863 resultados para power transmission control
Resumo:
The authors discuss an implementation of an object oriented (OO) fault simulator and its use within an adaptive fault diagnostic system. The simulator models the flow of faults around a power network, reporting switchgear indications and protection messages that would be expected in a real fault scenario. The simulator has been used to train an adaptive fault diagnostic system; results and implications are discussed.
Resumo:
This multiple case-based study investigates the relationship between recruiting agents and the UK universities who act as their principals. The current extensive use of agents in UK higher education may be seen as an indicator of the financial impact made by international students. The study analyses the practice of agent management and explores the manner in which power and control interact. The study employed semi-structured interviews and group discussions involving up to 6 respondents from each of the 20 UK case institutions. The qualitative data reveal a considerable variation in the manner in which the universities manage their agency relationships. Through the joint consideration of control measures and use of power, five distinctive approaches have been identified. The study also reveals that over-dependence on agents reduces the power of the principal, and consequently, the principal’s ability to exercise control, particularly in highly competitive global and national markets.
Resumo:
Researches on control for power electronics have looked for original solutions in order to advance renewable resources feasibility, specially the photovoltaic (PV). In this context, for PV renewable energy source the usage of compact, high efficiency, low cost and reliable converters are very attractive. In this context, two improved simplified converters, namely Tri-state Boost and Tri-state Buck-Boost integrated single-phase inverters, are achieved with the presented Tri-state modulation and control schemes, which guarantees the input to output power decoupling control. This feature enhances the field of single-phase PV inverters once the energy storage is mainly inductive. The main features of the proposal are confirmed with some simulations and experimental results. © 2012 IEEE.
Resumo:
This paper proposes a new methodology to control the power flow between a distributed generator (DG) and the electrical power distribution grid. It is used the droop voltage control to manage the active and reactive power. Through this control a sinusoidal voltage reference is generated to be tracked by voltage loop and this loop generates the current reference for the current loop. The proposed control introduces feed-forward states improving the control performance in order to obtain high quality for the current injected to the grid. The controllers were obtained through the linear matrix inequalities (LMI) using the D-stability analysis to allocate the closed-loop controller poles. Therefore, the results show quick transient response with low oscillations. Thus, this paper presents the proposed control technique, the main simulation results and a prototype with 1000VA was developed in the laboratory in order to demonstrate the feasibility of the proposed control. © 2012 IEEE.
Resumo:
Models of different degrees of complexity are found in the literature for the estimation of lightning striking distances and attractive radius of objects and structures. However, besides the oversimplifications of the physical nature of the lightning discharge on which most of them are based, till recently the tridimensional structure configuration could not be considered. This is an important limitation, as edges and other details of the object affect the electric field and, consequently, the upward leader initiation. Within this context, the Self-consistent leader initiation and propagation model (SLIM) proposed by Becerra and Cooray is state-of-the-art leader inception and propagation leader model based on the physics of leader discharges which enables the tridimensional geometry of the structure to be taken into account. In this paper, the model is used for estimating the striking distance and attractive radius of power transmission lines. The results are compared with those obtained from the electrogeometric and Eriksson's models. © 2003-2012 IEEE.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Polymeric insulation is an increasing tendency in projects and maintenance of electrical networks for power distribution and transmission. Electrical power devices (e. g., insulators and surge arresters) developed by using polymeric insulation presents many advantages compared to the prior power components using ceramic insulation, such as: a better performance under high pollution environment; high hydrophobicity; high resistance to mechanical, electrical and chemical stresses. The practice with silicone insulators in polluted environments has shown that the ideal performance is directly related to insulator design and polymer formulation. One of the most common misunderstandings in the design of silicone compounds for insulators is the amount of inorganic load used in their formulation. This paper attempts to clarify how the variation of the inorganic load amount affects physicochemical characteristics of different silicone compounds. The physicochemical evaluation is performed from several measurements, such as: density, hardness, elongation, tensile strength. In addition, the evaluation of the physicochemical structure is carried out using infrared test and scanning electronic microscopy (SEM). The electrical analysis is performed from the electric tracking wheel and erosion test, in agreement with the recommendation of the International Electrotechnical Commission (IEC). (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Abstract. During the last decade mobile communications increasingly became part of people's daily routine. Such usage raises new challenges regarding devices' battery lifetime management when using most popular wireless access technologies, such as IEEE 802.11. This paper investigates the energy/delay trade-off of using an end-user driven power saving approach, when compared with the standard IEEE 802.11 power saving algorithms. The assessment was conducted in a real testbed using an Android mobile phone and high-precision energy measurement hardware. The results show clear energy benefits of employing user-driven power saving techniques, when compared with other standard approaches.
Resumo:
A high-power high-efficiency laser power transmission system at 100m based on an optimized multi-cell GaAs converter capable of supplying 9.7W of electricity is demonstrated. An I-V testing system integrated with a data acquisition circuit and an analysis software is designed to measure the efficiency and the I-V characteristics of the laser power converter (LPC). The dependencies of the converter’s efficiency with respect to wavelength, laser intensity and temperature are analyzed. A diode laser with 793nm of wavelength and 24W of power is used to test the LPC and the software. The maximum efficiency of the LPC is 48.4% at an input laser power of 8W at room temperature. When the input laser power is 24W (laser intensity of 60000W/m2), the efficiency is 40.4% and the output voltage is 4 V. The overall efficiency from electricity to electricity is 11.6%.
Resumo:
In this paper the power-frequency control of hydropower plants with long penstocks is addressed. In such configuration the effects of pressure waves cannot be neglected and therefore commonly used criteria for adjustment of PID governors would not be appropriate. A second-order Π model of the turbine-penstock based on a lumped parameter approach is considered. A correction factor is introduced in order to approximate the model frequency response to the continuous case in the frequency interval of interest. Using this model, several criteria are analysed for adjusting the PI governor of a hydropower plant operating in an isolated system. Practical criteria for adjusting the PI governor are given. The results are applied to a real case of a small island where the objective is to achieve a generation 100% renewable (wind and hydro). Frequency control is supposed to be provided exclusively by the hydropower plant. It is verified that the usual criterion for tuning the PI controller of isolated hydro plants gives poor results. However, with the new proposed adjustment, the time response is considerably improved
Resumo:
Este trabajo forma parte del proyecto “Health aware enhanced range wireless power transfer systems”, conocido por el acrónimo de ETHER. Los grupos investigadores que forman parte de ETHER involucran a dos instituciones, Universidad Politécnica de Cataluña (UPC) y Universidad Politécnica de Madrid (UPM). En este caso, el trabajo ha sido llevado a cabo en el marco del Centro de Electrónica Industrial(CEI) de la UPM. Además, este trabajo es el tercero en una sucesión de estudios realizados por el CEI con el objetivo de lograr implementar un sistema de carga inalámbrica en un marcapasos. Los trabajos previos al desarrollado son los realizados por Miguel Gifford y María Gonzalez. Otros trabajos del CEI han servido de guía. El principal objetivo de la aplicación, es evitar las operaciones que se llevan a cabo actualmente para la sustitución de la batería de los marcapasos implantados en pacientes. Este periodo de sustitución es del orden de cuatro años, lo que depende del tipo de marcapasos y las circunstancias en las que se vea envuelto el paciente. Se pretende lograr la carga del dispositivo causando la menor molestia posible al paciente sin afectar a su salud. El sistema de carga inalámrica o WPT1, está basado en inducción magnética resonante, conocida como RIC2. Esta tecnología se fundamenta en el uso de bobinas acopladas como elemento transmisor de energía. A su vez, la impedancia de estas bobinas, es compensada mediante el uso de condensadores, obteniendo circuitos resonantes. Mediante el uso de RIC se logran mejores características técnicas para la transmisión de energía en el rango medio. Esto permite salvar la distancia entre el elemento generador y la batería del marcapasos, incluso ante la existencia de tejido orgánico entre las dos bobinas. Se han considerado dos posibilidades de configuraci´on del sistema. Dos etapas: se dispone de dos bobinas, emisora y receptora. Esta configuración supone trabajar a altas frecuencias para conseguir transferencia de energías efectivas teniendo en cuenta las especificaciones del marcapasos. Tres etapas: se dispone de tres bobinas, emisora, intermedia y receptora. Se mejora el alcance, permitiendo trabajar a menores frecuencias, pero complicando el control y la implementación del sistema. Sin embargo, el foco de los esfuerzos invertidos en este trabajo, es el estudio del sistema de optimización que se introduce en las configuraciones anteriormente descritas. La optimización se centra en conseguir máxima transferencia de potencia, quedando relegado a un segundo plano el rendimiento. Esto se justifica por las características de la aplicación donde la principal limitación es la viabilidad del sistema. Asímismo, la viabilidad viene impuesta por la potencia que consume el marcapasos y la que es capaz de suministrar el sistema. Este sistema de optimización se basa en la regulación en frecuencia y en la adaptación de la impedancia de carga. Este último método es estudiado, y se basa en lograr una impedancia de carga igual al complejo conjugado de la impedancia de salida, logrando máxima transferencia de potencia. El sistema de optimización hace uso de varias estructuras de control de electrónica de potencia. Inversor: Se sitúa en la etapa emisora y permite controlar la frecuencia de trabajo del sistema. Rectificador activo: Se sitúa en la etapa receptora y controla el desfase entre intensidad y tensión. Convertidor CC-CC: Se sitúa en la etapa receptora, tras el rectificador. Controla la amplitud de la tensión.Mediante el uso conjunto del rectificador y el convertidor es posible controlar la impedancia de la carga. Se ha realizado un análisis teórico para determinar el punto de funcionamiento óptimo del sistema, y posteriormente, se han validado estos resultados mediante simulaciones. Se demuestra que la potencia transferida por el sistema WTP se multiplica por cinco respecto de la solución original, es decir, en ausencia del sistema de optimización. Además se logra mayor robustez, ya que el control activo del sistema proporciona mayor adaptabilidad ante condiciones alejadas de las de diseño. El trabajo realizado se ha prolongado durante un periodo de doscientos días efectivos con una dedicación de 360 horas de trabajo. El coste total asignado al desempeño del trabajo es de 16.678,94 euros.
Resumo:
Electromagnetic coupling phenomena between overhead power transmission lines and other nearby structures are inevitable, especially in densely populated areas. The undesired effects resulting from this proximity are manifold and range from the establishment of hazardous potentials to the outbreak of alternate current corrosion phenomena. The study of this class of problems is necessary for ensuring security in the vicinities of the interaction zone and also to preserve the integrity of the equipment and of the devices there present. However, the complete modeling of this type of application requires the three- -dimensional representation of the region of interest and needs specific numerical methods for field computation. In this work, the modeling of problems arising from the flow of electrical currents in the ground (the so-called conductive coupling) will be addressed with the finite element method. Those resulting from the time variation of the electromagnetic fields (the so-called inductive coupling) will be considered as well, and they will be treated with the generalized PEEC (Partial Element Equivalent Circuit) method. More specifically, a special boundary condition on the electric potential is proposed for truncating the computational domain in the finite element analysis of conductive coupling problems, and a complete PEEC formulation for modeling inductive coupling problems is presented. Test configurations of increasing complexities are considered for validating the foregoing approaches. These works aim to provide a contribution to the modeling of this class of problems, which tend to become common with the expansion of power grids.