996 resultados para short-wave therapy
Resumo:
The constant-density Charney model describes the simplest unstable basic state with a planetary-vorticity gradient, which is uniform and positive, and baroclinicity that is manifest as a negative contribution to the potential-vorticity (PV) gradient at the ground and positive vertical wind shear. Together, these ingredients satisfy the necessary conditions for baroclinic instability. In Part I it was shown how baroclinic growth on a general zonal basic state can be viewed as the interaction of pairs of ‘counter-propagating Rossby waves’ (CRWs) that can be constructed from a growing normal mode and its decaying complex conjugate. In this paper the normal-mode solutions for the Charney model are studied from the CRW perspective.
Clear parallels can be drawn between the most unstable modes of the Charney model and the Eady model, in which the CRWs can be derived independently of the normal modes. However, the dispersion curves for the two models are very different; the Eady model has a short-wave cut-off, while the Charney model is unstable at short wavelengths. Beyond its maximum growth rate the Charney model has a neutral point at finite wavelength (r=1). Thereafter follows a succession of unstable branches, each with weaker growth than the last, separated by neutral points at integer r—the so-called ‘Green branches’. A separate branch of westward-propagating neutral modes also originates from each neutral point. By approximating the lower CRW as a Rossby edge wave and the upper CRW structure as a single PV peak with a spread proportional to the Rossby scale height, the main features of the ‘Charney branch’ (0
Resumo:
We report on the results of a laboratory investigation using a rotating two-layer annulus experiment, which exhibits both large-scale vortical modes and short-scale divergent modes. A sophisticated visualization method allows us to observe the flow at very high spatial and temporal resolution. The balanced long-wavelength modes appear only when the Froude number is supercritical (i.e. $F\,{>}\,F_\mathrm{critical}\,{\equiv}\, \upi^2/2$), and are therefore consistent with generation by a baroclinic instability. The unbalanced short-wavelength modes appear locally in every single baroclinically unstable flow, providing perhaps the first direct experimental evidence that all evolving vortical flows will tend to emit freely propagating inertia–gravity waves. The short-wavelength modes also appear in certain baroclinically stable flows. We infer the generation mechanisms of the short-scale waves, both for the baro-clinically unstable case in which they co-exist with a large-scale wave, and for the baroclinically stable case in which they exist alone. The two possible mechanisms considered are spontaneous adjustment of the large-scale flow, and Kelvin–Helmholtz shear instability. Short modes in the baroclinically stable regime are generated only when the Richardson number is subcritical (i.e. $\hbox{\it Ri}\,{<}\,\hbox{\it Ri}_\mathrm{critical}\,{\equiv}\, 1$), and are therefore consistent with generation by a Kelvin–Helmholtz instability. We calculate five indicators of short-wave generation in the baroclinically unstable regime, using data from a quasi-geostrophic numerical model of the annulus. There is excellent agreement between the spatial locations of short-wave emission observed in the laboratory, and regions in which the model Lighthill/Ford inertia–gravity wave source term is large. We infer that the short waves in the baroclinically unstable fluid are freely propagating inertia–gravity waves generated by spontaneous adjustment of the large-scale flow.
Resumo:
Objective-To evaluate the effects of extracorporeal shock wave therapy (ESWT) on affected ligaments in the hind limbs of horses with experimentally induced suspensory ligament desmitis by use of ultrasonographic, ultrastructural, and immunocytochemical techniques.Animals-10 horses.Procedure-Suspensory ligament desmitis was induced in both hind limbs of each horse by use of 2 collagenase injections (administered 2 weeks apart) in each suspensory ligament. Two weeks after the second injection, the right hind limb of each horse was treated with ESWT (3 treatments at 3-week intervals)- the left hind limb was not treated (control limb). Periodically during the study, the healing process was monitored ultrasonographically and the proportions of ligaments affected with lesions were assessed. Four weeks after the last ESWT treatment, biopsy specimens were collected from all ligaments for ultrastructural evaluation and immunocytochemical analysis of transforming growth factor beta-1.Results-The difference in the proportion of the lesion-affected ligament between ESWT-treated and control limbs was significant (P < 0.05) from 3 weeks after the second ESWT treatment to the end of the study. Compared with control ligaments, ESWT-treated ligaments had more small, newly formed collagen fibrils and greater expression of transforming growth factor beta-1 4 weeks after the last ESWT treatment was administered.Conclusions and Clinical Relevance-Results have indicated that ESWT appears to facilitate the healing process in horses with experimentally induced hind limb suspensory ligament desmitis.
Resumo:
We establish a Green-Nagdhi model equation for capillary-gravity waves in (2+1) dimensions. Through the derivation of an asymptotic equation governing short-wave dynamics, we show that this system possesses (1 + 1) traveling-wave solutions for almost all the values of the Bond number θ (the special case θ=1/3 is not studied). These waves become singular when their amplitude is larger than a threshold value, related to the velocity of the wave. The limit angle at the crest is then calculated. The stability of a wave train is also studied via a Benjamin-Feir modulational analysis. ©2005 The American Physical Society.
Resumo:
PURPOSE: To evaluate the renal function in healthy dogs submitted to nonselective and preferential COX-2 nonsteroidal anti-inflammatory drug (NSAID) therapy. METHODS: Twenty four healthy dogs were distributed into four groups (G) (n=6): ketoprofenG - treated with ketoprofen; nimesulideG - treated with nimesulid; meloxicanG - treated with meloxican; and etodolacG - treated with etodolaco. All the dogs received the NSAIDs for 10 days by oral route. Physical examination and renal function (urinalysis, urinary sodium and gamma-glutamyl transpeptidase (GGT), serum urea, creatinine, potassium and sodium, and endogenous creatinine clearance) were evaluated before, after five and ten days (T0, T5 and T10) of the treatment in all groups. RESULTS: Changes were observed in urinalysis, with a significant increase in renal cells in the urine at T5 and T10 in nimesulideG. Significant reduction in urinary sodium in nimesulideG at T5 was observed. The clearance values were lower in ketoprofenG at T10. CONCLUSIONS: Meloxicam and etodolac were the drugs that have proven to be safer for short-term therapy in healthy dogs in relation to renal function. NSAIDs ketoprofen and nimesulide should be used judiciously in dogs with renal dysfunction, since there are promoted changes in renal function.
Resumo:
Dentro del equipamiento que existen en los hospitales, se realizan muy diversas actuaciones para el correcto funcionamiento de los equipos que se destinan, tanto a medir sobre el paciente o para tratamiento sobre estos mismos, el abanico de equipos que existen es muy grande, sin contar con los que directamente se instalan o, más correctamente, se implantan en el paciente. Los hospitales tienen establecidas pautas de mantenimiento tanto correctivo como preventivo, también de verificación relativa a seguridad y, en algunos casos, acciones que van destinadas a comprobar las magnitudes en los equipos. Esto último no es lo normal, de hecho, en muchos casos, la mayoría, se desconoce cómo poder comprobar que las magnitudes de un equipo se pueden trazar a un patrón de medida nacional. La investigación se ha desarrollado para determinar, siendo algo que esta patente hasta en la normalización ISO, que no existen para muchos equipos principios establecidos para garantizar la trazabilidad metrológica da las magnitudes físicas en las que trabaja durante su vida útil. Debido a la amplitud de este campo, el desarrollo de investigación se ha llevado en un formato piramidal, desde las necesidades para poder llegar a un estudio concreto de equipos concretos (Termómetros Clínicos, Tensiómetros, Ultrasonidos y Onda Corta). Para llegar a estos se ha realizado un estudio de cómo se encuentra la trazabilidad metrológica en todo el espectro, desde la gestión hasta llegar a casos particulares. Estudiando la gran cantidad de documentación existente y llegando a determinar el campo de trabajo en la metrología hospitalaria, clasificando los equipos y determinando como se encuentran definidos los métodos que llevan a realidad la trazabilidad metrológica, en la normalización. Un grupo no muy trabajado de los equipos electromédicos son los que se encuentran dentro de los tratamientos de Rehabilitación de traumatología, siendo equipos de uso muy habitual en los centros de salud para las lesiones musculares y óseas. A este asunto se ha dedicado un esfuerzo extra, con un reporte histórico de su origen y en qué punto se encuentran ahora. Se han estudiado dentro de estos equipos los de tratamiento de ultrasonidos, de diatermia y onda corta, que son los más representativos de los equipos destinados a electro terapia, pero hay que tener en cuenta que hay campos que se han mencionado globalmente de la rehabilitación, como son la terapia o la biomecánica, de forma similar a otras tecnologías sanitarias de otras especialidades (radiología o análisis clínico). Hay, también, dentro de la terapia, todos esos tratamientos propios de gimnasio, como son poleas, pesas, mesas de masajes, balones, etc… Que su metrología es sencilla, son equipos que existen medios de comprobación de las magnitudes que utilizan por la existencia en otras actividades de la industria (balanzas, pesas, etc). La investigación realizada ha pretendido evaluar todo el global y llegar a casos concretos para determinar cómo está la situación. Llegando a desarrollar una clasificación de equipos y de normas, que permiten vislumbrar las necesidades metrológicas y permitiría establecer una Gestión de la Trazabilidad Metrológica, concluyendo en el estudio para los equipos que se han mencionado. ABSTRACT Within the equipment that exist in the hospitals, there are very diverse performances for the correct operation of the equipment that is intended both to measure on the patient or for treatment on these same, the range of equipment available is very large, without which directly are installed or, more correctly, are implanted in the patient. The hospitals have established patterns of maintenance both corrective and preventive, also of verification of security and, in some cases, actions which are intended to check the magnitudes in the equipment. This last is not normal, in fact, in many cases, the majority, it is not known as to be able to check that the magnitudes of a computer can be traced to a pattern of national measure. The research has been developed to determine, is something that this patent up to the International Organization for Standardization (ISO), that do not exist for many teams established principles to ensure the metrological traceability gives the physical quantities in which they work during its useful life. Due to the breadth of this field, the development of research has been conducted in a pyramid format, from the needs to be able to reach a specific study of specific equipment (Clinical Thermometers, Tensiometers, Ultrasound, and Short Wave). To reach theme, has been carried out a study of how is the metrological traceability across the entire spectrum, from the management to individuals cases. Considering the large amount of existing documentation and arriving to determine the labor camp in the metrology hospital, sorting equipment and determining how are defined the methods that lead to reality the metrological traceability, in the standardization. A group not too worked for medical electrical equipment are found within the rehabilitation treatment of traumatology, being equipment of very common use in the health centers for muscle injuries and bone. In this matter has been dedicated an extra effort, with a report history of its origin and where they are now. We have studied within these teams about the treatment of ultrasound, diathermy, short wave, which are the most representative of the equipment that is destined to electro therapy, but it must be borne in mind that there are fields that have been mentioned globally of rehabilitation, as are the therapy or the biomechanics, similar to other health technologies from other specialties (radiology or clinical analysis). There is, also, within the therapy, all these treatments own gym, such as pulleys, weights, tables of massages, balls, etc… that its metrology is simple, are computers that there are means of verification of the magnitudes that used by the existence in other activities of the industry (scales, weights, etc). The research carried out has tried to assess the entire global and reach specific cases to determine the situation as it is. Arriving in the development of a classification of equipment and standards, which give us a glimpse of the metrological needs and establish a Management of the Metrological Traceability, concluding in the study for computers that have been mentioned.
Resumo:
Background: While one in ten Australians suffer from chronic low back pain this condition remains extremely difficult to treat. Many contemporary treatments are of unknown value. One potentially useful therapy is the use of motor control exercise. This therapy has a biologically plausible effect, is readily available in primary care and it is of modest cost. However, to date, the efficacy of motor control exercise has not been established. Methods: This paper describes the protocol for a clinical trial comparing the effects of motor control exercise versus placebo in the treatment of chronic non-specific low back pain. One hundred and fifty-four participants will be randomly allocated to receive an 8-week program of motor control exercise or placebo (detuned short wave and detuned ultrasound). Measures of outcomes will be obtained at follow-up appointments at 2, 6 and 12 months after randomisation. The primary outcomes are: pain, global perceived effect and patient-generated measure of disability at 2 months and recurrence at 12 months. Discussion: This trial will be the first placebo-controlled trial of motor control exercise. The results will inform best practice for treating chronic low back pain and prevent its occurrence.
Resumo:
This paper presents new laboratory data on the generation of long waves by the shoaling and breaking of transient-focused short-wave groups. Direct offshore radiation of long waves from the breakpoint is shown experimentally for the first time. High spatial resolution enables identification of the relationship between the spatial gradients of the short-wave envelope and the long-wave surface. This relationship is consistent with radiation stress theory even well inside the surf zone and appears as a result of the strong nonlinear forcing associated with the transient group. In shallow water, the change in depth across the group leads to asymmetry in the forcing which generates significant dynamic setup in front of the group during shoaling. Strong amplification of the incident dynamic setup occurs after short-wave breaking. The data show the radiation of a transient long wave dominated by a pulse of positive elevation, preceded and followed by weaker trailing waves with negative elevation. The instantaneous cross-shore structure of the long wave shows the mechanics of the reflection process and the formation of a transient node in the inner surf zone. The wave run-up and relative amplitude of the radiated and incident long waves suggests significant modification of the incident bound wave in the inner surf zone and, the dominance of long waves generated by the breaking process. It is proposed that these conditions occur when the primary short waves and bound wave are not shallow water waves at the breakpoint. A simple criterion is given to determine these conditions, which generally occur for the important case of storm waves.
Resumo:
We present a review of the latest developments in one-dimensional (1D) optical wave turbulence (OWT). Based on an original experimental setup that allows for the implementation of 1D OWT, we are able to show that an inverse cascade occurs through the spontaneous evolution of the nonlinear field up to the point when modulational instability leads to soliton formation. After solitons are formed, further interaction of the solitons among themselves and with incoherent waves leads to a final condensate state dominated by a single strong soliton. Motivated by the observations, we develop a theoretical description, showing that the inverse cascade develops through six-wave interaction, and that this is the basic mechanism of nonlinear wave coupling for 1D OWT. We describe theory, numerics and experimental observations while trying to incorporate all the different aspects into a consistent context. The experimental system is described by two coupled nonlinear equations, which we explore within two wave limits allowing for the expression of the evolution of the complex amplitude in a single dynamical equation. The long-wave limit corresponds to waves with wave numbers smaller than the electrical coherence length of the liquid crystal, and the opposite limit, when wave numbers are larger. We show that both of these systems are of a dual cascade type, analogous to two-dimensional (2D) turbulence, which can be described by wave turbulence (WT) theory, and conclude that the cascades are induced by a six-wave resonant interaction process. WT theory predicts several stationary solutions (non-equilibrium and thermodynamic) to both the long- and short-wave systems, and we investigate the necessary conditions required for their realization. Interestingly, the long-wave system is close to the integrable 1D nonlinear Schrödinger equation (NLSE) (which contains exact nonlinear soliton solutions), and as a result during the inverse cascade, nonlinearity of the system at low wave numbers becomes strong. Subsequently, due to the focusing nature of the nonlinearity, this leads to modulational instability (MI) of the condensate and the formation of solitons. Finally, with the aid of the probability density function (PDF) description of WT theory, we explain the coexistence and mutual interactions between solitons and the weakly nonlinear random wave background in the form of a wave turbulence life cycle (WTLC).
Resumo:
Background: Aspirin, dipyridamole and clopidogrel are effective in secondary vascular prevention. Combination therapy with three antiplatelet agents might maximise the benefit of antiplatelet treatment in the secondary prevention of ischaemic stroke. Methodology/Principal Findings: A randomised, parallel group, observer-blinded phase II trial compared the combination of aspirin, clopidogrel and dipyridamole with aspirin alone. Adult patients with ischaemic stroke or transient ischaemic attack (TIA) within 5 years were included. The primary outcome was tolerability to treatment assessed as the number of patients completing randomised treatment. Recruitment was halted prematurely after publication of the ESPRIT trial (which confirmed that combined aspirin and dipyridamole is more effective than aspirin alone). 17 patients were enrolled: male 12 (71%), mean age 62 (SD 13) years, lacunar stroke syndrome 12 (71%), median stroke/TIA onset to randomisation 8 months. Treatment was discontinued in 4 of 9 (44%) patients receiving triple therapy vs. none of 8 taking aspirin (p = 0.08). One recurrent stroke occurred in a patient in the triple group who was noncompliant of all antiplatelet medications. The number of patients with adverse events and bleeding complications, and their severity, were significantly greater in the triple therapy group (p,0.01). Conclusions/Significance: Long term triple antiplatelet therapy was asociated with a significant increase in adverse events and bleeding rates, and their severity, and a trend to increased discontinuations. However, the patients had a low risk of recurrence and future trials should focus on short term therapy in high risk patients characterised by a very recent event or failure of dual antiplatelet therapy.
Resumo:
A global framework for linear stability analyses of traffic models, based on the dispersion relation root locus method, is presented and is applied taking the example of a broad class of car-following (CF) models. This approach is able to analyse all aspects of the dynamics: long waves and short wave behaviours, phase velocities and stability features. The methodology is applied to investigate the potential benefits of connected vehicles, i.e. V2V communication enabling a vehicle to send and receive information to and from surrounding vehicles. We choose to focus on the design of the coefficients of cooperation which weights the information from downstream vehicles. The coefficients tuning is performed and different ways of implementing an efficient cooperative strategy are discussed. Hence, this paper brings design methods in order to obtain robust stability of traffic models, with application on cooperative CF models
Resumo:
Parent-centred interventions for childhood obesity aim to improve parents' skills and confidence in managing children's dietary and activity patterns, and in promoting a healthy lifestyle in their family. However, few studies assess changes in parenting over the course of treatment. This study describes the evaluation of a lifestyle-specific parenting program (Group Lifestyle Triple P) on multiple child and parent outcomes. One-hundred-and-one families with overweight and obese 4- to 11-year-old children participated in an intervention or waitlist control condition. The 12-week intervention was associated with significant reductions in child BMI z score and weight-related problem behaviour. At the end of the intervention, parents reported increased confidence in managing children's weight-related behaviour, and less frequent use of inconsistent or coercive parenting practices. All short-term intervention effects were maintained at one-year follow-up assessment, with additional improvements in child body size. The results support the efficacy of Group Lifestyle Triple P and suggest that parenting influences treatment outcomes. Further research is needed to evaluate the long-term effectiveness of the intervention and to elucidate the mechanisms of change. © 2010 Elsevier Ltd.
Resumo:
Recent decreases in costs, and improvements in performance, of silicon array detectors open a range of potential applications of relevance to plant physiologists, associated with spectral analysis in the visible and short-wave near infra-red (far-red) spectrum. The performance characteristics of three commercially available ‘miniature’ spectrometers based on silicon array detectors operating in the 650–1050-nm spectral region (MMS1 from Zeiss, S2000 from Ocean Optics, and FICS from Oriel, operated with a Larry detector) were compared with respect to the application of non-invasive prediction of sugar content of fruit using near infra-red spectroscopy (NIRS). The FICS–Larry gave the best wavelength resolution; however, the narrow slit and small pixel size of the charge-coupled device detector resulted in a very low sensitivity, and this instrumentation was not considered further. Wavelength resolution was poor with the MMS1 relative to the S2000 (e.g. full width at half maximum of the 912 nm Hg peak, 13 and 2 nm for the MMS1 and S2000, respectively), but the large pixel height of the array used in the MMS1 gave it sensitivity comparable to the S2000. The signal-to-signal standard error ratio of spectra was greater by an order of magnitude with the MMS1, relative to the S2000, at both near saturation and low light levels. Calibrations were developed using reflectance spectra of filter paper soaked in range of concentrations (0–20% w/v) of sucrose, using a modified partial least squares procedure. Calibrations developed with the MMS1 were superior to those developed using the S2000 (e.g. coefficient of correlation of 0.90 and 0.62, and standard error of cross-validation of 1.9 and 5.4%, respectively), indicating the importance of high signal to noise ratio over wavelength resolution to calibration accuracy. The design of a bench top assembly using the MMS1 for the non-invasive assessment of mesocarp sugar content of (intact) melon fruit is reported in terms of light source and angle between detector and light source, and optimisation of math treatment (derivative condition and smoothing function).