975 resultados para performance variable


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work addresses the effects of catalyst deactivation and investigates methods to reduce their impact on the reactive distillation columns performance. The use of variable feed quality and reboil ratio are investigated using a rigorous dynamic model developed in gPROMS and applied to an illustrative example, i.e., the olefin metathesis system, wherein 2-pentene reacts to form 2-butene and 3-hexene. Three designs and different strategies on column energy supply to tackle catalyst deactivation are investigated and the results compared.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As wind power generation undergoes rapid growth, new technical challenges emerge: dynamic stability and power quality. The influence of wind speed disturbances and a pitch control malfunction on the quality of the energy injected into the electric grid is studied for variable-speed wind turbines with different power-electronic converter topologies. Additionally, a new control strategy is proposed for the variable-speed operation of wind turbines with permanent magnet synchronous generators. The performance of disturbance attenuation and system robustness is ascertained. Simulation results are presented and conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the performance of the rubella suspect case definition among patients with rash diseases seen at primary care units. METHODS: From January 1994 to December 2002, patients with acute rash, with or without fever, were seen at two large primary health care units and at a public general hospital in the municipality of Niterói, metropolitan area of Rio de Janeiro, Brazil. Data from clinical and serologic assessment were used to estimate the positive predictive values of the definition of rubella suspect case from the Brazilian Ministry of Health and other combination of signs/symptoms taking serologic status as the reference. Serum samples were tested for anti-rubella virus IgM using commercially available enzyme immunoassays. Positive predictive values and respective 95% confidence intervals were calculated. RESULTS: A total of 1,186 patients with an illness characterized by variable combinations of rash with fever, arthropathy and lymphadenopathy were studied. Patients with rash, regardless of other signs and symptoms, had 8.8% likelihood of being IgM-positive for rubella. The Brazilian suspect case definition (fever and lymphadenopathy in addition to rash) had low predictive value (13.5%). This case definition would correctly identify 42.3% of the IgM-positive cases, and misclassify 26.1% of the IgM-negative cases. CONCLUSIONS: These results support the recommendation to investigate and collect clinical specimens for laboratory diagnosis of all cases of rash, for surveillance purposes. Although this strategy may increase costs, the benefits of interrupting the circulation of rubella virus and preventing the occurrence of congenital rubella syndrome should pay off.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de Mestrado, Ciências Económicas e Empresariais, 17 de Junho de 2015, Universidade dos Açores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies fractional variable structure controllers. Two cases are considered namely, the sliding reference model and the control action, that are generalized from integer into fractional orders. The test bed consists in a mechanical manipulator and the effect of the fractional approach upon the system performance is evaluated. The results show that fractional dynamics, both in the switching surface and the control law are important design algorithms in variable structure controllers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To assess the impact of implementing long-stay beds for patients of low complexity and high dependency in small hospitals on the performance of an emergency referral tertiary hospital. METHODS For this longitudinal study, we identified hospitals in three municipalities of a regional department of health covered by tertiary care that supplied 10 long-stay beds each. Patients were transferred to hospitals in those municipalities based on a specific protocol. The outcome of transferred patients was obtained by daily monitoring. Confounding factors were adjusted by Cox logistic and semiparametric regression. RESULTS Between September 1, 2013 and September 30, 2014, 97 patients were transferred, 72.1% male, with a mean age of 60.5 years (SD = 1.9), for which 108 transfers were performed. Of these patients, 41.7% died, 33.3% were discharged, 15.7% returned to tertiary care, and only 9.3% tertiary remained hospitalized until the end of the analysis period. We estimated the Charlson comorbidity index – 0 (n = 28 [25.9%]), 1 (n = 31 [56.5%]) and ≥ 2 (n = 19 [17.5%]) – the only variable that increased the chance of death or return to the tertiary hospital (Odds Ratio = 2.4; 95%CI 1.3;4.4). The length of stay in long-stay beds was 4,253 patient days, which would represent 607 patients at the tertiary hospital, considering the average hospital stay of seven days. The tertiary hospital increased the number of patients treated in 50.0% for Intensive Care, 66.0% for Neurology and 9.3% in total. Patients stayed in long-stay beds mainly in the first 30 (50.0%) and 60 (75.0%) days. CONCLUSIONS Implementing long-stay beds increased the number of patients treated in tertiary care, both in general and in system bottleneck areas such as Neurology and Intensive Care. The Charlson index of comorbidity is associated with the chance of patient death or return to tertiary care, even when adjusted for possible confounding factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper deals with a hierarchical structure composed by an event-based supervisor in a higher level and two distinct proportional integral (PI) controllers in a lower level. The controllers are applied to a variable speed wind energy conversion system with doubly-fed induction generator, namely, the fuzzy PI control and the fractional-order PI control. The event-based supervisor analyses the operation state of the wind energy conversion system among four possible operational states: park, start-up, generating or brake and sends the operation state to the controllers in the lower level. In start-up state, the controllers only act on electric torque while pitch angle is equal to zero. In generating state, the controllers must act on the pitch angle of the blades in order to maintain the electric power around the nominal value, thus ensuring that the safety conditions required for integration in the electric grid are met. Comparisons between fuzzy PI and fractional-order PI pitch controllers applied to a wind turbine benchmark model are given and simulation results by Matlab/Simulink are shown. From the results regarding the closed loop point of view, fuzzy PI controller allows a smoother response at the expense of larger number of variations of the pitch angle, implying frequent switches between operational states. On the other hand fractional-order PI controller allows an oscillatory response with less control effort, reducing switches between operational states. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the implementation of a distributed model predictive approach for automatic generation control. Performance results are discussed by comparing classical techniques (based on integral control) with model predictive control solutions (centralized and distributed) for different operational scenarios with two interconnected networks. These scenarios include variable load levels (ranging from a small to a large unbalance generated power to power consumption ratio) and simultaneously variable distance between the interconnected networks systems. For the two networks the paper also examines the impact of load variation in an island context (a network isolated from each other).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Life-Cycle Civil Engineering – Biondini & Frangopol

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The cyclic load triaxial test is a laboratory test that allows studying the mechanical behaviour of unbound granular materials used in base/subbase layers of road pavements. The resilient modulus and permanent strains are required as inputs in structural pavement design. This paper presents some results obtained for recycled materials (crushed concrete aggregate and blended crushed waste aggregate), with a view to promoting their use in pavement structures. Results relating to a reference material (limestone) are also presented, for comparison. All the test results discussed in this paper were obtained in variable cyclic radial pressure (VCP) tests. The tests performed (VCP) aim to study the influence of water content on the resilient modulus of recycled materials, as well as on the resistance to permanent deformation. Using the experimental data as a basis, further modelling work was carried out to establish the stresses developing in base/capping layers in typical Belgian road pavements. These numerical results allow to propose some simplifications of the stress paths applied in the testing procedures and to establish a new test protocol that also considers compaction during construction works. The results of this research work provide an excellent set of findings for the mechanical characterization of unbound base materials through the cyclic triaxial test, and contribute to a better understanding and correct application of recycled materials under geotechnical engineering background

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to predict time series of SO2 concentrations emitted by coal-fired power stations in order to estimate in advance emission episodes and analyze the influence of some meteorological variables in the prediction. An emission episode is said to occur when the series of bi-hourly means of SO2 is greater than a specific level. For coal-fired power stations it is essential to predict emission epi- sodes sufficiently in advance so appropriate preventive measures can be taken. We proposed a meth- odology to predict SO2 emission episodes based on using an additive model and an algorithm for variable selection. The methodology was applied to the estimation of SO2 emissions registered in sampling lo- cations near a coal-fired power station located in Northern Spain. The results obtained indicate a good performance of the model considering only two terms of the time series and that the inclusion of the meteorological variables in the model is not significant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El objetivo de este trabajo consiste en proponer una medida de performance adecuada para los fondos de inversión de renta variable. Las características específicas de este tipo de carteras inducen a tomar un enfoque basado en la L.M.C., por lo que se escoge como medida de riesgo el riesgo total de la cartera (pσ). Se introducen las estrategias pasivas y activas en el análisis, con lo que se consigue desarrollar una medida de performance que, además de medir la rentabilidad por gestión efectiva, la pondera en función del grado de actividad asumido por la cartera a evaluar.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Manual dexterity, a prerogative of primates, is under the control of the corticospinal (CS) tract. Because 90-95% of CS axons decussate, it is assumed that this control is exerted essentially on the contralateral hand. Consistently, unilateral lesion of the hand representation in the motor cortex is followed by a complete loss of dexterity of the contralesional hand. During the months following lesion, spontaneous recovery of manual dexterity takes place to a highly variable extent across subjects, although largely incomplete. In the present study, we tested the hypothesis that after a significant postlesion period, manual performance in the ipsilesional hand is correlated with the extent of functional recovery in the contralesional hand. To this aim, ten adult macaque monkeys were subjected to permanent unilateral motor cortex lesion. Monkeys' manual performance was assessed for each hand during several months postlesion, using our standard behavioral test (modified Brinkman board task) that provides a quantitative measure of reach and grasp ability. The ipsilesional hand's performance was found to be significantly enhanced over the long term (100-300 days postlesion) in six of ten monkeys, with the six exhibiting the best, though incomplete, recovery of the contralesional hand. There was a statistically significant correlation (r = 0.932; P < 0.001) between performance in the ipsilesional hand after significant postlesion period and the extent of recovery of the contralesional hand. This observation is interpreted in terms of different possible mechanisms of recovery, dependent on the recruitment of motor areas in the lesioned and/or intact hemispheres.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the B-ISDN there is a provision for four classes of services, all of them supported by a single transport network (the ATM network). Three of these services, the connected oriented (CO) ones, permit connection access control (CAC) but the fourth, the connectionless oriented (CLO) one, does not. Therefore, when CLO service and CO services have to share the same ATM link, a conflict may arise. This is because a bandwidth allocation to obtain maximum statistical gain can damage the contracted ATM quality of service (QOS); and vice versa, in order to guarantee the contracted QOS, the statistical gain have to be sacrificed. The paper presents a performance evaluation study of the influence of the CLO service on a CO service (a circuit emulation service or a variable bit-rate service) when sharing the same link