1. Respiratory alkalosis accompanies the clinical syndrome of tetany, precipitates cardiac arrhythmias and predisposes to coronary vasoconstriction. Magnesium plays a critical role in the maintenance of membrane function, and magnesium depletion is often associated with cardiac arrhythmias or vasoconstriction. 2. As technology for detecting circulating ionized magnesium (the most interesting form with respect to physiological and biological properties) is now available in the form of new magnesium-selective electrodes, the effect of respiratory alkalosis induced by voluntary overbreathing for 30 min on circulating ionized magnesium was studied in eight healthy subjects. 3. The total plasma magnesium concentration was not modified by hyperventilation. On the contrary, hyperventilation was associated with a significant reduction in the ionized magnesium concentration of 0.05 (0.02-0.15) mmol/l (median and range) and in the free magnesium fraction of 0.06 (0.01-0.19). During hyperventilation the relative intravascular magnesium mass, calculated from changes in total plasma magnesium concentration and haematocrit, decreased significantly. 4. It is concluded that acute overbreathing reduces the circulating ionized magnesium concentration and the intravascular magnesium mass. It is therefore conceivable that extracellular magnesium deficiency is at least a subsidiary cause of the syndrome of tetany and the cardiac complications that are precipitated by hyperventilation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A review is given about the most relevant advances on the analytical applications of conducting polymers in potentiometric sensors. These organic polymers represent a new class of materials with conducting properties due to its doping by ions. Several polymers already were synthesized such as polypyrrole, polyaniline, polythiophene, among others. Particular attention is devoted to the main advantages supplied by ion selective electrodes and gas sensors using conducting polymers, as well as the incorporation of bioactive elements in these polymers for the construction of biosensors. The correlation between structure, stability and ability to ion exchange of some conducting polymers applied as potentiometric transducers, is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the recent progress in the development of polymeric membranes for ion-selective electrodes. The importance of knowing the mechanism of potential development in membranes for ion-selective electrodes to reach lower detection limits and improve selectivity are discussed. Recent advances and future trends of research on ion-selective electrodes are also reported.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The copper and cadmium complexation properties in natural sediment suspensions of reservoirs of the Tietê River were studied using the solid membrane copper and cadmium ion-selective electrodes. The complexation and the average conditional stability constants were determined under equilibrium conditions at pH=6.00 ± 0.05 in a medium of 1.0 mol L-1 sodium nitrate, using the Scatchard method. The copper and cadmium electrodes presented Nernstian behavior from 1x10-6 to 1x10-3 mol L-1 of total metal concentration. Scatchard graphs suggest two classes of binding sites for both metals. A multivariate study was done to correlate the reservoirs and the variables: complexation properties, size, total organic carbon, volatile acid sulfide, E II and pH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In many fields such as earth science biology, environment and electronics, the knowledge about elemental distributions and chemical speciation is important. The determination of metal levels especially the toxic ones both in the environment and in biological materials are increasingly demanded by the society.Ion selective sensors have become one of the most effective ad powerful means for analytical scientists for the trace level monitoring of metal ions. The wide range of applications ,low material requirements and simplicity of analytical procedure have not only brought ion-selective electrodes in to the lime light of analytical chemistry,but have promoted their use as tools for physiologists,medical researchers,biologists,geologists,environmental protection specialists etc.Potentiometric ion-selective sensors have been developed for the determination of lanthanide ions such as La3+,Nd3+,Pr3+,Sm3+, and Gd3+.The sensors fabricated include both PVC membrane sensor and chemically modified carbon paste sensor. A set of 10 sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied as an indicator electrode in the potentiometric titration and for the determination of metal ions in real samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electroanalytical techniques represent a class of powerful and versatile analytical method which is based on the electrical properties of a solution of the analyte when it is made part of an electrochemical cell. They offer high sensitivity, accuracy, precision and a large linear dynamic range. The cost of instrumentation is relatively low compared to other instrumental methods of analysis. Many solid state electrochemical sensors have been commercialised nowadays. Potentiometry is a very simple electroanalytical technique with extraordinary analytical capabilities. Since valinomycin was introduced as an ionophore for K+, Ion Selective Electrodes have become one of the best studied and understood analytical devices. It can be used for the determination of substances ranging from simple inorganic ions to complex organic molecules. It is a very attractive option owing to the wide range of applications and ease of the use of the instruments employed. They also possess the advantages of short response time, high selectivity and very low detection limits. Moreover, analysis by these electrodes is non-destructive and adaptable to small sample volumes. It has become a standard technique for medical researchers, biologists, geologists and environmental specialists. This thesis presents the synthesis and characterisation of five ionophores. Based on these ionophores, nine potentiometric sensors are fabricated for the determination of ions such as Pb2+, Mn2+, Ni2+, Cu2+ and Sal- ion (Salicylate ion). The electrochemical characterisation and analytical application studies of the developed sensors are also described. The thesis is divided into eight chapters

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The batch-operated bromate/phosphate/acetone/dual catalyst system was studied at four temperatures between 5 and 35 degrees C. The dynamics was simultaneously followed by potential measurements with platinum and bromide selective electrodes, and spectroscopically at two different wavelengths. By simultaneously recording these four time series it was possible to characterize the dynamics of the sequential oscillations that evolve in time. The existence of three sequential oscillatory patterns at each temperature allowed estimating the activation energies in each case. Along with the activation energy of the induction period, it was possible to trace the time evolution of the overall activation energy at four different stages as the reaction proceeds. The study was carried out for two different sets of initial concentrations and it was observed that the overall activation energy increases as reactants turn into products. This finding was propounded as a result of the decrease in the driving force, or the system`s affinity, of the catalytic oxidative bromination of acetone with acidic bromate, as the closed system evolves toward the thermodynamic equilibrium.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This investigation was carried out within the Parana sedimentary basin in São Paulo and Mato Grosso do Sul States, Brazil, and involved the sampling of different spring water samples with the purpose of evaluating their quality for bottling Several methods were utilized for acquiring the hydrochemical data, such as methyl orange end-point titration, potentiometry, ion selective electrodes, spectrophotometry, atomic absorption spectrophotometry and inductively coupled plasma spectrometry The results obtained for the analyzed samples were compared with the guideline values established by the São Paulo State and Brazilian Health Ministry legislations for defining the potable water standards The Brazilian Code for Mineral Waters that was established by Register 7841 published on 8 August 1945 was also taken into account for verifying if the spring waters are mineralized The hydrochemical data allowed the identification of anthropogenic and geogenic inputs of some constituents in most of the samples, which affected the water quality and did not allow them to be utilized for commercial purposes (bottling) The waters of these springs can only become appropriate for human consumption after previous chemical treatment

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The molar single ion activity coefficients associated with hydrogen, copper(II), cadmium(II) and lead(II) ions were determined at 25 degrees C and ionic strengths between 0.100 and 3.00 M (NaClO4), whereas for acetate the ionic strengths were fixed between 0.300 and 2.00 M, held with the same inert electrolyte. The investigation was carried out potentiometrically by using proton-sensitive glass, copper, cadmium and lead ion-selective electrodes and a second-class Hg\Hg-2(CH3COO)(2) electrode. It was found that the activity coefficients of these ions (y(i)) can be assessed through the following empirical equations:log y(H) = -0.542I(0.5) + 0.451I; log y(Cu) = -1.249I(0.5) + 0.912I; log y(Cd) = -0.829I(0.5) + 0.448I(1.5);log y(Pb) = -0.404I(0.5) + 0.117I(2); and log y(Ac) = 0.0370I .

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nanoporous iron (hydr) oxide electrodes are evaluated as phosphate sensors using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The intensity of the reduction peak current (I-cp) of the ferrihydrite working electrode is tied to phosphate concentration at low pH; however, a hematite electrode combined with the use of EIS provided reliable sensing data at multiple pH values. Nanoporous hematite working electrodes produced an impedance phase component (theta) that shifts with increasing phosphate, and, at chosen frequencies, theta values were fitted for the range 1 nM to 0.1 mM phosphate at pH 4 and pH 7 in 5 mM NaClO4.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The freshwater planktonic alga Kirchneriella aperta was grown in batch cultures to stationary growth phase. Copper and lead complexation properties of the exudate from stationary and exponential growth phases were determined by titrations monitored by ion-selective electrodes. Molecular weight fractionation dialysis) and analysis of the titration data (Scatchard Plot) revealed that K. aperta releases metal-complexing ligands. Copper is associated with low and high molecular weight compounds, whereas lead forms complexes with only high molecular weight compounds. Gas-liquid chromatography showed that mannose and rhamnose make up 74% of the total high molecular weight organic material, with uronic acids present at 19%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several freshwater phytoplanktonic species (eukaryotic and prokaryotic) were grown in batch cultures up to stationary phase and quantified by chlorophyll a analysis. The complexation properties (conditional stability constant and total ligand concentration) of their exudates were investigated by complexometric titrations of the culture media using either copper or lead ion-selective electrodes. For most algae, Scatchard plot analysis of the titration data revealed two classes of copper-complexing ligands, one weaker and the other stronger. Strong copper-complexing agents were produced by Cyanophyta mainly in stationary growth phase. During exponential phase, ligand concentrations and the affinity for copper were similar for both Chlorophyta and Cyanophyta. Complexation parameters for Chlorophyta exudates were similar for both growth phases: exponential and stationary. In contrast, ligand concentrations were similar for Cyanophyta, but the conditional stability constants (the strength of association between ligand and metal) were different. Weak lead-complexing ligands were produced exclusively by two Chlorophyta.