963 resultados para precision metrology


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Map units directly related to properties of soil-landscape are generated by local soil classes. Therefore to take into consideration the knowledge of farmers is essential to automate the procedure. The aim of this study was to map local soil classes by computer-assisted cartography (CAC), using several combinations of topographic properties produced by GIS (digital elevation model, aspect, slope, and profile curvature). A decision tree was used to find the number of topographic properties required for digital cartography of the local soil classes. The maps produced were evaluated based on the attributes of map quality defined as precision and accuracy of the CAC-based maps. The evaluation was carried out in Central Mexico using three maps of local soil classes with contrasting landscape and climatic conditions (desert, temperate, and tropical). In the three areas the precision (56 %) of the CAC maps based on elevation as topographical feature was higher than when based on slope, aspect and profile curvature. The accuracy of the maps (boundary locations) was however low (33 %), in other words, further research is required to improve this indicator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zielsetzung: Vergleich von Drug Eluting Bead (DEB)-TACE mit konventioneller TACE bei der Behandlung von ,,intermediate stage-HCC bei Patienten mit Zirrhose. Material und Methodik: 212 Patienten (185 ♂, 27 ♀; mittleres Alter, 67 Jahre) mit Child-Pugh A oder B Leberzirrhose und großem und/oder multinodulärem, irresektablen HCC wurden randomisiert, um das Therapieansprechen nach der Behandlung mit DEB (DC Bead; Biocompatibles, UK) beladen mit Doxorubicin oder konventioneller TACE mit Doxorubicin zu vergleichen. Die Randomisierung wurde nach Child-Pugh Status (A oder B), Performance Status (ECOG 0 oder 1), bilobärer Erkrankung (ja/nein) und frühere kurative Behandlung (ja/nein) stratifiziert. Der primäre Studienendpunkt war das 6-Monats-Tumoransprechen. Eine unabhängige verblindete MRT-Studie wurde durchgeführt, um das Tumoransprechen nach den RECIST Kriterien zu beurteilen. Ergebnisse: DEB-TACE mit Doxorubicin zeigte eine höhere Rate an komplettem Tumoransprechen, objektivem Ansprechen und Tumorkontrolle im Vergleich zur konventionellen TACE (27% vs 22%; 52% vs 44%; and 63% vs 52%; P>0.05). Patienten mit Child-Pugh B Zirrhose, ECOG 1 Performance Status, bilobärer Erkrankung und Rezidiven nach kurativer Behandlung zeigte einen signifikanten Anstieg des objektiven Ansprechens (p = 0.038) im Vergleich zur Kontrollgruppe. Bei Patienten, die mit DEB-TACE behandelt wurden, konnte eine deutliche Reduktion der gravierenden Lebertoxizität erreicht werden. Die Doxorubicin-Nebenwirkungsrate war in der DEB-TACE Gruppe deutlich geringer (p = 0.0001) als in der konventionellen TACEGruppe. Schlussfolgerung: DEB-TACE mit Doxorubicin ist sicher und effektiv in der Behandlung von ,,intermediate-stage HCC und bietet einen signifikanten Vorteil bei Patienten mit fortgeschrittener Erkrankung.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use the recently obtained theoretical expression for the complete QCD static energy at next-to-next-to-next-to leading-logarithmic accuracy to determine r(0)Lambda((MS) over bar) by comparison with available lattice data, where r(0) is the lattice scale and Lambda((MS) over bar) is the QCD scale. We obtain r(0)Lambda((MS) over bar) = 0.622(-0.015)(+0.019) for the zero-flavor case. The procedure we describe can be directly used to obtain r(0)Lambda((MS) over bar) in the unquenched case, when unquenched lattice data for the static energy at short distances becomes available. Using the value of the strong coupling alpha(s) as an input, the unquenched result would provide a determination of the lattice scale r(0).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility of local elastic instabilities is considered in a first¿order structural phase transition, typically a thermoelastic martensitic transformation, with associated interfacial and volumic strain energy. They appear, for instance, as the result of shape change accommodation by simultaneous growth of different crystallographic variants. The treatment is phenomenological and deals with growth in both thermoelastic equilibrium and in nonequilibrium conditions produced by the elastic instability. Scaling of the transformed fraction curves against temperature is predicted only in the case of purely thermoelastic growth. The role of the transformation latent heat on the relaxation kinetics is also considered, and it is shown that it tends to increase the characteristic relaxation times as adiabatic conditions are approached, by keeping the system closer to a constant temperature. The analysis also reveals that the energy dissipated in the relaxation process has a double origin: release of elastic energy Wi and entropy production Si. The latter is shown to depend on both temperature rate and thermal conduction in the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New Global Positioning System (GPS) receivers allow now to measure a location on earth at high frequency (5Hz) with a centimetric precision using phase differential positioning method. We studied whether such technique was accurate enough to retrieve basic parameters of human locomotion. Eight subjects walked on an athletics track at four different imposed step frequencies (70-130steps/min) plus a run at free pace. Differential carrier phase localization between a fixed base station and the mobile antenna mounted on the walking person was calculated. In parallel, a triaxial accelerometer, attached to the low back, recorded body accelerations. The different parameters were averaged for 150 consecutive steps of each run for each subject (total of 6000 steps analyzed). We observed a perfect correlation between average step duration measured by accelerometer and by GPS (r=0.9998, N=40). Two important parameters for the calculation of the external work of walking were also analyzed, namely the vertical lift of the trunk and the velocity variation per step. For an average walking speed of 4.0km/h, average vertical lift and velocity variation were, respectively, 4.8cm and 0.60km/h. The average intra-individual step-to-step variability at a constant speed, which includes GPS errors and the biological gait style variation, were found to be 24. 5% (coefficient of variation) for vertical lift and 44.5% for velocity variation. It is concluded that GPS technique can provide useful biomechanical parameters for the analysis of an unlimited number of strides in an unconstrained free-living environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Accurate and reproducible tibial tunnel placement minimizing the risk of neurovascular damage is a crucial condition for successful arthroscopic reconstruction of the posterior cruciate ligament (PCL). This step is commonly performed under fluoroscopic control. Hypothesis: Performing the tibial tunnel under exclusive arthroscopic control allows accurate and reliable tunnel placement according to recommendations in the literature. Materials and Methods: Between February 2007 and December 2009, 108 arthroscopic single bundle PCL reconstructions in tibial tunnel technique were performed. The routine postoperative radiographs were screened according to previously defined quality criterions. After critical analysis, the radiographs of 48 patients (48 knees) were enrolled in the study. 10 patients had simultaneous ACL reconstruction and 7 had PCL revision surgery. The tibial tunnel was placed under direct arthroscopic control through a posteromedial portal using a standard tibial aming device. Key anatomical landmarks were the exposed tibial insertion of the PCL and the posterior horn of the medial meniscus. First, the centre of the posterior tibial tunnel outlet on the a-p view was determined by digital analysis of the postoperative radiographes. Its distance to the medial tibial spine was measured parallel to the tibia plateau. The mediolateral position was expressed by the ratio between the distance of the tunnel outlet to the medial border and the total width of the tibial plateau. On the lateral view the vertical tunnel position was measured perpendicularly to a tangent of the medial tibial plateau. All measurement were repeated at least twice and carried out by two examiners. Results: The mean mediolateral tunnel position was 49.3 ± 4.6% (ratio), 6.7 ± 3.6 mm lateral to the medial tibial spine. On the lateral view the tunnel centre was 10.1 ± 4.5 mm distal to the bony surface of the medial tibial plateau. Neurovascular damage was observed in none of our patients. Conclusion: The results of this radiological study confirm that exclusive arthroscopic control for tibial tunnel placement in PCL reconstruction yields reproducible and accurate results according to the literature. Our technique avoids radiation, facilitates the operation room setting and enables the surgeon to visualize the anatomic key landmarks for tibial tunnel placement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the toxicity focussing on hepatic, gastrointestinal and cardiac parameters following PRECISION TACE with DC Bead? versus conventional transarterial chemoembolization (cTACE) in the treatment of intermediate-stage hepatocellular carcinoma (HCC). Methods and Materials: This prospective, randomized, multicentre study was conducted under best practice trial management and authorized by local institutional review boards. Informed consent was obtained. 212 patients (185 men/27 women; mean: 67 years) were randomized to be treated with DC Beads? or cTACE. The majority of both groups presented in a more advanced stage. Safety was measured by rate of adverse events (South West Oncology Group criteria) and changes in laboratory parameters. Cardiotoxicity was assessed by means of left ventricular ejection fraction (LVEF) in MRI or echocardiography. The results of the two groups were compared using the chi-square test and Student`s t-test. Results: Mean maximum alanine transaminase increase in the DC Bead group was 50% in the cTACE group (p < 0.001) and 59% for aspartate transaminase (p < 0.001). For bilirubin, mean increase was 5.30±15.13 vs. 13.53±73.89 µmol/L. Concerning gastrointestinal disorders, 120 adverse events (AEs) occurred in 57/93 (61.3%) patients in the DC Bead group vs. 114 in 49/108 (45.4%) in cTACE. Concerning hepatobiliary disorders, serious AEs occurred in 8/93 (8.6%) vs. 11/108 (10.2%) patients. LVEF showed an increase in the DC Bead group by +2.7±10.1 percentage points and a small decrease by -1.5±7.6 in the cTACE group, p=0.018. Conclusion: PRECISION TACE is safe, even in more advanced HCC patients. Serious liver and cardiac toxicity were significantly lower in the DC Bead group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Morphogen gradients infer cell fate as a function of cellular position. Experiments in Drosophila embryos have shown that the Bicoid (Bcd) gradient is precise and exhibits some degree of scaling. We present experimental results on the precision of Bcd target genes for embryos with a single, double or quadruple dose of bicoid demonstrating that precision is highest at mid-embryo and position dependent, rather than gene dependent. This confirms that the major contribution to precision is achieved already at the Bcd gradient formation. Modeling this dynamic process, we investigate precision for inter-embryo fluctuations in different parameters affecting gradient formation. Within our modeling framework, the observed precision can only be achieved by a transient Bcd profile. Studying different extensions of our modeling framework reveals that scaling is generally position dependent and decreases toward the posterior pole. Our measurements confirm this trend, indicating almost perfect scaling except for anterior most expression domains, which overcompensate fluctuations in embryo length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise MEG estimates of neuronal current flow are undermined by uncertain knowledge of the head location with respect to the MEG sensors. This is either due to head movements within the scanning session or systematic errors in co-registration to anatomy. Here we show how such errors can be minimized using subject-specific head-casts produced using 3D printing technology. The casts fit the scalp of the subject internally and the inside of the MEG dewar externally, reducing within session and between session head movements. Systematic errors in matching to MRI coordinate system are also reduced through the use of MRI-visible fiducial markers placed on the same cast. Bootstrap estimates of absolute co-registration error were of the order of 1mm. Estimates of relative co-registration error were <1.5mm between sessions. We corroborated these scalp based estimates by looking at the MEG data recorded over a 6month period. We found that the between session sensor variability of the subject's evoked response was of the order of the within session noise, showing no appreciable noise due to between-session movement. Simulations suggest that the between-session sensor level amplitude SNR improved by a factor of 5 over conventional strategies. We show that at this level of coregistration accuracy there is strong evidence for anatomical models based on the individual rather than canonical anatomy; but that this advantage disappears for errors of greater than 5mm. This work paves the way for source reconstruction methods which can exploit very high SNR signals and accurate anatomical models; and also significantly increases the sensitivity of longitudinal studies with MEG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In decision making, speed-accuracy trade-offs are well known and often inevitable because accuracy depends on being well informed and gathering information takes time. However, trade-offs between speed and cohesion, that is the degree to which a group remains together as a single entity, as a result of their decision making, have been comparatively neglected. We combine theory and experimentation to show that in decision-making systems, speed-cohesion trade-offs are a natural complement to speed-accuracy trade-offs and are therefore of general importance. We then analyse the decision performance of 32 rock ant, Temnothorax albipennis, colonies in experiments in which accuracy of collective decision making was held constant, but time urgency varied. These experiments reveal for the first time an adaptive speed-cohesion trade-off in collective decision making and how this is achieved. In accord with different time constraints, colonies can decide quickly, at the cost of social unity, or they can decide slowly with much greater cohesion. We discuss the similarity between cohesion and the term precision as used in statistics and engineering. This emphasizes the generality of speed versus cohesion/precision trade-offs in decision making and decision implementation in other fields within animal behaviour such as sexually selected motor displays and even certain aspects of birdsong. We also suggest that speed versus precision trade-offs may occur when individuals within a group need to synchronize their activity, and in collective navigation, cooperative hunting and in certain escape behaviours.