948 resultados para potable water


Relevância:

70.00% 70.00%

Publicador:

Resumo:

El propósito de esta investigación fue el de hacer un análisis transversal de la política pública de acceso al agua en Colombia, desde la implementación, funcionamiento y efectividad de la misma, en el contexto del municipio de Río de Oro en el departamento del Cesar.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Australia is a water-stressed nation and demand on potable water supply is increasing. Consequently water conservation and reuse are increasingly becoming important. Irrigation of recycled wastewater on water repellent soils is a technology that is being trialled as a means of improving crop production and conserving potable supply. However, recycled water contains potentially harmful heavy metals. This paper reports the competitive sorption and desorption of several common heavy metals found in soils collected from a farm located in the south-east of South Australia. The soil from this location is severely water repellent, but some sites were amended with kaolinite clay (Si4Al4O10(OH)8) about 7 and 15 years ago. The metals studied were Cu, Pb, Cd, Cr, Ni, and Zn. Competitive sorption of the metals was distinctly observed. For all heavy metals, the quantity of metal sorbed was higher in amended soil, and there was a strong correlation between the specific sorption to total sorption ratio and the amount of clay in the soil. The sorption intensities varied with metal, Cr, Pb, and Cu having a high sorption tendencies and Zn, Cd, and Ni having comparatively low sorption tendencies. The total sorption capacity for all metals increased in clay-treated soils compared with non-treated soils. On average, clay-amended water repellent soils had a 20–40% increased capacity to adsorb total metals; however, this increase was largely caused by the increased capacities to adsorb Zn, Cd, and Ni. The effect of clay treatment largely enhanced the sorption capacity of relatively weakly adsorbing heavy metals. The implications for using recycled wastewater on the long-term sustainable agro-environmental management of these soils are discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The thesis concluded that unless a 40% potable water reduction target and water sensitive urban design objectives for infill residential development were mandated, the study from the municipality of Darebin showed that Melbourne could not become a water sensitive city.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

New technologies are required to improve desalination efficiency and increase water treatment capacities. One promising low energy technique to produce potable water from either sea or sewage water is membrane distillation (MD). However, to be competitive with other desalination processes, membranes need to be designed specifically for the MD process requirements. Here we report on the design of carbon nanotube (CNT) based composite material membranes for direct contact membrane distillation (DCMD). The membranes were characterized and tested in a DCMD setup under different feed temperatures and test conditions. The composite CNT structures showed significantly improved performance compared to their pure self-supporting CNT counterparts. The best composite CNT membranes gave permeabilities as high as 3.3 x 10-12 kg/(m x s x Pa) with an average salt rejection of 95% and lifespan of up to 39 h of continuous testing, making them highly promising candidates for DCMD.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The United Arab Emirates (UAE) face a serious water problem. It has a very dry climate, high evaporation rate, combined with large water consumption from fast growing population, economic activities and uncontrolled uses of water for irrigation. Currently, UAE has one of the largest water footprints in the world. Groundwater is overexploited. Waste water is increasingly being treated to supply non-drinking water, but it still cover a small proportion of the demand. Desalination of sea water is the main source of potable water in UAE, but the high economic cost of desalination, its intensive energy demand and the adverse effects of its effluents on the marine life are a major concern. Other factors contributing to the problem are the focus of water management policies on keep supplying the growing demand for water, the increase of the per capita water consumption, and the free water charge for most of population. This research goal is to develop a water sustainability set of indicators for the challenging context of UAE. This paper presents the first stage of the research. Based on a review of the literature, the proposed framework involves 19 indicators, divided into four categories: water availability; water quality; water use efficiency; and policy and governance. Using an integrated cause-effect approach (DSR - Driving force, State, Response), the indicators were related in terms of their interdependencies, with a holistic view of the city water cycle. A preliminary test of the indicators to Abu Dhabi as a case study allowed an evaluation of the main 'Driving force' on the system, such as the scarcity of water due to natural constraints of the region, and increasing water consumption patterns of modern society; an assessment of the current 'state', which is under serious water stress. Also it indicated some potential 'responses', such as implementing policies for increasing efficient use.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper details a system dynamics model developed to simulate proposed changes to water governance through the integration of supply, demand and asset management processes. To effectively accomplish this, interconnected feedback loops in tariff structures, demand levels and financing capacity are included in the model design, representing the first comprehensive life-cycle modelling of potable water systems. A number of scenarios were applied to Australia's populated South-east Queensland region, demonstrating that introducing temporary drought pricing (i.e. progressive water prices set inverse with availability), in conjunction with supply augmentation through rain-independent sources, is capable of efficiently providing water security in the future. Modelling demonstrated that this alternative tariff structure reduced demand in scarcity periods thereby preserving supply, whilst revenues are maintained to build new water supply infrastructure. In addition to exploring alternative tariffs, the potential benefits of using adaptive pressure-retarded osmosis desalination plants for both potable water and power generation was explored. This operation of these plants for power production, when they would otherwise be idle, shows promise in reducing their net energy and carbon footprints. Stakeholders in industry, government and academia were engaged in model development and validation. The constructed model displays how water resource systems can be reorganised to cope with systemic change and uncertainty.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The project is being conducted in the town of Analândia, São Paulo, Brazil. The constructed wetlands system for water supply consists of a channel with floating aquatic macrophytes, HDS system (Water Decontamination with Soil - Patent PI 850.3030), chlorinating system, filtering system and distribution. The project objectives include investigating the process variables to further optimize design and operation factors, evaluating the relation of nutrients and plants development, biomass production, shoot development, nutrient cycling and total and fecal coliforms removal, comparing the treatment efficiency among the seasons of the year; and moreover to compare the average values obtained between February and June 1998 (Salati et al., 1998) with the average obtained for the same parameters between March and June 2000. Studies have been developed in order to verify during one year the drinking quality of the water for the following parameters: turbidity, color, pH, dissolved oxygen, total of dissolved solids, COD, chloride, among others, according to the Ministry of Health's Regulation 36. This system of water supply projected to treat 15 L s-1 has been in continuous operation for 2 years, it was implemented with support of the National Environment Fund (FNMA), administered by the Center of Environmental Studies (CEA-UNESP), while the technical supervision and design were performed by the Institute of Applied Ecology. The actual research project is being supported by FAPESP.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Leakage in buried pipes is one of the main concerns for water companies due to the scarcity of potable water sources. Older metallic pipelines have been replaced by plastic pipes in such systems, which makes it more difficult to locate leaks using acoustics and vibration. This is mainly because of the high attenuation of leak signals caused by the damping in the pipe wall. To investigate acoustic methods in leak location in controlled conditions, a bespoke test rig was constructed in the UK. In this paper, data from this test-rig is used to discuss some issues that arise when using two contemporary correlators. Of particular interest, is the way in which a resonance in the system can have a profound effect on the estimate of the position of the leak depending on the way in which the leak noise signals are processed. © (2013) Trans Tech Publications.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Editorial remarks.-- Open discussion: Conceptual change in regulation in a model of public service provision ; Policies and institutional frameworks for drinking water supply and sanitation ; Strategies for low-carbon development in megacities in Latin America ; Adapting to climate change in water management in the irrigation sector.-- Meetings: Towards a vision on natural resource governance for equality ; Water resources faced with uncertainty and the risk of climate change ; Regulation challenges in the water sector.-- News of the Network: Lessons to be drawn from the interprovincial Colorado River flow distribution agreement ; Rural drinking water programme in Chile ; Ecuador’s Act on Water Resources and Water Use and Exploitation.-- Internet and WWW News

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Editorial remarks.-- Open discussion: Regulation under the public model of service provision ; Regulatory progress and challenges in Argentina ; Twenty years of SUNASS: development, experience, lessons learned and challenges ; Possible conflict between efficiency and sustainability ; Best practices in regulating State-owned and municipal water utilities.-- News of the Network: Water use charge in the Province of Buenos Aires ; National Drinking Water and Sanitation Sector Policy of Guatemala ; Sanitation Services Modernization Law of Peru ; Internet and WWW News

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Protecting ground water from pollution in the rural areas of Ukraine is a priority, particularly because the largely unconfined aquifers are used by local people for potable water supply. The most important aim of this project was to characterise the scale and impact of pollution sources on groundwater quality according to the nature of groundwater vulnerability and of the particular sources of pollution. Analysis of 50 different maps of Ukraine according to geochemical, natural and landscape features, together with field studies made it possible to identify areas with different pollution risk factors. The most harmful sources of groundwater contamination providing nitrates, petrol, heavy metals and other pollutants were identified and an integral method of groundwater quality assessment was worked out. The main sources of groundwater contamination in rural areas of Ukraine were identified and listed in order of importance. Magmedov also puts forward recommendations for improving monitoring of groundwater quality as an essential part of sustainable development in rural areas of Ukraine.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In developing countries many water distribution systems are branched networks with little redundancy. If any component in the distribution system fails, many users are left relying on secondary water sources. These sources oftentimes do not provide potable water and prolonged use leads to increased cases of water borne illnesses. Increasing redundancy in branched networks increases the reliability of the networks, but is oftentimes viewed as unaffordable. This paper presents a procedure for water system managers to use to determine which loops when added to a branch network provide the most benefit for users. Two methods are presented, one ranking the loops based on total number of users benefited, and one ranking the loops of number of vulnerable users benefited. A case study is presented using the water distribution system of Medina Bank Village, Belize. It was found that forming loops in upstream pipes connected to the main line had the potential to benefit the most users.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Despite failed attempts at obtaining a potable water system, the village of El Caracol in Southern Honduras remains committed to improving access to water resources. To assist in this endeavor, an investigation of the hydrogeological characteristics of the local watershed was conducted. Daily precipitation was recorded to examine the relationship between precipitation and approximated river and spring discharges. A Thornthwaite Mather Water Balance Model was used to predict monthly discharges for comparison with observed values, and to infer the percentage of topographic watersheds contributing to the respective discharges. As aquifer porosity in this region is thought to be primarily secondary (i.e., fractures), field observed lineaments were compared with those interpreted from remote sensing imagery in an attempt to determine the usefulness of these interpretations in locating potential water sources for a future project.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this work was to evaluate different management strategies to optimize rabbit production under chronic heat stress. To achieve it, three trials were conducted. In the first trial, to find the optimal cage density in tropical very dry forest condition, were measured growth performance, mortality rate, injured animals and carcass performance over an initial population of 300 cross-breed rabbits of New Zealand, California, Butterfly, Dutch and Satin, weaned at 30 days (535 ± 8 g, standard error). Treatments evaluated were: 6, 12, 18 and 24 rabbits/m2 (3, 6, 9 and 12 rabbits/cage, respectively, each cage of 0.5 m2). The maximal temperature-humidity index indicated a severe heat stress from weaning to 2.2 kg body weight (experimental time). At the end of experimental period 10, 20, 30 and 30 rabbits from the treatments of 6, 12, 18 and 24 rabbits/m2, respectively, were slaughtered and carcass performance recorded. Average daily gain and feed intake decreased by 0.31 ± 0.070 and 1.20 ± 0.25 g, respectively, per each unit that the density increased at the beginning of the experiment (P = 0.001). It increased the length of the fattening period by 0.91 ± 0.16 d (P = 0.001) per each unit of increment of density. However, rabbit production (kg/m2) increased linear and quadratically with the density (P < 0.008). Animals housed at the highest density compared to the lower one tended to show a higher incidence of ringworm (68.9 vs 39.4%; P = 0.075), injured animals (16.8 vs 3.03%; P = 0.12) and mortality (20.5 vs 9.63%; P = 0.043). The proportion of scapular fat (P = 0.042) increased linearly with increasing levels of density. Increasing density reduced linearly dorsal length (P = 0.001), and reduced linear and quadratically drip loss percentage (P = 0.097 and 0.018, respectively). In the second trial, 46 nulliparous rabbit does (23 clipped and 23 unclipped) with a BW of 3.67 ± 0.05 kg (s.e.) were used to evaluate heat stress and circadian rhythms comparing unclipped and clipped rabbit does, and to study if a more extensive breeding system increase litters performance at weaning without impairing rabbit doe performance,. Rectal temperature, feed and water 4 intake were recorded for 24 h. Rabbit does were mated 7 d after circadian measurements, and randomly assigned to two breeding systems. Control (C): mated at 14 d after parturition + litter weaned at 35 d of age. Extensive (E): mate at 21 after parturition + litter weaned at 42 d of age. The first three cycles were evaluated concerning to rabbit doe and litter performance. Two hundred twenty eight weaned rabbits, were divided into two cage sizes: 0.5 and 0.25 m2 with same density (16 rabbit/m2) and growing performance was recorded. Farm and rectal temperatures were minimal and feed and water intake maximal during the night (P < 0.001). Unclipped rabbit does showed higher rectal temperature (P = 0.045) and lower feed intake respect to clipped does (P = 0.019) which suggest a lower heat stress in the latter. Kits weaned per litter was reduced by 33% (P=0.038) in C group. This reduction was more important in the 2nd and 3rd cycles compared to the first (P ≤ 0.054). Rabbit doe feed efficiency tended to decrease in E respect C group (P = 0.093), whereas it was impaired from the first to the third cycle by 48% (P = 0.014). Growing rabbits from the E group were heavier at weaning (by 38%. P < 0.001), showed a higher feed intake (+7.4%) and lower feed efficiency (-8.4%) throughout the fattening period (P ≤ 0.056) respect to C group. Cage size had minor influence in growing performance. In the third trial, forty five non pregnant and non lactating rabbit does (21 nulliparous and 24 multiparous) were assigned randomly to farm water and to potable water to study if a water quality improvement can affect positively rabbit doe response to heat stress during pregnancy and lactation. A transponder was implanted in each animal to record subcutaneous temperature at 07:30 and 14:30 h. Experimental period extended from pregnancy (with no lactation) to the next lactation (until day 28). Body temperature and milk production were recorded daily, and body condition, feed and water intake weekly. Water quality did not affect any trait (P ≥ 0.15). Pregnant rabbit does were classified as does that weaned (W: 47%), not weaned (NW: 44%) or those pregnant that did not deliver (NB: 9%). Body temperature and feed intake decreased during pregnancy (P ≤ 0.031), but water intake remained constant. In this period body temperature decreased with metabolic weight (P ≤ 0.009). In W and NW does, 5 from mating to birth energy and protein balance impaired (P≤0.011). Body temperature of W does tended to be the lowest (P ≤ 0.090). Pregnancy length and total number of kits born tended to be longer and higher in NW than in W does (P = 0.10 and 0.053, respectively). Kit mortality at birth and from birth to 14 d of lactation was high, being worse for NW than for W does (97 vs. 40%; P<0.001). Body temperature during lactation was maximal at day 12, and milk production increased it (P ≤ 0.025). . In conclusion, in our heat stress conditions densities higher than 18 rabbits/m2 (34 kg/m2) at the end of fattening, are not recommended despite cage size, gestation and lactation productivity impaired not only when lactation is extended and along successive reproductive cycles but also due to a reduced embryo/kit survival and finally water quality improvement did not attenuate negative effect of heat stress. RESUMEN El propósito de éste trabajo fue evaluar diferentes estrategias de manejo para optimizar la producción de conejos bajo estrés térmico. Para lo cual se desarrollaron tres experimentos. En el primer experimento, para encontrar el número óptimo de gazapos por m2 de jaula durante el cebo en condiciones de bosque muy seco tropical, se estudiaron los rendimientos durante el cebo, mortalidad, animales lesionados y rendimiento de la canal sobre una población inicial de 300 conejos mestizos de Nueva Zelanda, California, Mariposa, Holandés y Satin, destetados a los 30 días de edad (535 ± 8g, error estándar). Los tratamientos evaluados fueron: 6, 12, 18 y 24 conejos/m2 (3, 6, 9 y 12 conejos/jaula, respectivamente, en jaulas de 0.5 m2). Durante el período experimental (destete a 2.2 kg de peso vivo), se observaron valores de THI correspondientes con un estrés térmico severo (THI max. De 31 a 35). Al final del período experimental, 10, 20, 30, y 30 conejos de los tratamientos con densidades de 6, 12, 18 y 24 conejos/m2, respectivamente, fueron sacrificados y su canal fue valorada. El promedio de la ganancia diaria y el consumo de alimento disminuyeron en 0.31 ± 0.070 y 1.20 ± 0.25 g, respectivamente, por cada unidad de incremento en la densidad al inicio del experimento (P=0.001). Esto alargó el período de engorde en 0.91 ± 0.16 d (P=0.001) por cada unidad de incremento de la densidad. Sin embargo, la producción de conejos (kg/m2) aumentó lineal y cuadráticamente con la densidad (P<0.008). Los animales alojados en las mayores densidades en comparación con el resto tendieron a mostrar una mayore incidencia de tiña (68.9 vs 39.4%; P=0.075), de cantidad de animales heridos (16.8 vs 3.03%; P=0.12), así como de mortalidad (20.5 vs 9.63%; P=0.043). El aumento en la densidad aumentó linealmente la proporción de grasa escapular (P=0.042) y redujo linealmente la longitud dorsal (P=0.001), y lineal y cuadráticamente el porcentaje de pérdida por goteo (P=0.018). En el segundo experimento, 46 conejas nulliparas (23 rasuradas y 23 no rasuradas) con un peso vivo de 3.67 ± 0.05 kg (e.e.) fueron usadas para evaluar el estrés 8 térmico y los ritmos circadianos comparando conejas rasuradas o no, y estudiar si un sistema de crianza más extensivo mejora el desempeño de la camada al destete sin perjudicar la productividad de la coneja. Durante 24 h se midió la temperatura rectal, consumo de alimento y de agua. Las conejas fueron montadas 7 días después, y distribuidas en dos sistemas de crianza. El control (C): monta a 14 días posparto y destete a 35 d de edad. El extensivo (E): monta a 21 días posparto y destete a 42 d de edad. Se controló la productividad de la coneja y la camada durante los tres primeros ciclos. Doscientos veintiocho gazapos fueron distribuidos en dos tamaños de jaulas (0.5 y 0.25 m2) con la misma densidad (16 conejos/m2) y se controlaron sus rendimientos productivos. Durante la noche se observaron los valores mínimos para la temperatura ambiental y rectal, y los máximos para consumo de alimento y agua (P< 0.001). Las conejas no rasuradas mostraron mayor temperatura rectal (P=0.045) y menores valores de consumo de alimento con respecto a las conejas rasuradas (P=0.019), lo que sugiere un menor estrés térmico en las últimas. El número de gazapos destetados por camada se redujo en 33% (P=0.038) en el grupo C. Este comportamiento se acentuó en el 2do y 3er ciclo en comparación con el primero (P≤0.054). La eficiencia alimenticia de las conejas tendió a disminuir en el grupo E con respecto al grupo C (P=0.093), dicha tendencia se acentúa del primer al tercer ciclo en un 48% (P=0.014). Los gazapos en fase de crecimiento provenientes del grupo E fueron más pesados al momento del destete (en 38% P<0.001), mostrando un mayor consumo de alimento (+7.4%) y menor eficiencia alimenticia (-8.4%) a lo largo del engorde (P≤0.056) con respecto al grupo C. El tamaño de la jaula tuvo una mínima influencia en el comportamiento durante el crecimiento de éstos gazapos. En el tercer experimento, cuarenta y cinco conejas no gestantes ni lactantes (21 nulíparas y 24 multíparas) se les asignó al azar agua dos tipos de agua: común de la granja y agua potable, con el fin de estudiar si una mejora en la calidad del agua puede afectar positivamente la respuesta de la coneja al estrés térmico durante la gestación y la lactancia. Se les implantó un transponder para registrar la temperatura subcutánea a las 7:30 y a las 14:30 h. El período experimental se extendió desde la gestación (sin 9 lactancia) hasta la lactanción consecutiva (hasta los 28 días). La temperatura corporal y la producción de leche se controlaron diariamente, y la condición corporal, consumo de agua y alimento, semanalmente. La calidad del agua no afectó a ninguna variable (P≥0.15). Las conejas preñadas fueron clasificadas como conejas que destetaron (W: 47%), que no destetaron (NW:44%) o aquellas que no parieron (NB: 9%). La temperatura corporal y consumo de alimento disminuyeron durante la gestación (P≤0.031), mientras que el consumo de agua se mantuvo constante. La temperatura corporal descendió con el peso metabólico durante la gestación (P≤0.009). El balance de energía y proteína disminuyó desde la monta al parto para las conejas W y NW (P≤0.011). Durante la gestación la temperatura corporal tendió a ser menor en las conejas W (P≤0.090). La longitud de la gestación y el número total de gazapos nacidos tendieron a ser mayores en conejas NW que en conejas W (P=0.10 y 0.053, respectivamente). La mortalidad de los gazapos al parto y del parto a los 14 días de lactancia fue alta, siendo peor para las conejas NW que para las W (97 vs 40%; P<0.001). Durante la lactancia la temperatura corporal alcanzó su valor máximo para el día 12, y la producción de leche indujo un incremento en la misma (P≤0.025). En conclusión, en nuestras condiciones de estrés térmico y sin importar el tamaño de la jaula, no se recomiendan densidades mayores a 18 conejos/m2 (34 kg/m2) al final del engorde. La productividad de la gestación y la lactancia disminuyen cuando la lactancia es mayor y se suceden varios ciclos reproductivos seguidos. Esto se debe al efecto negativo del estrés térmico sobre la vitalidad y supervivencia del embrión/gazapo. La mejora de la calidad del agua atenuó el efecto negativo del estrés térmico. Las conejas más productoras parece que son aquéllas que consiguen manejar mejor el estrés térmico.