927 resultados para passive sampling


Relevância:

60.00% 60.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: Hospitality workers are a population particularly at risk from the noxious effects of environmental tobacco smoke (ETS). The Canton of Vaud, Switzerland banned smoking in public places in September 2009. This prospective study addresses the impact of the ban on the health of hospitality workers. METHODS: ETS exposure was evaluated using a passive sampling device that measures airborne nicotine; lung function was assessed by spirometry; health-related quality of life, ETS exposure symptoms and satisfaction were measured by questionnaire. RESULTS: 105 participants (smokers and non-smokers) were recruited initially and 66 were followed up after one year. ETS exposure was significantly lower after the ban. Hospitality workers had lower pre-ban forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) values than expected. FEV1 remained stable after the ban, with a near-significant increase in the subgroup of asthmatics only. FVC increased at one year follow-up from 90.42% to 93.05% (p = 0.02) in the entire cohort; women, non-smokers and older participants gained the greatest benefit. The health survey showed an increase in physical wellbeing after the ban, the greatest benefit being observed in non-smokers. ETS exposure symptoms were less frequent after the ban, especially red and irritated eyes and sneezing. The new law was judged useful and satisfactory by the vast majority of employees, including smokers. CONCLUSION: The recent cantonal ban on smoking in public places brought about an improvement in lung function, physical well-being and ETS symptoms of hospitality workers, including smokers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Second Hand Tobacco Smoke (SHTS) or Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of collected nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GC-TSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as the reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for non-smokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers, we can confirm the use of the CE concept for estimating exposure to ETS. The regional CIPRET (Center of information and prevention of the addiction to smoking) of different cantons (Valais (VS), Vaud (VD), Neuchâtel (NE) and Fribourg (FR)) are going to organize a big campaign on the subject of the passive addiction to smoking. This campaign took place in 2007-2008 and has for objective to inform clearly the Swiss population of the dangerousness of the passive smoke. More than 3'900 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva was also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study. This study, unique in Switzerland, has established a base map on the population's exposure to SHTS. It underscored the fact that all the Swiss people involved in this campaign (N=1241) is exposed to passive smoke, from <0.2 cig/d (10.8%), 1-2 to more than 10 cig/d (89.2%). In the area of high exposure (15-38 cig/d), are the most workers in public restaurant, cafe, bar, disco. By monitoring ETS tracer nicotine and its biomarkers, salivary nicotine and cotinine, it is demonstrated that the MoNIC badge can serve as indicator of CE passive smoking. The MoNIC badge, accompanied with content of salivary nicotine/cotinine can serve as a tool of evaluation of the ETS passive smoking and contributes to supply useful data for future epidemiological studies. It is also demonstrated that the salivary nicotine (without stimulation) is a better biomarker of ETS exposure than cotinine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The passive sampling technique has been widely used for many years in the measurement of personal exposure to pollutantes in the workplace. In recent years the technique has been used too for measurements in ambient air. In the specific case of SO2 a variety of passive samplers have been described in the literature. The great number are diffusive samplers and some few are permeation samplers. They are basically of two types: badge and tube-type. However there are more than 10 variations in relation to the sampler dimensions, diffusion barriers and pollutant sorption medium. The technique trend to be very used in the near future with samplers able to reach very low detection limits, proposing a viable option for monitoring specific species at urban, regional and global scales.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new passive sampling system for monitoring NO2 in air has been developed to measure gas concentrations in indoor and outdoor air. The sampler is inexpensive, and easy to construct and operate. Nitrogen dioxide forms a derivative after reaction with a filter coated with triethanolamine and ethyleneglycol. The nitrogen dioxide derivative is extracted from the filter, and the concentration is determined by colorimetry. To test the sampler for measuring ambient level nitrogen dioxide, measurements were carried out inside homes and in a range of workplace environments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study is a result of undergraduate student participation in the Environmental Chemistry discipline provided by the Chemistry Institute/UFBA. The students were involved in the development of passive samplers, a project of the LAQUAM (Environmental Analytical Chemistry Laboratory). The students' residences and other neighborhoods were used to create a passive sampling network, allowing the measurement of atmospheric levels of pollutants in urban areas and in those under industrial influence. The assembly of the passive samplers, including impregnation of filters and chemical analysis were part of the students' practice tasks. The results were analyzed taking into consideration the Brazilian legislation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to assess a new monitoring technique of particulate and trace metals in the atmosphere via the use of a passive sampler of air pollutants in the city of Goiânia. The average particulate weight and average concentrations of metals Fe, Cr, Zn, Pb, Cu, Mn, and Cd were 0.1104 g and 257.5; 23.4; 17.8; 6.7; 1.9; 0.8; 0.2 μg/m²/day, respectively. Higher Pb and Cr concentrations were obtained in areas with intense traffic. This study revealed that it is possible to monitor trace metals with passive sampling, developed at a low cost and operational facility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes a methodology to predict benzene uptake rate in ambient air, using passive samplers with Tenax TA. Variations in the uptake rate were found to occur as a function of the sampling time; and were greater at the beginning of sampling. An empirical model was obtained and values for uptake rate agree with literature. Concentration prediction errors can be minimized by using sampling times of 4 to 14 days, thus avoiding the influence of excessive uptake rates in the initial days and the influence of back diffusion at the end of the sampling period.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The type and thickness of insulation on the topside horizontal of cold pitched roofs has a significant role in controlling air movement, energy conservation and moisture transfer reduction through the ceiling to the loft (roof void) space. To investigate its importance, a numerical model using a HAM software package on a Matlab platform with a Simulink simulation tool has been developed using insitu measurements of airflows from the dwelling space through the ceiling to the loft of three houses of different configurations and loft space. Considering typical UK roof underlay (i.e. bituminous felt and a vapour permeable underlay), insitu measurements of the 3 houses were tested using a calibrated passive sampling technique. Using the measured airflows, the effect of air movement on three types of roof insulation (i.e. fibreglass, cellulose and foam) was modelled to investigate associated energy losses and moisture transport. The thickness of the insulation materials were varied but the ceiling airtightness and eaves gap size were kept constant. These instances were considered in order to visualize the effects of the changing parameters. In addition, two different roof underlays of varying resistances were considered and compared to access the influence of the underlay, if any, on energy conservation. The comparison of these insulation materials in relation to the other parameters showed that the type of insulation material and thickness, contributes significantly to energy conservation and moisture transfer reduction through the roof and hence of the building as a whole.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Worldwide environmental degradation is an undesirable byproduct resulting from the increasing demand for natural resources. Water sources are suffering intense contamination since they usually receive a huge amount of domestic and industrial effluents - which are mostly wasted without proper treatment - inserting a large number of pollutants in the environment, heavy metals included. Mercury holds great toxicological importance because, under some physicochemical conditions in a water environment, Hg (II) ion turns into methylated compounds stemming from this element, such as methylmercury CH3Hg, which is highly toxic for the aquatic community in which bioaccumulation occurs. Nowadays passive sampling techniques are being developed to enable the analytical procedures which are applied in environmental monitoring. Diffusive gradients in thin-films technique (DGT) has been proven an interesting tool for the determination of labile metal species due to its in situ application. The DGT technique consists of a piston-like device on which the following series of agents is disposed: a binding agent (conventionally Chelex 100 resin), a diffusive agent, usually a polyacrylamide gel, and a membrane filter. Nevertheless, the agents conventinally used for this technique don't usually show satisfactory results in mercury sampling. The main goal of this study was to evaluate the phosphate-treated cellulose membrane (Whatman P 81), an alternative material, as binding agent in the DGT to determine labile mercury fractions in aquatic systems. In this context, we conducted a study of the behavior of this material in relation with system variables, pH and ionic strength. Afterwards we performed immersions of the DGT devices in real and enriched samples and in situ aiming the determination of mercury

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the work underlying this thesis solid-phase microextraction (SPME) was evaluated as a passive sampling technique for organophosphate triesters in indoor air. These compounds are used on a large scale as flame-retarding and plastizicing additives in a variety of materials and products, and have proven to be common pollutants in indoor air. The main objective of this work was to develop an accurate method for measuring the volatile fraction. Such a method can be used in combination with active sampling to obtain information regarding the vapour/particulate distribution in different indoor environments. SPME was investigated under both equilibrium and non-equilibrium conditions and parameters associated with these different conditions were estimated. In Paper I, time-weighted average (TWA) SPME under dynamic conditions was investigated in order to obtain a fast air sampling method for organophosphate triesters. Among the investigated SPME coatings, the absorptive PDMS polymer had the highest affinity for the organophosphate triesters and was consequently used in all further work. Since the sampling rate is dependent on the agitation conditions, the linear airflow rates had to be carefully considered. Sampling periods as short as 1 hour were shown to be sufficient for measurements in the ng-μg m-3 range when using a PDMS 100-μm fibre and a linear flow rate above 7 cm s-1 over the fibre. SPME under equilibrium conditions is rather time-consuming, even under dynamic conditions, for slowly partitioning compounds such as organophosphate triesters. Nevertheless, this method has some significant advantages. For instance, the limit of detection is much lower compared to 1 h TWA sampling. Furthermore, the sampling time can be ignored as long as equilibrium has been attained. In Paper II, SPME under equilibrium conditions was investigated and evaluated for organophosphate triester vapours. Since temperature and humidity are closely associated with the distribution constant a simple study of the effect of these parameters was performed. The obtained distribution constants were used to determine the air levels in a common indoor environment. SPME and parallel active sampling on filters yielded similar results, indicating that the detected compounds were almost entirely associated with the vapour phase To apply dynamic SPME method in the field a sampler device, which enables controlled linear airflow rates to be applied, was constructed and evaluated (Paper III). This device was developed for application of SPME and active sampling in parallel. A GC/PICI-MS/MS method was developed and used in combination with active sampling of organophosphate triesters in indoor air (Paper IV). The combination of MS/MS and the soft ionization achieved with methanol as reagent gas yielded high selectivity and detection limits comparable to those provided by GC with nitrogen-phosphorus detection (NPD). The method limit of detection, when sampling 1.5 m3 of air, was in the range 0.1-1.4 ng m-3. In Paper V, the developed MS method was used in combination with SPME for indoor air measurements. The levels detected in the investigated indoor environments range from a few ng to μg m-3. Tris(2-chloropropyl) phosphate was detected at a concentration as high as 7 μg m-3 in a newly rebuilt lecture room.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Groundwater represents one of the most important resources of the world and it is essential to prevent its pollution and to consider remediation intervention in case of contamination. According to the scientific community the characterization and the management of the contaminated sites have to be performed in terms of contaminant fluxes and considering their spatial and temporal evolution. One of the most suitable approach to determine the spatial distribution of pollutant and to quantify contaminant fluxes in groundwater is using control panels. The determination of contaminant mass flux, requires measurement of contaminant concentration in the moving phase (water) and velocity/flux of the groundwater. In this Master Thesis a new solute flux mass measurement approach, based on an integrated control panel type methodology combined with the Finite Volume Point Dilution Method (FVPDM), for the monitoring of transient groundwater fluxes, is proposed. Moreover a new adsorption passive sampler, which allow to capture the variation of solute concentration with time, is designed. The present work contributes to the development of this approach on three key points. First, the ability of the FVPDM to monitor transient groundwater fluxes was verified during a step drawdown test at the experimental site of Hermalle Sous Argentau (Belgium). The results showed that this method can be used, with optimal results, to follow transient groundwater fluxes. Moreover, it resulted that performing FVPDM, in several piezometers, during a pumping test allows to determine the different flow rates and flow regimes that can occurs in the various parts of an aquifer. The second field test aiming to determine the representativity of a control panel for measuring mass flus in groundwater underlined that wrong evaluations of Darcy fluxes and discharge surfaces can determine an incorrect estimation of mass fluxes and that this technique has to be used with precaution. Thus, a detailed geological and hydrogeological characterization must be conducted, before applying this technique. Finally, the third outcome of this work concerned laboratory experiments. The test conducted on several type of adsorption material (Oasis HLB cartridge, TDS-ORGANOSORB 10 and TDS-ORGANOSORB 10-AA), in order to determine the optimum medium to dimension the passive sampler, highlighted the necessity to find a material with a reversible adsorption tendency to completely satisfy the request of the new passive sampling technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nitrogen dioxide (NO$\sb2)$ levels in sixteen substandard houses located in Houston, Texas were examined. The classification of the houses as substandard was based on an assessment of structural integrity which would affect air exchange rates. In these homes, unvented gas space heaters were operated as the primary source of heat.^ The Ogawa passive sampling device was used to measure NO$\sb2$ concentrations over 24 to 48-hour periods during generally cold weather. A sampler was placed in the kitchen and bedroom of each house. The female head of household was asked to wear a monitor during area monitoring to assess her personal exposure. Outdoor levels of NO$\sb2$ were also measured.^ Mean (standard deviation) levels of kitchen, bedroom and personal exposures were 280 (125) ppb, 256 (155) ppb and 164 (102) ppb, respectively. Additional short-term ($<$24 hours) samples were measured in three houses. The mean level of NO$\sb2$ measured outdoors was 51 ppb over the course of the study.^ The measurements obtained with the Ogawa sampler were compared to those levels obtained using a reference method (chemiluminescence). Outdoor levels measured with the diffusion samplers were 48% higher.^ These results suggest that wintertime NO$\sb2$ levels within substandard houses using gas appliances for heating and cooking are extremely elevated. Further work is needed to investigate the prevalence of possible health effects associated with these exposures. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two water quality monitoring strategies designed to sample hydrophobic organic contaminants have been applied and evaluated across an expected concentration gradient in PAHs in the Moreton region. Semipermeable membrane devices (SPMDs) that sequester contaminants via passive diffusion across a membrane were used to evaluate the concentration of PAHs at four and five sites in spring and summer 2001/2002, respectively. In addition, induction of hepatic cytochrome P4501, EROD activity, in yellowfin bream, Acanthopagrus australis, captured in the vicinity of SPMD sampling sites following deployment in summer was used as a biomarker of exposure to PAHs and related chemicals. SPMDs identified a clear and reproducible gradient in PAH contamination with levels increasing from east to west in Moreton Bay and upstream in the Brisbane River. The highest PAH concentrations expressed as B(a)P-toxicity equivalents (TEQs) were found in urban areas, which were also furthest upstream and experienced the least flushing. Cytochrome P4501 induction in A. australis was similar at all sites. The absence of clear trends in EROD activity may be attributable to factors not measured in this study or variable residency time of A. australis in contaminated areas. It is also possible that fish in the Moreton region are displaying enzymatic adaptation, which has been reported previously for fish subjected to chronic exposure to organic contaminants. These potential interferences complicate interpretation of EROD activity from feral biota. It is, therefore, suggested that future monitoring combine the two methods by applying passive sampler extracts to in vitro EROD assays. (C) 2004 Elsevier Ltd. All rights reserved.