958 resultados para receiving antennas
Resumo:
Objective. To evaluate the safety and immunogenicity of varicella vaccine (VV) in susceptible patients with juvenile rheumatic diseases receiving methotrexate and corticosteroids. Methods. Twenty-five patients with juvenile rheumatic diseases (ages 2-19 years) and 18 healthy children and adolescents (ages 3-18 years) received a single dose of VV. All 25 patients were receiving methotrexate; 13 were also receiving prednisone and 5 were also receiving other disease-modifying antirheumatic drugs. None of the vaccinated patients or controls had a previous history of varicella. Anti-varicella-zoster virus IgG antibody (anti-VZV-IgG) titers were measured by enzyme-linked immunosorbent assay immediately before, 4-6 weeks after, and 1 year after vaccination. The patients were monitored prospectively for adverse reactions related to the vaccine, exposure, and occurrence of varicella. Disease activity was assessed 3 months before and 3 months after VV. Results. Twenty patients and all of the controls had negative preimmunization titers of VZV-IgG, and 5 patients had equivocal levels. Positive VZV-IgG titers were detected in 10 (50%) of 20 seronegative patients and 13 (72.2%) of 18 controls 4-6 weeks after VV (P = 0.2). One year after vaccination, 8 of 10 patients maintained positive VZV-IgG titers. No overt varicella episodes and no severe adverse reactions were observed during the followup period. No worsening of clinical parameters and no flares of juvenile rheumatic diseases or changes in doses of medications used were detected after vaccination. In fact, the number of active joints in patients with juvenile idiopathic arthritis was significantly lower after VV (P = 0.009). Conclusion. VV appears to be safe in patients with juvenile rheumatic diseases receiving methotrexate, as long as continuous prospective vigilance for side effects is performed.
Resumo:
The identification of early markers that predict the response to anti-tuberculosis treatment would facilitate evaluation of new drugs and improve patient management. This study aimed to determine whether selected acute phase proteins and micronutrients measured at the time of diagnosis and during the first weeks of treatment could predict treatment responses during the 2-month standard intensive phase of therapy. For this purpose, alpha 1-antitrypsin, alpha 1-acid gtycoprotein, alpha 2-macroglobutin, C-reactive protein, C3, C4, zinc, copper and selenium concentrations were measured in Brazilian patients with smear-positive tuberculosis at the time of diagnosis and 1, 3, 5 and 8 weeks after initiation of therapy. Patients were classified into fast (n = 29), intermediate (n = 18) and slow responders (n = 10) if they were smear-negative at 3, 5 or 8 weeks of treatment. alpha 1-acid gtycoprotein on enrolment and 1 week of treatment, alpha 1-antitrypsin at week 1 and C-reactive protein and C3 after 3 weeks of therapy were higher in slow responders than in fast responders. alpha 1-antitrypsin and alpha 1-acid glycoprotein may be helpful in predicting treatment response at the time of initiation of therapy, and could be used as early markers to identify patients with an increased likelihood of treatment failure. (C) 2008 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective: To determine whether opportunistic oral infections associated to HIV infection (OOI-HIV) are found in HIV+/AIDS patients with immune reconstitution related to highly active antiretroviral therapy (HAART). Methods. From among 1100 HIV+/AIDS patients (Service of Internal Medicine, Carlos Haya Hospital, Malaga, Spain) subjected to review of the oral cavity between January 1996 and May 2007, we identified those examined in 1996 and which were again examined between 1997 and 2007, and were moreover receiving HAART. The following data were collected: age, gender, form of contagion, antiretroviral therapy at the time of review, number of CD4+ lymphocytes/ml, and viral load (from 1997 onwards). We identified those subjects with an increase in CD4+ lymphocytes/ ml associated to HAART, and classified them as subjects with quantitative evidence of immune reconstitution (QEIR). Among these individuals with QEIR we moreover identified those with undetectable viral loads (QEIR+VL), and differentiated those patients with an increase in CD4+ lymphocytes > 500/ml (QEIRm+VL). In each group we determined the prevalence of OOI-HIV, following the diagnostic recommendations of the EC-Clearinghouse (CDC-Atlanta, USA - WHO). In addition, we analyzed the prevalence of OOI-HIV in the different groups in relation to the duration of HAART. Results. A total of 86 subjects were included (44 females and 42 males; 19 heterosexuals, 34 male homosexuals, and 33 intravenous drug abusers). Forty-two patients showed QEIR: 21 belonged to the QEIR+VL group, and 17 conformed the QEIRm+VL group. The prevalence of OOI-HIV per group was as follows: QEIR = 54.8%; QEIR+VL = 33%; QEIRm+VL = 35%. The most prevalent lesion in all groups was erythematous candidiasis. OOI-HIV increased with the duration of HAART (p=0.008), and were seen to be dependent upon late appearance of the mycotic lesions ( after 24 months under HAART). Conclusions: It is suggested that opportunistic oral infections associated to HIV infection form part of the clinical picture of immune reconstitution inflammatory syndrome, though such infections are of late onset.
Resumo:
Background. In a pilot study, the authors aimed to determine the success rate of dental implants placed in patients who were positive for human immunodeficiency virus (HIV) and were receiving different regimens of highly active anti-retroviral therapy (HAART). They considered patients` levels of cluster of differentiation (CD) 4(+) cells and viral load, and they attempted to verify whether patients with baseline biochemical signs of bone mineral density loss could experience osseointegration impairment. Materials and Methods. One of the authors, a dentist, placed dental implants in the posterior mandibles of 40 volunteers, divided into three groups: one composed of HIV-positive patients receiving protease inhibitor (PI)-based HAART; a second composed of HIV-positive patients receiving nonnucleoside reverse transcriptase inhibitor based HAART (without PI); and a control group composed of HIV-negative participants. The authors assessed pen-implant health six and 12 months after implant loading. They analyzed the success of the implants in relation to CD4(+) cell counts, viral load and baseline pyridinoline and deoxypyridinoline values. Results. The authors followed 59 implants for 12 months after loading. Higher baseline levels of pyridinoline and deoxypyridinoline found in HIV-positive participants did not interfere with osseointegration after 12 months of follow-up. Average pen-implant bone loss after 12 months was 0.49 millimeters in group 1, 0.47 mm in group 2, and 0.55 mm in the control group. Conclusions. The placement of dental implants in HIV-positive patients is a reasonable treatment option, regardless of CD4(+) cell count, viral load levels and type of antiretroviral therapy. Longer, follow-up periods are necessary to ascertain the predictability of the long-term success of dental implants in these patients. Clinical Implications. Limited published scientific evidence is available to guide clinicians in regard to possible increased risks associated with dental implant placement in HIV-positive patients.
Resumo:
There has been no comparison of fluoride (F) intake by pre-school children receiving more traditional sources of systemic F. The aim of this study was to estimate the dietary F intake by children receiving F from artificially fluoridated water (AFW-Brazil, 0.6-0.8 mg F/L), naturally fluoridated water (NFW-Brazil, 0.6-0.9 mg F/L), fluoridated salt (FS-Peru, 180-200 mg F/Kg), and fluoridated milk (FM-Peru, 0.25 mg F). Children (n = 21-26) aged 4-6 yrs old participated in each community. A non-fluoridated community (NoF) was evaluated as the control population. Dietary F intake was monitored by the ""duplicate plate"" method, with different constituents (water, other beverages, and solids). F was analyzed with an ion-selective electrode. Data were tested by Kruskall-Wallis and Dunn`s tests (p < 0.05). Mean (+/- SD) F intake (mg/Kg b.w./day) was 0.04 +/- 0.01(b), 0.06 +/- 0.02(a,b), 0.05 +/- 0.02(a,b), 0.06 +/- 0.01(a), and 0.01 +/- 0.00(c) for AFW/NFW/FS/FM/NoF, respectively. The main dietary contributors for AFW/NFW and FS/FM/NoF were water and solids, respectively. The results indicate that the dietary F intake must be considered before a systemic method of fluoridation is implemented.
Resumo:
In this paper, a small transmit array of transistor amplifiers illuminated by a passive array of microstrip patches in the reactive near-field region is investigated as a power-combining structure. The two cases considered are when the transmit array radiates in a free space and when a passive array similar to the one used for illumination collects the radiated power. A comparison of the performance of the proposed structure against the alternative one, which uses a conventional horn antenna as a power-launching/receiving device, is also presented.
Resumo:
This study investigated the change in body composition in 36 cancer outpatients receiving radiotherapy to the head and neck area (mean age: 63 ± 15 years) randomised to receive either nutrition intervention (NI; n=15) or usual care (UC; n=21). Body weight and composition were measured at the commencement of radiotherapy and 3 months later. The UC group lost significantly more weight; mean decrease = 4.3 kg, than the NI group: mean decrease = 1.1 kg (t(30)=-2.5, p=0.019). Fat-free mass loss was significantly higher in the UC group with a mean loss of 2.2 kg versus 0.3 kg in the NI group (t(30)=- 2.3, p=0.029). Body composition as measured by foot-to-foot bioelectrical impedance analysis provides more information than weight alone and can allow for tailoring of NI.
Resumo:
This paper details an investigation of a power combiner that uses a reflect array of dual-feed aperture-coupled microstrip patch antennas and a corporate-fed dual-polarized array as a signal distributing/combining device. In this configuration, elements of the reflect array receive a linearly polarized wave and retransmit it with an orthogonal polarization using variable-length sections of microstrip lines connecting receive and transmit ports. By applying appropriate lengths of these delay lines, the array focuses the transmitted wave onto the feed array. The operation of the combiner is investigated for a small-size circular reflect array for the cases of -3 dB, -6 dB and -10 dB edge illumination by the 2 x 2-element dual-polarized array.
Resumo:
The suitable use of array antennas in cellular systems results in improvement in the signal-to-interference ratio (StR), This property is the basis for introducing smart or adaptive antenna systems. in general, the SIR depends on the array configuration and is a function of the direction of the desired user and interferers. Here, the SIR performance for linear and circular arrays is analysed and compared.
Resumo:
Resistively loaded helical antennas, used in the normal mode and horizontally polarised, are modelled using the moment method above typical lossy ground. The distributed resistive loading was adjusted to maintain a two octave bandwidth. The centre frequency of 1 m dipoles was reduced from 250 MHz for the straight resistive wire to 50 MHz for a helix of pitch 2.5 cm and diameter 5 cm. The reduction in efficiency required to maintain the bandwidth for this helix was 12 dB. This agrees reasonably with the theory for small antennas in free space. The results were also verified by comparing measurements performed on a monopole resistively loaded helical antenna in a watertank with the numerical model used elsewhere.
Resumo:
For ground penetrating radar (GPR), smaller antennas would provide considerable practical advantages. Some of which are: portability; ease of use; and higher spatial sampling. A theoretical comparison of the fundamental limits of a small electric field antenna and a small magnetic field antenna shows that the minimum Q constraints are identical. Furthermore, it is shown that only the small magnetic loop antenna can be constructed to approach, arbitrarily closely, the fundamental minimum Q limit. This is achieved with the addition of a high permeability material which reduces energy stored in the magnetic fields. This is of special interest to some GPR applications. For example, applications requiring synthetic aperture data collection would benefit from the increased spatial sampling offered by electrically smaller antennas. Low frequency applications may also benefit, in terms of reduced antenna dimensions, by the use of electrically small antennas. Under these circumstances, a magnetic type antenna should be considered in preference to the typical electric field antenna. Numerical modeling data supports this assertion.
Resumo:
Indoor localization systems in nowadays is a huge area of interest not only at academic but also at industry and commercial level. The correct location in these systems is strongly influenced by antennas performance which can provide several gains, bandwidths, polarizations and radiation patterns, due to large variety of antennas types and formats. This paper presents the design, manufacture and measurement of a compact microstrip antenna, for a 2.4 GHZ frequency band, enhanced with the use of Electromagnetic Band-Gap (EBG) structures, which improve the electromagnetic behavior of the conventional antennas. The microstrip antenna with an EBG structure integrated allows an improvement of the location system performance in about 25% to 30% relatively to a conventional microstrip antenna.
Resumo:
Objective - The study evaluated the effect of a canned sardine supplement in C-reactive protein (CRP) in patients on hemodialysis (HD) and the compliance and adherence to this supplement. Design - This was a quasi-experimental study: Participants with a serum CRP of 5 mg/dL or less volunteered to consume a sardine supplement or were maintained on the usual cheese/ham sandwich supplement. Setting - The study took place in two outpatient dialysis units in Lisbon, Portugal. Patients - The study comprised 63 patients receiving maintenance HD three times per week for at least 6 months and an initial CRP concentration of 5 mg/dL or less. Exclusion criteria included the presence of graft vascular access or history of cancer. Intervention - After a 4-week washout period, the nutritional intervention included a canned sardine sandwich for the case group (n = 31) and a cheese or ham sandwich for the control group (n = 32), to be ingested during each routine HD session, 3 times per week, for 8 weeks. Main outcome measure - Serum levels of high-sensitivity CRP were the outcome measure. Results - Only 65 patients from the invited 186 patients met the inclusion criteria and agreed to eat the sardine sandwich supplement three times per week and were involved in the study. A significant proportion of 48% (n = 31, case group) consumed the sardine sandwich supplement three times per week for 8 weeks, fulfilling the requirements and completing the study. The present investigation showed that a sardine sandwich supplement had no effect on CRP levels among patients on HD. However, when participants were stratified according to tertiles of CRP distribution values at baseline, a reduction in CRP levels was found for those in the higher tertile, being higher for the case group (P = .047). Although diabetic patients were excluded from the analysis (eight in the sardine supplementation group and seven in the control group) a significant CRP reduction was found (P = .034). Conclusion - Although a supplement of low-dose n-3 long-chain polyunsaturated fatty acids had no effect on the plasma high-sensitivity CRP of the supplemented group, a reduction in CRP levels was found when patients were stratified for tertiles of CRP (for the upper tertile) and diabetic status (for nondiabetic patients). These findings need to be further confirmed. This canned sardine supplement was accepted by an important proportion of patients, enhancing diet variety and contributing for a greater n-3 long-chain polyunsaturated fatty acids eicosapentaenoic acid and docosahexaenoic acid intake.
Resumo:
Radio frequency (RF) energy harvesting is an emerging technology that will enable to drive the next generation of wireless sensor networks (WSNs) without the need of using batteries. In this paper, we present RF energy harvesting circuits specifically developed for GSM bands (900/1800) and a wearable dual-band antenna suitable for possible implementation within clothes for body worn applications. Besides, we address the development and experimental characterization of three different prototypes of a five-stage Dickson voltage multiplier (with match impedance circuit) responsible for harvesting the RF energy. Different printed circuit board (PCB) fabrication techniques to produce the prototypes result in different values of conversion efficiency. Therefore, we conclude that if the PCB fabrication is achieved by means of a rigorous control in the photo-positive method and chemical bath procedure applied to the PCB it allows for attaining better values for the conversion efficiency. All three prototypes (1, 2 and 3) can power supply the IRIS sensor node for RF received powers of -4 dBm, -6 dBm and -5 dBm, and conversion efficiencies of 20, 32 and 26%, respectively. © 2014 IEEE.