995 resultados para operative technique
Resumo:
BACKGROUND A caesarean scar defect is a late complication of caesarean birth with a wide range of prevalence between 56 and 84 % depending on which diagnostic tool and which definition is used [1]. The referred symptoms which include postmenstrual spotting and infertility are fortunately rare. Moreover, severe complications such as caesarean scar pregnancy and uterine rupture in the following pregnancy may occur. Given the increasing incidence of caesarean births, the potential morbidity associated with caesarean scars is likely to become more important. Recently, a few repair techniques were described in the literature including the hysteroscopic resection of scarred tissue or the laparoscopic repair with or without robotic assistance [2, 3]. METHODS Between June 2009 and February 2014, 21 women with caesarean scar defects were operated with the Rendez-vous technique, a minimally invasive surgery combining the laparoscopic and hysteroscopic approach. Data were retrospectively collected. The indications for this surgery included secondary infertility, previous caesarean scar pregnancy, recurrent miscarriage and postmenstrual spotting. Prior to operation, a transvaginal ultrasound was performed to examine the uterine wall defect. RESULTS The patient characteristics are provided in Table 1. In all cases, the operation was successfully completed laparoscopically. The median operation time was 125 min. One case was complicated by recurrence of the scar defect 6 weeks after the operation. No other intra- or post-operative complications were observed, and the median in-patient stay was 3 days. CONCLUSIONS The benefits of the technique include the feasibility and safety of the procedure, the "Halloween sign" (Fig. 1) which indicates the exact extent and localization of the scar defect and the immediate assessment of repair through the hysteroscopy at the end of the surgery. However, before further studies evaluate the efficacy of this method, the routine repair of caesarean scar defects cannot be recommended. A video of the technique is presented.
Resumo:
In the last decades accumulated clinical evidence has proven that intra-operative radiation therapy (IORT) is a very valuable technique. In spite of that, planning technology has not evolved since its conception, being outdated in comparison to current state of the art in other radiotherapy techniques and therefore slowing down the adoption of IORT. RADIANCE is an IORT planning system, CE and FDA certified, developed by a consortium of companies, hospitals and universities to overcome such technological backwardness. RADIANCE provides all basic radiotherapy planning tools which are specifically adapted to IORT. These include, but are not limited to image visualization, contouring, dose calculation algorithms-Pencil Beam (PB) and Monte Carlo (MC), DVH calculation and reporting. Other new tools, such as surgical simulation tools have been developed to deal with specific conditions of the technique. Planning with preoperative images (preplanning) has been evaluated and the validity of the system being proven in terms of documentation, treatment preparation, learning as well as improvement of surgeons/radiation oncologists (ROs) communication process. Preliminary studies on Navigation systems envisage benefits on how the specialist to accurately/safely apply the pre-plan into the treatment, updating the plan as needed. Improvements on the usability of this kind of systems and workflow are needed to make them more practical. Preliminary studies on Intraoperative imaging could provide an improved anatomy for the dose computation, comparing it with the previous pre-plan, although not all devices in the market provide good characteristics to do so. DICOM.RT standard, for radiotherapy information exchange, has been updated to cover IORT particularities and enabling the possibility of dose summation with external radiotherapy. The effect of this planning technology on the global risk of the IORT technique has been assessed and documented as part of a failure mode and effect analysis (FMEA). Having these technological innovations and their clinical evaluation (including risk analysis) we consider that RADIANCE is a very valuable tool to the specialist covering the demands from professional societies (AAPM, ICRU, EURATOM) for current radiotherapy procedures.
Resumo:
Background and Objectives: Peripheral nerve blockade requires regional anesthesia skills that trainees learn in several formats. Technical proficiency has shifted from a quota to comprehensive procedural evaluation. Successful nerve blockade is the clinical endpoint validating proficiency but patient, technical and procedural factors influence this result. The purpose of this study was to determine if procedural expertise for sciatic nerve blockade influenced postoperative pain scores and opioid requirements and if patient factors, technique and repetition influenced this outcome. Method: Sciatic nerve blockade by nerve stimulation and ultrasound guidance and training level of the resident performing the procedure were recorded. Patient obesity, trauma, chronic pain, opioid use and preoperative pain scores were compared to post-procedure pain scores and opioid analgesic requirements. Results: 102 patients received sciatic nerve blockade from 47 trainees over a 36 month interval. A significant relation between training level and improved pain scores was not demonstrated but transition from nerve stimulation to ultrasound guidance lowered scores in all groups. Nerve blockade failure was frequent with chronic opioid use and trauma. Conclusion: Analgesic outcomes should be an integral part of assessment of proficiency in regional anesthesia techniques. Evaluating outcomes of procedures throughout training will longitudinally assess technical expertise.
Resumo:
Sciatic nerve blockade (SNB) can be performed at several point along its anatomic course. Proximal SNB techniques described include the classic Labat, sacral (Mansur), infragluteal (Raj), and anterior approches Distal SNB techniques include the mid-femoral, posterior and lateral popliteal and mid-tibial approaches. The anatomic region of the lower extramity to be anesthetixzed will determine the appropriate SNB technique to use for the operative procedure.
Resumo:
A class of intelligent systems located on anthropocentric objects that provide a crew with recommendations on the anthropocentric object's rational behavior in typical situations of operation is considered. We refer to this class of intelligent systems as onboard real-time advisory expert systems. Here, we present a formal model of the object domain, procedures for obtaining knowledge about the object domain, and a semantic structure of basic functional units of the onboard real-time advisory expert systems of typical situations. The stages of the development and improvement of knowledge bases for onboard real-time advisory expert systems of typical situations that are important in practice are considered.
Resumo:
Hallux rígidus (HR) affects the first metatarsophalangeal joint (MTPJ) between 35% and 60% of the population over 65 years and there are multiple ways of treatment. Depending on the radiological stage where you find the deformity determines the procedure to be performed; in the early stages cheilectomy techniques and corrective osteotomy is performed while the more advanced ratings, the surgeon chooses destructive techniques considered as arthrodesis and arthroplasty. This final of degree project aims to focus on 1 MTPJ destructive techniques to clarify which of the procedures generates better results by a number of parameters; outcomes of the American Orthopaedic Foot scale and Ankle Society Hallux metatarsophalangeal Interphalangeal-scale (AOFAS), range of motion (ROM) of the 1ºAMTF, radiological classification. As for the implant arthroplasty technique, this article offers information on material and design that generates better relating to patient characteristics such as age, inflammatory joint diseases, viability and durability of the implant results. The conclusion from this review is that the values obtained in the arthrodesis according AOFAS decrease due to loss of mobility, but both techniques have similar values of effectiveness and concludes with the decision that the technique used is determined taking into account various factors and patient characteristics. Keywords: Hallux rígidus; (Hallux Rígidus) and surgery treatment; Hallux Rígidus arthrodesis; Hallux Rígidus arthroplasty; Hallux Rígidus (arthroplasty and arthrodesis).
Resumo:
Pelvic organ prolapse suspension (POPS) is a recent surgical procedure for one-stage treatment of multiorgan female pelvic prolapse. This study evaluates the preliminary results of laparoscopic POPS in 54 women with a mean age of 55.2 and a BMI of 28.3. Patients underwent at the same time stapled transanal rectal resection (STARR) to correct the residual rectal prolapse. We had no relapses and the preliminary results were excellent. We evaluated the patients after 1 year follow-up and we confirmed the validity of our treatment. The technique is simplier than traditional treatments with an important reduction or completely disappearance of the pre-operative symptomatology.