982 resultados para short implants


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the biomechanical fixation, bone-to-implant contact (BIC), and bone morphology of screw-type root-form implants with healing chambers with as-machined or dual acid-etched (DAE) surfaces in a canine model. Materials and Methods: The animal model included the placement of machined (n = 24) and DAE (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Following euthanasia, half of the specimens were subjected to biomechanical testing (torque to interface failure) and the other half were processed for histomorphologic and histomorphometric (%BIC) assessments. Statistical analyses were performed by one-way analysis of variance at the 95% confidence level and the Tukey post hoc test for multiple comparisons. Results: At 4 weeks, the DAE surface presented significantly higher mean values for torque to interface failure overall. A significant increase in %BIC values occurred for both groups over time. For both groups, bone formation through the classic appositional healing pathway was observed in regions where intimate contact between the implant and the osteotomy walls occurred immediately after implantation. Where contact-free spaces existed after implantation (healing chambers), an intramembranous-like healing mode with newly formed woven bone prevailed. Conclusions: In the present short-term evaluation, no differences were observed in BIC between groups; however, an increase in biomechanical fixation was seen from 2 to 4 weeks with the DAE surface. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:75-82

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Poly(epsilon-caprolactone) (PCL) is a biodegradable and biocompatible polymer that presents a very low degradation rate, making it suitable for the development of long-term drug delivery systems. The objective of this pilot study is to evaluate the feasibility and characteristics of PCL devices in the prolonged and controlled intravitreous release of dexamethasone. METHODS: The in vitro release of dexamethasone was investigated and the implant degradation was monitored by the percent of mass loss and by changes in the surface morphology. Differential scanning calorimetry was used to evaluate stability and interaction of the implant and the drug. The short-term tolerance of the implants was studied after intravitreous implantation in rabbit eye. Results: PCL implant allows for a controlled and prolonged delivery of dexamethasone since it releases 25% of the drug in 21 weeks. Its low degradation rate was confirmed by the mass loss and scanning electron microscopy studies. Preliminary observations show that PCL intravitreous implants are very well tolerated in the rabbit eye. CONCLUSION: This study demonstrates the PCL drug delivery systems allowed to a prolonged release of dexamethasone in vitro. The implants demonstrated a strikingly good intraocular short-term tolerance in rabbits eyes. The in vitro and preliminary in vivo studies tend to show that PCL implants could be of interest when long-term sustained intraocular delivery of corticosteroids is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cranial bone reconstructions are necessary for correcting large skull bone defects due to trauma, tumors, infections and craniotomies. Traditional synthetic implant materials include solid or mesh titanium, various plastics and ceramics. Recently, biostable glass-fiber reinforced composites (FRC), which are based on bifunctional methacrylate resin, were introduced as novel implant solution. FRCs were originally developed and clinically used in dental applications. As a result of further in vitro and in vivo testing, these composites were also approved for clinical use in cranial surgery. To date, reconstructions of large bone defects were performed in 35 patients. This thesis is dedicated to the development of a novel FRC-based implant for cranial reconstructions. The proposed multi-component implant consists of three main parts: (i) porous FRC structure; (ii) bioactive glass granules embedded between FRC layers and (iii) a silver-polysaccharide nanocomposite coating. The porosity of the FRC structure should allow bone ingrowth. Bioactive glass as an osteopromotive material is expected to stimulate the formation of new bone. The polysaccharide coating is expected to prevent bacterial colonization of the implant. The FRC implants developed in this study are based on the porous network of randomly-oriented E-glass fibers bound together by non-resorbable photopolymerizable methacrylate resin. These structures had a total porosity of 10–70 volume %, of which > 70% were open pores. The pore sizes > 100 μm were in the biologically-relevant range (50-400 μm), which is essential for vascularization and bone ingrowth. Bone ingrowth into these structures was simulated by imbedding of porous FRC specimens in gypsum. Results of push-out tests indicated the increase in the shear strength and fracture toughness of the interface with the increase in the total porosity of FRC specimens. The osteopromotive effect of bioactive glass is based on its dissolution in the physiological environment. Here, calcium and phosphate ions, released from the glass, precipitated on the glass surface and its proximity (the FRC) and formed bone-like apatite. The biomineralization of the FRC structure, due to the bioactive glass reactions, was studied in Simulated Body Fluid (SBF) in static and dynamic conditions. An antimicrobial, non-cytotoxic polysaccharide coating, containing silver nanoparticles, was obtained through strong electrostatic interactions with the surface of FRC. In in vitro conditions the lactose-modified chitosan (chitlac) coating showed no signs of degradation within seven days of exposure to lysozyme or one day to hydrogen peroxide (H2O2). The antimicrobial efficacy of the coating was tested against Staphylococcus aureus and Pseudomonas aeruginosa. The contact-active coating had an excellent short time antimicrobial effect. The coating neither affected the initial adhesion of microorganisms to the implant surface nor the biofilm formation after 24 h and 72 h of incubation. Silver ions released to the aqueous environment led to a reduction of bacterial growth in the culture medium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Problématique : Les connaissances théoriques et pratiques au sujet de la mise en charge immédiate d’implants non jumelés chez les édentés sont limitées. Objectifs : Cette étude avait pour but de : (1) déterminer le taux de survie implantaire de 2 implants non jumelés supportant une prothèse totale mandibulaire suite à une mise en charge immédiate, (2) évaluer les changements des niveaux osseux et de stabilité implantaire survenus sur ces 2 implants durant une période de 4 mois et les comparer à un implant témoin, et (3) décrire les complications cliniques associées à ce mode de mise en charge. Méthodologie : Chez 18 individus édentés (âge moyen de 62±7 ans), cette étude de phase I avec un design pré/post a évalué les résultats cliniques suivant la mise en charge immédiate (<48 heures) de 2 implants non jumelés par une prothèse totale mandibulaire. À l’aide de radiographies périapicales, de sondages osseux et d’analyses de la fréquence en résonnance, les niveaux osseux péri-implantaires (en mm) et les niveaux de stabilité implantairte (en ISQ) de ces 2 implants insérés dans la région parasymphysaire ont été évalués à la chirurgie (T0) et au suivi de 4 mois (T1). Un implant non submergé et sans mise en charge inséré dans la région de la symphyse mandibulaire a été utilisé comme témoin. Les données ont été analysées avec des modèles mixtes linéaires, la méthode de Tukey ajustée, l’analyse de variance de Friedman et des tests de rang signés de Wilcoxon. Résultats : De T0 à T1, 3 implants mis en charge immédiatement ont échoué chez 2 patients. Le taux de survie implantaire obtenu était donc de 91,7% (33/36) et, par patient, de 88,9% (16/18). Aucun implant témoin n’a échoué. Les changements osseux documentés radiologiquement et par sondage autour des implants mis en charge immédiatement étaient, respectivement, de -0,2 ± 0,3 mm et de -0,5 ± 0,6 mm. Les pertes d’os de support implantaire n’ont pas été démontrées statistiquement différentes entre les implants avec mise en charge immédiate et les témoins. Les niveaux moyens de stabilité implantaire ont augmenté de 5 ISQ indépendamment de la mise en charge. Les niveaux moyens d’ISQ n’ont pas été démontrés statistiquement différents entre les implants avec mise en charge immédiate et les témoins à T0 ou T1. Cinq des 18 patients n’ont expérimenté aucune complication clinique, alors que 9 en ont eu au moins deux. Hormis les échecs implantaires, aucune de ces complications n’a entraîné de changements au protocole. Conclusion : Les résultats à court terme suggèrent que : (1) le taux de survie implantaire suite au protocole immédiat est similaire à ceux rapportés lors d’un protocole de mise en charge conventionnel (2) les changements d’os de support implantaire et de stabilité ne sont pas différents comparativement à ceux d’un implant témoin, (3) un niveau élevé d’expérience clinique et chirurgicale est requis pour effectuer les procédures et pour gérer les complications associées. Ces résultats préliminaires devraient être confirmés dans une étude clinique de phase II.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Problématique : La majorité des études publiées sur la réhabilitation par mise en charge immédiate de deux implants non jumelés avec une prothèse totale mandibulaire de recouvrement n’ont rapporté que des mesures cliniques objectives et très peu ont évalué les mesures centrées sur le patient, et ce, avec des erreurs de mesure. Aucune étude n’a évalué les attentes des patients vis-à-vis d'un tel protocole. Objectifs : Évaluer les attentes, le niveau de satisfaction ainsi que la qualité de vie reliée à la santé bucco-dentaire des édentés complets suite à un protocole de mise en charge immédiate. Méthodologie : Cet essai clinique de phase 1 utilise un design pré-post afin d’évaluer les mesures centrées sur le patient. Dix-huit individus, complètement édentés et âgés en moyenne de 62,39 ± 7,65 ans, ont reçu une prothèse totale mandibulaire de recouvrement sur deux implants non jumelés suite à un protocole de mise en charge immédiate, conjointement à une prothèse totale conventionnelle maxillaire. Un instrument adapté pour mesurer leurs attentes à l’aide d’échelles visuelles analogues, le questionnaire « McGill Denture Satisfaction Instrument » ainsi que le questionnaire OHIP-20 ont été remis aux patients avant de procéder aux traitements (T0), ainsi qu’aux rendez-vous de suivi à 2 semaines (T1), 1 mois (T2) et 4 mois (T3). De plus, l’inventaire de personnalité révisé (NÉO PI-R) ainsi qu’un questionnaire sociodémographique ont été remplis par les participants. Les « change scores » ont été calculés puis des tests non paramétriques et des analyses de variances en mesures répétées suivies de comparaisons par paires ont été utilisés afin d’analyser les données recueillies. La taille d’effet a été estimée. Résultats : Les participants avaient différentes attentes par rapport à la mise en charge immédiate. Certains s’attendaient à un effet positif à court terme par rapport à leur apparence esthétique (83,3 %) et à leur vie sociale (55,7 %), alors que d’autres avaient des craintes envers leur confort (5,6 %), leur habileté à mastiquer (11,1 %) et à nettoyer leur prothèse inférieure (11,1 %). À 4 mois, le protocole de mise en charge immédiate avait rencontré la majorité des attentes des patients par rapport à l’esthétique (94.4 %), la mastication (83.3 %), la phonétique (61.1 %), le confort (94.4 %), l’hygiène (88.9 %) et leur vie sociale (88.9 %). Une amélioration statistiquement significative de la satisfaction en générale, du confort, de l’esthétique, de la stabilité de la prothèse inférieure et de l’habileté à mastiquer a été notée à 2 semaines (p<0,001). Également, les comparaisons par paires ont révélé une diminution statistiquement significative du score total de l’OHIP-20 (p < 0,001) de même que la majorité des domaines de l’OHIP (p < 0.01), sauf pour l’handicap social qui n’a diminué significativement qu’après 1 mois (p = 0.01). Ces changements (pour la satisfaction et la qualité de vie) sont restés stables au cours des suivis subséquents. Indépendamment des traits de personnalité et des variables sociodémographiques, le protocole immédiat a satisfait 94,4 % des participants et a amélioré leur qualité de vie avec une large magnitude d’effet (d = 1.9; p < 0.001). Bien que deux patients aient perdu des implants au cours du traitement, 100 % des participants étaient d’accord pour recommander cette procédure à leurs pairs. Conclusions: Le protocole de mise en charge immédiate semble satisfaire les patients quelles que soient leurs attentes. Le protocole MCI peut améliorer, à court terme, la qualité de vie des patients totalement édentés. Les résultats prometteurs de la phase 1 devraient être corroborés lors de la 2e phase de cette étude.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In his forum paper, Prof. Kevin Warwick considers four different examples of how the use of implant technology is opening up the possibility of upgrading human abilities, particularly in terms of mental cognition. The main thrust is an overview of Prof. Warwick's own research, which led to him receiving a neural implant linking his nervous system bi-directionally with the internet. With this implant in place, neural signals were transmitted to various technological devices to directly control them, in some cases via the internet, and feedback to the brain was obtained from such stimuli as the fingertips of a robot hand, ultrasonic (extra-) sensory input and neural signals directly from another human's nervous system. A view is taken as to the prospects for the future, both in the short-term as a therapeutic device and in the long-term as a form of enhancement, including the realistic potential, in the near future, for thought communication – thereby opening up tremendous commercial potential. The therapy/enhancement dichotomy is considered here, as well as military and medical issues. Clearly though, an individual whose brain is part human/part machine can have abilities that far surpass those who remain with a human brain alone. Will such an individual exhibit different moral and ethical values to those of a human? If so, what effects might this have on society?

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the biomechanical fixation, bone-to-implant contact (BIC), and bone morphology of screw-type root-form implants with healing chambers with as-machined or dual acid-etched (DAE) surfaces in a canine model. Materials and Methods: The animal model included the placement of machined (n = 24) and DAE (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Following euthanasia, half of the specimens were subjected to biomechanical testing (torque to interface failure) and the other half were processed for histomorphologic and histomorphometric (%BIC) assessments. Statistical analyses were performed by one-way analysis of variance at the 95% confidence level and the Tukey post hoc test for multiple comparisons. Results: At 4 weeks, the DAE surface presented significantly higher mean values for torque to interface failure overall. A significant increase in %BIC values occurred for both groups over time. For both groups, bone formation through the classic appositional healing pathway was observed in regions where intimate contact between the implant and the osteotomy walls occurred immediately after implantation. Where contact-free spaces existed after implantation (healing chambers), an intramembranous-like healing mode with newly formed woven bone prevailed. Conclusions: In the present short-term evaluation, no differences were observed in BIC between groups; however, an increase in biomechanical fixation was seen from 2 to 4 weeks with the DAE surface. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:75-82

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate a simple mnemonic rule (the RB-RB/LB-LB rule) for recording intra-oral radiographs with optimal projection for the control of dental implants.Methods: 30 third-year dental students received a short lesson in the RB-RB/LB-LB mnemonic rule. The rule is as follows: if right blur then raise beam (RB-RB), i.e. if implant threads are blurred at the right side of the implant, the X-ray beam direction must be raised towards the ceiling to obtain sharp threads on both implant sides; if left blur then lower beam (LB-LB), i.e. if implant threads are blurred at the left side of the implant, the X-ray beam direction must be lowered towards the floor to obtain sharp threads on both implant sides. Intra-oral radiographs of four screw-type implants placed with different inclination in a Frasaco upper or lower jaw dental model (Frasaco GmbH, Tettnang, Germany) were recorded. The students were unaware of the inclination of the implants and were instructed to re-expose each implant, implementing the mnemonic rule, until an image of the implant with acceptable quality (subjectively judged by the instructor) was obtained. Subsequently, each radiograph was blindly assessed with respect to sharpness of the implant threads and assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable and (4) hopeless.Results: For all implants, from one non-perfect exposure to the following, a higher score was obtained in 64% of the cases, 28% received the same score and 8% obtained a lower score. Only a small variation was observed among exposures of implants with different inclination. on average, two exposures per implant (range: one to eight exposures) were needed to obtain a clinically acceptable image.Conclusion: The RB-RB/LB-LB mnemonic rule for recording intra-oral radiographs of dental implants with a correct projection was easy to implement by inexperienced examiners. Dentomaxillofacial Radiology (2012) 41, 298-304. doi: 10.1259/dmfr/20861598

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Calcium phosphate-based bioactive ceramics in various physical and chemical formulations have been extensively utilized as biomaterials for bone regeneration/conduction. However, the determination of their in vivo temporal behavior from the short to long term in humans has been a challenge due to the lack of physical reference for morphologic and morphometric evaluation. The present study evaluated bone morphology and morphometry (bone-to-implant contact [BIC]) around plasma-sprayed hydroxyapatite (PSHA)-coated endosseous implants that were retrieved due to prosthetic reasons while successfully in function at the posterior region of the jaws from as early as 2 months to ~13 years after a 6-month healing period after placement. Bone morphology was evaluated by light microscopy, and BIC was determined using computer software. Irrespective of the time in vivo, lamellar bone was observed in close contact with the implant PSHA-coated surface and between plateaus. BIC ranged from ~35-95%, was highly directional, and Haversian-like osteonic morphology between plateaus was observed for most implants. The PSHA coating was present with little variation in thickness between the samples retrieved regardless of time in vivo. © 2010 by Begell House, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Enhancing osseointegration through surface immobilization of multiple short peptide sequences that mimic extracellular matrix (ECM) proteins, such as arginine-glycine-aspartic acid (RGD) and lysine-arginine-serine-arginine (KRSR), has not yet been extensively explored. Additionally, the effect of biofunctionalizing chemically modified sandblasted and acid-etched surfaces (modSLA) is unknown. The present study evaluated modSLA implant surfaces modified with RGD and KRSR for potentially enhanced effects on bone apposition and interfacial shear strength during early stages of bone regeneration. Two sets of experimental implants were placed in the maxillae of eight miniature pigs, known for their rapid wound healing kinetics: bone chamber implants creating two circular bone defects for histomorphometric analysis on one side and standard thread configuration implants for removal torque testing on the other side. Three different biofunctionalized modSLA surfaces using poly-L-lysine-graft-poly(ethylene glycol) (PLL-g-PEG) as a carrier minimizing nonspecific protein adsorption [(i) 20 pmol cm⁻² KRSR alone (KRSR); or in combination with RGD in two different concentrations; (ii) 0.05 pmol cm⁻² RGD (KRSR/RGD-1); (iii) 1.26 pmol cm⁻² RGD (KRSR/RGD-2)] were compared with (iv) control modSLA. Animals were sacrificed at 2 weeks. Removal torque values (701.48-780.28 N mm), bone-to-implant contact (BIC) (35.22%-41.49%), and new bone fill (28.58%-30.62%) demonstrated no significant differences among treatments. It may be concluded that biofunctionalizing modSLA surfaces with KRSR and RGD derivatives of PLL-g-PEG polymer does not increase BIC, bone fill, or interfacial shear strength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare four different implantation modalities for the repair of superficial osteochondral defects in a caprine model using autologous, scaffold-free, engineered cartilage constructs, and to describe the short-term outcome of successfully implanted constructs. METHODS: Scaffold-free, autologous cartilage constructs were implanted within superficial osteochondral defects created in the stifle joints of nine adult goats. The implants were distributed between four 6-mm-diameter superficial osteochondral defects created in the trochlea femoris and secured in the defect using a covering periosteal flap (PF) alone or in combination with adhesives (platelet-rich plasma (PRP) or fibrin), or using PRP alone. Eight weeks after implantation surgery, the animals were killed. The defect sites were excised and subjected to macroscopic and histopathologic analyses. RESULTS: At 8 weeks, implants that had been held in place exclusively with a PF were well integrated both laterally and basally. The repair tissue manifested an architecture similar to that of hyaline articular cartilage. However, most of the implants that had been glued in place in the absence of a PF were lost during the initial 4-week phase of restricted joint movement. The use of human fibrin glue (FG) led to massive cell infiltration of the subchondral bone. CONCLUSIONS: The implantation of autologous, scaffold-free, engineered cartilage constructs might best be performed beneath a PF without the use of tissue adhesives. Successfully implanted constructs showed hyaline-like characteristics in adult goats within 2 months. Long-term animal studies and pilot clinical trials are now needed to evaluate the efficacy of this treatment strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is a retrospective clinical, radiological and patient outcome assessment of 21 consecutive patients with King 1 idiopathic adolescent scoliosis treated by short anterior selective fusion of the major thoracolumbar/lumbar (TL/L) curve. Three-dimensional changes of both curves, changes in trunk balance and rib hump were evaluated. The minimal follow-up was 24 months (max. 83). The Cobb angle of the TL/L curve was 52 degrees (45-67 degrees) with a flexibility of 72% (40-100%). The average length of the main curve was 5 (3-8) segments. An average of 3 (2-4) segments was fused using rigid single rod implants with side-loading screws. The Cobb angle of the thoracic curve was 33 degrees (18-50 degrees) with a flexibility of 69% (29-100%). The thoracic curve in bending was less than 20 degrees in 17 patients, and 20-25 degrees in 4 patients. In the TL/L curve there was an improvement of the Cobb angle of 67%, of the apex vertebral rotation of 51% and of the apex vertebral translation of 74%. The Cobb angle of the thoracic curve improved 29% spontaneously. Shoulder balance improved significantly from an average preoperative imbalance of 14.5-3.1 mm at the last follow-up. Seventy-five percent of the patients with preoperative positive shoulder imbalance (higher on the side of the thoracic curve) had levelled shoulders at the last follow-up. C7 offset improved from a preoperative 19.8 (0-40) to 4.8 (0-18) mm at the last follow-up. There were no significant changes in rotation, translation of the thoracic curve and the clinical rib hump. There were no significant changes in thoracic kyphosis or lumbar lordosis. The average score of the SRS-24 questionnaire at the last follow-up was 91 points (max. 120). We conclude that short anterior selective fusion of the TL/L curve in King 1 scoliosis with a thoracic curve bending to 25 degrees or less (Type 5 according to Lenke classification) results in a satisfactory correction and a balanced spine. Short fusions leave enough mobile lumbar segments for the establishment of global spinal balance. A positive shoulder imbalance is not a contraindication for this procedure. Structural interbody grafts are not necessary to maintain lumbar lordosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to evaluate the effect of gap width and graft placement on bone healing around implants placed in simulated extraction sockets of various widths in four Labrador dogs. MATERIALS AND METHODS: Five Osseotite implants per dog were placed in the mandible of four dogs. Two implants were inserted into sites with a 2.37 mm and two with a 1 mm gap present between the implants and bone around the coronal 6 mm of the implants in each dog. For one of each gap sizes, the gap was filled with Bio-Oss, and the other two with blood alone. A fifth implant was inserted without a gap and used as a control. Ground sections were prepared from biopsies taken at 4 months and histometric measurements of osseointegration and bone between the threads made for the coronal 6 mm. RESULTS: The medians for osseointegration ranged from 5.2 mm for control to 1-2.6 mm for the test modalities. There were significant differences for linear measurements of osseointegration (chi(2) 18.27; df 4; P=0.0011) and bone area within threads (chi(2) 23.4; df 4; P=0.0001) between test modalities. CONCLUSIONS: The results suggest that the wider the gap around the implants, the less favourable the histological outcome at short time intervals following treatment. They also infer that bone grafting with an organic bovine bone xenograft seems to lead to a more favourable histological outcome for wider circumferential defects but not for narrower defects.