions visible in breast US. During follow-up, routine monitoring of the ipsilateral axilla using US is not worthwhile among breast cancer patients who avoided AC due to negative SN findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is the most common tachyarrhythmia and is associated with substantial morbidity, increased mortality and cost. The treatment modalities of AF have increased, but results are still far from optimal. More individualized therapy may be beneficial. Aiming for this calls improved diagnostics. Aim of this study was to find non-invasive parameters obtained during sinus rhythm reflecting electrophysiological patterns related to propensity to AF and particularly to AF occurring without any associated heart disease, lone AF. Overall 240 subjects were enrolled, 136 patients with paroxysmal lone AF and 104 controls (mean age 45 years, 75% males). Signal measurements were performed by non-invasive magnetocardiography (MCG) and by invasive electroanatomic mapping (EAM). High-pass filtering techniques and a new method based on a surface gradient technique were adapted to analyze atrial MCG signal. The EAM was used to elucidate atrial activation in patients and as a reference for MCG. The results showed that MCG mapping is an accurate method to detect atrial electrophysiologic properties. In lone paroxysmal AF, duration of the atrial depolarization complex was marginally prolonged. The difference was more obvious in women and was also related to interatrial conduction patterns. In the focal type of AF (75%), the root mean square (RMS) amplitudes of the atrial signal were normal, but in AF without demonstrable triggers the late atrial RMS amplitudes were reduced. In addition, the atrial characteristics tended to remain similar even when examined several years after the first AF episodes. The intra-atrial recordings confirmed the occurrence of three distinct sites of electrical connection from right to left atrium (LA): the Bachmann bundle (BB), the margin of the fossa ovalis (FO), and the coronary sinus ostial area (CS). The propagation of atrial signal could also be evaluated non-invasively. Three MCG atrial wave types were identified, each of which represented a distinct interatrial activation pattern. In conclusion, in paroxysmal lone AF, active focal triggers are common, atrial depolarization is slightly prolonged, but with a normal amplitude, and the arrhythmia does not necessarily lead to electrical or mechanical dysfunction of the atria. In women the prolongation of atrial depolarization is more obvious. This may be related to gender differences in presentation of AF. A significant minority of patients with lone AF lack frequent focal triggers, and in them, the late atrial signal amplitude is reduced, possibly signifying a wider degenerative process in the LA. In lone AF, natural impulse propagation to LA during sinus rhythm goes through one or more of the principal pathways described. The BB is the most common route, but in one-third, the earliest LA activation occurs outside the BB. Susceptibility to paroxysmal lone AF is associated with propagation of the atrial signal via the margin of the FO or via multiple pathways. When conduction occurs via the BB, it is related with prolonged atrial activation. Thus, altered and alternative conduction pathways may contribute to pathogenesis of lone AF. There is growing evidence of variability in genesis of AF also within lone paroxysmal AF. Present study suggests that this variation may be reflected in cardiac signal pattern. Recognizing the distinct signal profiles may assist in understanding the pathogenesis of AF and identifying subgroups for patient-tailored therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today finite element method is a well established tool in engineering analysis and design. Though there axe many two and three dimensional finite elements available, it is rare that a single element performs satisfactorily in majority of practical problems. The present work deals with the development of 4-node quadrilateral element using extended Lagrange interpolation functions. The classical univariate Lagrange interpolation is well developed for 1-D and is used for obtaining shape functions. We propose a new approach to extend the Lagrange interpolation to several variables. When variables axe more than one the method also gives the set of feasible bubble functions. We use the two to generate shape function for the 4-node arbitrary quadrilateral. It will require the incorporation of the condition of rigid body motion, constant strain and Navier equation by imposing necessary constraints. The procedure obviates the need for isoparametric transformation since interpolation functions are generated for arbitrary quadrilateral shapes. While generating the element stiffness matrix, integration can be carried out to the accuracy desired by dividing the quadrilateral into triangles. To validate the performance of the element which we call EXLQUAD4, we conduct several pathological tests available in the literature. EXLQUAD4 predicts both stresses and displacements accurately at every point in the element in all the constant stress fields. In tests involving higher order stress fields the element is assured to converge in the limit of discretisation. A method thus becomes available to generate shape functions directly for arbitrary quadrilateral. The method is applicable also for hexahedra. The approach should find use for development of finite elements for use with other field equations also.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study a sensor node with an energy harvesting source. In any slot,the sensor node is in one of two modes: Wake or Sleep. The generated energy is stored in a buffer. The sensor node senses a random field and generates a packet when it is awake. These packets are stored in a queue and transmitted in the wake mode using the energy available in the energy buffer. We obtain energy management policies which minimize a linear combination of the mean queue length and the mean data loss rate. Then, we obtain two easily implementable suboptimal policies and compare their performance to that of the optimal policy. Next, we extend the Throughput Optimal policy developed in our previous work to sensors with two modes. Via this policy, we can increase the through put substantially and stabilize the data queue by allowing the node to sleep in some slots and to drop some generated packets. This policy requires minimal statistical knowledge of the system. We also modify this policy to decrease the switching costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Integrated Force Method (IFM) is a novel matrix formulation developed for analyzing the civil, mechanical and aerospace engineering structures. In this method all independent/internal forces are treated as unknown variables which are calculated by simultaneously imposing equations of equilibrium and compatibility conditions. This paper presents a new 12-node serendipity quadrilateral plate bending element MQP12 for the analysis of thin and thick plate problems using IFM. The Mindlin-Reissner plate theory has been employed in the formulation which accounts the effect of shear deformation. The performance of this new element with respect to accuracy and convergence is studied by analyzing many standard benchmark plate bending problems. The results of the new element MQP12 are compared with those of displacement-based 12-node plate bending elements available in the literature. The results are also compared with exact solutions. The new element MQP12 is free from shear locking and performs excellent for both thin and moderately thick plate bending situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some conventional finite elements suffer from drawbacks, such as shear locking, membrane locking, etc. To overcome them researchers have developed various techniques, termed as tricks by some and variational crimes by others. Many attempts have been made, but satisfactory explanations for why some of these techniques work have not been obtained, especially in the case of solid elements. This paper attempts a simple non-conforming solid element using assumed displacement fields which satisfy the Navier equation exactly. Its behaviour under simple loadings like bending, torsion and tension is examined and comparisons are made with existing elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many wireless applications, it is highly desirable to have a fast mechanism to resolve or select the packet from the user with the highest priority. Furthermore, individual priorities are often known only locally at the users. In this paper we introduce an extremely fast, local-information-based multiple access algorithm that selects the best node in 1.8 to 2.1 slots,which is much lower than the 2.43 slot average achieved by the best algorithm known to date. The algorithm, which we call Variable Power Multiple Access Selection (VP-MAS), uses the local channel state information from the accessing nodes to the receiver, and maps the priorities into the receive power.It is inherently distributed and scales well with the number of users. We show that mapping onto a discrete set of receive power levels is optimal, and provide a complete characterization for it. The power levels are chosen to exploit packet capture that inherently occurs in a wireless physical layer. The VP-MAS algorithm adjusts the expected number of users that contend in each step and their respective transmission powers, depending on whether previous transmission attempts resulted in capture,idle channel, or collision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Closed form solutions for equilibrium and flexibility matrices of the Mindlin-Reissner theory based eight-node rectangular plate bending element (MRP8) using integrated Force Method (IFM) are presented in this paper. Though these closed form solutions of equilibrium and flexibility matrices are applicable to plate bending problems with square/rectangular boundaries, they reduce the computational time significantly and give more exact solutions. Presented closed form solutions are validated by solving large number of standard square/rectangular plate bending benchmark problems for deflections and moments and the results are compared with those of similar displacement-based eight-node quadrilateral plate bending elements available in the literature. The results are also compared with the exact solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new nine-node Lagrangian quadrilateral plate bending element (MQP9) using the Integrated Force Method (IFM) for the analysis of thin and moderately thick plate bending problems. Three degrees of freedom: transverse displacement w and two rotations theta(x) and theta(y) are considered at each node of the element. The Mindlin-Reissner theory has been employed in the formulation which accounts the effect of shear deformation. Many standard plate bending benchmark problems have been analyzed using the new element MQP9 for various grid sizes via Integrated Force Method to estimate defections and bending moments. These results of the new element MQP9 are compared with those of similar displacement-based plate bending elements available in the literature. The results are also compared with exact solutions. It is observed that the presented new element MQP9 is free from shear locking and produced, in general, excellent results in all plate bending benchmark problems considered.