976 resultados para retinal images


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a low cost but high resolution retinal image acquisition system of the human eye. The images acquired by a CMOS image sensor are communicated through the Universal Serial Bus (USB) interface to a personal computer for viewing and further processing. The image acquisition time was estimated to be 2.5 seconds. This system can also be used in telemedicine applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a low cost but high resolution retinal image acquisition system of the human eye. The images acquired by a CMOS image sensor are communicated through the Universal Serial Bus (USB) interface to a personal computer for viewing and further processing. The image acquisition time was estimated to be 2.5 seconds. This system can also be used in telemedicine applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study develops a neuromorphic model of human lightness perception that is inspired by how the mammalian visual system is designed for this function. It is known that biological visual representations can adapt to a billion-fold change in luminance. How such a system determines absolute lightness under varying illumination conditions to generate a consistent interpretation of surface lightness remains an unsolved problem. Such a process, called "anchoring" of lightness, has properties including articulation, insulation, configuration, and area effects. The model quantitatively simulates such psychophysical lightness data, as well as other data such as discounting the illuminant, the double brilliant illusion, and lightness constancy and contrast effects. The model retina embodies gain control at retinal photoreceptors, and spatial contrast adaptation at the negative feedback circuit between mechanisms that model the inner segment of photoreceptors and interacting horizontal cells. The model can thereby adjust its sensitivity to input intensities ranging from dim moonlight to dazzling sunlight. A new anchoring mechanism, called the Blurred-Highest-Luminance-As-White (BHLAW) rule, helps simulate how surface lightness becomes sensitive to the spatial scale of objects in a scene. The model is also able to process natural color images under variable lighting conditions, and is compared with the popular RETINEX model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To examine the association between a posteriori–derived dietary patterns (DP) and retinal vessel caliber in an elderly population.

Methods. This was a cross-sectional study of 288 elderly adults (>65 years) who participated in the European Eye study (EUREYE) Northern Irish cohort. DP were extracted using principal component analysis from completed food frequency questionnaires. Semi-automated computer grading was used to determine the mean retinal vessel diameters (central retinal arteriole equivalent [CRAE] and central retinal venule equivalent [CRVE]) from digitized visual field one images using a standard measurement protocol.

Results. Three major DP were identified in this population, which accounted for 21% of the total variance: a “healthy” pattern with high factor loadings for oily fish, fruits and vegetables, and olive oil; an “unhealthy” pattern with high factor loadings for red and processed meat, refined grains, eggs, butter, sugar and sweets; and a “snack and beverage” pattern with high factor loading for pizza, nuts, and coffee. Multivariable linear regression analysis indicated no significant association between major identified DP and mean CRAE or CRVE in all models.

Conclusions. This is the first study to investigate associations between a posteriori–derived DP and retinal vessel caliber. There was no evidence of a relationship between extracted DP and retinal vessel measurements in this population. However, it is possible that potentially important relationships exist between single nutrients or foods and vessel diameters that cannot be identified using a DP approach. Further studies to examine the role of dietary factors in the microcirculation are required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To describe the occurrence of geographic atrophy in patients with retinal angiomatous proliferation (RAP). Methods: Demographics, visual acuity, color fundus photographs, fluorescein and indocyanine green angiograms, and fundus autofluorescence and near-infrared autofluorescence images were reviewed in 53 patients (66 eyes) with RAP. Results: Of 53 treatment-naive eyes, 19 (36%) had atrophy at baseline. Of 66 eyes, 57 (86%) developed de novo atrophy or enlargement of preexisting areas of atrophy during the follow-up (median, 17 months; range, 3-53 months) after treatment. Areas of atrophy were observed at the site of the RAP (58 of 66 eyes, 88%) of a previously existing pigment epithelial detachment (18 of 44 eyes; 41%) and elsewhere (43 of 66 eyes, 65%). At presentation, RAP was found to be frequently associated with increased autofluorescence at the fovea because of cystoid macular edema (36 of 53 eyes, 68%) and reduced autofluorescence because of hard exudation (38 of 53 eyes, 72%) and intraretinal hemorrhages (32 of 53 eyes, 60%). Background reticular (39%) and homogeneous (36%) autofluorescence were most commonly observed. Conclusion: Geographic atrophy occurs frequently in patients with RAP after treatment. This information, if confirmed in other cohorts, would be valuable for the counseling of patients with this disease and for the understanding of the pathogenesis of this condition and its progression after treatment. Copyright © 2011 Lippincott Williams &Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE:: To evaluate the occurrence of retinal pigment epithelial atrophy in patients with age-related macular degeneration undergoing anti-vascular endothelial growth factor therapy. METHODS:: The study is a retrospective review. Eligible were patients with age-related macular degeneration and choroidal neovascular membranes treated with anti-vascular endothelial growth factor between October 2007 and February 2011; they were followed for >3 months, with fundus photographs and fluorescein angiography at baseline and with autofluorescence and near-infrared autofluorescence images at baseline and follow-up. Demographics, visual acuity, the type of choroidal neovascular membranes, the number of treatments performed, and the length of follow-up were recorded. Autofluorescence and near-infrared autofluorescence images were evaluated for the presence or absence of areas of reduced signal. A multilevel logistic regression model was used to investigate the factors that may be associated with progression of atrophy at follow-up, which was the primary outcome of this study. RESULTS:: Sixty-three patients (72 eyes) were followed for a median of 16 months (range, 3-36 months). Atrophy at baseline was observed in 47% (34/72) of eyes; progression of atrophy occurred in 62% (45/72) of eyes at the last visit. The number of anti-vascular endothelial growth factor injections received was statistically significantly associated with the progression of atrophy at follow-up (odds ratio, 1.35; 95% confidence interval, 1.05-1.73; P = 0.02). CONCLUSION:: Atrophy was frequently observed in patients with age-related macular degeneration and choroidal neovascular membranes undergoing anti-vascular endothelial growth factor therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

• PURPOSE: To evaluate retinal pigment epithelial (RPE) atrophy in patients with Stargardt disease using autofluorescence imaging (AF). • DESIGN: Retrospective observational case series. • METHODS: Demographics, best-corrected visual acuity (BCVA), AF images, and electrophysiology responses (group 1, macular dysfunction; group 2, macula + cone dysfunction; group 3, macula + cone-rod dysfunction) were evaluated at presentation and follow-up in a group of 12 patients (24 eyes) with Stargardt disease. The existence, development, and rate of enlargement of areas of RPE atrophy over time were evaluated using AF imaging. A linear regression model was used to investigate the effects of AF and electrophysiology on rate of atrophy enlargement and BCVA, adjusting for age of onset and duration of disease. • RESULTS: Eight male and 4 female patients (median age 42 years; range 24-69 years) were followed for a median of 41.5 months (range 13-66 months). All 12 patients had reduced AF compatible with RPE atrophy at presentation and in all patients the atrophy enlarged during follow-up. The mean rate of atrophy enlargement for all patients was 1.58 mm /y (SD 1.25 mm /y; range 0.13-5.27 mm /y). Only the pattern of functional loss present as detected by electrophysiology was statistically significantly associated with the rate of atrophy enlargement when correcting for other variables (P <.001), with patients in group 3 (macula + cone-rod dysfunction) having the fastest rate of atrophy enlargement (1.97 mm /y, SD 0.70 mm /y) (group 1 [macula] 1.09 mm /y, SD 0.53 mm /y; group 2 [macula + cone] 1.89 mm /y, SD 2.27 mm /y). • CONCLUSION: Variable rates of atrophy enlargement were observed in patients with Stargardt disease. The pattern of functional loss detected on electrophysiology was strongly associated with the rate of atrophy enlargement over time, thus serving as the best prognostic indicator for patients with this inherited retinal disease. © 2012 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim - To describe a new method of evaluating the topographic distribution of fundus autofluorescence in eyes with retinal disease. Methods - Images of fundus autofluorescence were obtained in five patients and 34 normal volunteers using a confocal scanning laser ophthalmoscope (cSLO). To evaluate the topographic distribution of fundus autofluorescence throughout the posterior pole a rectangular box, 10 x 750 pixels, was used as the area of analysis. The box was placed, horizontally, across the macular region. The intensity of fundus autofluorescence of each pixel within the rectangular box was plotted against its degree of eccentricity. Profiles of fundus autofluorescence from patients were compared with those obtained from the age matched control group and with cSLO images. Results - Profiles of fundus autofluorescence appeared to represent the topographic distribution of fundus autofluorescence throughout the posterior pole appreciated in the cSLO images, and allowed rapid identification and quantification of areas of increased or decreased fundus autofluorescence. Conclusions - Fundus autofluorescence profiles appear to be useful to study the spatial distribution of fundus autofluorescence in eyes with retinal disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pressure myography studies have played a crucial role in our understanding of vascular physiology and pathophysiology. Such studies depend upon the reliable measurement of changes in the diameter of isolated vessel segments over time. Although several software packages are available to carry out such measurements on small arteries and veins, no such software exists to study smaller vessels (<50 µm in diameter). We provide here a new, freely available open-source algorithm, MyoTracker, to measure and track changes in the diameter of small isolated retinal arterioles. The program has been developed as an ImageJ plug-in and uses a combination of cost analysis and edge enhancement to detect the vessel walls. In tests performed on a dataset of 102 images, automatic measurements were found to be comparable to those of manual ones. The program was also able to track both fast and slow constrictions and dilations during intraluminal pressure changes and following application of several drugs. Variability in automated measurements during analysis of videos and processing times were also investigated and are reported. MyoTracker is a new software to assist during pressure myography experiments on small isolated retinal arterioles. It provides fast and accurate measurements with low levels of noise and works with both individual images and videos. Although the program was developed to work with small arterioles, it is also capable of tracking the walls of other types of microvessels, including venules and capillaries. It also works well with larger arteries, and therefore may provide an alternative to other packages developed for larger vessels when its features are considered advantageous.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The pig eye is similar to the human eye in terms of anatomy, vasculature, and photoreceptor distribution, and therefore provides an attractive animal model for research into retinal disease. The purpose of this study was to characterize retinal histology in the developing and mature pig retina using antibodies to well established retinal cell markers commonly used in rodents.

METHODS: Eyes were enucleated from fetuses in the 9th week of gestation, 1 week old piglets and 6 months old adult animals. Eyeglobes were fixed and cryosectioned. A panel of antibodies to well established retinal markers was employed for immunohistochemistry. Fluorescently labeled secondary antibodies were used for signal detection, and images were acquired by confocal microscopy. Mouse retina at postnatal day (P) 5 was used as a reference for this study to compare progression of histogenesis. Most of the primary antibodies have previously been used on mouse tissue.

RESULTS: Most of the studied markers were detected in midgestation pig retina, and the majority had a similar distribution in pig as in P5 mouse retina. However, rhodopsin immunolabeling was detected in pig retina at midgestation but not in P5 mouse retina. Contrary to findings in all rodents, horizontal cells were Islet1-positive and cones were calbindin-immunoreactive in pig retina, as has also been shown for the primate retina. Recoverin and rhodopsin immunolabeling revealed an increase in the length of photoreceptor segments in 6 months, compared to 1 week old animals.

CONCLUSIONS: Comparison with the published data on human retina revealed similar marker distribution and histogenesis progression in the pig and human retina, supporting the pig as a valuable animal model for studies on retinal disease and repair. Furthermore, this study provides information about the dynamics of retinal histogenesis in the pig and validates a panel of antibodies that reliably detects developing and mature retinal cell phenotypes in the pig retina.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Efficient optic disc segmentation is an important task in automated retinal screening. For the same reason optic disc detection is fundamental for medical references and is important for the retinal image analysis application. The most difficult problem of optic disc extraction is to locate the region of interest. Moreover it is a time consuming task. This paper tries to overcome this barrier by presenting an automated method for optic disc boundary extraction using Fuzzy C Means combined with thresholding. The discs determined by the new method agree relatively well with those determined by the experts. The present method has been validated on a data set of 110 colour fundus images from DRION database, and has obtained promising results. The performance of the system is evaluated using the difference in horizontal and vertical diameters of the obtained disc boundary and that of the ground truth obtained from two expert ophthalmologists. For the 25 test images selected from the 110 colour fundus images, the Pearson correlation of the ground truth diameters with the detected diameters by the new method are 0.946 and 0.958 and, 0.94 and 0.974 respectively. From the scatter plot, it is shown that the ground truth and detected diameters have a high positive correlation. This computerized analysis of optic disc is very useful for the diagnosis of retinal diseases

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neuronal circuits in the retina analyze images according to qualitative aspects such as color or motion, before the information is transmitted to higher visual areas of the brain. One example, studied for over the last four decades, is the detection of motion direction in ‘direction selective’ neurons. Recently, the starburst amacrine cell, one type of retinal interneuron, has emerged as an essential player in the computation of direction selectivity. In this study the mechanisms underlying the computation of direction selective calcium signals in starburst cell dendrites were investigated using whole-cell electrical recordings and two-photon calcium imaging. Analysis of the somatic electrical responses to visual stimulation and pharmacological agents indicated that the directional signal (i) is not computed presynaptically to starburst cells or by inhibitory network interactions. It is thus computed via a cell-intrinsic mechanism, which (ii) depends upon the differential, i.e. direction selective, activation of voltage-gated channels. Optically measuring dendritic calcium signals as a function of somatic voltage suggests (iii) a difference in resting membrane potential between the starburst cell’s soma and its distal dendrites. In conclusion, it is proposed that the mechanism underlying direction selectivity in starburst cell dendrites relies on intrinsic properties of the cell, particularly on the interaction of spatio-temporally structured synaptic inputs with voltage-gated channels, and their differential activation due to a somato-dendritic difference in membrane potential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate placement of lesions is crucial for the effectiveness and safety of a retinal laser photocoagulation treatment. Computer assistance provides the capability for improvements to treatment accuracy and execution time. The idea is to use video frames acquired from a scanning digital ophthalmoscope (SDO) to compensate for retinal motion during laser treatment. This paper presents a method for the multimodal registration of the initial frame from an SDO retinal video sequence to a retinal composite image, which may contain a treatment plan. The retinal registration procedure comprises the following steps: 1) detection of vessel centerline points and identification of the optic disc; 2) prealignment of the video frame and the composite image based on optic disc parameters; and 3) iterative matching of the detected vessel centerline points in expanding matching regions. This registration algorithm was designed for the initialization of a real-time registration procedure that registers the subsequent video frames to the composite image. The algorithm demonstrated its capability to register various pairs of SDO video frames and composite images acquired from patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND/AIM: To compare the ability of confocal scanning laser tomography (CSLT), scanning laser polarimetry (SLP) and optical coherence tomography (OCT) in recognising localised retinal nerve fibre layer (RNFL) defects. METHODS: 51 eyes from 43 patients with glaucoma were identified by two observers as having RNFL defects visible on optic disc photographs. 51 eyes of 32 normal subjects were used as controls. Three masked observers evaluated CSLT, SLP and OCT images to determine subjectively the presence of localised RNFL defects. RESULTS: Interobserver agreement was highest with OCT, followed by SLP and CSLT (mean kappa: 0.83, 0.69 and 0.64, respectively). RNFL defects were identified in 58.8% of CSLT, 66.7% of SLP and 54.9% of OCT (p = 0.02 between SLP and OCT) by at least two observers. In the controls, 94.1% of CSLT, 84.3% of SLP and 94.1% of OCT scans, respectively, were rated as normal (p = 0.02 between CSLT and SLP, and SLP and OCT). CONCLUSION: Approximately 20-40% of localised RNFL defects identified by colour optic disc photographs are not detected by CSLT, SPL or OCT. SLP showed a higher number of false-positive results than the other techniques, but also had a higher proportion of correctly identified RNFL defects in the glaucoma population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In retinal surgery, surgeons face difficulties such as indirect visualization of surgical targets, physiological tremor, and lack of tactile feedback, which increase the risk of retinal damage caused by incorrect surgical gestures. In this context, intraocular proximity sensing has the potential to overcome current technical limitations and increase surgical safety. In this paper, we present a system for detecting unintentional collisions between surgical tools and the retina using the visual feedback provided by the opthalmic stereo microscope. Using stereo images, proximity between surgical tools and the retinal surface can be detected when their relative stereo disparity is small. For this purpose, we developed a system comprised of two modules. The first is a module for tracking the surgical tool position on both stereo images. The second is a disparity tracking module for estimating a stereo disparity map of the retinal surface. Both modules were specially tailored for coping with the challenging visualization conditions in retinal surgery. The potential clinical value of the proposed method is demonstrated by extensive testing using a silicon phantom eye and recorded rabbit in vivo data.