981 resultados para percutaneous occlusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider brightness/contrast-invariant and rotation-discriminating template matching that searches an image to analyze A for a query image Q We propose to use the complex coefficients of the discrete Fourier transform of the radial projections to compute new rotation-invariant local features. These coefficients can be efficiently obtained via FFT. We classify templates in ""stable"" and ""unstable"" ones and argue that any local feature-based template matching may fail to find unstable templates. We extract several stable sub-templates of Q and find them in A by comparing the features. The matchings of the sub-templates are combined using the Hough transform. As the features of A are computed only once, the algorithm can find quickly many different sub-templates in A, and it is Suitable for finding many query images in A, multi-scale searching and partial occlusion-robust template matching. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was intended to examine the in vitro penetration of cisplatin (CIS) through porcine skin in the presence of different concentrations of monoolein (MO) as well as to verify the main barrier for CIS skin penetration. In vitro skin penetration of CIS was studied from propylene glycol (PG) solutions containing 0%, 5%, 10%, and 20% of MO using Franz-type diffusion cell and porcine ear skin. Pretreatment experiments with MO and experiments with skin without stratum corneum (SC) were also carried out. Skin penetration studies of CIS showed that the presence of MO doubled the drug permeation through the intact skin. However, permeation studies through the skin without SC caused only a small enhancement of CIS permeation compared to intact skin. Moreover, pretreatment of skin with MO formulations did not show any significant increase in the flux of the drug. In conclusion, MO did not act as a real penetration enhancer for CIS, but it increased the drug partition to the receptor solution improving CIS transdermal permeation. The absence of improvement in drug permeation by MO pretreatment and by the removal of SC indicates that the SC is not the main barrier for the permeation of the metal coordination compound. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of mathematical models have been used to describe percutaneous absorption kinetics. In general, most of these models have used either diffusion-based or compartmental equations. The object of any mathematical model is to a) be able to represent the processes associated with absorption accurately, b) be able to describe/summarize experimental data with parametric equations or moments, and c) predict kinetics under varying conditions. However, in describing the processes involved, some developed models often suffer from being of too complex a form to be practically useful. In this chapter, we attempt to approach the issue of mathematical modeling in percutaneous absorption from four perspectives. These are to a) describe simple practical models, b) provide an overview of the more complex models, c) summarize some of the more important/useful models used to date, and d) examine sonic practical applications of the models. The range of processes involved in percutaneous absorption and considered in developing the mathematical models in this chapter is shown in Fig. 1. We initially address in vitro skin diffusion models and consider a) constant donor concentration and receptor conditions, b) the corresponding flux, donor, skin, and receptor amount-time profiles for solutions, and c) amount- and flux-time profiles when the donor phase is removed. More complex issues, such as finite-volume donor phase, finite-volume receptor phase, the presence of an efflux. rate constant at the membrane-receptor interphase, and two-layer diffusion, are then considered. We then look at specific models and issues concerned with a) release from topical products, b) use of compartmental models as alternatives to diffusion models, c) concentration-dependent absorption, d) modeling of skin metabolism, e) role of solute-skin-vehicle interactions, f) effects of vehicle loss, a) shunt transport, and h) in vivo diffusion, compartmental, physiological, and deconvolution models. We conclude by examining topics such as a) deep tissue penetration, b) pharmacodynamics, c) iontophoresis, d) sonophoresis, and e) pitfalls in modeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perceived slant was measured for horizontal lines aligned on one side and of varying lengths whose length disparity was either a constant linear amount for all lines (consistent with uniocular occlusion) or proportional to line length (consistent with global slant). Although the disparity of any line was ambiguous with respect to these two possibilities, slant of individual lines did not occur in the former case, but a subjective contour in depth was reported along the alignment. For proportional disparity of the set, global slant was seen. Adding a constant length to each line on the invalid eye for occlusion resulted in multiple slants. Smooth uniocular variations in alignment shape elicited subjective contours slanting or curving in depth. Global context can disambiguate the depth status of individual disparate lines. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A partially occluded contour and a slanted contour may generate identical binocular horizontal disparities. We investigated conditions promoting an occlusion resolution indicated by an illusory contour in depth along the aligned ends of horizontally disparate line sets. For a set of identical oblique lines with a constant width added to one eye's view, strength, depth, and stability of the illusory contour were poor, whereas for oblique lines of alternating orientations the illusory contours were strong, indicating a reliance on vertical size disparities rather than vertical positional disparities in generating perceived occlusion. For horizontal lines, occlusion was seen when the lines were of different lengths and absolute width disparity was invariant across the set. In all line configurations, when the additional length was on the wrong eye to be attributed to differential occlusion, lines appeared slanted consistent with their individual horizontal disparities. This rules out monocular illusory contours as the determining factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of this study was to describe the preliminary results of prophylactic temporary balloon occlusion of the internal iliac arteries for bleeding control in patients with placenta accreta during cesarean hysterectomy. Methods From May 2006 to March 2010, 21 patients diagnosed with placenta accreta using ultrasound and/or magnetic resonance imaging were submitted to prophylactic balloon occlusion before hysterectomy. Fluoroscopy, balloon occlusion time, surgical duration, intraoperative blood loss, transfusion volume, and procedure complications were analyzed. Results The mean age was 30.5 years with a mean of 3.6 previous gestations. Imaging studies revealed that all patients had placenta accreta and all were submitted to cesarean hysterectomy. One hysterectomy was due to previous diagnosis of fetal death and another due to cesarean with uterine curettage. Mean fluoroscopy time was 7.5 min, balloon occlusion time was 164 min, and surgery duration was 260 min. Estimated blood loss was 1,671.5 ml with mean reposition fluids of 3,538 ml of crystalloids, 309.5 ml of colloids, and 1.24 ml of packed red blood cells. Two patients were submitted to thromboembolectomy due to prolonged surgical time. There was no maternal or fetal mortality related to the procedure. Conclusions The results demonstrated that prophylactic balloon occlusion of internal iliac artery is a safe method and appears to reduce blood loss and transfusion requirements in patients diagnosed with placenta accreta who undergo cesarean hysterectomy. Antenatal imaging diagnosis of placenta accreta enables preoperative planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proteinuria was associated with cardiovascular events and mortality in community-based cohorts. The association of proteinuria with mortality and cardiovascular events in patients undergoing percutaneous coronary intervention (PCI) was unknown. The association of urinary dipstick proteinuria with mortality and cardiovascular events (composite of death, myocardial infarction, or nonhemorrhagic stroke) in 5,835 subjects of the EXCITE trial was evaluated. Dipstick urinalysis was performed before PCI, and proteinuria was defined as trace or greater. Subjects were followed up for 210 days/7 months after enrollment for the occurrence of events. Multivariate Cox regression analysis evaluated the independent association of proteinuria with each outcome. Mean age was 59 years, 21% were women, 18% had diabetes mellitus, and mean estimated glomerular filtration rate was 90 ml/min/1.73 m(2). Proteinuria was present in 750 patients (13%). During follow-up, 22 subjects (2.9%) with proteinuria and 54 subjects (1.1%) without proteinuria died (adjusted hazard ratio 2.83, 95% confidence interval [CI] 1.65 to 4.84, p <0.001). The severity of proteinuria attenuated the strength of the association with mortality after PCI (low-grade proteinuria, hazard ratio 2.67, 95% CI 1.50 to 4.75; high-grade proteinuria, hazard ratio 3.76, 95% CI 1.24 to 11.37). No significant association was present for cardiovascular events during the relatively short follow-up, but high-grade proteinuria tended toward increased risk of cardiovascular events (hazard ratio 1.45, 95% CI 0.81 to 2.61). In conclusion, proteinuria was strongly and independently associated with mortality in patients undergoing PCI. These data suggest that such a relatively simple and clinically easy to use tool as urinary dipstick may be useful to identify and treat patients at high risk of mortality at the time of PCI. (C) 2008 Elsevier Inc. All rights reserved. (Am J Cardiol 2008;102:1151-1155)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background-Randomized trials that studied clinical outcomes after percutaneous coronary intervention (PCI) with bare metal stenting versus coronary artery bypass grafting (CABG) are underpowered to properly assess safety end points like death, stroke, and myocardial infarction. Pooling data from randomized controlled trials increases the statistical power and allows better assessment of the treatment effect in high-risk subgroups. Methods and Results-We performed a pooled analysis of 3051 patients in 4 randomized trials evaluating the relative safety and efficacy of PCI with stenting and CABG at 5 years for the treatment of multivessel coronary artery disease. The primary end point was the composite end point of death, stroke, or myocardial infarction. The secondary end point was the occurrence of major adverse cardiac and cerebrovascular accidents, death, stroke, myocardial infarction, and repeat revascularization. We tested for heterogeneities in treatment effect in patient subgroups. At 5 years, the cumulative incidence of death, myocardial infarction, and stroke was similar in patients randomized to PCI with stenting versus CABG (16.7% versus 16.9%, respectively; hazard ratio, 1.04, 95% confidence interval, 0.86 to 1.27; P = 0.69). Repeat revascularization, however, occurred significantly more frequently after PCI than CABG (29.0% versus 7.9%, respectively; hazard ratio, 0.23; 95% confidence interval, 0.18 to 0.29; P<0.001). Major adverse cardiac and cerebrovascular events were significantly higher in the PCI than the CABG group (39.2% versus 23.0%, respectively; hazard ratio, 0.53; 95% confidence interval, 0.45 to 0.61; P<0.001). No heterogeneity of treatment effect was found in the subgroups, including diabetic patients and those presenting with 3-vessel disease. Conclusions-In this pooled analysis of 4 randomized trials, PCI with stenting was associated with a long-term safety profile similar to that of CABG. However, as a result of persistently lower repeat revascularization rates in the CABG patients, overall major adverse cardiac and cerebrovascular event rates were significantly lower in the CABG group at 5 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Purpose: Central venous catheterization is among the most common procedures performed by pediatric surgeons. Significant morbidity and even mortality can ensue from the widespread approach to the deep veins of the neck and femoral region. The external jugular vein (EJV) is a low-morbidity alternative for percutaneous catheterization in children, but it has yielded a low success rate in previous reports The authors show an improved success rate with this option. Methods: We performed an analysis of 33 patients` charts in which central venous catheterization using Seldinger technique through the EJV was attempted in 2005. Age, diagnosis, maneuvers used for success, fluoroscopy usefulness, and types of inserted catheters were evaluated. Results: The procedure was successful in 26 (78.8%) patients without complications. Diagnosis was neoplasia in almost half of the patients (42%). In half of the successful cases, body maneuvers were used, namely, twisting the head of the patient to the side of the vein and stretching the ipsilateral arm and shoulder. All but one procedure were completed under fluoroscopic guidance. In 6 (23%) patients, a long-term catheter was inserted. Conclusions: The EJV is an excellent option for central venous catheterization in children. The execution of simple maneuvers along with fluoroscopic assistance might allow for an improved success rate not only for short-term but also for long-term catheter insertion. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report a series of patients with symptomatic internal carotid artery (ICA) occlusion treated with angioplasty and stents. MATERIALS AND METHODS: From a consecutive series of 50 patients experiencing neurologic ischemic symptoms and shown by conventional ultrasonography (US) to have a total ICA occlusion, 16 patients (ages 45-79 years; mean, 63 y; 10 men) were selected between August 2006 to September 2008 to be treated with angioplasty based on discovery of an open ICA distal to the occlusion through contrast-enhanced echo Doppler imaging and/or multislice contrast computed tomography (CT). Angioplasty and stent placement were performed under cerebral protection. Follow-up duplex imaging was performed at 14 days and 3 months and every 6 months thereafter and CT follow-up was performed at 2-9 months; the mean follow-up period was 9.9 months. RESULTS: Lesion crossing and stent placement was successful in 13 of 16 patients. There were no deaths, conversions, cardiac complications, or major strokes. One patient had a transient mild hemiparesis in the upper limb, with total recovery in 3 months. At follow-up, all 13 patients with a good initial result remained with patent arterial lumens and resolution of neurologic ischemic symptoms. After 2-9 months, ICAs with a ""string sign"" had calibers close or equal to those of normal arteries. CONCLUSIONS: Angioplasty with stent placement is an effective treatment with a low morbidity rate for selected patients who continue to experience neurologic ischemic symptoms despite US findings of total occlusion of the ICA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Since the cell therapy benefits for myocardial infarction are mainly related to infarct reduction by regenerating lost myocardium or increasing survival of tissues at risk, we evaluated the effects of bone marrow-derived mononuclear cells (MNC), implanted after the completion of necrosis, on infarct progression and cardiac remodeling. Methods: After 48 h of induction of myocardial infarction (MI), Lewis-inbred rats were injected with 6 x 10(6) cells (MI + MNC) or saline (MI). After six weeks, scar dimension, ventricular morphology and function were analyzed by echocardiography followed by histomorphology of the infarcted and border zones. Results: After therapy, the relative size of the infarct was smaller in MI + MNC (37 +/- 1% of the left ventricle) than in MI (43 +/- 1%). While the MI group exhibited parallel elongation of the infarcted (31.6 +/- 3.8% increase) and reminiscent ventricular portions (33.5 +/- 3.7%), MNC therapy preserved the initial infarct length. Infarcted walls were thicker (979 +/- 31 mm) in the MNC group than in the untreated group (709 +/- 41 mm), also demonstrating an absence of infarct expansion. In the border zones, MNC led to increased capillary densities and capillary/myocyte ratios. The cardiac systolic function remained depressed in MI, but improved by 19 +/- 5% in MI + MNC which reduced the incidence of pulmonary arterial hypertension (37.5% in MI and 6.25% in MI + MNC). Conclusion: MNC therapy prevented the infarct expansion and thinning related to cardiac remodeling and was associated with an improvement of border zone microcirculation: as a result, MNC therapy reduced typical MI dysfunctional repercussions. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study provides an investigation of the availability of octyl salicylate (OS), a common sunscreen agent, from liquid paraffin and the effect of OS on skin permeability. A model membrane system to isolate the vehicle effect from membrane permeability has been developed. Partitioning of OS between liquid paraffin and aqueous receptor phases was conducted. Partition coefficients increased with increase in OS concentration. A range of OS concentrations in liquid paraffin was diffused across human epidermis and synthetic membranes into 4% bovine serum albumin in phosphate-buffered saline and 50% ethanol. Absorption profiles of OS obtained from silicone and low-density polyethylene (LDPE) membranes were similar to each other but higher than for the high-density polyethylene [HDPE (3 times)] membrane and human epidermis (15 times). The steady state fluxes and apparent permeability coefficients (K-p') obtained from the diffusion studies showed the same trends with all membranes, except for the HDPE membrane which showed greater increase in flux and K-p' at concentrations above 30%. IR spectra showed that several bands of OS were shifted with concentrations, and the molecular models further suggested that the main contribution to the self-association is from non-1,4 van der Waals interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryoablative therapies have been proposed to palliate pain from soft-tissue or osteolytic bone tumors. A case of a patient with painful thoracic and sacral spine sclerotic metastases successfully treated by image-guided percutaneous cryoablation with the aid of insulation techniques and thermosensors is reported in this case report.