90 resultados para sealants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effectiveness of different sealants applied to a nanofiller composite resin. Forty specimens of Filtek Z-350 were obtained after inserting the material in a 6x3 mm stainless steel mold followed by light activation for 20 s. The groups were divided (n=10) according to the surface treatment applied: Control group (no surface treatment), Fortify, Fortify Plus and Biscover LV. The specimens were subjected to simulated toothbrushing using a 200 g load and 250 strokes/min to simulate 1 week, 1, 3 and 6 months and 1 and 3 years in the mouth, considering 10,000 cycles equivalent to 1 year of toothbrushing. Oral-B soft-bristle-tip toothbrush heads and Colgate Total dentifrice at a 1:2 water-dilution were used. After each simulated time, surface roughness was assessed in random triplicate readings. The data were submitted to two-way ANOVA and Tukey's test at a 95% confidence level. The specimens were observed under scanning electron microscopy (SEM) after each toothbrushing cycle. The control group was not significantly different (p>0.05) from the other groups, except for Fortify Plus (p<0.05), which was rougher. No significant differences (p>0.05) were observed at the 1-month assessment between the experimental and control groups. Fortify and Fortify Plus presented a rougher surface over time, differing from the baseline (p<0.05). Biscover LV did not differ (p>0.05) from the baseline at any time. None of the experimental groups showed a significantly better performance (p>0.05) than the control group at any time. SEM confirmed the differences found during the roughness testing. Surface penetrating sealants did not improve the roughness of nanofiller composite resin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To search the literature and assess the short- and long-term release of bisphenol-A (BPA) in human tissues after treatment with dental sealants. DATA Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion with an arbiter. SOURCES Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and Pubmed), EMBASE (via ovid), Cochrane Trials Register and CENTRAL. The reference lists of all eligible studies were hand-searched. STUDY SELECTION In the absence of RCTs, six interventional and two observational studies, examining in vivo BPA release in human salivary, blood and urinary samples, were included. Due to the heterogeneity in methodology and reporting, the main synthesis of the results was qualitative. The quantitative synthesis based on the weighted Z-test could only include two studies. BPA levels identified in saliva ranged from traces below the method's detection limit to 30 μg/ml. In urine, BPA quantities spanned from 0.17 mg/g to 45.4 mg/g. BPA was not traced in any blood sample at any point of time in the relevant studies. The quantitative analysis showed evidence of BPA release one hour after sealant placement compared to the amount traced before restoration (Stouffer's z trend: <0.001). CONCLUSIONS The available evidence on this topic derived from studies that represent a moderate level of evidence. Nevertheless, the available evidence supports that BPA is released in saliva after sealant placement. CLINICAL SIGNIFICANCE From the qualititative and quantitative synthesis of studies, it is reasonable to conclude that BPA is released after placement of some dental pit and fissure sealants in the oral cavity. The biggest quantities are detected in saliva immediately after or one hour after their placement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To assess in vitro the surface roughness (Ra), Vickers hardness (VHN) and surface morphology of resin and glass ionomer materials used for sealants after dynamic erosive challenge. Methods: Twenty specimens of each material were prepared and divided into experimental (erosive challenge) and control groups (n=10): Protect Riva (SDI), Opallis Flow (3M ESPE), Fluroshield (Dentsply), Filtek Z350 XT Flow (3M ESPE). The erosive challenge was performed 4 times per day (90 s) in cola drink and for 2 h in artificial saliva for 7 days. The control specimens were maintained in artificial saliva. Ra and VHN readings were performed before and after erosion. The percentage of hardness loss (%VHN) was obtained after erosion. The surface morphology was evaluated by scanning electron microscopy (SEM). The data were analyzed by ANOVA, Tukey and paired t tests (α=0.05). Results: After erosion and saliva immersion, there was an increase in Ra values for all groups and Riva group showed the highest Ra values. After erosive challenge, Riva and Filtek groups showed significant decrease in VHN values, but Filtek group showed the greatest %VHN. For all groups there was inorganic particle protrusion and matrix degradation after erosion visualized by SEM images. Conclusions: Erosive challenge affected the surface properties of all materials used as sealants, particularly in the Riva and Filtek groups.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: This paper describes the chemistry and properties of polyacid-modified composite resins ("compomers") designed for use in clinical dentistry, and reviews the literature in this area. METHODS: Information has been obtained from over 50 published articles appearing in the dental and biomaterials literature, with studies being principally identified through MedLine. RESULTS: Published work shows that polyacid-modified composite resins constitute a discrete class of polymeric repair material for use in dentistry. Their distinction is that they contain hydrophilic components, and these cause water to be drawn into the material following cure. This triggers an acid-base reaction, and gives the materials certain clinically-desirable properties (fluoride release, buffering capability) that are also associated with glass-ionomer cements. The water uptake leads to a decline in certain, though not all, physical properties. However, clinical studies have shown these materials to perform acceptably in a variety of applications (Class I, Class II and Class V cavities, as fissure sealants and as orthodontic band cements), especially in children's teeth. CONCLUSIONS/SIGNIFICANCE: Polyacid-modified composite resins constitute a versatile class of dental repair material, whose bioactivity confers clinical advantages, and which are particularly useful in children's dentistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ten million people in the UK today are aged over 65. The latest projections estimate that there will be 5 1/2 million more people aged 65 and older in the next 20 years. This projected pattern of population ageing will have profound consequences for dentistry. Minimal intervention dentistry (MID) is a modern evidence-based approach to caries management in dentate patients that uses the 'medical model' whereby disease is controlled by the 'oral physician'. This approach offers considerable benefits over conventional dentistry for older patients. It encourages patients to be responsible for their oral health through the provision of both knowledge and motivation. MID encompasses risk assessment for dental disease, early detection and control of disease processes, and minimally invasive treatment. 

Clinical Relevance: Risk assessment tools can aid the general dental practitioner and the patient to develop a suitable caries prevention programme for that individual and reduce the need for future operative intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High temperature ceramic membranes have interesting possibilities for application in areas of new and developing technologies such as hydrocarbon combustion with carbon dioxide capture and electrochemical promotion of catalysis (EPOC). However, membrane module sealing remains a significant technical challenge. In this work a borosilicate glass sealant (50SiO2·25B2O3·25Na2O, mol%) was developed to fit the requirements of sealing an air separation membrane system at intermediate temperatures (300-600 °C). The seal was assessed by testing the leak rates under a range of conditions. The parameters tested included the effect of flowrate on the leak rate, the heating and cooling rates of the reactor and the range of temperatures under which the system could operate. Tests for durability and reliability were also performed. It was found that the most favourable reactor configuration employed a reactor with the ceramic pellet placed underneath the inner chamber alumina tube (inverted configuration), using a quartz wool support to keep the membrane in place prior to sealing. Using this configuration the new glass-based seal was found to be a more suitable sealant than traditional alternatives; it produced lower leak rates at all desirable flowrates, with the potential for rapid heating and cooling and multiple cycling, allowing for prolonged usage. © 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As piroxenas são um vasto grupo de silicatos minerais encontrados em muitas rochas ígneas e metamórficas. Na sua forma mais simples, estes silicatos são constituídas por cadeias de SiO3 ligando grupos tetrahédricos de SiO4. A fórmula química geral das piroxenas é M2M1T2O6, onde M2 se refere a catiões geralmente em uma coordenação octaédrica distorcida (Mg2+, Fe2+, Mn2+, Li+, Ca2+, Na+), M1 refere-se a catiões numa coordenação octaédrica regular (Al3+, Fe3+, Ti4+, Cr3+, V3+, Ti3+, Zr4+, Sc3+, Zn2+, Mg2+, Fe2+, Mn2+), e T a catiões em coordenação tetrahédrica (Si4+, Al3+, Fe3+). As piroxenas com estrutura monoclínica são designadas de clinopiroxenes. A estabilidade das clinopyroxenes num espectro de composições químicas amplo, em conjugação com a possibilidade de ajustar as suas propriedades físicas e químicas e a durabilidade química, têm gerado um interesse mundial devido a suas aplicações em ciência e tecnologia de materiais. Este trabalho trata do desenvolvimento de vidros e de vitro-cerâmicos baseadas de clinopiroxenas para aplicações funcionais. O estudo teve objectivos científicos e tecnológicos; nomeadamente, adquirir conhecimentos fundamentais sobre a formação de fases cristalinas e soluções sólidas em determinados sistemas vitro-cerâmicos, e avaliar a viabilidade de aplicação dos novos materiais em diferentes áreas tecnológicas, com especial ênfase sobre a selagem em células de combustível de óxido sólido (SOFC). Com este intuito, prepararam-se vários vidros e materiais vitro-cerâmicos ao longo das juntas Enstatite (MgSiO3) - diopsídio (CaMgSi2O6) e diopsídio (CaMgSi2O6) - Ca - Tschermak (CaAlSi2O6), os quais foram caracterizados através de um vasto leque de técnicas. Todos os vidros foram preparados por fusão-arrefecimento enquanto os vitro-cerâmicos foram obtidos quer por sinterização e cristalização de fritas, quer por nucleação e cristalização de vidros monolíticos. Estudaram-se ainda os efeitos de várias substituições iónicas em composições de diopsídio contendo Al na estrutura, sinterização e no comportamento durante a cristalização de vidros e nas propriedades dos materiais vitro-cerâmicos, com relevância para a sua aplicação como selantes em SOFC. Verificou-se que Foi observado que os vidros/vitro-cerâmicos à base de enstatite não apresentavam as características necessárias para serem usados como materiais selantes em SOFC, enquanto as melhores propriedades apresentadas pelos vitro-cerâmicos à base de diopsídio qualificaram-nos para futuros estudos neste tipo de aplicações. Para além de investigar a adequação dos vitro-cerâmicos à base de clinopyroxene como selantes, esta tese tem também como objetivo estudar a influência dos agentes de nucleação na nucleação em volume dos vitro-cerâmicos resultantes á base de diopsídio, de modo a qualificá-los como potenciais materiais hopedeiros de resíduos nucleares radioactivos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivos: Describir si el uso de sangre fresca total (SFT) intraoperatoria en pacientes llevados a procedimientos RACHS 3 y 4 en la Fundación Cardioinfantil, disminuye el sangrado postoperatorio y el volumen de transfusión de elementos sanguíneos, en comparación a aquellos en quienes no se usa SFT. Materiales y métodos: Se realizó un estudio de cohorte histórica, tomando una población menor de 1 año expuesta a la sangre fresca total y comparándola con una población de similares características, llevadas a procedimientos de riesgo similar no expuesta. Los análisis se realizaron mediante pruebas estándar para variables continuas y discretas. Un valor de p menor a 0.05 fue aceptado como signficativo. Resultados: 46 pacientes expuestos a SFT y se compararon con 50 pacientes no expuestos. La principal diferencia entre los grupos fue la edad, siendo mayor en el grupo de no expuestos (3.8 años vs 0.9; p<0.001). El volumen de sangrado postoperatorio fue similar, sin embargo los pacientes expuestos a SFT recibieron mayor volumen de transfusiones, sin ser una diferencia estadísticamente significativa (155cc vs 203cc, P=0.9). No hubo diferencia significativa en complicaciones o mortalidad. Conclusiones: En nuestro estudio no se encontró una disminución en el volumen de sangrado postoperatorio en los pacientes menores de 1 año, sometidos a cirugías catalogadas como RACHS 3 y 4, expuestos a SFT, sin embargo se necesitan estudios clínicos controlados que respondan definitivamente a la pregunta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente trabajo tiene como objetivo mostrar la relación que existe entre la cadena de suministro, global manufacturing y su relación con el desempeño organizacional en el sector manufacturero. El proyecto va a estar divido en tres grandes partes, en primer lugar estará el marco conceptual donde se especificarán los conceptos más significativos que abarcan la investigación, seguido del marco teórico donde se expondrán las teorías y estudios encontrados, analizados y estudiados con el fin de desembocar en la tercer parte que serán las conclusiones y recomendaciones que se darán a partir de los análisis y teorías que compactan el tema de la relación existente entre la cadena de suministro, global manufacturing y el desempeño organizacional.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las actividades de mantenimiento automotriz en el sector de autopartes conlleva el uso de agentes químicos bajo diversas circunstancias de exposición, tanto en las condiciones de manipulación de productos químicos como a las características propias de cada actividad de mantenimiento asociado a las tareas específicas del trabajo. Tradicionalmente la evaluación de contaminantes químicos desde la visión de la Higiene Ocupacional incluye la evaluación cuantitativa de la exposición mediante técnicas instrumentales concretas y estandarizadas, determinando el nivel de concentración en aire a la cual un trabajador se ve expuesto y que, en comparación con valores límites permisibles (VLPs), inducen el establecimiento de medidas de control y vigilancia, según el nivel de riesgo caracterizado. Sin embargo es evidente la limitación de la implementación de esta sistemática en particular en micros y pequeñas empresas que carecen de los recursos suficientes para abordar la problemática de forma objetiva. En este contexto diversas metodologías de evaluación cualitativa o subjetiva se han desarrollado por distintas organizaciones en el mundo con el fin de disminuir la brecha entre el establecimiento de medidas de control y la valoración del riesgo, ofreciendo alternativas confiables para la toma de decisiones preventivas sin la necesidad de acudir a mediciones cuantitativas. Mediante la presente investigación se pretende validar la efectividad en el uso de una herramienta de evaluación simplificada del riesgo químico propuesta por el INRS (Institut National de Recherche et de Sécurité Francés) mediante la determinación del perfil de exposición potencial a contaminantes químicos de la población laboral de 36 almacenes de autopartes ubicados en el barrio la Paz de la ciudad de Bogotá, Colombia, divididos según énfasis de actividades en Partes Externas, Partes Eléctricas e Inyección, Partes Mecánicas, Partes Múltiples, a través de un estudio de corte transversal. El estudio permitió Jerarquizar el riesgo potencial, valorar el riesgo vía inhalatoria y dérmica para finalmente construir el perfil de exposición potencial a contaminantes químicos de trabajadores. La información de las variables de análisis fue consolidada en una herramienta informática diseñada para tal fin, la cual facilito la administración de los datos y su respectivo análisis. Con base en los hallazgos fue posible establecer los productos químicos que de acuerdo a las condiciones de trabajo y circunstancias de exposición sugieren medidas específicas para la disminución del riesgo potencial de acuerdo a la calificación global de los agentes, permitiendo deducir la viabilidad de la aplicación de herramientas de valoración cualitativa para la evaluación del riesgo químico como estrategia de prevención primaria.