996 resultados para preliminary questions
Resumo:
SRI has examined the organosolv (organic solvation) pulping of Australian bagasse using technology supplied by Ecopulp. In the process, bagasse is reacted with aqueous ethanol in a digester at elevated temperatures (between 150ºC and 200ºC). The products from the digester are separated using proprietary technology before further processing into a range of saleable products. Test trials were undertaken using two batch digesters; the first capable of pulping about 25 g of wet depithed bagasse and the second, larger samples of about 1.5 kg of wet depithed bagasse. From this study, the unbleached pulp produced from fresh bagasse did not have very good strength properties for the production of corrugated medium for cartons and bleached pulp. In particular, the lignin contents as indicated by the Kappa number for the unbleached pulps are high for making bleached pulp. However, in spite of the high lignin content, it is possible to bleach the pulp to acceptable levels of brightness up to 86.6% ISO. The economics were assessed for three tier pricing (namely low, medium and high price). The economic return for a plant that produces 100 air dry t/d of brownstock pulp is satisfactory for both high and medium pricing levels of pricing. The outcomes from the project justify that work should continue through to either pilot plant or upgraded laboratory facility.
Resumo:
OBJECTIVE The aim of this research project was to obtain an understanding of the barriers to and facilitators of providing palliative care in neonatal nursing. This article reports the first phase of this research: to develop and administer an instrument to measure the attitudes of neonatal nurses to palliative care. METHODS The instrument developed for this research (the Neonatal Palliative Care Attitude Scale) underwent face and content validity testing with an expert panel and was pilot tested to establish temporal stability. It was then administered to a population sample of 1285 neonatal nurses in Australian NICUs, with a response rate of 50% (N 645). Exploratory factor-analysis techniques were conducted to identify scales and subscales of the instrument. RESULTS Data-reduction techniques using principal components analysis were used. Using the criteria of eigenvalues being 1, the items in the Neonatal Palliative Care Attitude Scale extracted 6 factors, which accounted for 48.1% of the variance among the items. By further examining the questions within each factor and the Cronbach’s of items loading on each factor, factors were accepted or rejected. This resulted in acceptance of 3 factors indicating the barriers to and facilitators of palliative care practice. The constructs represented by these factors indicated barriers to and facilitators of palliative care practice relating to (1) the organization in which the nurse practices, (2) the available resources to support a palliative model of care, and (3) the technological imperatives and parental demands. CONCLUSIONS The subscales identified by this analysis identified items that measured both barriers to and facilitators of palliative care practice in neonatal nursing. While establishing preliminary reliability of the instrument by using exploratory factor-analysis techniques, further testing of this instrument with different samples of neonatal nurses is necessary using a confirmatory factor-analysis approach.
Resumo:
Reflecting its importance to thc financial success of organisations, interest in consumer loyalty continues unabated. However, there are still many unanswered questions about its conceptualisation and measurement.These questions must he resolved before academics and practitioners can usefully apply the concept. We argue that consumer loyalty is best conceptualised as a multi-dimensional phenomenon. Based on this multi-dimensional view, we develop and test a new measure of consumer loyalty. We hypothesise a threedimensional structure containing affective, temporal and instrumental dimensions, Results from a preliminary test are reported. The results indicate that the construct can be reprcxeuted with two dimensions: affective and temporal loyally. As an additional check on the reliability of our results, we find significant correlations between these two dimensions and a measure of behavioural loyalty.
Resumo:
The National survey was the third phase in an ongoing initiative to identify critical success factors in ICT mediated supply chains. This study has been designed to harness the tacit and explicit knowledge to be found on the subject from the widest range of appropriate sources. At its core is the assumption that, provided with the fullest list of candidate success factors, a representative sample of experienced industry-based practitioners will (with the aid of statistical analysis) reveal a set of critical success factors. A postal survey has been judged to be the most appropriate mechanism for achieving this outcome.
Resumo:
Mock circulation loops are used to evaluate the performance of cardiac assist devices prior to animal and clinical testing. A compressible, translucent silicone ventricle chamber that mimics the exact size, shape and motion of a failing heart is desired to assist in flow visualization studies around inflow cannulae during VAD support. The aim of this study was therefore to design and construct a naturally shaped flexible left ventricle and evaluate its performance in a mock circulation loop. The ventricle shape was constructed by the use of CT images taken from a patient experiencing cardiomyopathic heart failure and used to create a 3D image and subsequent mould to produce a silicone ventricle. Different cardiac conditions were successfully simulated to validate the ventricle performance, including rest, left heart failure and VAD support.
Resumo:
This project is an extension of a previous CRC project (220-059-B) which developed a program for life prediction of gutters in Queensland schools. A number of sources of information on service life of metallic building components were formed into databases linked to a Case-Based Reasoning Engine which extracted relevant cases from each source. In the initial software, no attempt was made to choose between the results offered or construct a case for retention in the casebase. In this phase of the project, alternative data mining techniques will be explored and evaluated. A process for selecting a unique service life prediction for each query will also be investigated. This report summarises the initial evaluation of several data mining techniques.
Resumo:
Biological tissues are subjected to complex loading states in vivo and in order to define constitutive equations that effectively simulate their mechanical behaviour under these loads, it is necessary to obtain data on the tissue's response to multiaxial loading. Single axis and shear testing of biological tissues is often carried out, but biaxial testing is less common. We sought to design and commission a biaxial compression testing device, capable of obtaining repeatable data for biological samples. The apparatus comprised a sealed stainless steel pressure vessel specifically designed such that a state of hydrostatic compression could be created on the test specimen while simultaneously unloading the sample along one axis with an equilibrating tensile pressure. Thus a state of equibiaxial compression was created perpendicular to the long axis of a rectangular sample. For the purpose of calibration and commissioning of the vessel, rectangular samples of closed cell ethylene vinyl acetate (EVA) foam were tested. Each sample was subjected to repeated loading, and nine separate biaxial experiments were carried out to a maximum pressure of 204 kPa (30 psi), with a relaxation time of two hours between them. Calibration testing demonstrated the force applied to the samples had a maximum error of 0.026 N (0.423% of maximum applied force). Under repeated loading, the foam sample demonstrated lower stiffness during the first load cycle. Following this cycle, an increased stiffness, repeatable response was observed with successive loading. While the experimental protocol was developed for EVA foam, preliminary results on this material suggest that this device may be capable of providing test data for biological tissue samples. The load response of the foam was characteristic of closed cell foams, with consolidation during the early loading cycles, then a repeatable load-displacement response upon repeated loading. The repeatability of the test results demonstrated the ability of the test device to provide reproducible test data and the low experimental error in the force demonstrated the reliability of the test data.